6MV 선형가속기를 사용한 유방암 치료 (A Trial of 6-MV Linear Accelerator Radiation Therapy (RT) for Breast Cancer)

  • 윤세철;권형철;오윤경;김종우;박용휘
    • Radiation Oncology Journal
    • /
    • 제2권2호
    • /
    • pp.303-309
    • /
    • 1984
  • Radiation therapy(RT) has been used in the treatment of breast cancer for over 80years. Technically, it should include a part or all of such areas as chest wall or breast, axilla, internal mammary nodes (IM) and supraclavicular nodes (SCL). Authors tried three-field technique for the treatment of breast cancer using 6-MV linear accelerator, exclusively the department of radiology. Kang-Nam St. Mary's Hospital, at Catholic Medical College. The field junction was checked by a Phantom study and radiation doses measured by film densitometry and TLD. The 3 fields we used in this study were two isocentric opposing tangential fields encompassing the breast, chest wall and occasionally IM and one single anterior field encompassing the axilla and SCL. sing appropriate beam blocks and boluses, we were able to avoid unwanted intrinsic divergency of photon beam. Blocking also enabled us to set-up precise radiation field with ease.

  • PDF

한국의학물리학회 선형가속기 외부 품질관리 실시 현황보고 (Report on the External Audits Conducted by Korean Society of Medical Physics)

  • 허현도;조광환;조삼주;최상현;김동욱;황의중;김기환;민철기;최태진;오영기;이승준;박달;박성광;지영훈
    • 한국의학물리학회지:의학물리
    • /
    • 제24권4호
    • /
    • pp.315-322
    • /
    • 2013
  • 전문가 그룹의 외부검사를 통하여 의료기관 자체적으로 시행되고 있는 품질관리를 평가하고 구조적 문제점에 대한 상호보완을 하고자 하였다. 외부 검사의 정당성 확보를 위해 전국 80여 개의 의료기관 중 지역 분포를 고려하여 30여 개를 선정하였고, 최종 25개의 의료기관이 자발적 참여의사를 신청하였다. 참여의료기관은 비공개를 원칙으로 하였고, 사전에 상호 비교하여 검증된 측정 장비를 가지고 직접 방문하여 측정하는 것을 원칙으로 하였다. 두 개 이상의 광자선을 대상으로 출력선량을 측정하였고, 갠트리회전 정확도, 콜리메이터 회전 정확도, 다엽콜리메이터 이동 위치 정확도 등을 측정하였다. 출력선량 측정에서 6 MV의 경우 -0.8%~4.5%까지 절대오차를 보였고, 10 MV의 경우 -0.79%~3.01%이었고, 15 MV에서 -0.7%~0.07% 절대오차를 나타내었다. 25개 의료 기관을 대상으로 한 50개의 광자선 중에서 절대 흡수선량이 2% 이상 되는 에너지가 8개(16%)로 나타났다. 조사면과 갠트리, 콜리메이터 회전축 일치도는 2개 의료기관을 제외하고 모두 ${\pm}2$ mm 이내의 결과를 보였다. 다엽콜리메이터 이동 위치 정확도는 모두 ${\pm}1$ mm 이내의 정확도를 보였다. 에너지 선질 조사에서 광자선 6 MV의 경우 KQ 값의 최고값과 최저값의 차이는 0.4%로 나타났다. 물 흡수선량 기반 측정 기준서 사용기관은 21개(84%), 공기 흡수선량 기반 측정 기준서 사용기관은 4개(16%)로 조사되었고, SSD 측정법을 사용하는 기관은 22개, SAD 측정법을 사용하는 기관은 3개 기관으로 조사되었다. 외부검사는 자체적으로 시행되고 있는 품질관리의 구조적인 문제점을 찾아 상호 보완하는 것임으로 매우 중요하다. 따라서 전문가 그룹 및 국가가 함께 주기적이고, 지속적인 외부검사가 시행 될 수 있도록 국제 수준의 전문가의 양성 및 국가지원 제도가 필요하다고 사료된다.

전립선 암 입체적세기변조방사선치료 시 체형 및 에너지 변화에 따른 선량 평가 (Dosimetric comparison for Prostate VMAT of weight and photon energy change)

  • 조광섭;김민우;백민규;채종표;하세민;이상봉
    • 대한방사선치료학회지
    • /
    • 제30권1_2호
    • /
    • pp.17-25
    • /
    • 2018
  • 목 적 : 전립선 암 환자의 입체적세기변조방사선치료(VMAT)시 복부체형 및 에너지 변화에 따른 선량을 비교하였다. 대상 및 방법 : 전립선암으로 본원에 내원한 7명의 환자를 대상으로 하였으며, 복부체형을 -2.0 cm에서 2 cm까지 0.5 cm씩 변화시키는 동시에 6, 10, 15 MV 각각의 에너지에서 VMAT 치료계획을 수립하였다. 체형변화에 따른 표적장기 내 선량변화를 평가하기 위해 PTV의 선량도(Conformal index, CI), 선량균등도(Homogeneous index, HI), $D_{max}$ $D_{95%}$, $D_{50%}$, $D_{2%}$를 조사하였고, 정상조직 내 선량 변화를 평가하기 위해 직장과 방광의 $V_{70Gy}$, 대퇴부 머리의 $D_{max}$를 분석하였다. 결 과 : PTV 내의 $D_{max}$ 값 중 6 MV에서는 1.0 cm의 체형 감소에서 107.2 %로 선량이 상승하였고, 10 MV와 15 MV에서는 1.5 cm 체형 감소에서 각각 107.1 %, 107.0 %로 선량이 증가하였다. PTV 내의 $D_{50%}$ 값 중 6MV에서는 1.0 cm의 체형 증가에서 99.64 %로 선량이 감소하였고, 10 MV와 15 MV에서는 1.5 cm 체형 증가에서 각각 99.78 %, 99.97 %로 선량이 감소하였다. 2.0 cm 체형 증가에서는 각각 99.30 %, 99.52 %로 선량 감소를 보였다. 직장과 방광에 대한 선량은 체형이 감소됨에 따라 점차적으로 선량이 증가하였고, 체형이 증가됨에 따라 선량이 감소하였다. 6 MV에서 가장 급격한 선량 감소를 보였으며, 10 MV에서 직장 $V_{70Gy}$는 체형이 2.0 cm 줄어들 때 11.50 %에서 12.76 %로 증가했다. 방광 $V_{70Gy}$도 14.0 %에서 15.2 %로 증가했다. 또한 대퇴부 머리에서도 체형이 감소됨에 따라 선량이 증가함을 나타내었다. 결 론 : VMAT 치료시 복부체형 변화에 따라 선량분포 결과가 바뀔 수 있는데, 치료 시 SSD 및 CBCT를 이용하여 6 MV에서는 체형이 1 cm 이상 감소되거나 1.0 cm 이상 증가되었을 때, 10 MV와 15 MV에서는 1.5 cm 감소 또는 1.5 cm 증가되었을 시 re-simulation을 통해 치료계획을 새로 세워야 할 것으로 사료되어진다.

  • PDF

두경부암 세기변조방사선치료 계획 시 부분적 고에너지 광자선 사용에 따른 치료계획 평가 (The Effect of Partially Used High Energy Photon on Intensity-modulated Radiation Therapy Plan for Head and Neck Cancer)

  • 장남준;석진용;원희수;홍주완;최지훈;박진홍
    • 대한방사선치료학회지
    • /
    • 제25권1호
    • /
    • pp.1-8
    • /
    • 2013
  • 목 적: 체내에서 광자선은 에너지에 따라 다른 선량분포 특성을 보이기 때문에 치료계획 시 적절한 에너지 선택이 중요하다. 두경부암 세기변조방사선치료(intensity modulated radiation therapy, IMRT)는 주로 저에너지 광자선을 사용하는데, 본 연구에서는 후사방향 조사면에 부분적으로 고에너지 광자선을 사용하였을 때 치료계획에 미치는 영향을 알아보고자 한다. 대상 및 방법: 본원에서 두경부암 세기변조방사선치료를 시행한 10명(nasopharyngeal carcinoma 5, tonsilar carcinoma 5)의 환자를 대상으로 하였다. 동일한 조건하에 환자의 CT영상을 3 mm 두께로 획득하고 치료계획시스템은 Eclipse (Ver 7.1, Varian, Palo Alto, USA)를 사용하였다. 환자마다 8개 조사면으로 6 MV 에너지를 사용한 치료계획(low energy plan, LEP)과 상대적으로 투과 깊이가 깊은 후사방향의 2개 조사면에서 15 MV 에너지를 사용한 치료계획(partially used high energy plan, PHEP)을 각각 수립하였으며, 다른 치료계획조건들과 plan normalization은 동일하게 적용하였다. 수립된 치료계획을 평가하기 위해서 계획표적체적(planning target volume, PTV)의 coverage, conformity index (CI), homogeneity index (HI)를 비교하였고 양측 이하선의 $D_{mean}$, $D_{50%}$와 뇌척수의 $D_{max}$, $D_{1%}$ 그리고 integral dose (ID)를 비교하였다. 특히, 후경부의 정상조직선량을 비교하기 위해 posterior-normal tissue volume (P-NTV)을 설정하고 dose volume histogram (DVH)을 통해서 $D_{mean}$, $V_{20Gy}$, $V_{25Gy}$를 평가하였으며, 또한 총 monitor unit (MU)의 변화를 비교하였다. 결 과: LEP와 PHEP 사이에서 PTV의 coverage 그리고 CI의 차이는 크지 않았고, HI는 변화없이 전체적으로 동일하게 나타났다. 뇌척수의 선량변화는 크지 않았지만 양측 이하선의 $D_{mean}$, $D_{50%}$ 그리고 ID는 PHEP에서 각각 0.6%, 0.7%, 1.1% 감소하였다. P-NTV의 $D_{mean}$, $V_{20Gy}$, $V_{25Gy}$는 PHEP에서 각각 1.6%, 1.8%, 2.9% 감소하였고, 총 MU도 평균 1.8% 감소하였다. 결 론: 본 연구결과 후사방향에서 부분적으로 고에너지를 사용한 치료계획에서 일부 결정장기(organ at risk, OAR)와 정상조직의 선량, 그리고 총 MU를 감소시키는 효과가 있었다. 이런 효과가 환자에게 임상적으로 얼마나 이로운지는 명확하지 않지만, 두경부암 세기변조방사선치료 계획 시 부분적으로 고에너지 광자선을 사용하는 것은 치료계획의 전반적인 질을 개선하는 데 유용 할 것으로 본다.

  • PDF

측정된 원통형 전리함 반응함수의 몬테카를로 시뮬레이션 보정 (The ionization chamber response function from the measured and the corrected by Monte Carlo simulation.)

  • 이병용;김미화;조병철;나상균;김종훈;최은경;장혜숙
    • 한국의학물리학회지:의학물리
    • /
    • 제7권1호
    • /
    • pp.9-17
    • /
    • 1996
  • 방사선 측정기로 사용되는 원통형 전리함의 위치별 반응 함수를 좁은 방사선장에서 측정하였다. 광자선 에너지 4MV, 6MV, 15MV, 전리함 내경 0.5cm~3.05cm 인 전리함들에 대하여 방사선면의 크기를 0.2$\times$20$\textrm{cm}^2$로 하여 물속 10cm 깊이에서 전리함 반응함수를 측정하였다. 좁은 방사선면의 선량분포 profile 을 EGS4(Electron Gamma Shower 4) 몬테카를로 시뮬레이션 코드를 이용하여 계산하였고, 이 결과를 측정된 전리함의 반응 함수 값에서 되겹말림 (deconvolution) 기법으로 제거하여 순수하게 $\delta$함수 모양의 방사선장으로부터 측정된 반응함수로 보정하였다. 전리함 반응함수는 보정전에는 에너지에 따라 다르게 나타났으나 EGS4 계산으로 얻어진 선량분포 프로파일 (profile)을 보정한 결과 전리함 반응 함수는 에너지와 무관한 것으로 나타났다.

  • PDF

전신방사선조사 시 선속 스포일러에 따른 선량 분포 및 영향 평가 (Beam Spoiler-dependent Total Body Irradiation Dose Assessment)

  • 이동연;김정훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권2호
    • /
    • pp.141-148
    • /
    • 2018
  • This study examined the properties of photons and the dose distribution in a human body via a simulation where the total body irradiation(TBI) is performed on a pediatric anthropomorphic phantom and a child size water phantom. Based on this, we tried to find the optimal photon beam energy and material for beam spoiler. In this study, MCNPX (Ver. 2.5.0), a simulation program based on the Monte Carlo method, was used for the photon beam analysis and TBI simulation. Several different beam spoiler materials (plexiglass, copper, lead, aluminium) were used, and three different electron beam energies were used in the simulated accelerator to produce photon beams (6, 10, and 15 MeV). Moreover, both a water phantom for calculating the depth-dependent dosage and a pediatric anthropomorphic phantom for calculating the organ dosage were used. The homogeneity of photon beam was examined in different depths for the water phantom, which shows the 20%-40% difference for each material. Next, the org an doses on pediatric anthropomorphic phantom were examined, and the results showed that the average dose for each part of the body was skin 17.7 Gy, sexual gland 15.2 Gy, digestion 13.8 Gy, liver 11.8 Gy, kidney 9.2 Gy, lungs 6.2 Gy, and brain 4.6 Gy. Moreover, as for the organ doses according to materials, the highest dose was observed in lead while the lowest was observed in plexiglass. Plexiglass in current use is considered the most suitable material, and a 6 or 10 MV photon energy plan tailored to the patient condition is considered more suitable than a higher energy plan.

1차원 광섬유 팬텀선량계를 이용한 치료용 광자선의 피부 및 선량보강영역에서 상대선량 측정 (Measurement of Relative Depth dose of Therapeutic Photon Beam Using One-Dimensional Fiber-Optic Phantom Dosimeter)

  • 문진수;장경원;유욱재;서정기;박장연;조영호;이봉수
    • 센서학회지
    • /
    • 제20권2호
    • /
    • pp.96-101
    • /
    • 2011
  • In this study, we fabricated a fiber-optic phantom dosimeter by arraying square type of plastic optical fibers in a PMMA phantom for measuring relative depth doses of therapeutic photon beams. To minimize the cross-talk between fiber-optic dosimeters, we selected appropriate septum by measuring leaked scintillating lights according to the various kinds of septa. In addition, we measured percentage depth doses of 6, 15 MV photon beams using a fiber-optic phantom dosimeter.

전이성 골종양의 고식적 방사선 치료 (The Palliative Radiotherapy in Bone Metastases)

  • 최영민;이형식;허원주
    • Radiation Oncology Journal
    • /
    • 제12권2호
    • /
    • pp.201-207
    • /
    • 1994
  • To objectively compare the response of the palliative radiotherapy in bone metastatic patients which decreases pain and prevents pathologic fractures, we introduced and applied the RTOG pain and narcotic measure system. From Oct in 1991 to July in 1993, thirty-two patients with painful bone metastases, 17 of them were solitary lesions and others were multiple lesions, were treated with mainly 6 MV photon otherwise 15 MV photon. Radiation doses to bone metastatic sites ranged about from 2000 to 4600cGy. Responses of radiation therapy were compared with days of pre-RT, RT finish, 3, 6, 9 months after the start of RT and solitary versus multiple lesions and follow up scores according to the RTOG measure system. Survival analysis was done. Pain and narcotic score of the entire patients were 7.3, 7.8 at the pre-RT period and 2.6, 3.9 at the immediate or 2 weeks after RT, which was $64{\%},\;50{\%}$ decrement compared with the pre-RT score, Pain scores of 3, 6 and 9 months after the beginning of irradiation were 3.6, 3.7 and 3.3. The best response found in the breast and prostate primaries was $84\%,\;78\%$ decrement of pain score as compared with pre-RT score(statistically insignificant). Median survival was 5.5 months and mean survival was 5 months. We conclude that the RTOG pain and narcotic measure system is relatively effective scale in the comparison of before and after palliative irradiation to the painful bone metastatic sites but more detailed parameters will be required in the narcotic scoring system. More aggressive but less or similiar toxic radiotherapy is needed in the patients having relatively long life expected time.

  • PDF

방사선치료 시 자세확인시스템이 처방선량에 미치는 영향 (The Effect of Patients Positioning System on the Prescription Dose in Radiation Therapy)

  • 김정호;배석환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권4호
    • /
    • pp.613-620
    • /
    • 2017
  • 방사선치료 시 치료계획 선량의 정확한 전달이 중요하다. 뿐만 아니라 정확한 자세 잡이도 필요하다. 하지만 정확한 자세 잡이를 위해서는 자세촬영을 실시하여야 하며 이에 따른 추가적인 방사선 피폭이 발생하게 된다. 이에 자세촬영 주기에 따른 선량분포의 변화를 분석하고자 한다. 팬텀 내 45개 지점에 대해 OSLD를 이용하여 6MV와 10MV 광자선, 그리고 온보드이미지촬영과 콘빔전산화단층촬영에 대한 선량을 측정하였다. 그리고 각 지점에 대한 자세확인촬영이 치료선량에 합산될 경우의 차이값을 비교하였다. 또한 차이값이 미국의학물리협회에서 권고하는 5%를 만족하는 촬영 주기를 제시하고자 하였다. 그 결과 6MV에서는 최소 45.27 cGy에서 최대 98.6 cGy, 10MV에서는 최소 53.34 cGy에서 최대 99.66 cGy, 온보드이미지촬영의 경우 최소 0.19 cGy에서 최대 2.64 cGy, 콘빔전산화단층촬영의 경우 최소 0.54 cGy에서 최대 17.18 cGy가 측정되었다. 치료선량에 대한 자세확인촬영 방사선량의 비율은 2차원 영상의 경우 치료 1회당 최대 3.49%, 3차원 영상의 경우 치료 1회당 최대 22.65%의 오차가 발생된다. 따라서 2차원 영상은 1일 1회, 3차원 영상은 1주 1회까지 허용된다. 향후 추가연구 시 실제 임상적용 시에는 환자자세촬영 종류의 병행에 대한 분리계산이 필요하리라 사료된다.

CLINAC 1800 선형가속기의 15 MV X-선의 특성 (Characteristics of 15 MV Photon Beam from a Varian Clinac 1800 Dual Energy Linear Accelerator)

  • 김계준;이종영;박경란
    • Radiation Oncology Journal
    • /
    • 제9권1호
    • /
    • pp.131-141
    • /
    • 1991
  • 국내에서 처음으로 사용되는 CLINAC 1800에서 발생된 15MV X-선의 특성을 구하기 위하여 3 Dimensional water Phantom Dosimetry system)를 이용하여 방사선 치료에 근간이 되는 심부선량 백분율(POD), 최대 조직 비율(TMR), 편평도(beam profile), 대칭도, Wedge인자 등을 측정하였고 선량계산을 위하여 출력 인자들을 구하였다. 1. 선축상 최대치 지점(Dmax)은 SSD 100cm일때 조사면이 $10\times10cm^2$에서 $3.0\pm0.1$ cm이였고 $4\times4cm^2,\;35\times35cm^2$에서 각각 $3.1\pm0.1\;cm,2.2\pm0.1$ cm으로 조사면이 넓어지면서 측정치가 표면에 가까워지는 결과를 보였다. 2. 조직표면 선량(Surface Dose)는 SSD 100cm일때 조사면이 $10\times10cm^2$에서 $15.5\%$이였고 $4\times4cm^2,\;35\times35cm^2$에서 각각 $9.8\%\;,51.2\%$로 조사면이 넓어지면서 표면 선량은 증가하는 결과를 보였다. 3. 심부선량 백분율(PDO)은 SSD 100cm에서 측정하였고 조사면이 $10\times10cm^2$이고 10cm depth에서 $76.8\%$이였고 $80\%,\;50\%$ 선량의 깊이는 각각 $9.1\pm0.1\;cm,19.9\pm0.2\;cm$으로 측정되었다. 4. 최대조직비율(TMR)은 심부선량 백분율(PDD)로부터 계산하였고 측정값과의 차이는 $10\times10cm^2$ 조사면에서 평균 $1\;%$ 이내의 오차를 보였다. 5. 대칭도(symmetry)와 편평도(flatness)는 조사면 $10\times10cm^2$일때 각각 $0.73\%,\;2.72\%$이였다. 6. 출력인자(output factor)는 $10\times10cm^2$ 기준 조사면에서 흡수선량을 1로 하였을때 $4\times4cm^2,\;35\times35cm^2$ 조사면에서는 각각 0.927, 1.087로 측정되었는데 조사면이 증가할수록 흡수량이 증가하는 결과를 보였다. 7. Wedge factor는 $15^{\circ}\;30^{\circ}\;45^{\circ}\;60^{\circ}$를 10cm깊이에서 측정하였는데 0.825, 0.099, 0.560, 0.457로 각각 측정되었고 아크릴 0.4 mm Tray의 투과율은 0.976이였다. 8. 15 MV X-선에 의한 납벽층의 반가층 두께는 13 mm였고 Cerrobend의 반가층은 15.5 mm으로 측정되었다.

  • PDF