• Title/Summary/Keyword: 5G 주파수

Search Result 326, Processing Time 0.028 seconds

Frequency Dependent Electroacupuncture Modulates the Visceromotor Responses to Colonic Distension in TNBS-Induced Colonic Inflammatory Rats (흰쥐의 급성 대장염에 대한 주파수에 따른 전침 효과 연구)

  • Choi, Yun-Young;Yang, Seung-Bum;Ahn, Sung-Hun;Sohn, In-Chu;Kim, Jae-Hyo
    • Korean Journal of Oriental Medicine
    • /
    • v.17 no.3
    • /
    • pp.105-114
    • /
    • 2011
  • Objectives : The transient inflammation has been demonstrated to alter visceral motor response (VMR) and acute mucosal inflammation may precede the manifestation of visceral hyperalgesia in animal models. The purpose of our study is to compare effects of the different frequencies applied electroacupuncture (EA) on acupoints in acute colitis induced by trinitrobenzenesulphonic acid (TNBS). Methods : In Male Sprague-Dawley rats, weighing 250~400g, a single colorectal administration of TNBS (5mg/kg) was made and electrode for electromyography (EMG) recording were stitched into the external oblique musculature. EA of either ST25 or ST36 were applied and stimulation parameter was modulated as follows: 2, 10, or 100 Hz with intensity of 2 mA and 1 ms pulse duration for 30 min. The balloon was inserted intra-anally and VMR to colorectal distension (CRD) was quantified with an EMG recording system. Results : The VMR increased significantly 3 days after TNBS intra-rectal colonic injection in rats. Both 2 Hz and 10 Hz EA on ST36 suppressed VMR to CRD in the acute colitis model but not 100 Hz. Only 10 Hz EA on ST25 suppressed VMR to CRD in the acute colitis. Conclusions : These data show that 10 Hz EA potently inhibits hypersensitivity of colorectum after TNBS induced colitis.

Fabrication and Characterization of 5000V class 4-inch Light Triggered Thyristor (4인치 광점호 Thyristor의 제조 및 특성 분석에 대한 연구)

  • Cho, Doohyung;Won, Jongil;Yoo, Seongwook;Ko, Sangchoon;Park, Jongmoon;Lee, Byungha;Bae, Youngseok;Koo, Insu;Park, Kunsik
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.230-232
    • /
    • 2019
  • Light Triggerd Thyristor (LTT)는 HVDC 및 산업용 스위치 등에 사용되는 대전력 반도체소자이다. 일반적인 Thyristor가 전기적 신호에 의해 trigger 되는 것과는 다르게 LTT는 광신호에 의해 동작하는 소자이다. 본 논문에서는 5,000V, 2,200A 급의 4인치 LTT 소자의 제작 및 전기적인 특성평가 결과를 기술하였다. 4인치 LTT의 구조적인 특징은 전면부 중앙에 광신호가 주입되는 수광부가 위치해 있으며 입력 전류 증폭을 위한 4-단계 증폭 게이트 (gate) 구조를 가지도록 설계하였다. $400{\Omega}{\cdot}cm$ 비저항을 갖는 1mm 두께의 n-형 실리콘 웨이퍼에 boron 이온주입과 열처리 공정으로 약 $30{\mu}m$ 깊이의 p-base를 형성하였으며, 고내압 저지를 위한 edge termination은 VLD (variable lateral doping) 기술을 적용하였다. 제작된 4인치 LTT는 6,500 V의 순방향 항복전압 ($V_{DRM}$) 특성을 나타내었으며, 100V의 어노드전압 ($V_A$)과 20 mA의 게이트전류 ($I_G$)에 의하여 thyristor가 trigger 됨을 확인하였다. 제작한 LTT 소자는 disk형 press-pack 패키지를 진행한 후, LTT의 수광부에 $10{\mu}s$, 50 mW의 900 nm 광 펄스를 조사하여 전류 특성을 평가하였다. LTT 패키지 샘플에 60 Hz 주파수의 광 펄스를 조사한 경우 2,460 A의 순방향 평균전류 ($I_T$)와 $336A/{\mu}s$의 반복전류상승기울기 (repetitive di/dt)에 안정적으로 동작함을 확인하였다. 또한, 펄스 전류 시험의 경우 61.6 kA의 최대 통전 전류 (ITSM, surge current)와 $1,050A/{\mu}s$의 펄스전류 상승 기울기 (di/dt of on-state pulse current)에도 LTT의 손상 없이 동작함을 확인하였다.

  • PDF

A study on scheme for activating active elements in RIS aided wireless communication system (RIS를 활용한 무선 통신 시스템에서 능동 반사 소자를 활성화하는 기법에 관한 연구)

  • Jinsoo Bae;Seung-Geun Yoo;Hyoung-Kyu Song
    • Journal of IKEEE
    • /
    • v.27 no.4
    • /
    • pp.425-429
    • /
    • 2023
  • In this paper, the scheme to activate the active elements of reconfigurable intelligent surface(RIS) is proposed. Recently, RIS has been studied as a technology that improves communication coverage and spectral efficiency in wireless communication system. RIS can adjust the phase and amplitude of the received signal, and can ensure better communication performance in areas with many obstacles, such as urban areas. However, due to RIS, the signal undergoes fading twice and performance decrease in communication. Recently, RIS using active reflection elements has been studied to solve these problems. However, if the entire RIS is used as an active reflection element, energy consumption increases. Accordingly, in this paper, we propose a system that utilizes some of the RIS reflective elements as active reflective elements and a scheme for selecting active reflective elements to be activated.

Surface treatment of polysaccharide by flexible active species generator (플렉서블 활성종 발생기를 이용한 다당류 표면처리)

  • Lee, Yu-Ri;Lee, Seung-Hun;Kim, Do-Geun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.39-39
    • /
    • 2018
  • 최근 플라즈마 의학이 발달하면서 제트, 펜, 니들, 토치 등의 다양한 형태의 플라즈마 발생기가 개발되었으며 내부의 가스라인으로 가스의 종류, 유속, 조성 등을 조절하여 생물학적 효과를 극대화 할 수 있고 안정적으로 플라즈마 방전상태를 유지할 수 있으나 처리 면적이 좁아 실제 생물학적 시스템 (세포, 조직, 그리고 박테리아) 적용에 있어 한계점이 존재한다. 이러한 한계점을 극복하기 위해서 유전체격벽방전 (Dielectric barrier discharge, DBD) 방식을 이용한 플렉서블 활성종 발생기를 제작하고 생물학적 시스템에 적용하기 위한 방전 특성 평가를 진행하였으며, 간단한 in vitro 모델인 한천 젤을 이용하여 플라즈마 처리에 따른 전달물질의 침투거리를 확인하였다. 플라즈마 방전 시 생성되는 수산화기 [OH], 과산화수소 [$H_2O_2$], 초산소음이온 [$O_2{^-}$], 오존 [$O_3$], 그리고 산화질소 [$NO_x$]와 같은 산소 및 질소 활성종 (Reactive oxygen and nitrogen species, RONS)은 세포벽 또는 세포막의 주요 구성성분인 다당류와 인지질의 과산화 반응을 통해 구조를 변화시키고 생물학적 시스템의 표면의 pH를 낮춘다. 이러한 RONS의 작용은 살균, 소독 뿐만 아니라 약물의 침투를 돕는다. 일반적으로 한천 겔은 농도에 따라 생체 내 뇌 조직과 물리적 특성이 유사하고, 미생물학 기질, 방사선학 연구를 위한 조직모델로 사용되기 때문에 본 연구에서는 3%와 5% 농도의 한천 젤을 사용하여 침투거리를 확인하였다. 한천 젤은 $2.5{\times}2.5{\times}2.5cm^3$의 크기로 준비되었고 대조군으로 염료가 포함된 에멀젼을 0.01 g 도포하고, 실온에서 30분간 보존 후 단면을 잘라 현미경으로 침투거리를 확인하였으며, 실험군으로 플라즈마 전처리 후 에멀젼을 도포한 시표와 에멀젼 도포 후 플라즈마 처리한 시료에 대해 에멀젼 침투거리의 변화를 확인하였다. 본 연구의 플렉서블 활성종 발생기는 인체에 부착하여 사용되기 때문에 화상, 홍반을 유발을 방지하기위해 $40^{\circ}C$의 온도에서 실험을 진행하였고 이때에 플라즈마 방전조건은 $0.065W/cm^2$ 수준의 전력을 소모하는 1.7 kV의 전압, 16 kHz의 주파수로 10분간 처리하였다. 그 결과 3%의 한천 젤의 경우 침투거리 0.779 mm에서 0.826 mm, 0.942 mm까지 침투거리가 증가하였고 5%의 한천 젤의 경우 0.859 mm, 0.949 mm로 증가하였다. 이러한 침투거리 증가는 젤 표면의 다당류를 구성하고 있는 단량체가 플라즈마 처리시 화확적 구조가 끊어져 결론적으로 약물 침투가 증가된 것으로 판단된다.

  • PDF

Development of Trimming Technology in High-fine Resistor Using U.V. Laser (자외선 레이저를 이용한 고정밀 저항체 가공기술 개발)

  • Noh, S.S.;Kim, D.H.;Chung, G.S.;Kim, H.P.;Kim, K.H.
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.358-364
    • /
    • 2002
  • In this paper, we used U.V.(wavelength, 355nm) laser for adjusting Pt thin films temperature sensor to $100{\Omega}$ at $0^{\circ}C$. Internationally, A-class tolerance of temperature sensor is $0.06{\Omega}$ at $0^{\circ}C$. This is under value of $0.15^{\circ}C$, actually, so high-fine trimming technology is essential to this process. The width of trimmed lines was about $10{\mu}m$ and the best trimming of Pt thin films of $1{\sim}1.5{\mu}m$ was carried out with power : 35mW, rep. rate frequency : 200Hz and bite size : $1.5{\mu}m$. And using photolithography process, 96 resistors were fabricated in $2"{\times}2"$ substrate as the proportion of $79{\sim}90{\Omega}$ and $91{\sim}102{\Omega}$ is 42.7% and 57.3%, respectively. As result of trimming resistors to the target value of $109.73{\Omega}$ at $25^{\circ}C$, 82.3% of resistors had the tolerance within ${\pm}0.30{\Omega}$ and the others(17.7%) were within ${\pm}0.06{\Omega}$ of A-class tolerance.

Human Effect for Commercial Wireless Power Transfer System Operating at Low Frequency (상용 자기유도방식 무선전력전송 시스템의 인체영향 분석)

  • Kang, Jun-Seok;Lee, Seungwoo;Hong, Ic-Pyo;Cho, In-Kui;Kim, Nam
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.5
    • /
    • pp.382-390
    • /
    • 2017
  • In this paper, we consider particular exposure scenarios to evaluate human effects for inductive commercial wireless charging device operating at low frequency. The coil used in this study is the A10 model in Qi standard proposed by WPC(Wireless Power Consortium), and input power is 5 W to the operating frequency of 155 kHz. In perfectly aligned condition, the max leakage magnetic field is $257.58{\mu}T$ which is obtained at the side of the device, and it is exceeded about 7.4 times of the ICNIRP 1998 reference level. The SAR is evaluated with homogeneous phantom which has electric constants of wet skin. The max value of the SAR is $134.47{\mu}W/kg$ which is obtained at the side of the device also, and it is much lower than the international guidelines. Especially, it showed higher SAR values in case of misalignment condition, so we will need to consider the misalignment condition importantly when we evaluate human effects for wireless power transfer system.

Magnetoresistive Effect in Ferromagnetic Thin Films( I ) (강자성체 박막(Fe-Ni, Co-Ni)의 자기-저항 효과에 관한 연구( I ))

  • Chang, C.G.;Yoo, J.Y.;Song, J.Y.;Yun, M.Y.;Park, J.H.;Son, D.R.
    • Journal of Sensor Science and Technology
    • /
    • v.1 no.1
    • /
    • pp.23-34
    • /
    • 1992
  • In order to fabricate magnetoresistive sensor, Fe-Ni and Co-Ni alleys were evaporated on the slide glass and the silicon wafers. Saturation magnetic induction($B_{s}$), coercive field strength($H_{c}$) and magnetoresistance were measured for fabricated samples. The evaporated Fe-Ni thin films show that the saturation magnetic induction was 0.65 T, and coercive field strength was 0.379 A/cm, and this value was changed to 0.370 A/cm(//), 0.390 A/cm(${\bot}$), respectively after magnetic annealing. For the measurement of coercive field strength, magnetizing frequency of 1 kHz was used. For the fabricated sensor element, the change of magnetoresistance (${\Delta}R/R$) was excessively unstable due to oxidation in the process of fabrication. The evaporated Co-Ni alloy thin films show that saturation magnetic induction was 0.66 T, and coercive field strengthes were 5.895 A/cm(//), 5.898 A/cm(${\bot}$), respectively, after magnetic annelaing. The change of magnetoresistance(${\Delta}R/R$) was $3.6{\sim}3.7%$ of which value was excessively stable to room temperature. Fe-Ni thin film could have many problems due to large affinity in the process of fabrication of magnetoresistance sensor, but Co-Ni thin film could be a suitable material for fabrication of magnetoresistance sensor, because of its small affinity and definite magnetoresistance effects.

  • PDF

중력이상을 이용한 한반도 모호면 추출에 관한 연구

  • 김정우;조진동;김원균;민경덕;황재하;이윤수;박찬홍;황종선
    • Proceedings of the KSEEG Conference
    • /
    • 2003.04a
    • /
    • pp.258-264
    • /
    • 2003
  • 중력이상 및 수치고도모델을 이용하여 한반도 모호면 심도를 추출하였다 중력이상값은 인공위성고도레이더 관폭값을 주로 이용한 전지구 모델을 이용하여 데이터영역 뿐 만 아니라 주파수영역에서도 자료의 균질성을 확보하였다. 모호면 추출은 Kim et al. [2000a]에 의해 제안된 스펙트럼 대비법 및 후리에급수를 이용한 파워스펙트럼분석법을 이용하였다. 전자는 지각근형을 전제로, 지형에 의한 중력효과와 후리에어 중력이상을 파동수영역에서 대비하여 모호면의 심도를 계산하는 방법이고, 후자는 완전부우게 중력이상으로부터 푸리에변환을 이용하여 지하 밀도 변화층의 심도를 계산하는 방법이다. 이 두 모호면은 서로 0.53의 상관관계를 갖고 있으며, 이는 모호면 산출의 방법론적인 차이 및 계산상의 오차인 것으로 사료된다. 이렇게 두 가지 독립적인 방법으로 추출된 모호면을 하나로 통합하기 위한 한 방법으로, 두 모호면의 차이를 계산한 후, 이를 최소자승법을 이용, 두 모호면을 보정하였다. 결과적으로 한반도의 최종 모호면의 평균심도는 32.0km, 표준편차는 2.5km 이며, 최소, 최대 심도는 20.3, 36.6km으로 나타났다. 이 경우 지형에 의한 중력효과는 스펙트럼대비법에 의해 제거된 결과이나, 한반도의 지각이 완전한 지각판 내에 놓여 있어서 Airy-Heiskanin 지각균형설의 가정이 타당성이 있는가, 혹은 국부적인 응력장에 의해 한반도의 지각이 과연 얼마나 지지되고 있는가 하는 것에 대한 추가적인 연구가 필요하며, 이에 앞서, 일정한 밀도차를 갖는 연속적인 밀도변화층이 존재한다는 가정이 반드시 필요하다.에는 관련성을 갖고 있으며, 이는 유류 분해정도를 파악하는 지시자로써 특정 무기 오염물질을 이용할 수 있을 가능성이 있으므로 좀더 이들 관계성에 대한 연구가 진행될 필요성이 있다고 판단된다.고 과학적으로 분석할 수 있는 방법이 될 수 있을 것으로 기대된다. 의미를 되새기는 것으로 짧은 연구를 시작하겠다. 등은 활성 값이 70% 이상으로 퇴적물 독성이 상대적으로 낮았다. 이중나선 DNA 함량은 28.4 % - 49%로 대조군에 비해서 감소가 크다. 대부분의 정점이 대조군의 30% 내외로 정점 간의 차이는 크지는 않다. 그러나 다른 측정자료와 같이 정점 22에서 18%로 최소치를 나타내고, 정점 2, 12에서 20% 내외의 값을 보인다. 종합적으로 볼 때 오염물질의 유입이 크고, 광양제철 인근 정점 들이 모두 다른 정점에 비해서 낮아서, 퇴적물 독성이 높은 정점으로 조사되었다.hiwo의 광합성 능력은 낮은 농도들에서는 대조구와 유사하였으나, 5 $\mu\textrm{g}$/l의 높은 농도에서는 초기에 매우 낮은 광합성 능력을 보이다가 시간이 경과하면서 대조군보다 더 높은 경향을 나타냈다. 이러한 결과는 식물플랑크톤이 benso[a]pyrene의 낮은 농도에서 노출될 때는 이 물질을 탄소원으로 사용할 가능성이 있음을 시사한다. 본 연구의 결과들은 연안해역에 benso[a]pyrene과 같은 지속성 유기오염물질이 유입되었을 때 내정여부에 따라 식물플랑크톤 군집내 종 천이와 일차생산력에 크게 영향을 미칠 수 있음을 시사한다.TEX>5.2개)였으며, 등급별 회수율은 각각 GI(8.5%), GII

  • PDF

Comparison of Ultrasound Image Quality using Edge Enhancement Mask (경계면 강조 마스크를 이용한 초음파 영상 화질 비교)

  • Jung-Min, Son;Jun-Haeng, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.157-165
    • /
    • 2023
  • Ultrasound imaging uses sound waves of frequencies to cause physical actions such as reflection, absorption, refraction, and transmission at the edge between different tissues. Improvement is needed because there is a lot of noise due to the characteristics of the data generated from the ultrasound equipment, and it is difficult to grasp the shape of the tissue to be actually observed because the edge is vague. The edge enhancement method is used as a method to solve the case where the edge surface looks clumped due to a decrease in image quality. In this paper, as a method to strengthen the interface, the quality improvement was confirmed by strengthening the interface, which is the high-frequency part, in each image using an unsharpening mask and high boost. The mask filtering used for each image was evaluated by measuring PSNR and SNR. Abdominal, head, heart, liver, kidney, breast, and fetal images were obtained from Philips epiq5g and affiniti70g and Alpinion E-cube 15 ultrasound equipment. The program used to implement the algorithm was implemented with MATLAB R2022a of MathWorks. The unsharpening and high-boost mask array size was set to 3*3, and the laplacian filter, a spatial filter used to create outline-enhanced images, was applied equally to both masks. ImageJ program was used for quantitative evaluation of image quality. As a result of applying the mask filter to various ultrasound images, the subjective image quality showed that the overall contour lines of the image were clearly visible when unsharpening and high-boost mask were applied to the original image. When comparing the quantitative image quality, the image quality of the image to which the unsharpening mask and the high boost mask were applied was evaluated higher than that of the original image. In the portal vein, head, gallbladder, and kidney images, the SNR, PSNR, RMSE and MAE of the image to which the high-boost mask was applied were measured to be high. Conversely, for images of the heart, breast, and fetus, SNR, PSNR, RMSE and MAE values were measured as images with the unsharpening mask applied. It is thought that using the optimal mask according to the image will help to improve the image quality, and the contour information was provided to improve the image quality.

Immuno-regulatory Activities of Various Fractions from Ehpedrae Sinica STAPF, Rubus Coreanus Miq. and Angelica gigas Nakai Extracts with Ultrasonification (초음파 병행 추출을 이용한 마황과 복분자, 당귀 분획물의 면역활성 조절 효과)

  • Kim, Jung-Hwa;Kim, Dae-Ho;You, Jin-Hyun;Kim, Cheol-Hee;Kwon, Min-Chul;Seong, Nak-Sul;Lee, Seung-Eun;Lee, Hyeon-Yong
    • Korean Journal of Medicinal Crop Science
    • /
    • v.13 no.4
    • /
    • pp.161-170
    • /
    • 2005
  • This study was performed to examine immuno-regulatory activities of Ehpedrae Sinica STAPF, Rubus Coreanus Miq. and Angelica gigas Nakai extracts in conbination with ultrasonification. The extract yields of plants were the highest in the extraction system of $60^{\circ}C$ and 40 kHz of ultrasonification. The immune cell growth ratio of human immune B and T cells was increased compared to other fractions by the water fraction of the plants at $60^{\circ}C$ and 40 kHz. The water fractions of the plants at $60^{\circ}C$ and 40 kHz increased the specific secretion of IL-6 and $TNF-{\alpha}$ of human immune B and T cells compared to other fractions of the plants. The water fraction of Ehpedrae Sinica STAPF among the plants was observed to show the highest specific secretion of IL-6 and $TNF-{\alpha}$. Also, NK-92 MI cells growth was increased in adding the water fractions of the plants at $60^{\circ}C$ and 40 kHz. The water fraction of Ehpedrae Sinica STAPF among the plants showed the highest in NK-92 MI cell growth ratio. The differentiation activity of the HL-60 cells significantly increased in adding the water fraction of Ehpedrae Sinica STAPF compared to other fractions of the plants. These results suggest that the water fractions of the plants in extraction system of temperature $60^{\circ}C$ and ultrasonification 40 kHz have marked useful immuno-stimulatory activities.