• Title/Summary/Keyword: 50 Up in Peak

Search Result 194, Processing Time 0.025 seconds

Distance Measurement by Automatic Peak Detection for Indoor Positioning Using Spread Spectrum Ultrasonic Waves

  • Suzuki, Akimasa;Miyara, Yasuaki;Iyota, Taketoshi;Kim, Young-Bok;Choi, Yong-Woon
    • Journal of Power System Engineering
    • /
    • v.19 no.2
    • /
    • pp.33-39
    • /
    • 2015
  • In conducting indoor positioning by code division multiple access using spread spectrum ultrasonic waves, it is required to detect signals under the influence of near-far problem occurred by difference on signal power, caused by distance between transmitter and receiver. For discussing robustness to the problem, we verified measuring accuracy on distance from an experiment on a real space with a hardware device where our proposed method is mounted. The proposed method performs automatic signal detection by setting threshold level dynamically. As an experimental result, measurable distance were improved by the proposed method, and measurement errors were up to 50mm in distances from 1000mm to 6000mm; therefore, enough accuracy to realize self-localization or navigation for autonomous mobile robot or human was obtained.

Prevalence of Thyroid Disfunction in the Subjects for the Health Check-up (건강검진자를 대상으로한 갑상선질환의 유병률 조사)

  • Seok, Seong-Ja;Shin, Du-Man
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.39 no.2
    • /
    • pp.96-103
    • /
    • 2007
  • This study was carried out on 14,443 subjects (8,706 men, 5,737 women ; between 20-80 years of age, mean age $41.8{\pm}9.16$) who visited the health promotion center of one university hospital. Serum $T_3$, $T_4$ and TSH concentrations were measured with CIA using commercial kits on ADVIA Centaur Assay. The prevalence of thyroid disfunction was high in elderly people and women like in western countries. The results were as follows; 1. The prevalence of overt hyperthyroidism was 4.8/1,000 population (men 4.1/1,000, women 5.9/1,000) and was higher in women than in men. 2. The prevalence of subclinical hyperthyroidism was 10.7/1,000 population (men 9.0/1,000, women 13.2/1,000) with peak prevalence at the age group 50, 60 and was higher in women than in men. 3. The prevalence of overt hypothyroidism was 0.5/1,000 population (men 0.5/1,000, women 0.5/1,000). The prevalence increased with age and was significantly higher in women in the age group over 60 years. 4. The prevalence of subclinical hypothyroidism was 12.6/1,000 population (men 6.0/1,000, women 22.7/1,000) and was as high as about 4 times in women than in men. 5. The prevalence of thyroid dysfunction was higher in women than in men in all the age groups, and was higher in the age group 50, 60 years than in any other age group.

  • PDF

Characteristics of wind loads on roof cladding and fixings

  • Ginger, J.D.
    • Wind and Structures
    • /
    • v.4 no.1
    • /
    • pp.73-84
    • /
    • 2001
  • Analysis of pressures measured on the roof of the full-scale Texas Tech building and a 1/50 scale model of a typical house showed that the pressure fluctuations on cladding fastener and cladding-truss connection tributary areas have similar characteristics. The probability density functions of pressure fluctuations on these areas are negatively skewed from Gaussian, with pressure peak factors less than -5.5. The fluctuating pressure energy is mostly contained at full-scale frequencies of up to about 0.6 Hz. Pressure coefficients, $C_p$ and local pressure factors, $K_l$ given in the Australian wind load standard AS1170.2 are generally satisfactory, except for some small cladding fastener tributary areas near the edges.

Study on the Thermal Properties of the Gamma-ray Irradiated EVA/MWCNT Nanocomposites

  • Lee, Kyoung-Yong;Kim, Ki-Yup;Hwang, In-Ra
    • Journal of Radiation Industry
    • /
    • v.3 no.1
    • /
    • pp.31-37
    • /
    • 2009
  • This paper describes the preparation of manufacturing a new nanocomposite material, which involves adding a multi walled carbon nanotube (MWCNT) to improve thermal characteristics of poly (ethylene-co-vinyl acetate) (EVA). We irradiated the prepared nanocomposites with doses of 50 kGy, 100 kGy and 200 kGy at a dose rate of $5kGy\;hr^{-1}$ and examined their thermal stability, activation energy and crosslink level by using a thermogravimetric analyzer (TGA) and gel fraction experiments. TGA results indicated that the samples with a MWCNT had higher Derivative Thermo Gravimetry (DTG) 2nd peak temperatures than those without a MWCNT. And activation energy of the samples reduced as the absorption dose and the MWCNT content increased. Finally, the gel fraction increased rapidly up to 100 kGy as total absorption dose increased, and then the growth rate of all samples was slowly increased from 100 kGy.

CMOS Rectifier for Wireless Power Transmission Using Multiplier Configuration (Multiplier 설정을 통한 무선 전력 전송 용 CMOS 정류 회로)

  • Jeong, Nam Hwi;Bae, Yoon Jae;Cho, Choon Sik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.12
    • /
    • pp.56-62
    • /
    • 2013
  • We present a rectifier for wireless power transmission using multiplier configuration in layout for MOSFETs which works at 13.56 MHz, designed to fit in CMOS process where conventionally used diodes are replaced with the cross-coupled MOSFETs. Full bridge rectifier structure without comparators is employed to reduce current consumption and to be working up to higher frequency. Multiplier configuration designed in layout reduces time delay originated from parasitic series resistance and shunt capacitance at each finger due to long connecting layout, leading to fast transition from on-state to off-state cross-coupled circuit structure and vice versa. The power conversion efficiency is significantly increased due to this fast transition time. The rectifier is fabricated in $0.11{\mu}m$ CMOS process, RF to DC power conversion efficiency is measured as 86.4% at the peak, and this good efficiency is maintained up to 600 MHz, which is, to our best knowledge, the highest frequency based on cross-coupled configuration.

A Methodology for the Estimation of Design Flood of a Small Watershed (소하천유역(小河川流域)의 계획홍수량(計劃洪水量) 산정방법(算定方法)의 개발(開發))

  • Yoon, Yong Nam;Ahn, Tae Jin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.4 no.1
    • /
    • pp.103-112
    • /
    • 1984
  • This study is an effort to develop a series of empirical procedure for the determination of design flood for a small watershed based on the unit hydrograph theory. It is shown that a flood discharge of a watershed with a specific return period can be expressed as a product of its watershed area, rainfall factor, runoff factor and flood peak reduction factor. Since the procedures for the determination of rainfall factor and runoff factor were already developed in the previous study (13) a series of step-by-step procedure is devised to empirically determine the flood peak reduction factor in the present study. Using the methodology developed herein the 50-year design flood, which is of concern in the drainage of agricultural lands, is estimated for a watershed on upper Kyungan River and compared with the design floods by the existing methods now in use. The flood peak reduction factor was correlated with the dimensionless parameter consisted of the rainfall duration divided by the basin lag time, which was computed from the derived unit hydrographs by the method of moment. The unit hydrographs of various durations were synthesized by the method of build up and S-curve. A multiple correlation was also made between the basin lag time and the physiographic parameters of the watershed, i.e., the stream length and the average stream slope.

  • PDF

Developmental Changes in Digestive Enzymes Activity of Black Rockfish Sebastes inermis (볼락, Sebastes inermis 자.치어의 성장에 따른 소화효소 활성 변화)

  • Gwak Woo-Seok;Park Dae-Won
    • Journal of Aquaculture
    • /
    • v.19 no.2
    • /
    • pp.125-132
    • /
    • 2006
  • Black rockfish larvae and juveniles were reared for 95 days after parturition (DAP) in order to determine four enzyme activities (trypsin, pepsine-like enzyme, lipase, amylase) during ontogeny. Larvae were fed rotifers Brachionus plicatilis from 1 to 25 DAP, Artemia nauplii from 10 to 78 DAP and then gradually changed to pelleted feed from 30 DAP. Temperature was kept between $13.5{\sim}14.9^{\circ}C$. Trypsin and lipase activities were found in 2 DAP larvae ($7.0{\pm}1.5$ unit and $4.5{\pm}1.4$ unit, $mean{\pm}SD$, respectively). The evolution of both enzymes activities showed a profile marked by drastic increases between postflexion and juvenile stage. There is an increment on specific trypsin activity at 10 DAP, corresponding with the beginning of Artemia feeding. Pepsin-like enzyme activity was found at 11 DAP and increased drastically from 56 DAP, cor-responding with the initiation of juvenile stage. Amylase activity was also found at 11 DAP and maintained at a low level up to 38 DAP followed by a drastic increase from 39 DAP to 50 DAP. Considering our results of both trypsin and pepsin-like enzyme activities, it might be concluded that higher somatic growth of Sebastes inermis could be possible with the initiation juvenile of stage and the early juvenile stage is a suit-able period for feeding an artificial diet for fish.

Effect of Seeding Rate (Sheep fescue 50% + Wildflowers 50%) on the Growth Characteristics, Seasonal Anthesis Distribution and Botanical Composition in Wildflower Pastures (쉽 페스큐(50%)와 야생화(50%)의 파종비율이 야생화초지의 생육특성, 계절개화분포 및 식생변화에 미치는 영향)

  • Lee, Byong-Chul;Lee, In-Duk;Lee, Hyung-Suk;Do, Chang-Hee
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.30 no.4
    • /
    • pp.291-300
    • /
    • 2010
  • This study was carried out in the Chungnam National University grassland experimental field from October, 2007 to December, 2009 in order to find out the growth characteristics of the wildflowers, the seasonal anthesis distribution of the wildflowers and the botanical composition of the wildflowers which were altogether composed of 50% sheep fescue and 50% wildflowers. The experimental species contained 34 species in total consist of sheep fescue (fundamental turfgrass), 4 native wildflowers, and 29 introduced wildflowers belonged. At the time of the anthesis of the wildflowers, the average length was 30.0 cm one year later and 35.6 cm two years later. They bloomed out into ten colors, but into simplified colors during August, September, and October. The peak of the blooming was May and June and blooming pattern leant from August to October. Especially, at the age of two (2009) the color, seasonal distribution, and consistency emerged as problems owing to the reduction of annual wildflowers after winterization. The annual botanical composition of wildflowers, sheep fescue, and weed came to 28%, 55%, and 17% each one year later (2008) and 24%, 60%, and 17% each two years later (2009). Based on this result, cultivating wildflower grassland (sheep fescue 50% + wildflowers 50%) is the proper method for making up such flatlands as parks and riversides in a short period (one year) for the purpose of commanding a fine view.

Impacts of Pre-transplant Panel-Reactive Antibody on Post-transplantation Outcomes: A Study of Nationwide Heart Transplant Registry Data

  • Darae Kim;Jin-Oh Choi;Yang Hyun Cho;Kiick Sung;Jaewon Oh;Hyun Jai Cho;Sung-Ho Jung;Hae-Young Lee;Jin Joo Park;Dong-Ju Choi;Seok-Min Kang;Myoung Soo Kim;Jae-Joong Kim
    • Korean Circulation Journal
    • /
    • v.54 no.6
    • /
    • pp.325-335
    • /
    • 2024
  • Background and Objectives: The number of sensitized heart failure patients on waiting lists for heart transplantation (HTx) is increasing. Using the Korean Organ Transplantation Registry (KOTRY), a nationwide multicenter database, we investigated the prevalence and clinical impact of calculated panel-reactive antibody (cPRA) in patients undergoing HTx. Methods: We retrospectively reviewed 813 patients who underwent HTx between 2014 and 2021. Patients were grouped according to peak PRA level as group A: patients with cPRA ≤10% (n= 492); group B: patients with cPRA >10%, <50% (n=160); group C patients with cPRA ≥50% (n=161). Post-HTx outcomes were freedom from antibody-mediated rejection (AMR), acute cellular rejection, coronary allograft vasculopathy, and all-cause mortality. Results: The median follow-up duration was 44 (19-72) months. Female sex, re-transplantation, and pre-HTx renal replacement therapy were independently associated with an increased risk of sensitization (cPRA ≥50%). Group C patients were more likely to have longer hospital stays and to use anti-thymocyte globulin as an induction agent compared to groups A and B. Significantly more patients in group C had positive flow cytometric crossmatch and had a higher incidence of preformed donor-specific antibody (DSA) compared to groups A and B. During follow-up, group C had a significantly higher rate of AMR, but the overall survival rate was comparable to that of groups A and B. In a subgroup analysis of group C, post-transplant survival was comparable despite higher preformed DSA in a desensitized group compared to the non-desensitized group. Conclusions: Patients with cPRA ≥50% had significantly higher incidence of preformed DSA and lower freedom from AMR, but post-HTx survival rates were similar to those with cPRA <50%. Our findings suggest that sensitized patients can attain comparable post-transplant survival to non-sensitized patients when treated with optimal desensitization treatment and therapeutic intervention.

A Study on Typical Rates of Water-use for Primary School, Middle School and High School Facilities (초.중.고등학교 시설의 급수 사용량에 대한 연구)

  • Kim, Kyu-Saeng
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.12
    • /
    • pp.802-807
    • /
    • 2008
  • A Study on Typical Rates of Water-use for School Facilities has been carried out in this work. Water supply system is given much weight in school facilities. Therefore, it set up a basis efficiency using of water sources to calculate typical rates of water use. The results are summarized as follows; 1) On the whole, typical rates of water-use was founded out 15 L/stu. d in pirmary school, 10 L/stu. d in middle school and 30 L/stu. d in high school smaller than the existing it. It was rate of water-use change as season and Max. Rates of water-use was July. 2) I deem that school hours are 5 hour's in primary school, 7 hour's in middle school and 8 hour's in high school. It the concept of 1 hour that is lesson time 40 minutes and resting time 10 minutes in primary school, lesson time 45 minutes and resting time 10 minutes in middle school and lesson time 50 minutes and resting time 10 minutes in high school. 3) It is desired that we calculate the volume of pump and water tank throughout this concept and the size of water tank should be 1.5 times with taking peak load into consideration by this study on typical rate of water-use. 4) The amount of using water increases in gradually and I consider the life cycle of facilities is more than 10 years. As a result, I can forecast that the size will be insufficiency but I deem that if we devise a plan about parallel pumping on water tank space, we can cope with it. Also, it is expected that we can cut back the transport energy by controlling pump volume.