• 제목/요약/키워드: 5급 와동

검색결과 82건 처리시간 0.023초

쐐기 형태의 5급와동에서 수복재료에 따른 변연 미세누출의 비교 (COMPARISON OF MARGINAL LEAKAGE OF WEDGE-SHAPED CLASS V CAVITY ACCORDING TO RESTORATIVE MATERIALS)

  • 장현주;이희주;허복
    • Restorative Dentistry and Endodontics
    • /
    • 제25권1호
    • /
    • pp.56-62
    • /
    • 2000
  • The purpose of this study was to assess the effects of restorative materials on the marginal leakage of wedge-shaped class V cavity. The study was performed in vitro in 25 defect-free permanent, extracted teeth. Wedge-shaped class V cavities were prepared and then the teeth were randomly selected and restored according to the following. Group A : restoration with Tetric Ceram(composite resin) Group B : restoration with Tetric flow(flowable resin) Group C : restoration with Compoglass after acid etching(compomer) Group D : restoration with Compoglass(compomer) Group E : restoration with Fuji II LC improved(resin-modified GIC) After thermocycling, the specimens were immersed in 5% basic fuchsin solution for 6 hours and sectioned longitudinally through the center of the restoration. The degree of marginal leakage was measured as the extent of dye penetration under the stereomicroscope. The data were analysed using one-way ANOVA. When significant differences found, multiple comparisons were made using Duncan's Multiple Range Test. The results were as follows: 1. The occlusal margins of all groups except for Fuji II LC improved showed lesser leakage than gingival margins and there was statistically significant difference(p<0.05). 2. At the occlusal margins, group A, B showed same marginal leakage scores, and others were decreased as group C, D, E in that order. There were statistically significant difference between group A, Band group D, E, group C and group E(p<0.05). 3. At the gingival margins, group B, C showed same marginal leakage scores, and others were decreased as group A, D, E in that order. But there was statistically significant difference between group B, C and group E(p<0.05). 4. In the Compoglass restoration, acid-etching technique was beneficial for marginal sealing ability at all of margins. But there was no statistically significant difference (p>0.05). In the restorations for wedge-shaped class V cavities, resin restoration with acid etching technique is recommended.

  • PDF

V 급 와동 변연부 형태 및 복합레진 종류에 따른 변연 누출에 관한 실험적 연구 (An Experimental Study on the Effects of the Margin Designs and Composite Resins on the Marginal Leakage of Class V Resin Restorations)

  • 신용필;이찬영;이승종;이정석
    • Restorative Dentistry and Endodontics
    • /
    • 제12권1호
    • /
    • pp.107-116
    • /
    • 1986
  • The primary aim of this study was to assess the effects of the margin designs and composite resins on the marginal leakage of Class V resin restorations. 60 Class V cavities with $90^{\circ}$ butt joint, 60 with $45^{\circ}$ bevel joint, and 60 with concave joint were prepared on the labial surfaces of 38 extracted anterior teeth and the buccal and lingual surfaces of 71 premolars, and classified as the butt group, bevel group and concave group, respectively. After completion of the cavity preparation, Heliosit${(R)}$ was filled in 20 butt joint cavities, 20 bevel joint cavities, and 20 concave cavities. And Hi-Pol$^{(R)}$ and Palfique$^{(R)}$ were filled in the same manner, respectively. After finishing, all specimens were subjected manually to 50 thermal cycles at $4^{\circ}C$, $37^{\circ}C$, and $60^{\circ}C$. They were immersed in 0.5% methylene blue solution for 24 hours, and buccolingually sectioned with sectioning machine. The sectioned specimens were examined under the light microscope. The results indicated the following: 1. The bevel group showed the least amount of marginal leakage compared with the other two design groups, but the statistical analysis showed no significant difference at the 95% confidence level. 2. Hi-Pol$^{(R)}$ group showed the most severe marginal leakage compared with the other composite resin materials, but there was no significant difference in the groups. 3. The bevel-Heliosit$^{(R)}$ subgroup, which was filled with Heliosit$^{(R)}$ in the beveled cavities, showed the least amount of marginal leakage, but there was no significance in all the subgroups.

  • PDF

제 5급 와동에서의 단일용기 상아질 접착제와 자가 산부식 접착제의 상아질에 대한 침투도 평가 (A CONFOCAL MICROSCOPIC STUDY ON DENTINAL INFILTRATION OF ONE-BOTTLE ADHESIVE SYSTEMS AND SELF-ETCHING PRIMING SYSTEM BONDED TO CLASS V CAVITIES)

  • 김형수;박성호
    • Restorative Dentistry and Endodontics
    • /
    • 제27권3호
    • /
    • pp.257-269
    • /
    • 2002
  • Objective : The purpose of this study was to evaluate the resin infiltration into dentin of one-bottle adhesive systems and self-etching primer bonded to Class V cavities using confocal laser scanning microscope(CLSM). Material and Methods : Forty Class V cavities were prepared from freshly extracted caries-free Human teeth. These teeth were divided into two groups based on the presence of cervical abrasion: Group I, cervical abrasion : Group II, wedge-shaped cavity preparation. Resin-dentin interfaces were produced with two one-bottle dentin bonding systems-ONE COAT BOND(OCB; Coltene$^R$) and Syntac$^R$SPrint$^{TM}$(SS; VIVADENT)-, one self-etching priming system-CLEARFIL$^{TM}$ SE BOND (SB : KURARAY)- and one multi-step dentin bonding system-Scotchbond$^{TM}$Multi-Purpose (SBMP, 3M Dental Products)-as control according to manufacturers' instructions. Cavities were restored with Spectrum$^{R}$(Dentsply). Specimens were immersed in saline for 24 hours and sectioned longitudinally with a low-speed diamond disc. The resin-dentin interfaces were microscopically observed using CLSM. The quality of resin-infiltrated dentin layers were evaluated by five dentists using 0~4 scale. Results : Confocal laser scanning microscopal investigations using primer labeled with rhodamine B showed that the penetration of the primer occurred along the cavity margins. Statistical analysis using one-way ANOVA followed by Duncan's Multiple Range test revealed that the primer penetration of the group 2(wedge-shaped cavity preparation) was more effective than group 1(cervical abrasion) and that of the gingival interfaces was more effective than the occlusal interfaces. In the one-bottle dentin bonding systems, the resin penetration score of OCB was compatible to SBMP, but those of SS and self-etching priming system, SB were lower than SBMP.

컴포머의 수화팽창에 관한 연구 (A STUDY ON THE HYGROSCOPIC EXPANSION OF COMPOMER)

  • 박경진;김종수;권순원
    • 대한소아치과학회지
    • /
    • 제29권1호
    • /
    • pp.11-18
    • /
    • 2002
  • 컴포머는 산성화된 이중 기능성 레진 단량체와 fluoro-alumine-silicate 글라스 입자로 구성되어 초기에는 복합레진과 같이 광원에 의해 중합되며 이차적으로 구강내 수분을 흡수하면서 글라스 아이오노머 시멘트와 유사한 산-염기 반응으로 중합되고 이의 결과로 물성의 저하없이 지속적으로 불소를 유리한다고 보고되고 있으며, 물분자를 흡수하여 수화됨에 따라 서서히 팽창하여 광중합시의 수축을 보상하고 미세누출을 최소화할 수 있다고 보고되고 있으나 아직 확립되어 있지는 않은 상태이다. 이에 본 연구는 현재 소아치과 임상에서 많이 사용되고있는 컴포머를 대상으로 초기의 중합수축에 의한 미세누출이 수화 평창에 의해 감소되는지 여부를 복합레진과 비교하기 위하여 5급 와동의 교합면측과 치은면측의 미세누출양을 1일과 30일 후에 측정한 결과 30일 후 컴포머의 치은면측에서 현저히 낮은 미세누출을 보였다.

  • PDF

제 2 급 와동에 충전된 Compome의 미세누출에 관한 연구 (MICROLEAKAGE OF COMPOMER IN CLASS II CAVITY)

  • 임재훈;조용범
    • Restorative Dentistry and Endodontics
    • /
    • 제24권2호
    • /
    • pp.346-355
    • /
    • 1999
  • To evaluate the micro leakage of compomer, 4 materials were divided into 4 groups of 15 cavities each.(Group 1: Z-100, Group 2: Dyarct AP, Group 3: Fuji II LC, Group 4: Compoglass) After the class II cavities were prepared using carbide bur No. 553, all specimen were restored by incremental filling technique. In group 3, Z-100 was filled with a base of a light curing glass-ionomer. After 7 days, all specimens were thermocycled between $5^{\circ}C$ and $55^{\circ}C$ for 500 cycles, followed by placement in 50% silver nitrate dye for 2 hours at $37^{\circ}C$. After rinsed in distilled water, these teeth were immersed in photodeveloping solution and exposed to fluorescent light for 6 hours. Teeth were then washed in distilled water to remove the photodeveloping solution, sectioned mesio-distally and evaluated. The results were as follows : 1. In the cervical portion, there was significant difference between Fuji II LC and other groups(Z-100, Dyract AP, Compoglass), Fuji II LC had the least value.(p<0.05) 2. In the cervical portion, there was not significant difference among Dyract AP, Z-100 and Compoglass. 3. In the occlusal portion, there was not significant difference among Dyract AP, Z-100 and Compoglass. From the results above, In enamel, microleakage of compomer such as Dyract AP and Compoglass resemble to that of composite resin. It is thought that it is due to characteristics of composite resin portion of compomer. But in dentin, microleakage of compomer is higher than that of resin modified glass ionomer cement, it is thought that in compomer, acid-base reaction is not developed with dentin.

  • PDF

Micro-CT를 이용한 복합 레진 수복물 미세 누출도의 정량 분석 (Quantitative Micro-CT Evaluation of Microleakage in Composite Resin Restorations)

  • 이상익;현홍근;김영재;김정욱;이상훈;김종철;한세현;장기택
    • 대한소아치과학회지
    • /
    • 제34권2호
    • /
    • pp.222-233
    • /
    • 2007
  • 치과 수복 재료 검사 시 가장 중요하고 기본적인 것은 치아와 수복물 사이의 미세누출에 대한 평가이다. 미세 누출을 평가하는 방법은 여러 가지가 있지만 이들 대부분은 많은 단점들을 가지고 있다. 최근에 개발된 미세 단층촬영법(micro-CT)을 이용하면 시편을 비파괴적으로 처리하여 특정 밀도에 해당하는 부분의 3차원적 영상을 얻을 수 있으므로, 이를 이용하면 정확하고 정량적인 미세누출 평가도 가능할 것이다. 이 연구의 목적은 micro-CT를 사용하여, 레진 수복물의 미세 누출도를 정량적이고 비파괴적으로 측정할 수 있는 새로운 방법을 찾아내고, 이 새로운 방법을 기존의 색소 침투법과 비교해보는 것이다. 이를 위해, 위의 두 가지 방법을 사용하여 두 종류의 상아질 접착 시스템의 미세누출도가 평가되었다. 사람의 건전 소구치 40개를 임의로 20개씩 두 군으로 나누고 다음과 같이 처리하였다. Group 1 : $Adper^{TM}$ Singe Bond 사용 후 제 V급 와동 레진 수복, Gourp 2 : $Adper^{TM}\;Promp^{TM}$ L-pop 사용 후 제 V급 와동 레진 수복 모든 치아의 5급 와동은 $Filtek^{TM}$ Supreme으로 수복하였다. 그 후 각 군 중 10개의 치아는 micro-CT를 사용하여 미세 누출도를 평가하고, 나머지 10개는 기존의 색소 침투법으로 평가하였다. 이 연구의 결과는 다음과 같았다. 1. Micro-CT를 사용한 경우, 1군은 2군보다 통계적으로 유의성 있게 적은 양의 미세 누출을 보였다(p<0.01). 2. 기존의 색소 침투법을 사용한 경우에서 1군은 2군보다 적은 미세누출을 보였으며 이는 통계적으로 유의성이 있었다. (p<0.01). 3. 두 군간의 미세 누출도는 micro-CT를 사용한 방법에서 더 현저한 차이를 보였다. 4. 두 가지 방법 모두에서 법랑질 변연 부분보다 상아질 변연 부분에서 더 많은 미세 누출을 보였다.

  • PDF

상아질 지각과민 처치제의 적용 중에 일어나는 상아세관액 유동의 실시간 측정 (Real-time measurement of dentinal fluid flow during desensitizing agent application)

  • 김선영;김은주;이인복
    • Restorative Dentistry and Endodontics
    • /
    • 제35권5호
    • /
    • pp.313-320
    • /
    • 2010
  • 연구목적: 본 연구의 목적은 미세 유체 흐름 측정장치를 이용해서 각 상아질 지각과민 처치제의 적용 과정 중 발생하는 상아 세관액 흐름의 유동을 관찰하고, 상아질 지각과민 처치제 간 적용 후 투과도 감소의 차이를 비교하고자 하는 것이다. 연구 재료 및 방법: CEJ 5 mm 하방에서 절단한 소구치를 미세 흐름 측정장치에 연결하여 20 cm $H_2O$의 정수압을 가하였다. 치경부에 상하 3 mm, 근원심 4 mm, 깊이 2 mm의 V자 형태의 5급 와동을 형성하고 smear layer를 제거하기 위해 15초 동안 산 부식한 후 상아질 지각과민 처치제를 적용하였다. 사용된 상아질 지각과민 처치제는 Seal&Protect (SP), SuperSeal (SS), BisBlock (BB), Gluma desensitizer (GL), Bifluoride 12 (BF) 이다. 상아세관액의 흐름은 지각과민 처치제 도포 전부터 도포 후 5분까지 실시간으로 측정되었다. 결과: 실험에 사용한 모든 상아질 지각과민 처치제는 적용 후의 상아세관액 흐름율이 적용 전에 비해 유의하게 감소하였다(p < 0.05). SP는 GL과 BF에 비해 유의하게 투과도 감소가 나타났다 (p < 0.05). SS와 BB는 BF에 비해 유의하게 투과도 감소를 보였다 (p < 0.05). 결론: 지각과민 처치제의 도포 과정 동안 각 처치제의 특징적인 상아세관액의 유동을 미세 유체 흐름 측정장치를 통해 관찰 할 수 있었다.

접착제와 와동형성의 차이에 따른 5급 복합레진 수복의 전향적 임상연구 (PROSPECTIVE CLINICAL EVALUATION OF THREE DIFFERENT BONDING SYSTEMS IN CLASS V RESIN RESTORATIONS WITH OR WITHOUT MECHANICAL RETENTION)

  • 이경욱;정세준;한영철;손호현;엄정문;오명환;조병훈
    • Restorative Dentistry and Endodontics
    • /
    • 제31권4호
    • /
    • pp.300-311
    • /
    • 2006
  • 본 연구의 목적은 복합레진을 이용한 비우식성 치경부 5급 병소 수복에 있어서, 3가지 다른 접착제를, 유지구를 부여한 치아와 부여하지 않은 치아에 적용하였을 때의 임상적인 효능의 차이를 비교하기 위함이다. 총 150개의 치아를 각각 25개씩 6개의 군으로 나누었다. A군 : Scotchbond Multi-Purpose (SBMP, 3M ESPE, St. Paul, MN, USA, 4세대 접착제)를 사용하고 유지구를 부여하지 않음. B군 : SBMP 를 사용하고 유지구를 부여. C군 : BC Plus (Vericom Co., Anyang, Gyeonggido, Korea, 5 세대 접착제)를 사용하고 유지구를 부여하지 않음. D군 : BC Plus를 사용하고 유지구를 부여. E군 : Adper Prompt (3M ESPE, Seefeld, Germany, 6 세대 접착제)를 사용하고 유지구를 부여하지 않음. F군 : Adper Prompt를 사용하고 유지구를 부여. 모든 치아는 복합레진인 Denfil (Vericom Co., Anyang, Gyeonggido, Korea) 을 이용하여 충전하였다. 수복 직후와 수복 6 개월 후에 modified USPHS (United States Public Health Service) criteria에 따라 수복물을 임상적으로 평가하였다. 추가적으로 임상사진을 촬영하였으며, 에폭시 레진을 이용하여 복제한 후 주사전자현미경을 이용하여 이를 관찰하였다. 6개월 후 관찰 결과, alpha rating의 수가 각 실험군마다 동일하지는 않았지만, 통계적으로는 3가지의 접착제간에 유의할만한 차이는 없었고, 기계적인 유지구를 부여한 군과 부여하지 않은 군 간에도 유의할만한 차이는 없었다 (p < 0.05). 그러나 6개월의 관찰 기간은 일반적으로 기대되는 레진의 수명보다 짧기 때문에, 각 실험군 간의 차이를 알아보기 위해서는 추후 더 오랜 기간의 관찰이 요구 된다.

7세대 결합제의 미세누출에 관한 연구 (MICROLEAKAGE OF 7TH GENERATION BONDING SYSTEM)

  • 이상엽;김대업;라지영;이광희
    • 대한소아치과학회지
    • /
    • 제33권3호
    • /
    • pp.422-428
    • /
    • 2006
  • 상아질 접착제는 많은 발전을 거듭하여 적용 단계가 단순화되고 짧아져서 어린이에게 사용하기에 더욱 편리해졌다. 본 연구에서는 최근 개발된 7세대 결합제인 $i-bond^{TM}$(Kulzer, Germany)의 미세누출을 기존에 사용되는 다른 결합제와 비교하여 그 효용성을 평가하기 위함이다. 40개의 교정적 목적으로 발거된 건전한 소구치의 협면과 설면에 5급 와동을 형성하고 무작위로 4개의 군으로 나누었다. 1군은 4세대인 Scotchbond $Multi-Purpose^{(R)}$(3M, USA), 2군은 5세대 Clearfil SE Bond(Kuraray, Japan), 3군은 6세대 AQ Bond(Sun medical, Japan), 4군은 7세대 $i-bond^{TM}$(Kulzer, Germany)를 적용하고 복합레진 Z100(3M, USA)으로 충전하였다. 시편을 $5^{\circ}C$$55^{\circ}C$에 각 30초간 계류시켜 1,000회 열순환하고 2% methylene blue 용액에 24시간 넣어 염료를 침투시킨 뒤, 저속 diamond cutter($Isomet^{TM}$, Buehler, USA)를 이용하여 주수하에 치아를 협설로 절단하였다. 색소의 침투 정도를 입체현미경을 이용하여 침투깊이를 0에서 3점으로 채점하여 측정한 뒤 미세누출 정도를 비교하였다. 결과적으로 7세대 결합제의 미세누출 평균값이 다른 결합제보다 높게 나왔으며, 특히 4세대 결합제와는 통계적으로 유의한 차이가 있었다.

  • PDF

Ferric sulfate를 이용한 치수절단술 후 성견 치수의 조직반응에 관한 연구 (A HISTOPATHOLOGIC STUDY ON THE PULPAL RESPONSE IN DOGS AFTER PULPOTOMY WITH FERRIC SULFATE)

  • 이창섭;임철승;박주철;이상호
    • 대한소아치과학회지
    • /
    • 제27권2호
    • /
    • pp.333-343
    • /
    • 2000
  • 본 연구의 목적은 성견 치아에서 ferric sulfate로 치수절단술을 시행하고 상부 이장재의 영향을 최소화한 후에 잔존 치수 조직 반응을 formocresol을 사용한 군과 조직병리학적으로 비교 평가하는 것이다. 생후 $6\sim7$개월, 체중 $10\sim12Kg$ 정도의 성견 5마리의 전치 40개에 5급 와동을 형성하여 치수절단술을 시행하였다. 치수를 formocresol과 ferric sulfate를 이용하여 복조를 시행하고 IRM으로 밀봉하였다. 실험동물은 3일, 1주, 2주, 4주, 그리고 8주 후에 관류 고정하여 희생되었으며, 표본을 광학현미경으로 관찰하여 다음과 같은 결론을 얻었다. 1. Ferric sulfate군과 formocresol군 모두에서 치수절단술 후에 염증 반응을 보였지만 ferric sulfate군에서 현저히 감소된 염증 양상과 빠른 치수조직 회복소견을 보였다. 2. Ferric sulfate군에서 치수절단술 후 치수 측벽의 상아모세포의 배열 양상은 초기에는 치관부 1/3에 불규칙한 배열양상을 나타내었지만 2주 후부터는 대체로 회복된 양상을 보였다 그러나 formocresol군에서는 불규칙한 배열양상이 실험기간 동안 지속되었다. 3. 치근을 따라 넓고 길게 형성된 수복상아질층이 formocresol군 8주의 1개 치아에서 나타났으며 상아질교의 형성은 ferric sulfate군 8주의 2개 치아에서 관찰할 수 있었다.

  • PDF