• Title/Summary/Keyword: 4M analysis

Search Result 13,028, Processing Time 0.026 seconds

Structural Analysis of Multi-Functional Fishway in Seomoon Weir (서문보의 다기능 어도의 구조해석)

  • Lee, Young Jae;Lee, Jung Shin;Jang, Hyung Kyu
    • Ecology and Resilient Infrastructure
    • /
    • v.7 no.4
    • /
    • pp.308-319
    • /
    • 2020
  • In this study, the field applicability of the recently constructed multifunctional fishway in Seomunbo, Yeongcheon-si, and Gyeongsangbuk-do were examined. The analysis variables were R/C slab (S1) and R/C+S/C slab (S2), the underground passage standard areas (width × length) were 1.4 m × 0.2 m, 1.4 m × 0.3 m, and 1.4 m × 0.6 m, and the flow velocities were 0.8, 1.2, and 1.6 m/s. As a result of the analysis, the safety of the design of Seomunbo was evaluated. The analysis showed compared to the Seomoon Weir fishway, the maximum stress of S2 decreased by 24 - 32%, the bending moment of the underground passage decreased by 16 - 33%, the maximum stress of the sidewall decreased by 20 - 36%. In addition, the bending moment of the upper slab decreased by 17 - 33%, the maximum stress of the upper slab decreased by 9 - 28%, and the bending moment decreased by 19 - 33%. Complementation was required in the following percentages: 18% and 14% for the maximum stress and bending moment of the underground passage, respectively, 15% and 17% for the maximum sidewall stress and bending moment, respectively, and 11% and 16% for the upper slab maximum stress and bending moment, respectively. The results showed that S2 was superior to that of the Seomoon Weir fishway, and the underground passage size of 1.4 m × 0.3 m was superior to those of 1.4 m × 0.2 m and 1.4 m × 0.6 m, and R/C+S/C slab was superior to that of R/C slab. The findings are expected to be useful for constructing and designing the multifunctional fishway.

The Analysis of 1,4-Dioxane in Water Sample by Gas Chromatograph/Mass Spectrometer and Risk Assessment (기체크로마토그래프/질량분석계에 의한 물시료 중 1,4-dioxane의 분석 및 위해성 평가)

  • 홍지은;표희수;박송자
    • Environmental Analysis Health and Toxicology
    • /
    • v.18 no.3
    • /
    • pp.219-224
    • /
    • 2003
  • 1,4-Dioxane is used as a solvent for lacquers, paints, varnish removers, dye baths and printing compositions. And it is also used for detergent preparations, cosmetics, deodorants and fumigants. A method is described for the determination of 1,4-dioxane in water samples by GC/MS. The extraction recoveries were studied for some solvents and solvent volume ratio were investigated using r-butyl methyl ether (MTBE). Optimum condition was obtained by the liquid-liquid extraction using the 10 mL of MTBE for 10 mL of water. Method detection limit of 1,4-dioxane in the 20 mL of water samples was 0.05 ng/mL. It could be determined in the range of 0.24∼240 ng/mL in treated water, and in the range of 0.69∼81.9 ng/mL in raw water, respectively. Risk assessments with 1,4-dioxane exposure by drinking water ingestion were carried out. Based on the results of analysis, chronic daily intake of 1,4-dioxane was 2.22${\times}$10$\^$-4/ mg/kg/day and excess cancer risk was calcu-lated to be 2.44${\times}$10$\^$-6/.

Quantitative Analysis of trans-Resveratrol in Red Wines by Solid Phase Extraction and LC/MS (고체상 추출법과 LC/MS를 이용한 적포도주 중의 trans-Resveratrol 분석)

  • Park, Gyo-Beom;Moon, Hyoung-Sil;Lee, Sueg-Geun
    • Analytical Science and Technology
    • /
    • v.16 no.2
    • /
    • pp.125-133
    • /
    • 2003
  • In order to determine the contents of trans-resveratrol in red wine, which was mainly consumed in Korea, both LC/MS-ESI and LC/MS-APCI methods were used after solid-phase (Sep-Pak $C_{18}$-cartridges) extraction. The contents of trans-resveratrol obtained by LC/MS-ESI were detected in the range of $0.06-4.31{\mu}g/mL$. The recoveries were ranged from 88.4 to 97.9%. The values of relative standard deviation were ranged from 0.6 to 4.6% and the detection limit was $0.001{\mu}g/mL$. The contents of trans-resveratrol obtained by LC/MS-APCI were detected in the range of $0.09-4.02{\mu}g/mL$ and the detection limit was $0.005{\mu}g/mL$.

EEM Analysis of Open-Typed Cylindrical Shieldcase (양끝이 열린 실드케이스의 FEM해석)

  • Kim, Young-Hak
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.767-769
    • /
    • 2017
  • Four-shell open-typed shield case was analyzed using 3D FEM. Analysis Dimension was $2m{\times}2m{\times}2m$. Length of shield case was 0.6m and its diameter was 0.1m, 0.08., 0.06m and 0.04m. Thickness and permeablility of shield case was all 1mm and 50,000. The excited magneic fields were earth magneic fields, which were 24A/m in the holizontal direction and 36A/m in the vertical direction, respectively. During FEM analysis, shield case was located at the direction of holizontal magnetic field and was rotated $90^{\circ}$. Magnetic field was $4.45{\times}10^{-2}A/m$ at the direction of holizontal magnetic field and $6.66{\times}10^{-4}A/m$ at the $90^{\circ}$ rotated direction.

  • PDF

Antimicrobial activity of fermented Maillard reaction products, novel milk-derived material, made by whey protein and Lactobacillus rhamnosus and Lactobacillus gasseri on Clostridium perfringens

  • Kim, Yujin;Kim, Sejeong;Lee, Soomin;Ha, Jimyeong;Lee, Jeeyeon;Choi, Yukyung;Oh, Hyemin;Lee, Yewon;Oh, Nam-su;Yoon, Yohan;Lee, Heeyoung
    • Animal Bioscience
    • /
    • v.34 no.9
    • /
    • pp.1525-1531
    • /
    • 2021
  • Objective: The objective of this study was to evaluate the antimicrobial effects of fermented Maillard reaction products made by milk proteins (FMRPs) on Clostridium perfringens (C. perfringens), and to elucidate antimicrobial modes of FMRPs on the bacteria, using physiological and morphological analyses. Methods: Antimicrobial effects of FMRPs (whey protein plus galactose fermented by Lactobacillus rhamnosus [L. rhamnosus] 4B15 [Gal-4B15] or Lactobacillus gasseri 4M13 [Gal-4M13], and whey protein plus glucose fermented by L. rhamnosus 4B15 [Glc-4B15] or L. gasseri 4M13 [Glc-4M13]) on C. perfringens were tested by examining growth responses of the pathogen. Iron chelation activity analysis, propidium iodide uptake assay, and morphological analysis with field emission scanning electron microscope (FE-SEM) were conducted to elucidate the modes of antimicrobial activities of FMRPs. Results: When C. perfringens were exposed to the FMRPs, C. perfringens cell counts were decreased (p<0.05) by the all tested FMRPs; iron chelation activities by FMRPs, except for Glc-4M13. Propidium iodide uptake assay indicate that bacterial cellular damage increased in all FMRPs-treated C. perfringens, and it was observed by FE-SEM. Conclusion: These results indicate that the FMRPs can destroy C. perfringens by iron chelation and cell membrane damage. Thus, it could be used in dairy products, and controlling intestinal C. perfringens.

The Analysis of Anaerobic Power in Professional Female Basketball Players (여자 프로농구선수의 무산소성 파워 분석)

  • Chang Chung-Hoon;Nam Hyoung-Chun
    • The Journal of Korean Physical Therapy
    • /
    • v.14 no.2
    • /
    • pp.172-180
    • /
    • 2002
  • The purpose of this paper was to make an analysis of anaerobic power in professional female basketball players using the Wingate Test Method with bicycle ergometer. Twenty-three subjects(age $21.6\pm2.8years$, body height $178.0\pm7.4cm$, body weight $70.3\pm7.4kg$) were selected from professional female basketball team whose careers were over 10years and participated in this investigation. Each subject peformed a Wingate anaerobic power test to determine total work, peak power, mean power, fatigue index and blood lactate concentration. The following were obtained from result data analysis; 1. The Total Work of athletes was a $1128.7\pm120.6watt$ 2. The Peak Power of athletes was a $449.5\pm53.1watt$ 3. The Mean Power of athletes was a $369.1\pm39.4watt$ 4. The Fatigue Index of athletes was a $33.5\pm6.9\%$ 5. The blood lactate concentration was $1.85\pm0.85mM/L$ at the normal state and $3.16\pm1.53mM/L$ at the after Wingate test. The blood lactate concentration was $6.96\pm0.81mM/L$ after 3 minute and $6.95\pm1.05mM/L$ after 5 minutes.

  • PDF

Consequence Analysis of the Fire & Explosion on the Flammable Liquid Handling Facility and LPG Station (제 4류 위험물 취급소 및 LPG 충전소의 화재$\cdot$폭발 피해 영향분석)

  • Lee Su-Kyung;Lee Chang-Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.3 no.2 s.7
    • /
    • pp.77-84
    • /
    • 1999
  • The XX company that is handling the class IV hazardous materials, located in Bu-Chon City and the LPG station in front of the XX company which is about 20 meters apart, was chosen as the standard model for this study In carrying out the consequence analysis, PHAST and Super-Chems were used for the study and utilizing the output of the simulation, we have evaluated the consequences throughout the probit analysis and explosion overpressure analysis. In case of Acetone, the effect distance of the damage on facilities-that is the result of radiation heat flux of $37.5kW/m^2$ by TNO model-is 68.51m by PHAST model and 40.93m by Super-Chem model. The risk assessment of the LPG station which is based on the explosion resulted as the analysis of the fire ball showed the diameter 125.2m, the height 206.2m and the duration 11.28sec and the effect distance for the radiant heat flux $37.5kW/m^2$ was 137.0m.

  • PDF

A Study on the De-Icing Performance Evaluation and Design Guide for Ice Class Louver of the Vessels Operating in Cold Region (빙해선박 아이스 클래스 루버의 해빙(de-icing) 성능평가 및 설계기준에 관한 연구)

  • Jung, Young-Jun;Seo, Young-Kyo
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.52 no.4
    • /
    • pp.323-329
    • /
    • 2015
  • For the design guide of a vessel operating in cold region, numerical analysis was carried out to evaluate the ice class louver which installed the heating cables by using ANSYS 13.0 CFX. The numerical analysis was performed by considering Unsteady Reynolds Averaged Navier Stokes (RANS) equation. This study based on the experimental results of ‘The Cryogenic Performance Evaluation for the Excellent De-icing Ice Class Louver’ in KRISO. For validation of the numerical analysis results, the cold chamber experimental data measured by the heat sensors in certain location of the ice class louver was used. The external environmental temperature which varies from 0℃ to –30℃ was considered in numerical analysis. Also the design guide for optimum de-icing presented through heating cable power capacity(33 W/m, 45 W/m, 66 W/m), location of the heating cable(front, center, behind on the blade) and relative velocity(1 m/s, 4 m/s, 7 m/s).

HisCoM-GGI: Software for Hierarchical Structural Component Analysis of Gene-Gene Interactions

  • Choi, Sungkyoung;Lee, Sungyoung;Park, Taesung
    • Genomics & Informatics
    • /
    • v.16 no.4
    • /
    • pp.38.1-38.3
    • /
    • 2018
  • Gene-gene interaction (GGI) analysis is known to play an important role in explaining missing heritability. Many previous studies have already proposed software to analyze GGI, but most methods focus on a binary phenotype in a case-control design. In this study, we developed "Hierarchical structural CoMponent analysis of Gene-Gene Interactions" (HisCoM-GGI) software for GGI analysis with a continuous phenotype. The HisCoM-GGI method considers hierarchical structural relationships between genes and single nucleotide polymorphisms (SNPs), enabling both gene-level and SNP-level interaction analysis in a single model. Furthermore, this software accepts various types of genomic data and supports data management and multithreading to improve the efficiency of genome-wide association study data analysis. We expect that HisCoM-GGI software will provide advanced accessibility to researchers in genetic interaction studies and a more effective way to understand biological mechanisms of complex diseases.

Effects of Security Lighting Lamps on Discomfort Glare to Indoor Occupants

  • Lee, Yoon Jeong;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.15 no.4
    • /
    • pp.21-28
    • /
    • 2015
  • Purpose: Although security lights are used to secure pedestrian visibility and safety at nighttime, they can generate light trespass in the neighboring residential space. To prevent this, standards for acceptance limits on vertical illuminance and light pollution by the windows of residential buildings are presented. Method: This study thus representatively selected three types of lamps and, through an evaluation and analysis of the physical and subjective discomfort glare per lamp, proposed a discomfort glare index for each lamp. The evaluation and analysis according to the lamps were conducted through experiments. The variables were the security lights' lamps (NH 100W, MH 70W, LED 50W), installation angles ($0^{\circ}$, $20^{\circ}$), and installation distances (3m, 5m, 7m, 9m). Result: According to the results of the discomfort glare evaluation depending on the angles and distances of the security lights, the following minimum standards are proposed: for NH 100W, a discomfort glare index of 30 and an installation distance of 4m; for MH 70W, a discomfort glare index of 32 and an installation distance of 4m; and, for LED 50W, a discomfort glare index of 31 and an installation distance of 6m, respectively. In addition, this paper recommends the use of MH 70W, when the road width is 4m-6m, and LED 50W, when the road width is over 6m, respectively.