간외담도에 발생한 신경내분비암종 1예 (Large Cell Neuroendocrine Carcinoma of the Extrahepatic Bile Duct)

  • 박지영;전태주
    • 대한소화기학회지
    • /
    • 제72권6호
    • /
    • pp.318-321
    • /
    • 2018
  • Primary neuroendocrine tumors originating from the extrahepatic bile duct are rare. Among these tumors, large cell neuroendocrine carcinomas (NECs) are extremely rare. A 59-year-old man was admitted to Sanggye Paik Hospital with jaundice that started 10 days previously. He had a history of laparoscopic cholecystectomy, which he had undergone 12 years previously due to chronic calculous cholecystitis. Laboratory data showed abnormally elevated levels of total bilirubin 15.3 mg/dL (normal 0.2-1.2 mg/dL), AST 200 IU (normal 0-40 IU), ALT 390 IU (normal 0-40 IU), and gamma-glutamyl transferase 1,288 U/L (normal 0-60 U/L). Serum CEA was normal, but CA 19-9 was elevated 5,863 U/mL (normal 0-37 U/mL). Abdominal CT revealed a 4.5 cm sized mass involving the common bile duct and liver hilum and dilatation of both intrahepatic ducts. Percutaneous transhepatic drainage in the left hepatic duct was performed for preoperative biliary drainage. The patient underwent radical common bile duct and Roux-en-Y hepaticojejunostomy for histopathological diagnosis and surgical excision. On histopathological examination, the tumor exhibited large cell NEC (mitotic index >20/10 high-power field, Ki-67 index >20%, CD56 [+], synaptophysin [+], chromogranin [+]). Adjuvant concurrent chemotherapy and radiotherapy were started because the tumor had invaded the proximal resection margin. No recurrence was detected at 10 months by follow-up CT.

3D 프린터를 이용한 Customized Bolus 제작에 관한 연구 (A Study on Developing Customized Bolus using 3D Printers)

  • 정상민;양진호;이승현;김진욱;염두석
    • 대한방사선치료학회지
    • /
    • 제27권1호
    • /
    • pp.61-71
    • /
    • 2015
  • 목 적 : 3D 프린터는 입력한 도면을 바탕으로 3차원의 입체 모델을 만들어 낼 수 있는 장비이다. 이러한 특징을 이용하여 방사선치료시 bolus 사용으로 인한 피부와 bolus 사이의 air gap을 최소화 할 수 있는 bolus 제작이 가능하다. 이에 본 연구에서는 3D 프린터를 이용하여 customized bolus를 제작하여 air gap과 target 선량을 상품화된 1 cm bolus와 비교하고자 한다. 대상 및 방법 : 왼쪽 chest wall에 돌출된 종양이 있는 RANDO phantom을 CT 모의치료기를 이용하여 영상 획득 후, CT DICOM 파일을 3D 프린터에 필요한 STL 파일로 변환시켰다. 이것을 이용하여 치료부위의 체표윤곽과 일치하면서 1 cm 두께를 유지하는 customized bolus 주형틀을 3D 프린터로 제작한 후 paraffin wax를 녹여 customized bolus를 만들었다. 이렇게 만들어진 customized bolus와 상품화된 1 cm bolus의 air gap을 확인하였고, air gap으로 인한 차이를 Eclipse를 이용하여 치료계획상 $D_{max}$, $D_{min}$, $D_{mean}$, $D_{95%}$$V_{95%}$를 비교하였다. 결 과 : customized bolus 제작 기간은 약 3일이 소요되었다. air gap 총 용적은 customized bolus는 평균 $3.9cm^3$, 상품화된 1 cm bolus는 평균 $29.6cm^3$이었다. 상품화된 1 cm bolus를 사용할 때보다 3D 프린터를 이용하여 제작한 customized bolus를 사용하는 것이 air gap을 최소화시켰다. 6 MV photon에서 customized bolus의 $D_{max}$, $D_{min}$, $D_{mean}$, $D_{95%}$, $V_{95%}$는 각각 102.8%, 88.1%, 99.1%, 95.0%, 94.4%이었고, 상품화된 1 cm bolus의 $D_{max}$, $D_{min}$, $D_{mean}$, $D_{95%}$, $V_{95%}$는 101.4%, 92.0%, 98.2%, 95.2%, 95.7%이었다. proton의 경우 customized bolus의 $D_{max}$, $D_{min}$, $D_{mean}$, $D_{95%}$, $V_{95%}$는 각각 104.1%, 84.0%, 101.2%, 95.1%, 99.8%이었고, 상품화된 1 cm bolus의 $D_{max}$, $D_{min}$, $D_{mean}$, $D_{95%}$, $V_{95%}$는 104.8%, 87.9%, 101.5%, 94.9%, 99.9%이었다. 이처럼 치료계획에서 customized bolus와 1 cm bolus 모두 GTV의 선량은 큰 차이를 보이지 않았다. 그러나 GTV에 인접한 정상조직은 customized bolus의 선량이 더 적게 나타났다. 결 론 : 3D 프린터를 이용한 customized bolus가 표면이 일정하지 않은 치료부위에 사용 할 때 air gap을 줄이는 효과를 나타냈다. 그렇지만 상품화된 bolus와 피부 사이에 생기는 air gap은 target에서의 선량의 변화를 일으킬 만큼 많은 양이 아님을 알 수 있었다. 반면 chest wall에서는 air gap이 적을수록 선량이 감소함을 확인 할 수 있었다. customized bolus 제작 기간은 3일이 걸렸고, 고가의 제작비용이 든다는 문제점이 발생하였다. 따라서 3D 프린터 customized bolus의 상용화를 위해서는 저비용이고, bolus 사용으로 적합한 3D 프린터 재료 모색의 필요성이 있다고 사료된다.

  • PDF

폐암 SBRT에서 호흡동조 VMAT의 정확성 분석을 위한 새로운 4D 팬텀 모델 개발 (Development of New 4D Phantom Model in Respiratory Gated Volumetric Modulated Arc Therapy for Lung SBRT)

  • 윤경준;곽정원;조병철;송시열;이상욱;안승도;남상희
    • 한국의학물리학회지:의학물리
    • /
    • 제25권2호
    • /
    • pp.100-109
    • /
    • 2014
  • 정위신체방사선치료(SBRT)에서 환자의 호흡에 대한 정확한 치료위치의 확보는 필수적으로 고려되어야 하며 그 정확성에 관련하여 많은 연구들이 진행되어왔다. 본 연구에서는 실제 호흡에 의한 움직임과 실제 환자 폐의 형태를 고려한 팬텀실험으로 실제 치료에서 일어나는 임상적 상황을 모사함으로 호흡 동조 부피적조절회전 방사선치료(Volumeric Modulated Arc Therapy, VMAT) 기법을 이용한 폐부 SBRT의 정확성을 분석하는 방법을 제시하고자 하였다. SBRT을 받은 폐암 환자의 CT 영상을 기반으로 3D 프린터를 이용하여 치료부위와 유사하게 폐 팬텀을 제작하였고 환자 호흡과 동일하게 움직임을 재현할 수 있도록 $QUASAR^{TM}$ 호흡 동조 구동 팬텀(Modus Medical Devices, London, Canada)에 장착하여 호흡동조 VMAT에서의 2차원 선량 분포를 평가할 수 있는 시스템을 구축하였다. 폐 팬텀은 종양부위를 중심으로 2등분하여 EBT3 필름을 삽입하고 선량분포를 측정할 수 있도록 제작되었다. 비균질 조건에서의 선량계산의 정확성을 확인하기 위하여 균질한 플라스틱 팬텀과 제작된 비균질 폐 팬텀에서 Analytical Anisotropic Algorithm (AAA)와 AcurosXB (AXB) 두가지 알고리즘으로 선량계산을 하여 비교, 분석하였다. 움직임에 대한 치료의 정확성을 평가하기 위하여 호흡동조와 비 호흡동조의 경우, 그리고 움직임이 없는 조건에서 선량분포를 취득하여 치료계획 선량에 대한 감마지표를 분석하였다. 치료부위 GTV에서의 CT number는 실제 환자의 경우 78 HU를 나타내었고 모사된 폐 팬텀의 경우 92 HU를 나타내었다. 팬텀 내 폐 조직부분은 3D프린터로 적층하는 과정에서 격자구조의 형태를 이용하여 구현하였다. 측정된 필름선량은 AAA 알고리즘을 이용한 치료계획 선량에 대하여 움직이는 팬텀에서 호흡동조의 유무에 따라 3%/3 mm 감마지표 조건하에서 각각 88%와 78%의 감마합격률을 나타내었으며, 움직임이 없는 경우 95% 이상의 감마합격률을 보였다. AXB 알고리즘을 적용하였을 경우에는 모든 경우에서 98% 이상의 합격률을 나타내었다. 균질한 플라스틱 팬텀에 대하여 측정하였을 때 두가지 선량계산 알고리즘을 포함한 모든 조건에서 99% 이상의 감마합격률을 나타내었다. 선택된 환자의 호흡 진폭이 비교적 작고 inhale보다는 exhale에 더 오래 머무르는 호흡패턴 때문에 3%/3 mm 감마 기준에서는 호흡에 따른 차이가 거의 나타나지 않은 것으로 이해되었다. 선량계산의 정확성에서는 AAA 알고리즘을 적용하였을 때보다 AXB 알고리즘을 적용하였을 때가 균질과 비균질 환경에서의 선량 분포에 따른 감마 합격률의 차이가 적게 나타남을 확인 할 수 있었다. 본 논문에서는 환자와 유사하게 제작된 폐 팬텀에 실제 환자 호흡 패턴을 연동함으로 새로운 4D 치료선량 분포 검증 방법을 제시하였고 보다 사실적인 선량분포를 반영한 개별 환자 치료의 정확성 검증이 가능할 것으로 평가되었다.

6 MV 광자빔에 대한 MicroLion 액체이온함의 특성 연구 (A Study of Characteristics of MicroLion Liquid Ionization Chamber for 6 MV Photon Beam)

  • 최상현;허현도;김성훈;지영훈;김금배;김우철;김헌정;신동오;김찬형
    • 한국의학물리학회지:의학물리
    • /
    • 제22권4호
    • /
    • pp.216-223
    • /
    • 2011
  • 최근 PTW사에서는 물등가물질로 구성되어 있고, 측정체적(sensitive volume, $0.002cm^3$)이 매우 작은 MicroLion 액체이온함을 내놓았다. 본 연구의 목적은 외부방사선 치료용 광자빔에 대해 MicroLion 액체이온함의 선량선형성, 선량률의존성, 공간분해능, 그리고 출력인수와 같은 선량측정학적 특성을 조사하는 것이다. 이 결과를 Semiflex 이온함($0.125cm^3$), Pinpoint 이온함($0.015cm^3$), 다이오드 검출기($0.0025mm^3$)의 결과와 비교분석하여 소조사면 측정에 적절한지를 평가하고 자 하였다. Varian clinac 2300 C/D의 6 MV 광자빔에서 측정하였으며, MP3 물팬톰(PTW, Freiburg)을 이용하였다. 공간분해능은 반음영(penumbra)을 측정하여 평가하였으며, $0.5{\times}0.5cm^2$에서 $10{\times}10cm^2$까지 다양한 조사면에 대하여 측정하였다. 출력인수는 $0.5{\times}0.5cm^2$에서 $40{\times}40cm^2$에 대하여 측정하였다. 선량에 따른 MicroLion 액체이온함의 측정값은 선형적인 비례성을 보였다. 그러나 선량률은 100 MU/min와 600 MU/min에 의한 측정값의 차이가 최대 5%의 차이를 보였으며, 선량율이 커질수록 출력선량이 작아지는 결과를 보였다. 공간분해능의 경우 조사면 $0.5{\times}0.5cm^2$에서 $10{\times}10cm^2$까지의 측방선량분포 비교에서 Semiflex 이온함을 제외한 다른 모든 검출기들의 경우 2% 이내에서 일치하였다. 출력선량은 $2{\times}2cm^2$에서 $10{\times}10cm^2$ 조사면에서 Semiflex 검출기 대비 모든 검출기가 2% 이내에서 잘 일치하였다. 연구 결과 MicroLion 액체이온함은 물등가물질로 이루어져 있으며, 감응 면적이 매우 작기 때문에 소조사면에서 매우 유용할 것으로 사료된다.

3차원 체적팬텀을 이용한 토모치료의 Delivery Quality Assurance 평가 (Evaluation of DQA for Tomotherapy using 3D Volumetric Phantom)

  • 이상욱;김정구
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권4호
    • /
    • pp.607-614
    • /
    • 2016
  • 토모를 이용한 회전 방사선치료 시 2차원적인 선량분포 평가 대신 3차원적 선량분포 평가의 필요성에 관하여 연구하였다. 토모 치료 부위의 정확한 선량분포를 측정하기 위하여 RANDO phantom을 이용하였으며, 평가 대조군으로 gafchromic EBT2 필름의 선량분포와 3차원 체적팬텀인 ArcCHECK phantom을 이용하여 3차원적인 선량분포를 gamma correction(3%/3 mm, 2%/2 mm)으로 평가하였다. 팬텀에 대한 치료 영역은 각각 0.5, 1, 1.5, 2, 2.5, 3 cm로 설정하였으며, 처방선량을 1,200 cGy로 하여 5회씩 선량을 조사하였다. Gafchromic EBT2 필름을 이용한 절대선량 측정 시 평균오차는 $0.76{\pm}0.59%$이었으며, ArcCHECK phantom을 이용한 절대선량 측정 시 평균오차는 $1.37{\pm}0.76%$로 나타났다. 선량분포의 평가에서 gafchromic EBT2 필름인 경우 gamma correction(3%/3 mm)은 평균 $97.72{\pm}0.02%$, ArcCHECK phantom인 경우 평균 $99.26{\pm}0.01%$로 측정되었다. 또한 gafchro mic EBT2 필름에서 gamma correction(2%/2 mm)의 평균은 $94.21{\pm}0.02%$이며, ArcCHECK phantom에서는 평균은 $93.02{\pm}0.01%$로 측정되었다. 토모치료를 이용한 환자 DQA에서 3차원 체적팬텀인 ArcCHECK phantom을 이용한 선량분포 평가가 cheese phantom을 이용한 선량분포 평가에 비하여 치료영역 주변부에 대한 정확한 측정과 실시간 평가가 가능하므로 환자의 치료가 보다 더 정확하고 빨리 이루어질 수 있을 것으로 사료된다.

Neutron-shielding behaviour investigations of some clay-materials

  • Olukotun, S.F.;Mann, Kulwinder Singh;Gbenu, S.T.;Ibitoye, F.I.;Oladejo, O.F.;Joshi, Amit;Tekin, H.O.;Sayyed, M.I.;Fasasi, M.K.;Balogun, F.A.;Korkut, Turgay
    • Nuclear Engineering and Technology
    • /
    • 제51권5호
    • /
    • pp.1444-1450
    • /
    • 2019
  • The fast-neutron shielding behaviour (FNSB) of two clay-materials (Ball clay and Kaolin)of Southwestern Nigeria ($7.49^{\circ}N$, $4.55^{\circ}E$) have been investigated using effective removal cross section, ${\Sigma}_R(cm^{-1})$, mass removal cross section, ${\Sigma}_{R/{\rho}}(cm^2g^{-1})$ and Mean free path, ${\lambda}$ (cm). These parameters decide neutron shielding behaviour of any material. A computer program - WinNC-Toolkit has been used for computation of these parameters. The toolkit evaluates these parameters by using elemental compositions and densities of samples. The proficiency of WinNC-Toolkit code was probe by using MCNPX and GEANT4 to model fast neutron transmission of the samples under narrow beam geometry, intending to represent the actual experimental setup. Direct calculation of effective removal cross section ($cm^{-1}$) of the samples was also carried out. The results from each of the methods for each types of the studied clay-materials (Ball clay and Kaolin) shows similar trend. The trend might be the fingerprint of water content retained in each of the samples being baked at different temperature. The compositions of each sample have been obtained by Particle-Induced X-ray Emission (PIXE) technique (Tandem Pelletron Accelerator: 1.7 MV, Model 5SDH). The FNSB of the selected clay-materials have been compared with standard concrete. The cognizance of various factors such as availability, thermo-chemical stability and water retaining ability by the clay-samples can be analyzed for efficacy of the material for their FNSB.

호흡 운동에 의한 내부 장기의 움직임 감소에 관한 연구 (A Study on the Reduction of Organ Motion from Respiration)

  • 김재균;이동한;이동훈;김미숙;조철구;류성렬;양광모;오원용;지영훈
    • 한국의학물리학회지:의학물리
    • /
    • 제15권4호
    • /
    • pp.179-185
    • /
    • 2004
  • 선형 가속기를 통한 세기 변조절 방사선치료(Intensity Modulated Radiation Therapy, IMRT), IGRT, 3D-CRT (Three-Dimensional Conformal Radiotherapy) 및 사이버나이프를 통한 치료와 같은 3차원 방사선 치료에서 호흡에 의해 발생하는 종양의 움직임은 실제 치료에 있어 매우 중요한 요소이다. 이와 관련하여 움직이는 종양에 보다 정확한 방사선량을 조사시키기 위하여 ABC (Active Breathing Control), 호흡동기 방사선 치료 등의 여러 방법들이 사용되고 있다. 본 연구에서는 방사선 치료시 호흡에 따른 내부 장기의 움직임 감소 장치를 개발하여 내부 장기 중 횡격막 운동이 얼마나 효율적으로 감소하였는지에 대한 연구를 시행하였다. 4개의 벨트로 구성된 움직임 감소 장치를 환자에게 장착시키고, 환자의 복부 위에 작은 진공쿠션(Vaccum cusion)을 놓아 최대한 호흡을 내쉬게 한 후, 벨트로 환자의 횡격막 주위를 묶는 방법을 사용하였다 이때 횡격막에 움직임 감소 장치를 사용한 경우와 사용하지 않는 경우로 나누어 투시영상(fluoroscopy)에 나타난 횡격막의 움직임을 디지털 카메라 동영상 모드로 촬영하였다. 이 파일을 퍼스널 컴퓨터에 연결 후 포토샵 6.0 소프트웨어 프로그램을 통하여, 횡격막의 가장 높은 지점이 움직이는 최대점과 최소점을 관찰하여 횡격막 운동의 범위를 측정하였다. 움직임 감소장치를 사용하지 않은 경우 횡격막 움직임의 범위는 최소 1.14 cm에서 최대 3.14 cm였고, 그 평균값은 2.14 cm였다. 그러나 횡격막에 움직임 감소 장치를 사용한 결과 그 범위는 0.72~l.95 cm로, 평균값은 1.16 cm로 감소하였다. 횡격막 운동은 20~68.4% (평균 44.9%) 감소효과가 있었다. 횡격막 운동의 주기의 경우에는, 움직임 감소 장치를 사용한 결과 호흡 주기의 평균값이 4.4초에서 3.07초로 줄어들어 호흡이 빨라졌음을 확인할 수 있었다. 본 연구를 통하여 움직임 감소 장치를 사용함으로써 내부 장기 중 횡격막 움직임의 범위가 감소함과 동시에 CTV-PTV 마진이 크게 줄어드는 결과를 확인하였다. 이 결과를 통하여 흉부 또는 복부에 종양을 가진 환자 치료 시 더욱 질 높은 방사선 치료가 실현될 것으로 기대한다.

  • PDF

세기변조방사선치료 선량분포 확인을 위한 2차원적 이온전리함 배열의 특성분석 (Dosimetric Characterization of an Ion Chamber Matrix for Intensity Modulated Radiation Therapy Quality Assurance)

  • 이정우;홍세미;김연래;최경식;정진범;이두현;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제17권3호
    • /
    • pp.131-135
    • /
    • 2006
  • 본 연구의 목적은 2차원적 이온전리함 배열의 특성을 분석하고 세기변조방사선치료 선량분포 확인의 유용성을 평가하기 위함이다. 본 실험에 사용된 2차원적 이온전리함 배열(MatriXX, Scanditronix-Wellhofer, IBA, Germany)은 $24{\times}24cm^2$ 범위에 1,024개의 평판형 전리함(용적: $0.08cm^3$, 직경: 4.5 mm, 높이: 5 mm, 배열간격: 7.62 mm)이 일정한 간격으로 배열되어있다. MatriXX의 특성분석을 위해 선량 직선성, 선량률 의존도, 출력 계수, 단기 선릉재현성을 분석하였으며, 선량분포 확인의 신뢰도를 평가하기 위해 Varian사의 동적쐐기와 세기변조 방사선치료의 선량분포를 분석하였다. 선량 직선성의 범위는 $1{\sim}800$cGy이었으며, 1% 미만의 오차율을 보였다. 선량률 의존성(범위 $100{\sim}600MU/min$)은 300 Mu/min을 기준으로 했을 때 모든 선량률 범위에서 0.4% 미만의 선량변화를 보였다. 또한, 물팬톰에서 0.1 cc 지두형 전리함으로 측정한 출력계수와 폴리스틸렌 팬톰에서 MatriXX로 측정한 출력계수를 비교하였다. 이 실험의 결과, $3{\times}3{\sim}24{\times}24cm^2$ 범위에서 0.5% 미만의 일치를 나타내었다. 단기 출력재현성 확인을 위하여 15분 간격으로 6회 측정한 결과, 0.5% 내의 차이를 보였다. 동적쐐기와 세기변조 방사선 조사면의 일치성 실험에서도 치료계획장치의 계산값과 필름측정값이 비교적 잘 일치함을 알 수 있었다. 본 연구를 통해 MatriXX의 물리적인 특성을 분석하였으며 세기변조방사선치료의 품질관리를 위한 유용성을 확인하였다.

  • PDF

자궁경부암의 근치적 방사선치료 성적 (The Results of Curative Radiotherapy for the Uterine Cervical Cancer)

  • 김형진;김정수;김진기;권형철;오병찬
    • Radiation Oncology Journal
    • /
    • 제14권3호
    • /
    • pp.191-199
    • /
    • 1996
  • 목적 : 자궁경부암에서 근치적 방사선치료후 치료결과 및 예후에 영향을 미치는 인자와 치료후 합병증, 실패 양상을 알고자 후향적 연구를 시행하였다. 대상 및 방법 1986년 3월부터 1990년 5월까지 조직학적 검사로 확진되고 근치적 목적으로 외부조사 및 강내치료를 받은 59명의 환자를 대상으로 후향적 분석을 시행하였다. FIGO 병기에 따른 환자분포는 병기 IIa이하인 Ib, IIa가 각각 2예($3.4\%$), IIb가 31예($52.5\%$), IIIb가 15예 ($25.4\%$), IV가 9예($15.3\%$)였다. 외부조사를 시행한 후, 강내조사를 실시하였는 데, 강내치료는 A점을 기준으로 병기에 따라서 중앙값 3460 cGy(범위: 3000-4366 cGy)까지 조사하였으며, 강내 치료와 외부방사선 치료 전체조사량의 중앙값은 8500 cGy(범위: 8040-10980 cGy)였다. 추적조사 기간은 2개월에서 110개월이었고, 중앙값은 61개월이었다. 결과 : 전체환자의 5년생존율 및 무병생존율은 각각 $55.9\%$$55.0\%$였으며, FIGO 병기에 따른 5년 생존율은 병기 IIa이하인 경우 $75.0\%$, 병기 IIb는 $74.8\%$, 병기 IIIb는 $26.7\%$, 병기 IV는 $33.3\%$였다. 단변량 분석에 의하면 병기 IIb이하인 경우 5년 생존율은 $74.8\%$였고, IIIb이상인 경우 $29.2\%$ (p<0.005)였다 방사선치료중 혈색소 수준이 한 번이라도 10 gm/dL미만인 환자군의 5년 생존율은 $0\%$였고, 10 gm/dL이상 군은 $73.3\%$ (p<0.005)였다. 종양의 크기가 5 cm이상인 18예($30.5\%$)에서 5년 생존율은 $22.2\%$였고, 5cm미만인 39예($66.1\%$)에서는 $71.8\%$(p<0.005)였다. 또한 50세이상인 경우와 50세미만인 경우 5년 생존율은 각각 $65.3\%$, $34.2\%$ (p<0.05)였다. ECOG 수행능력 정도, 병리소견, 전체 선량, 전체 치료기간은 통계학적 의미는 없었다. 다변량분석에 의하면 방사선 치료중 혈색소 수준(p=0.0001), 종양의 크기(p=0.0390), FIGO병기 (p=0.0468)가 통계학적 의의를 나타냈다. 전체 환자의 재발율은 $23.7\%$(14/59)로 국소재발이 $15.2\%$(6/59), 원격전이가 $6.8\%$(4/59), 국소재발과 원격전이가 $1.7\%$(1/59)를 보였다. 결장직장과 비뇨생식기에서 각각 $15.3\%$(9/59), $8.5\%$(5/59)를 보이고, Grade 2는 10예($17.0\%$), Grade 3은 3예($5.1\%$), Grade 4도 1예($1.7\%$)를 나타내고 있다 빈도는 방사선 직장염, 직장 출혈, 방사선 대장염, 설사, 방사선 방광염 순서로 발생하였다. 결론 : 치료결과를 향상시키기 위해서는 전향적인 무작위 표본에 의한 새로운 예후인자 발견 및 예후가 좋지 않을 것으로 예상되는 경우, 치료방법의 개선 및 방사선 감작제 또는 항암제를 병용하여 국소재발과 원격전이 억제를 위한 적극적인 치료방법이 연구되어져야 한다고 사료된다.

  • PDF

유방암 환자의 수술 중 방사선치료 시 피부선량 측정을 통한 안전성 평가 (Evaluation of safety by skin dosimetry in Intraoperative Radiotherapy for breast cancer patients)

  • 정인호;김준원;박광우;하진숙;전미진;조윤진;김세준;김종대;신동봉
    • 대한방사선치료학회지
    • /
    • 제27권1호
    • /
    • pp.13-22
    • /
    • 2015
  • 목 적 : 유방암 환자를 대상으로 Intrabeam$^{TM}$ system을 이용한 수술 중 방사선치료(Intraoperative Radiotheray, IORT)를 국내에 처음 도입하는데 있어 광자극형광선량계(Optically Stimulated Luminescent Dosimeter, OSLD)를 이용한 피부선량측정을 통해 Intrabeam$^{TM}$ system의 안정성을 평가하고자 한다. 대상 및 방법 : 본원에서 2014년 8월부터 2015년 2월까지 유방보존술(breast-conserving surgery, BCS)후 Intrabeam$^{TM}$ system을 이용하여 수술 중 방사선치료(IORT)를 시행한 30명의 유방암 환자를 대상으로 진행하였다. 처방선량은 applicator 표면을 기준으로 20 Gy로 설정하여 1 cm 떨어진 지점에 약 5 Gy의 선량이 전달될 수 있도록 하였다. 종양 크기에 따라 applicator의 크기를 결정하였고 치료시간은 applicator의 크기에 따라 18~40분으로 설정되었다. 피부 절개면에서 Superior, Inferior, Lateral, Medial 4방향에 applicator를 중심으로부터 0.5 cm와 1.5 cm지점에 광자극형광선량계(OSLD)를 각각 부착하였다. 각 방향에 따라 U1,U2(Superior), D1,D2(Inferior), L1,L2(Lateral), M1,M2(Medial)로 총 8지점을 지정하였다. 각 지점에서의 측정값과 모든 지점의 평균값 및 최고값, 최저값을 산출하여 비교분석 하였다. 결 과 : Intrabeam$^{TM}$ system 50kVp X-ray source를 이용한 수술 중 방사선치료(IORT)시 OSLD의 측정 결과 U1 $2.23{\pm}0.80Gy$, U2 $1.54{\pm}0.53Gy$, D1 $1.73{\pm}0.63Gy$, D2 $1.25{\pm}0.45Gy$, L1 $1.95{\pm}0.82Gy$, L2 $1.38{\pm}0.42Gy$, M1 $2.03{\pm}0.70Gy$, M2 $1.51{\pm}0.58Gy$로 나타났으며 maximum값은 U1지점에서 4.34 Gy, minimum값은 M2지점에서 0.45 Gy로 나타났다. 전체 환자 중 13.3 %(N=4/30) 환자에서 4 Gy를 초과하는 측정값이 나타나 그 원인을 분석하였다. 결 론 : 본 연구를 통해 현재 본원에서 도입한 Intrabeam$^{TM}$ system을 이용한 수술 중 방사선치료(IORT)는 모든 환자의 피부선량값이 5 Gy미만으로 측정된 것으로 보아 그 안전성이 확인되었다. 피부선량이 4 Gy를 초과한 환자의 데이터 분석을 통해 breast volume이 상대적으로 작은 사이즈의 유방암환자의 경우 피부선량이 증가하는 경향을 보여 수술 중 방사선 치료 대상 환자 선정시 종양의 크기와 위치 뿐만 아닌 breast volume 값 등을 고려하여 피부에 전달되는 선량값이 기준값을 초과하지 않도록 주의 하여야 한다.

  • PDF