• 제목/요약/키워드: 4D CBCT

검색결과 73건 처리시간 0.028초

The prevalence and characteristics of external cervical resorption based on cone-beam computed tomographic imaging: a cross-sectional study

  • Matheus Diniz Ferreira;Matheus Barros-Costa;Felipe Ferreira Costa;Deborah Queiroz Freitas
    • Restorative Dentistry and Endodontics
    • /
    • 제47권4호
    • /
    • pp.39.1-39.12
    • /
    • 2022
  • Objectives: This study investigated the prevalence and characteristics of external cervical resorption (ECR) regarding sex, age, tooth, stages of progression, and portal of entry, using cone-beam computed tomography (CBCT) scans. Materials and Methods: CBCT scans of 1,313 patients from a Brazilian subpopulation comprising 883 female and 430 male patients (mean age, 55.2 years), acquired using a PreXion 3D CBCT unit, were evaluated. All permanent teeth included in the scans were evaluated for the presence of ECR according to the 3-dimensional classification and the portal of entry. The association between the presence of ECR and the factors studied was assessed using the χ2 test. Intra-observer agreement was analyzed with the kappa test (α = 0.05). Results: In total, 6,240 teeth were analyzed, of which 84 (1.35%) were affected by ECR. A significant association was found between the presence of ECR and sex, with a higher prevalence in male patients (p = 0.002). The most frequently affected teeth were the mandibular and maxillary central incisors. The most common height was the mid-third of the root. For the portal of entry, 44% of cases were on the proximal surfaces, 40.5% on the lingual/palatal surface and 15.5% on the buccal surface. Intra-observer agreement was excellent. Conclusions: The prevalence of ECR was 1.35%, with a higher prevalence in male patients and a wide age distribution. The mandibular and maxillary central incisors were the most commonly affected teeth, and cases of ECR most frequently showed a height into the mid-third of the root and proximal entry.

금속 3D printing으로 제작한 치과보철물의 표면특성 (Surface Characteristics of Metallic 3D Printed Dental Framework)

  • Choe, Han-Cheol
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2018년도 춘계학술대회 논문집
    • /
    • pp.21-21
    • /
    • 2018
  • 다양한 소재(금속, 세라믹, 고분자 소재 등)들이 3차원 형상기반 적층제조법에 적용되고 있는데, 금속 소재를 이용하여 3D 프린팅 법으로 치과용 수복물을 제조하는 연구가 많이 보고되고 있다. 하지만, 티타늄 또는 티타늄 합금 분말을 이용하여 3D 프린팅 법으로 제작한 치과용 보철물에 관한연구 보고는 많지 않다. Kanazawa 등 (2014)은 Ti-6Al-4V 합금분말을 이용하여 SLM법으로 총의치 용 framework를 제작하여 주조법으로 제작한 것과 비교 평가하였고, Mangano 등(2013)은 Ti-6Al-4V 합금분말로 지름이 작은 일체형 (1-piece narrow-diameter) 임플란트를 SLS법으로 제작하여 16명의 환자에게 식립한 다음, 2년간 관찰하였고, Mangano 등 (2014)은 cone-beam computed tomography (CBCT) data를 3D이미지로 변환시켜 DLMS법으로 치근 형상의 임플란트를 제작하여 15명의 환자에게 식립한 다음, 1년간 관찰하였다. 또한 서울대학교 및 연세대학교 치과생체재료과학교실 (2016)에서는 3D 프린팅 법으로 제작한 티타늄 시편과 기계 가공한 티타늄 시편의 물성을 비교하였다. 그러나 티타늄 합금 분말을 이용하여 3D 프린팅 법으로 제작한 치과용 보철물을 실제 임상에 적용하는 단계에서 기존 기계가공 방식으로 제작한 티타늄 보철물과 3D 프린팅 법으로 제작한 티타늄 보철물의 물성과 표면특성을 다양하게 비교 평가하는 것이 필요하여 본 연구에서는 3D 프린팅 법으로 제작한 티타늄 시편과 기계 가공한 티타늄 시편의 물성특성과 표면특성을 비교하여 조사하였다.

  • PDF

CBCT 및 3D CT를 활용한 상악 유구치 치근과 근관 형태 (Root and Canal Morphology of Maxillary Primary Molar using CBCT and 3D CT)

  • 김준희;김현태;신터전;현홍근;김영재;김정욱;장기택;송지수
    • 대한소아치과학회지
    • /
    • 제48권4호
    • /
    • pp.437-448
    • /
    • 2021
  • 이 연구의 목적은 상악 유구치의 치근 및 근관의 형태학적 특성을 분석하는 것이다. 2006년 1월부터 2020년 4월까지 서울대학교 치과병원에서 CBCT 및 3D CT를 촬영한 3 - 7세 환자 총 268명(남자 175명, 여자 93명)이 연구에 포함되었으며, 치근 흡수와 치수병변이 없는 총 1002개의 상악 유구치의 치근과 근관 수를 분석하였다. 218개의 치아에 대해 치근과 근관의 형태, 이개각도, 치근과 근관의 길이 및 근관의 단면 형태를 분석하였다. 48개의 치아에 대해서는 Mimics 및 3-Matics software를 사용하여 치근 치수의 부피와 표면적, 치근-치수 비를 측정하였다. 절반 이상이 3개의 치근과 3개의 근관을 가지고 있었다. 좌우측 치아의 대칭성(Cohen's kappa coefficient)은 약 0.63이었다. 치근과 근관의 형태는 상악 제1유구치에서는 직선형이, 제2유구치에서는 곡선형이 많이 관찰되었다. 치근의 이개 정도, 치근과 근관의 길이는 상악 제1, 2유구치 모두 구개측 치근에서 가장 크게 나타났다. 근단부에서 근관의 단면 형태는 주로 ovoid 혹은 round형이었다. 치근 치수의 부피와 표면적, 치근-치수 비는 상악 제1,2유구치 모두 구개측 치근 치수에서 가장 크게 나타났다.

Comparison of postoperative changes in the distal and proximal segments between conventional and sliding mini-plate fixation following mandibular setback

  • Kim, Seong-Sik;Kwak, Kyoung-Ho;Ko, Ching-Chang;Park, Soo-Byung;Son, Woo-Sung;Kim, Yong-Il
    • 대한치과교정학회지
    • /
    • 제46권6호
    • /
    • pp.372-378
    • /
    • 2016
  • Objective: The purpose of the present study was to evaluate the postoperative three-dimensional (3D) changes in the proximal segments after mandibular setback sagittal split ramus osteotomy and to compare the changes between the conventional mini-plate fixation and semi-rigid sliding plate fixation. Methods: Cone-beam computed tomography (CBCT) images were used to evaluate the postoperative 3D changes in the proximal segments during the healing process. CBCT images were superimposed using the symphysis and the lower anterior mandible as references. Results: There were no statistically significant differences between the conventional mini-plate and semi-rigid sliding plate groups (p > 0.05). With respect to the distribution of changes greater than 2 mm in the landmarks, the right condylion, right coronoid process, and left condylion showed ratios of 55.6%, 50.0%, and 44.4%, respectively, in the semi-rigid sliding plate group; however, none of the landmarks showed ratios greater than 30% in the conventional mini-plate group. Conclusions: There were no statistically significant differences in postoperative changes in the segments between the conventional mini-plate and semi-rigid sliding plate groups. Nevertheless, while selecting the type of fixation technique, clinicians should consider that landmarks with greater than 2 mm changes were higher in the semi-rigid sliding plate group than in the conventional mini-plate group.

MC 시뮬레이션을 이용한 Aft-Multiple-Silt 시스템의 산란선 제거 효과 평가 (Evaluation of Scatter Reduction Effect of the Aft-Multiple-Slit (AMS) System Using MC Simulation)

  • 장지나;서태석;장도윤;장홍석;김시용
    • Radiation Oncology Journal
    • /
    • 제28권4호
    • /
    • pp.224-230
    • /
    • 2010
  • 목적: 본 연구에서는 콘빔 CT에서 산란선 제거를 위한 aft-multple-slit (AMS) 시스템을 설계하였다. 예비 연구로서 본 시스템의 효용성을 검증하기 위해 MC 시뮬레이션을 수행하였다. 대상 및 방법: 가상 시뮬레이션은 산란선과 산란선+일차선을 계산할 수 있는 MCNPX의 radiography tally 5를 이용하였다. AMS는 빔의 발산성을 고려한 각이 동일한 아크 형태이고, 길이 방향에서의 산란선을 막는다. AMS의 효용성을 위한 평가는 AMS를 사용하지 않았을 때의 일차선과 산란선을 비교함으로써 수행되었다. 2D projection 영상을 얻기 위해 전체의 AMS는 한번의 캔트리 회전 후 AMS에 의해 가려진 부분의 영상 획득을 위해 다시 한 번 회전하는 구조이다. 결과: 일차선의 2D projection 영상은 모든 AMS의 폭에서 그리고 AMS를 사용하지 않았을 때에도 동일하였으나 일차선+산란선의 2D projection 영상은 slit의 폭에 따라 결과가 변했다. Slit의 폭을 5 mm, 10 mm, 15 mm, 20 mm로 하였을 때 평균 산란성 제거율은 29%, 15%, 9%, 8%였다. 결론: 본 연구에서는 AMS를 이용한 콘빔 CT의 산란선 제거 효과를 평가하였다. MC 시뮬레이션을 이용한 본 시스템의 사전 연구에서는 상당한 산란선 제거 효과를 보여주었다.

The effects of different metal posts, cements, and exposure parameters on cone-beam computed tomography artifacts

  • Ana Priscila Lira de Farias Freitas;Larissa Rangel Peixoto;Fernanda Clotilde Mariz Suassuna;Patricia Meira Bento;Ana Marly Araujo Maia Amorim;Karla Rovaris Silva;Renata Quirino de Almeida Barros;Andrea dos Anjos Pontual de Andrade Lima;Daniela Pita de Melo
    • Imaging Science in Dentistry
    • /
    • 제53권2호
    • /
    • pp.127-135
    • /
    • 2023
  • Purpose: This study assessed the intensity of artifacts produced by 2 metal posts, 2 cements, and different exposure parameters using 2 cone-beam computed tomography (CBCT) units. Materials and Methods: The sample was composed of 20 single-rooted premolars, divided into 4 groups: Ni-Cr/zinc phosphate, Ni-Cr/resin cement, Ag-Pd/zinc phosphate, and Ag-Pd/resin cement. Samples were scanned before and after post insertion and cementation using a CS9000 3D scanner with 4 exposure parameters (85/90 kV and 6.3/10 mA) and an i-CAT scanner with 120 kV and 5 mA. The presence of artifacts was assessed subjectively by 2 observers and objectively by a trained observer using ImageJ software. The Mann-Whitney, Wilcoxon, weighted kappa, and chi-square tests were used to assess data at a 95% confidence level(α<0.05). Results: In the subjective analyses, AgPd presented more hypodense and hyperdense lines than NiCr (P<0.05), and more hypodense halos were found using i-CAT (P<0.05) than using CS9000 3D. More hypodense halos, hypodense lines, and hyperdense lines were observed at 10 mA than at 6.3 mA (P<0.05). More hypodense halos were observed at 85 kV than at 90 kV (P<0.05). CS9000 3D presented more hypodense and hyperdense lines than i-CAT (P<0.05). In the objective analyses, AgPd presented higher percentages of hyperdense and hypodense artifacts than NiCr (P<0.05). Zinc phosphate cement presented higher hyperdense artifact percentages on CS9000 3D scans(P<0.05). CS9000 3D presented higher artifact percentages than i-CAT(P<0.05). Conclusion: High-atomic-number alloys, higher tube current, and lower tube voltage may increase the artifacts present in CBCT images.

Influence of voxel size on cone-beam computed tomography-based detection of vertical root fractures in the presence of intracanal metallic posts

  • Yamamoto-Silva, Fernanda Paula;de Oliveira Siqueira, Claudeir Felipe;Silva, Maria Alves Garcia Santos;Fonseca, Rodrigo Borges;Santos, Ananda Amaral;Estrela, Carlos;de Freitas Silva, Brunno Santos
    • Imaging Science in Dentistry
    • /
    • 제48권3호
    • /
    • pp.177-184
    • /
    • 2018
  • Purpose: This study was performed to evaluate the influence of voxel size and the accuracy of 2 cone-beam computed tomography (CBCT) systems in the detection of vertical root fracture (VRF) in the presence of intracanal metallic posts. Materials and Methods: Thirty uniradicular extracted human teeth were selected and randomly divided into 2 groups(VRF group, n=15; and control group, n=15). The VRFs were induced by an Instron machine, and metallic posts were placed in both groups. The scans were acquired by CBCT with 4 different voxel sizes: 0.1 mm and 0.16 mm (for the Eagle 3D V-Beam system) and 0.125 mm and 0.2 mm (for the i-CAT system) (protocols 1, 2, 3, and 4, respectively). Interobserver and intraobserver agreement was assessed using the Cohen kappa test. Sensitivity and specificity were evaluated and receiver operating characteristic analysis was performed. Results: The intraobserver coefficients indicated good (0.71) to very good (0.83) agreement, and the interobserver coefficients indicated moderate (0.57) to very good (0.80) agreement. In respect to the relationship between sensitivity and specificity, a statistically significant difference was found between protocols 1 (positive predictive value: 0.710, negative predictive value: 0.724) and 3 (positive predictive value: 0.727, negative predictive value: 0.632) (P<.05). The least interference due to artifact formation was observed using protocol 2. Conclusion: Protocols with a smaller voxel size and field of view seemed to favor the detection of VRF in teeth with intracanal metallic posts.

방사선치료 시 자세확인시스템이 처방선량에 미치는 영향 (The Effect of Patients Positioning System on the Prescription Dose in Radiation Therapy)

  • 김정호;배석환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권4호
    • /
    • pp.613-620
    • /
    • 2017
  • 방사선치료 시 치료계획 선량의 정확한 전달이 중요하다. 뿐만 아니라 정확한 자세 잡이도 필요하다. 하지만 정확한 자세 잡이를 위해서는 자세촬영을 실시하여야 하며 이에 따른 추가적인 방사선 피폭이 발생하게 된다. 이에 자세촬영 주기에 따른 선량분포의 변화를 분석하고자 한다. 팬텀 내 45개 지점에 대해 OSLD를 이용하여 6MV와 10MV 광자선, 그리고 온보드이미지촬영과 콘빔전산화단층촬영에 대한 선량을 측정하였다. 그리고 각 지점에 대한 자세확인촬영이 치료선량에 합산될 경우의 차이값을 비교하였다. 또한 차이값이 미국의학물리협회에서 권고하는 5%를 만족하는 촬영 주기를 제시하고자 하였다. 그 결과 6MV에서는 최소 45.27 cGy에서 최대 98.6 cGy, 10MV에서는 최소 53.34 cGy에서 최대 99.66 cGy, 온보드이미지촬영의 경우 최소 0.19 cGy에서 최대 2.64 cGy, 콘빔전산화단층촬영의 경우 최소 0.54 cGy에서 최대 17.18 cGy가 측정되었다. 치료선량에 대한 자세확인촬영 방사선량의 비율은 2차원 영상의 경우 치료 1회당 최대 3.49%, 3차원 영상의 경우 치료 1회당 최대 22.65%의 오차가 발생된다. 따라서 2차원 영상은 1일 1회, 3차원 영상은 1주 1회까지 허용된다. 향후 추가연구 시 실제 임상적용 시에는 환자자세촬영 종류의 병행에 대한 분리계산이 필요하리라 사료된다.

New three-dimensional cephalometric analyses among adults with a skeletal Class I pattern and normal occlusion

  • Bayome, Mohamed;Park, Jae Hyun;Kook, Yoon-Ah
    • 대한치과교정학회지
    • /
    • 제43권2호
    • /
    • pp.62-73
    • /
    • 2013
  • Objective: The purpose of this study was to assess new three-dimensional (3D) cephalometric variables, and to evaluate the relationships among skeletal and dentoalveolar variables through 3D cephalometric analysis. Methods: Cone-beam computed tomography (CBCT) scans were acquired from 38 young adults (18 men and 20 women; $22.6{\pm}3.2$ years) with normal occlusion. Thirty-five landmarks were digitized on the 3D-rendered views. Several measurements were obtained for selected landmarks. Correlations among different variables were calculated by means of Pearson's correlation coefficient values. Results: The body of the mandible had a longer curve length in men ($102.3{\pm}4.4$ mm) than in women ($94.5{\pm}4.7$ mm) (p < 0.001), but there was no significant difference in the maxillary basal curve length. Men had significantly larger facial dimensions, whereas women had a larger gonial angle ($117.0{\pm}4.0$ vs. $113.8{\pm}3.3$; p < 0.001). Strong-to-moderate correlation values were found among the vertical and transverse variables (r = 0.71 to 0.51). Conclusions: The normative values of new 3D cephalometric parameters, including the maxillary and mandibular curve length, were obtained. Strong-to-moderate correlation values were found among several vertical and transverse variables through 3D cephalometric analysis. This method of cephalometric analyses can be useful in diagnosis and treatment planning for patients with dentofacial deformities.

Cone beam CT를 이용한 비글견 발치창 치유과정에 대한 방사선학적 연구 (Radiologic study of the healing process of the extracted socket of beagle dogs using cone beam CT)

  • 최동훈;이완;김대석;이병도
    • Imaging Science in Dentistry
    • /
    • 제39권1호
    • /
    • pp.19-25
    • /
    • 2009
  • Purpose: To longitudinally observe the healing process of extracted socket and the alterations of the residual ridge in healthy adult dogs using cone beam CT (CBCT). Materials and Methods: The mandibular premolars of two beagle dogs were removed and the extraction sites were covered with the gingival tissue. CBCTs (3D X-ray CT scanner, Alphard vega, Asahi Co.) were taken at baseline and at 1 week interval for 12 weeks. Radiographic density of extracted wounds was measured on normalized images with a custom-made image analysis program. The amount of alveolar crestal resorption after the teeth extraction was measured with a reformatted three-dimensional image using CBCT. Bony healing pattern of extracted wound of each group was also longitudinally observed and analyzed. Results: Dimensional changes occurred during the first 6 weeks following the extraction of dogs' mandibular premolars. The reduction of the height of residual ridge was more pronounced at the buccal than at the lingual aspect of the extraction socket. Radiographic density of extracted wounds increased by week 4, but the change in density stabilized after week 6. New bone formation was observed at the floor and the peripheral side of extracted socket from week 1. The entrance of extracted socket was sealed by a hard-tissue bridge at week 5. Conclusion: The healing process of extracted wound involved a series of events including new bone formation and residual ridge resorption.

  • PDF