• Title/Summary/Keyword: 4-terminal measurements

Search Result 30, Processing Time 0.021 seconds

4-Terminal Measurement Technique of 2-Terminal Decade Resistor (2단자 계단식 저항기의 4단자 측정기술)

  • Lee, Sang-Hwa;Jang, Seok-Myeong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.12
    • /
    • pp.1798-1802
    • /
    • 2013
  • We present a technique for measuring low resistance ranges of a decade resistor with a 4-Terminal connection. With the technique the accuracy of 0.8 % was obtained for a 1 $m{\Omega}$ resistance of the decade resistor. We suggested a proper pattern 4-Terminal measurement results with several 4-Terminal pattern and adapters. Additionally, we should that precise measurements for low resistance can be made usung a digital multimeter(DMM) only.

The Utility of Contrast Enhanced Ultrasound and Elastography in the Early Detection of Fibro-Stenotic Ileal Strictures in Children with Crohn's Disease

  • Sarah D. Sidhu ;Shelly Joseph;Emily Dunn;Carmen Cuffari
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.26 no.4
    • /
    • pp.193-200
    • /
    • 2023
  • Purpose: Crohn's disease (CD) is a chronic, idiopathic bowel disorder that can progress to partial or complete bowel obstruction. At present, there are no reliable diagnostic tests that can readily distinguish between acute inflammatory, purely fibrotic and mixed inflammatory and fibrotic. Our aim is to study the utility of contrast enhanced ultrasound (CEUS) in combination with shear wave elastography (SWE) to differentiate fibrotic from inflammatory strictures in children with obstructive CD of the terminal ileum. Methods: Twenty-five (19 male) children between 2016-2021 with CD of the terminal ileum were recruited into the study. Among these patients, 22 had CEUS kinetic measurements of tissue perfusion, including wash-in slope (dB/sec), peak intensity (dB), time to peak intensity (sec), area under the curve (AUC) (dB sec), and SWE. In total, 11 patients required surgery due to bowel obstruction. Histopathologic analysis was performed by a pathologist who was blinded to the CEUS and SWE test results. Results: Patients that underwent surgical resection had significantly higher mean area under the curve on CEUS compared to patients responsive to medical therapy (p=0.03). The AUC also correlated with the degree of hypertrophy and the percent fibrosis of the muscularis propria, as determined by histopathologic grading (p<0.01). There was no difference in the mean elastography measurements between these two patient groups. Conclusion: CEUS is a useful radiological technique that can help identify pediatric patients with medically refractory obstructive fibrotic strictures of the terminal ileum that should be considered for early surgical resection.

Analysis of On-Line Partial Discharge Patterns in High Voltage Motor Stator Windings (고압전동기 고정자 권선의 운전중 부분방전 패턴 분석)

  • Kim, Hee-Dong;Ju, Young-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1824-1827
    • /
    • 2003
  • During normal machine operation, partial discharge(PD) measurements were performed with turbine generator analyzer(TGA) in two high voltage motors. Two 6.6kV motors were installed with 80pF capacitive couplers at the terminal box. The PD patterns were displayed two dimensional and three dimensional. TGA summarizes each plot with two quantifies such as the normalized quantity number(NQN) and the peak PD magnitude(Qm). Off-line PD measurements were conducted on one 4.16kV motor. The motor was energized to 2.4kV, 3.0kV, 3.5kV and 4.16kV, respectively. The PD levels in pC were measured with a conventional digital PD detector. The comparison of positive to negative PD indicates whether the defect elements of PD are within the insulation or on the insulation surface. Discharge at conductor surface was discovered in No. 1 motor. Internal discharges were generated in phase A, B and C of No. 2 motor, Slot discharges occurred in three phases of No. 3 motor.

  • PDF

Luminosities and Rates of Mass Loss of Some Galactic Wolf-Rayet Stars (은하 볼프-레이에 별의 광도와 질량손실률)

  • Woo, Jong-Ok
    • Publications of The Korean Astronomical Society
    • /
    • v.4 no.1
    • /
    • pp.16-30
    • /
    • 1989
  • We present recent data of absolute measurements of flux emmitted in the visible continua of some galactic Wolf-Rayet stars, carried out by means of a two-channel scanner built up cooperatively by the Observatoire de Lyon and the Laboratoire d'Astronomie Spatiale. Our measurements lead to the determination of stellar angular diameters which enable us to compute log $L_*/L_{\odot}$ and to locate the WR stars in the HR diagram: The WR stars are cooler than the zero age main sequence (ZAMS) and the WN7, WN8 types appear more luminous than other subclasses. The stellar wind terminal velocities, $V_{\infty}$, deduced from the empirical relation of the effective temperatures by Underhil1(1983) and $V_{\infty}$ adopted from the work of Willis(1982) show about 2,000km/s. We derived the rate of mass loss for the program stars from the formula, $\dot{M}={\varepsilon}(T_{eff})\;L/V_{\infty}{\cdot}c$ by using the obtained effective temperatures, luminosities and $V_{\infty}$ in this work. Their values range from $\dot{M}=1.4{\times}10^{-5}$ to $\dot{M}=5.8{\times}10^{-5}\;\dot{M}_{\odot}/yr$.

  • PDF

Partial Discharge Measurements of High Voltage Rotating Machine Stator Windings (고압회전기 고정자 권선의 부분방전 측정)

  • Kim, Hee-Dong;Lee, Young-Jun;Kong, Tae-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1828-1830
    • /
    • 2003
  • Partial discharge(PD) tests are used to evaluate the insulation condition of stator windings in two 4.16kV and three 6.6kV motors. These tests were conducted using a conventional partial discharge detector(PDD) and turbine generator analyzer(TGA). Off-line PD measurements were performed on five high voltage motors. PD magnitudes ranged from 1000 pC to 5400 pC at the normal line-to-ground voltage. Five high voltage motors have been equipped with 80pF epoxy-mica coupler on the motor terminal box. The PD pulse from sensors were measured with the TGA instrument. TGA summarizes each plot with two Quantities such as the peak PD magnitude(Qm) and the total PD activity(NQN). The defect mechanisms of high voltage motor can be associated with PD patterns such as internal, slot and conductor surface discharges. The PDD and TGA test results of No. 4 motor showed that internal discharge was detected in voids of the groundwall insulation.

  • PDF

Development and Evaluation of 3-terminal Type Capacitive Sensor for the Diagnosis of Electrical Insulating Oil (전기 절연유 열화진단을 위한 3-단자식 전기용량 센서 개발 및 진단특성 평가)

  • Kim, Ju-Han;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.476-482
    • /
    • 2009
  • This paper describes the development of capacitive sensor for the diagnosis of liquid dielectrics, which is widely used as the electrical insulating oil of transformer, circuit breaker, cable and etc. To survey the dielectric properties of the virgin and aged electrical insulating oils, we utilized the highly precise measuring system, using the principle of cross capacitance. The measured properties were used to determine the design factors of the sensor. Then the factors were optimized with the help of computational analysis. To evaluate diagnosis by the sensor, we performed accelerated thermal aging test about electrical insulating oils. The condition of aged specimens were investigated by measurements of relative permittivity i.e. capacitance change by capacitive sensor. And to evaluate the hysteresis characteristics with the change of temperature, we constructed a testing system, which was composed with vacuum drying oven, oil chamber and measuring instruments, such as LCR meter, MUX and so forth. Through the results of this investigation, we confirmed the superior characteristics of the newly developed sensor.

Feature Extraction for Fault Signals of High Voltage Motor Stator Windings (고압전동기 결함신호의 특징추출에 관한 연구)

  • Park, Jae-Jun;Kim, Hee-Dong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1154-1157
    • /
    • 2004
  • During normal machine operation, partial discharge(PD) measurements were performed with turbine generator analyzer(TGA) in imitation stator winding of high voltage motors. The motor was energized to 4.47kV, 6.67, respectively. Applied voltage to Imitation winding was used two voltage level, 4.47[KV]and 6.67[KV]. Motors having imitation stator winding were installed with 80pF capacitive couplers at the terminal box Case of PD Pattern regarding applied voltage phase angel, the PD patterns were displayed two dimensional and three dimensional. TGA summarizes each plot with two quantities such as the normalized quantity number(NQN) and the peak PD magnitude(Qm). As the result, we could discrimidate using TGA the difference of internal and surface discharge for imitation stator winding. We have used the other technique, in order to feature extraction of faulty signals on stator winding, Daubechies Discrete wavelet transform and Harmonics analysis(FFT) about faulty signals.

  • PDF

Spin Valve Effect in Lateral Py/Au/Py Devices

  • Ku, Jang-Hae;Chang, Joon-Yeon;Koo, Hyun-Cheol;Eom, Jong-Hwa;Han, Suk-Hee;Kim, Gyu-Tae
    • Journal of Magnetics
    • /
    • v.12 no.4
    • /
    • pp.152-155
    • /
    • 2007
  • Spin dependent transport was investigated in lateral $Py(Ni_{81}Fe_{19})/Au/Py$ spin valve devices. Clear spin valve effect was observed in conventional four-terminal measurement geometry. Higher resistance was found in antiparallel magnetization field of two Py electrodes which is determined by anisotropy magnetoresistance (AMR) measurements. The rectangular shape of spin signal together with good agreement of switching field convinces observed spin valve signal is resulted from effective spin injection and detection. The magnetoresistance ratio decays exponentially with channel length by which spin diffusion length of Au channel was estimated to be 76 nm.

Two new records of orb-weaving spiders with a new species (Araneae: Araneidae) from Korea

  • Lee, Sue Yeon;Yoo, Jung Sun;Kim, Seung Tae
    • Journal of Species Research
    • /
    • v.10 no.4
    • /
    • pp.387-391
    • /
    • 2021
  • Araneidae Clerck, 1757 is one of the largest families within the order Araneae Clerck, 1757, comprising 3,065 species in 177 genera. To date, two species of the genus Mengora O. Pickard-Cambridge, 1889 and four species of the genus Araniella Chamberlin & Ivie, 1942 have been recorded in Korea. During a seasonal survey of the spider fauna in mountainous terrain conducted from 2018 to 2019, females of Mangora foliosa Zhu & Yin, 1998 and a male of Araniella robusta sp. nov. were collected with a sweep net between shrubs in mixed forests from Mt. Juwangsan National Park. In this paper, we provide a diagnosis of the new species and descriptions including measurements and morphological illustrations. The new species, Araniella robusta sp. nov., can be easily distinguished from other species in the genus Araniella Chamberlin & Ivie, 1942 by a branched conductor with two blunt tips and conjugation of the embolus tip and terminal apophysis.

Association between dietary intake, body measurements, and urinary bone resorption markers in young adults with osteopenia and osteoporosis: a cross-sectional study

  • Mi-Hyun Kim;Mi-Kyeong Choi
    • Korean Journal of Community Nutrition
    • /
    • v.28 no.4
    • /
    • pp.282-292
    • /
    • 2023
  • Objectives: Bone health in early adulthood, as individuals approach peak bone mass, plays a critical role in preventing osteoporosis later in life. This study aimed to investigate the associations between lifestyle and dietary factors, anthropometric measurements, and urinary bone resorption markers in young adults. Methods: A cross-sectional study was conducted with 100 healthy Korean adults (50 men and 50 women) in their 20s and early 30s. Bone mineral density (BMD), anthropometric measurements, dietary intake (24-hour recall), and urinary bone resorption indicators (deoxypyridinoline and N-terminal telopeptide of type I collagen) were analyzed. Variables were compared between the osteopenia and osteoporosis groups (OSTEO group: 30% men and 60% women) and the healthy control group. Results: Men in the OSTEO group were significantly taller than those in the control group (P < 0.05). Women in the OSTEO group had significantly lower body weight and body composition (muscle and body fat) than those in the normal group (P < 0.01). Men in the OSTEO group had a significantly higher intake of animal calcium (Ca) than those in the normal group (P < 0.05). Women in the OSTEO group had significantly higher dietary fiber, vitamin A, Ca, plant Ca, and potassium intake than did those in the normal group (P < 0.05). There were no significant differences in caffeinated beverage consumption, eating habits, or urinary bone resorption indicators between the OSTEO and control groups of either sex. Conclusions: In our study of young South Korean adults, we observed low bone density levels, with particularly low BMD in taller men and underweight women. We found a higher nutrient intake in the OSTEO group, indicating the possibility of reverse causality, a phenomenon often found in cross-sectional studies. Therefore, there is a need to further elucidate dietary factors related to osteoporosis in young adults through prospective cohort studies involving a larger population.