레이더를 이용한 콘크리트 교량의 바닥판 상태평가 (Condition Evaluation of Concrete Bridge Decks using CPR)

  • 서진원;이지영;이일용
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제4권4호
    • /
    • pp.101-107
    • /
    • 2000
  • In this study, the Ground Penetrating Radar(GPR) was tested to evaluate the condition of concrete decks. Test results obtained by CPR were compared with values measured from drilled cores and damage mapping by the visual survey. It is shown that GPR can provide highly accurate measurements of layer properties of concrete decks and can map areas of deterioration in bridge decks by dielectric constants. The deck condition can be grouped into categories of "good" or "distressed". The ground penetrating radar data shows promise for producing rapid and accurate condition assessment for bridge decks. And these data can be used to evaluate highway bridge condition and make cost-effective bridge deck rehabilitation by accurately estimating the quantity of deteriorated concrete.

  • PDF

사장교 콘크리트 주탑의 온도영향 평가 (Evaluation of Thermal Effect on the Concrete Pylon of a Cable-stayed Bridge)

  • 박종칠;김영진;최성권;이충표
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.355-358
    • /
    • 2005
  • In this paper, an actual behavior of the pylon of Seohae Grand Bridge which is a cable stayed bridge and has been constructed 4 years ago was analyzed by using data acquisition system. As a result, the pylon of cable stayed bridge behaved normally with respect to the change of temperature. The annual displacement of the top of pylon(PY1) ranged from -71.4mm to +181.7mm in the longitudinal direction of the bridge. In the case of the longitudinal displacement, the displacement of PY1 was bigger than that of PY2 because PY1 is movable and PY2 is fixed in terms of the constraint condition of super structure. For the long term, PY1 will be sloped gently to the direction of Dangjin and PY2 will be also sloped gently to the direction of Pyongtaek by the effect of creep and shrinkage in the case of the longitudinal direction. The result of structural analysis showed good agreement with the result mentioned above.

  • PDF

Equivalent moment of inertia of a truss bridge with steel-concrete composite deck

  • Siekierski, Wojciech
    • Structural Engineering and Mechanics
    • /
    • 제55권4호
    • /
    • pp.801-813
    • /
    • 2015
  • Flexural stiffness of bridge spans has become even more important parameter since Eurocode 1 introduced for railway bridges the serviceability limit state of resonance. For simply supported bridge spans it relies, in general, on accurate assessment of span moment of inertia that governs span flexural stiffness. The paper presents three methods of estimation of the equivalent moment of inertia for such spans: experimental, analytical and numerical. Test loading of the twin truss bridge spans and test results are presented. Recorded displacements and the method of least squares are used to find an "experimental" moment of inertia. Then it is computed according to the analytical method that accounts for joint action of truss girders and composite deck as well as limited span shear stiffness provided by diagonal bracing. Finally a 3D model of finite element method is created to assess the moment of inertia. Discussion of results is given. The comparative analysis proves efficiency of the analytical method.

Bridge Resistance Deviation-to-Period Converter for Resistive Biosensors

  • Bae, Cheol-Soo
    • 한국정보전자통신기술학회논문지
    • /
    • 제7권4호
    • /
    • pp.195-199
    • /
    • 2014
  • A bridge resistance deviation-to-period (BRD-to-P) converter is presented for interfacing resistive biosensors. It consists of a linear operational transconductance amplifier (OTA) and a current-controlled oscillator (CCO) formed by a current-tunable Schmitt trigger and an integrator. The free running period of the converter is 1.824 ms when the bridge offset resistance is $1k{\Omega}$. The conversion sensitivity of the converter amounts to $3.814ms/{\Omega}$ over the resistance deviation range of $0-1.2{\Omega}$. The linearity error of the conversion characteristic is less than ${\pm}0.004%$.

비접촉식 배터리 충전 장치용 Half-Bridge 직렬 공진 컨버터 분석 및 설계 (Analysis and Design of Half-Bridge Resonant Converter for Non-Contact Battery Charger)

  • 김창균;서동현;유정식;박종후;조보형
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권4호
    • /
    • pp.265-271
    • /
    • 2000
  • A non-contact battery charger for cellular phone is designed using half-bridge series resonant converter. This converter utilizes series resonance to reduce the undesirable effect of large leakage inductance of the detachable transformer and ZVS operation can reduce switching loss and switching noise. In this paper, analysis and design procedure of half-bridge series resonant converter with detachable transformer is presented. The input voltage is 85VAC∼270VAC, and the output voltage and current is 4.1V and 800mA, respectively. Furthermore, a method of calculating the secondary current of the transformer to control the battery charging current in the constant current charging mode is proposed. The performance of the charger is verified through experiments.

  • PDF

Analytical and experimental study on aerodynamic control of flutter and buffeting of bridge deck by using mechanically driven flaps

  • Phan, Duc-Huynh;Kobayshi, Hiroshi
    • Structural Engineering and Mechanics
    • /
    • 제46권4호
    • /
    • pp.549-569
    • /
    • 2013
  • A passive control using flaps will be an alternative solution for flutter stability and buffeting response of a long suspension bridge. This method not only enables a lightweight economic stiffening girder without an additional stiffness for aerodynamic stability but also avoid the problems from the malfunctions of control systems and energy supply system of an active control by winglets and flaps. A time domain approach for predicting the coupled flutter and buffeting response of bridge deck with flaps is investigated. First, the flutter derivatives of bridge deck and flaps are found by experiment. Next, the derivation of time domain model of self-excited forces and control forces of sectional model is reported by using the rational function approximation. Finally, the effectiveness of passive flap control is investigated by the numerical simulation. The results show that the passive control by using flaps can increase the flutter speed and decrease the buffeting response. The experiment results are matched with numerical ones.

Delayed Lateral Row Anchor Failure in Suture Bridge Rotator Cuff Repair: A Report of 3 Cases

  • Jeong, Jae-Jung;Ji, Jong-Hun;Park, Seok-Jae
    • Clinics in Shoulder and Elbow
    • /
    • 제21권4호
    • /
    • pp.246-251
    • /
    • 2018
  • Compared to single row repair, use of lateral row anchors in suture bridge rotator cuff repair enhances repair strength and increases footprint contact area. If a lateral knotless anchor (push-in design) is inserted into osteoporotic bone, pull-out of the lateral row anchor can developed. However, failures of lateral row anchors have been reported at several months after surgery. In our cases, even though complete cuff healing occurred, delayed pull-out of the lateral row anchor in the suture bridge repair occurred. In comparison to a conventional medial anchor, further biomechanical evaluation of the pull-out force, design, and insertion angle of the lateral anchor is needed in future studies. We report three cases with delayed pull-out of lateral row anchor in suture bridge rotator cuff repair with a literature review.

보수전과 후의 홍예교의 동적특성과 구조성능에 대한 해석연구 (Analytical Study of a Historic Stone Arch Bridge After Retrofit to Evaluate Dynamic Characteristics and Structural Behavior)

  • 이가윤;이성민;이기학
    • 한국공간구조학회논문집
    • /
    • 제20권4호
    • /
    • pp.177-184
    • /
    • 2020
  • This study evaluates safety assessment before and after repair of Seonamsa temple seungseon bridge, which refer to the representative Hongye bridge in Korea. In this approach natural frequency of the structure were considered in the modeling procedure. Trial & error method is applied to obtain the approximate natural frequency before and after retrofit construction. Stiffness of the actual structure was examined to account for the dynamic characteristics of Hongye bridge measured in the field and adjusting parameters in computer modeling. The safety and usability of the stone structure in terms of load bearing capacity and displacement were examined.

${\pi}$형 거더를 가진 4경간 사장교의 동적거동에 관한 실험적 연구 (An Experimental Study on the dynamic behavior of 4-Span Cable-Stayed Bridge with ${\pi}$-Type Girder)

  • 조재영;김영민;이학은;윤기용
    • 한국방재학회 논문집
    • /
    • 제4권1호
    • /
    • pp.15-24
    • /
    • 2004
  • 일반적으로, 2개의 I형 거더로 이루어진 ${\pi}$형거더는 공기역학적으로 불안하여 내풍설계에 있어 매우 불리 한 것으로 알려져 있다. 공기역학적 진동은 구조물의 강성이나 감쇠의 향상, 단면 형상의 연구 등에 의해 억제될 수 있으므로 본 연구에서는 ${\pi}$ 형단면을 가진 4경간 사장교에 대해 영각과 공기역학적 제진장치의 추가로 인한 단면의 변화에 따른 2차원 진동실험을 통하여 공기역학적 특성을 파악하도록 하였다. 등류와 난류에서의 실험결과 본 교량단면은 기본단면만으로도 내풍안정성을 충분히 갖추고 있기 때문에 페어링(Fairing) 및 베플(Baffle Plate) 등의 추가적인 공기역학적 제진장치가 필요하지 않을 것으로 판단된다. 이는 본 교량의 경우 주경간이 230m인 4경간으로 이루어져 있어 비슷한 단면을 가진 교량에 비하여 수직 및 비틀림 진동수가 크고 강성이 크기 때문에 설계풍속 내에서 공기역학적으로 안정한 것으로 보여진다.