• Title/Summary/Keyword: 4 inch)

Search Result 529, Processing Time 0.026 seconds

Revision Volume of Square-inch-spoon, Jeon-bi and Firmiana-Seed-sized Pill Preparations in 『Treatise on Cold Damage Diseases』 (『상한론』에서 산제의 방촌비와 전비, 환제의 오동자대 크기 수정치)

  • Kim, In-Rak
    • The Korea Journal of Herbology
    • /
    • v.37 no.5
    • /
    • pp.75-81
    • /
    • 2022
  • Objectives : In 『Treatise on Cold Damage Diseases』, the volume of preparation dosage measured in Hap was 6.5mL. This study aimed to confirm that a square-inch-spoon, which measures powder preparation dosage, was 1/3 Hap, and that Jeon-bi was 1/8 square-inch-spoon. Based on these values, this study also aimed to adjust the diameter of Firmiana-Seed-sized pill preparation, currently known as 6.5mm, so that one square-inch-spoon of powder preparation creates 16 pills. Methods : Calculated the ratio between the floor areas of square-inch-spoon and Jeon-bi and measured the ratio of volume; assumed that powder preparations were stacked as much as possible in the shape of a square pyramid when scooped comfortably, then calculated the slopes of 1/3 Hap and 1/4 Hap; measured the volumes of powdered Oryeongsan and Lijungwhan in square-inch-spoon and Jeon-bi; created the powders into Firmiana-Seed-sized pill preparation; adjusted the diameter of Firmiana Seed so that 16 pills could be created. Results : Inferring from the floor areas, the volume of square-inch-spoon is 9.2 times that of Jeon-bi; one square-inch-spoon should be 1/3 Hap for the powder to reach its maximum slope of 47° and, according to actual measurement of powder preparations, reach its maximum volume; when created into Firmiana-Seed-sized pill preparations, one square-inch-spoon should be 1/3 Hap so that approximately 16 pills were created. Conclusions : One square-inch-spoon of powder preparation was 1/3 Hap(2.17mL), Jeon-bi was 1/8 square-inch-spoon(0.27mL), and the diameter of Firmiana-Seed-sized pill preparation was 5.5mm.

A Study on Characteristics of Si doped 3 inch GaAs Epitaxial Layer Grown by MBE for LSI Application (LSI급 소자 제작을 위한 3인치 GaAs MBE 에피택셜 기판의 균일도 특성 연구)

  • 이재진;이해권;맹성재;김보우;박형무;박신종
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.7
    • /
    • pp.76-84
    • /
    • 1994
  • The characteristics of 3 inch wafer scale GaAs epitaxial wafer grown by molecular beam epitaxy for LSI process application were studied. The thickness and doping uniformity are characterized and discussed. The growth temperature and growth rate were $600^{\circ}C$ by pyrometer, and 1 $\mu$m/h, respectively. It was found that thickness and doping uniformity were 3.97% and 4.74% respectively across the full 3 inch diameter GaAs epitaxial layer. Also, ungated MESFETs have been fabricated and saturation current measurement showed 4.5% uniformity on 3 inch, epitaxial layer, but uniformity of threshold voltage increase up to 9.2% after recess process for MESFET device.

  • PDF

Current Status and Technology of Plasma Displays (플라즈마 디스플레이의 기술과 현황)

  • 강정원;김영섭
    • Journal of the Semiconductor & Display Technology
    • /
    • v.3 no.4
    • /
    • pp.1-4
    • /
    • 2004
  • 21세기에 접어들면서 Digital시험방송의 시작과 다양한 Contents의 유입으로 평판디스플레이 (Flat Panel Display)에 관한 관심과 수요가 증가하고 있다. 이 중 PDP는 90년대 후반부터 양산 및 개발을 시작하여 현재는 40 inch에서 60 inch 화면 크기의 제품을 시장에서 구입할 수 있으며, 03년도에는 80 inch 크기의 Proto-type Model을 공개한 바 있다. PDP는 40 inch 이상의 대면적 구현이 용이하다는 점, CRT와 동등 수준의 화상 구현이 가능하다는 점, 제조공법이 간단하고 제조원가가 저렴하다는 점 등을 특징으로 시장을 확대하고 있으나, 좀 더 대중적인 디스플레이가 되기 위해서는 고휘도 및 고효율화, 화질개선 그리고 저가격화 등과 같은 과제를 해결하여야 한다. 본 논문에서는 PDP의 개발역사 및 시장현황, 구조 및 구동 방법 그리고 해결과제 및 전망에 대해서 포괄적으로 살펴보기로 한다.

  • PDF

A study on the growth of 3 inch grade AlN crystal (직경 3인치의 AlN 단결정 성장에 관한 연구)

  • Kang, Seung-Min
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.29 no.3
    • /
    • pp.140-142
    • /
    • 2019
  • AlN (Aluminum Nitride) crystal which could be used to substrates for UV LEDs was grown by PVT ((Physical Vapor Transport) method. 3 inch AlN single crystal with a thickenss of 4 mm was grown using Polycrystalline seed for 120 hours. In this report, a result of 3 inch polycrystalline bulk AlN growth behavior using large size crucible and growth condition were reported.

4 Inch Wafer-Scale Replicability Enhancement in Hot Embossing by using PDMS-Cushioned Si Mold (PDMS 쿠션을 갖는 Si 몰드에 의한 핫엠보싱 공정에서의 4 인치 웨이퍼 스케일 전사성 향상)

  • Kim Heung-Kyu;Ko Young-Bae;Kang Jeong-Jin;Heo Young-Moo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.8 s.185
    • /
    • pp.178-184
    • /
    • 2006
  • Hot embossing is to fabricate desired pattern on the polymer substrate by pressing the patterned mold against the substrate which is heated above the glass transition temperature, and it is a high throughput fabrication method for bio chip, optical microstructure, etc. due to the simultaneous large area patterning. However, the bad pattern fidelity in large area patterning is one of the obstacles to applying the hot embossing technology for mass production. In the present study, PDMS pad was used as a cushion on the backside of the micro-patterned 4 inch Si mold to improve the pattern fidelity over the 4 inch PMMA sheet by increasing the conformal contact between the Si mold and the PMMA sheet. The pattern replicability improvement over 4 inch wafer scale was evaluated by comparing the replicated pattern height and depth for PDMS-cushioned Si mold against the rigid Si mold without PDMS cushion.

Performance of Airlift Pumps for Water Circulation and Aeration (물 순환 및 에어레이션용 에어리프트 펌프의 성능)

  • OH Se-Kyung
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.25 no.6
    • /
    • pp.529-537
    • /
    • 1992
  • Airlift pumps were tested to evaluate their pumping and aeration capacities. The pumps were 34.5 inch long made of 2, 3, 4 and 6 inch nominal diameter PVC pipes. An one hp air blower was used to supply the air. The air-flow rate was measured by an anemometer type air-flow meter and air pressure was level changes in a water tank from which water was pumped. Aeration by the pumps was tested by the standard aeration test method with the center of pump outlet positioned 3 inches above water surface. Oxygen concentrations in water were measured to determine aeration rate. As pumping head increased by water level draw-down in the tank water flow decreased while air flow increased. The reduction rate of water flow was higher with 4 and 6-inch pumps. Small pumps showed very minor changes in the reduction. Aeration rates were similar among 3, 4, and 6 inch pumps. With one hp air blower 6-inch pump at the minimum pumping head achieved the best performance in terms of water circulation.

  • PDF

Comparison of frictional forces between aesthetic orthodontic coated wires and self-ligation brackets

  • Kim, Yunmi;Cha, Jung-Yul;Hwang, Chung-Ju;Yu, Hyung Seog;Tahk, Seon Gun
    • The korean journal of orthodontics
    • /
    • v.44 no.4
    • /
    • pp.157-167
    • /
    • 2014
  • Objective: The purpose of this study was to evaluate the clinical efficacy of polymer- and rhodium-coated wires compared to uncoated wires by measuring the frictional forces using self-ligation brackets. Methods: 0.016-inch nickel titanium (NiTi) wires and $0.017{\times}0.025$-inch stainless steel (SS) wires were used, and the angulations between the brackets and wires were set to $0^{\circ}$, $5^{\circ}$, and $10^{\circ}$. Upper maxillary premolar brackets (Clippy-C$^{(R)}$) with a 0.022-inch slot were selected for the study and a tensile test was performed with a crosshead speed of 5 mm/min. The maximum static frictional forces and kinetic frictional forces were recorded and compared. Results: The maximum static frictional forces and the kinetic frictional forces of coated wires were equal to or higher than those of the uncoated wires (p < 0.05). The maximum static frictional forces of rhodium-coated wires were significantly higher than those of polymercoated wires when the angulations between the brackets and wires were set to (i) $5^{\circ}$ in the 0.016-inch NiTi wires and (ii) all angulations in the $0.017{\times}0.025$-inch SS wires (p < 0.05). The kinetic frictional forces of rhodium-coated wires were higher than those of polymer-coated wires, except when the angulations were set to $0^{\circ}$ in the 0.016-inch NiTi wires (p < 0.05). Conclusions: Although the frictional forces of the coated wires with regards to aesthetics were equal to or greater than those of the uncoated wires, a study under similar conditions regarding the oral cavity is needed in order to establish the clinical implications.

The Simulation and Forecast Model for Human Resources of Semiconductor Wafer Fab Operation

  • Tzeng, Gwo-Hshiung;Chang, Chun-Yen;Lo, Mei-Chen
    • Industrial Engineering and Management Systems
    • /
    • v.4 no.1
    • /
    • pp.47-53
    • /
    • 2005
  • The efficiency of fabrication (fab) operation is one of the key factors in order for a semiconductor manufacturing company to stay competitive. Optimization of manpower and forecasting manpower needs in a modern fab is an essential part of the future strategic planing and a very important to the operational efficiency. As the semiconductor manufacturing technology has entered the 8-inch wafer era, the complexity of fab operation increases with the increase of wafer size. The wafer handling method has evolved from manual mode in 6-inch wafer fab to semi-automated or fully automated factory in 8-inch and 12-inch wafer fab. The distribution of manpower requirement in each specialty varied as the trend of fab operation goes for downsizing manpower with automation and outsourcing maintenance work. This paper is to study the specialty distribution of manpower from the requirement in a typical 6-inch, 8-inch to 12-inch wafer fab. The human resource planning in today’s fab operation shall consider many factors, which include the stability of technical talents. This empirical study mainly focuses on the human resource planning, the manpower distribution of specialty structure and the forecast model of internal demand/supply in current semiconductor manufacturing company. Considering the market fluctuation with the demand of varied products and the advance in process technology, the study is to design a headcount forecast model based on current manpower planning for direct labour (DL) and indirect labour (IDL) in Taiwan’s fab. The model can be used to forecast the future manpower requirement on each specialty for the strategic planning of human resource to serve the development of the industry.

An experimental study of dynamic frictional resistance between orthodontic bracket and arch wire (교정용 브라켓과 강선 사이의 운동마찰저항력에 관한 실험적 연구)

  • Lee, Jae-Hwan;Lee, Ki-Soo
    • The korean journal of orthodontics
    • /
    • v.31 no.4 s.87
    • /
    • pp.467-477
    • /
    • 2001
  • This investigation was designed to determine the effects of wire size, bracket width and the number of bracket on bracket-wire dynamic frictional resistance during simulating arch wire-guided tooth movement in vitro. For simulation of an arch wire-guided tooth movement, we simulated tooth, periodontal ligament and cancellous bone. Maxillary premolar and 1st molar were simulated as real sized resin teeth, the simulated resin teeth which its root was coated by polyether impression material which its elastic modulus is similar to periodontal ligament were embedded in steel housing with inlay wax which its elastic modulus is similar to cancellous bone. Stainless steel wires in four wire size (0.016, 0.018, $0.016\;{\times}\;0.022,\;0.019\;{\times}\;0.025$ inch) were examined with respect to three (stainless steel) bracket widths (2.4, 3.0, 4.3mm) and the number of medium bracket(one, two, three) included in the experimental assembly under dry condition. The wires were ligated into the brackets with elastomeric module. The results were as follows : 1. In all the brackets, frictional resistance increased with increase in wire size. But, statistically similar levels of frictional resistance were observed between 0.018 inch and $0.016\;{\times}\;0.022$ inch wires in narrow bracket and also between 0.016 inch and 0.018 inch wire in wide backet. 2. The frictional forces produced by 0.016 inch wire were statistically similar levels in all the brackets. In 0.018 inch round wire, wide bracket was associated with lower amounts of friction than both narrow and medium brackets. In $0.016\;{\times}\;0.022,\;0.019\;{\times}\;0.025$ inch rectangular wire, wide bracket produced target friction than both narrow and medium brackets. In all the wirer, narrow and medium bracket demonstrated no statistical difference in levels of frictional resistance. 3. Frictional resistance increased with increase In number of medium bracket. 0.016 inch round wire demonstrated the greatest increment in frictional resistance, followed by $0.019\;{\times}\;0.025,\;0.016\;{\times}\;0.022$ inch rectangular wire which were similar level in increment of frictional resistance, 0.018 inch wire demonstrated the least increment. The increments of frictional resistance were not constantly direct proportion to number of bracket.

  • PDF

The Effect of Number of Twists of Lyocell Yarns on Compression Property and Abrasion Resistance Blanket Fabrics (라이오셀방적사의 꼬임수에 따른 담요직물의 압축특성과 마모강도)

  • Song, Min-Kyu
    • Fashion & Textile Research Journal
    • /
    • v.8 no.3
    • /
    • pp.363-369
    • /
    • 2006
  • In this the study, Lyocell fabrics for blanket were developed to get high value added goods for elder and Infant. Therefore, the purpose of the study was determine the effect of twist per inch on the physical properties of developed fabrics, including compression property and abrasion resistance on the process for making Lyocell combined yarns. For comparison, commonly used cotton blanket was used. The results were as the follows: 1) Dimensional changes of Lyocell fabrics was in -3% which value was pretty stable, and antistatic property was very good with 10V of electric propensity voltage which means there was no static electricity at all. Pilling property of Lyocell fabrics showed 3 grade which was good and air permeability and moisture vapor transmission rate of Lyocell fabrics were higher than those of cotton fabric and keeping warmth rate of Lyocell fabrics was about 50% which means it very warms. 2) Twist per inch of Lyocell combined yarns increased with tensile strength and elongation of Lyocell fabrics. 3) Twist per inch of Lyocell combined yarns increased with decreasing thickness reduction rate and therefore, compression property of those was pretty good. Specially, compression property of Lyocell fabrics made with yarns of 3.9TPI was better than those of cotton fabric. 4) Twist per inch of Lyocell combined yarns increased with abrasion resistance of Lyocell fabrics.