• Title/Summary/Keyword: 4중 대역

Search Result 336, Processing Time 0.026 seconds

A Preemptive Detection Method for Unknown IoT Botnet Based on Darknet Traffic (다크넷 트래픽 기반의 알려지지 않은 IoT 봇넷 선제탐지 방안)

  • Gunyang Park;Jungsuk Song;Heejun Roh
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.33 no.2
    • /
    • pp.267-280
    • /
    • 2023
  • With development of computing and communications technologies, IoT environments based on high-speed networks have been extending rapidly. Especially, from home to an office or a factory, applications of IoT devices with sensing environment and performing computations are increasing. Unfortunately, IoT devices which have limited hardware resources can be vulnerable to cyber attacks. Hence, there is a concern that an IoT botnet can give rise to information leakage as a national cyber security crisis arising from abuse as a malicious waypoint or propagation through connected networks. In order to response in advance from unknown cyber threats in IoT networks, in this paper, We firstly define four types of We firstly define four types of characteristics by analyzing darknet traffic accessed from an IoT botnet. Using the characteristic, a suspicious IP address is filtered quickly. Secondly, the filtered address is identified by Cyber Threat Intelligence (CTI) or Open Source INTelligence (OSINT) in terms of an unknown suspicious host. The identified IP address is finally fingerprinted to determine whether the IP is a malicious host or not. To verify a validation of the proposed method, we apply to a Darknet on real-world SOC. As a result, about 1,000 hosts who are detected and blocked preemptively by the proposed method are confirmed as real IoT botnets.

QRAS-based Algorithm for Omnidirectional Sound Source Determination Without Blind Spots (사각영역이 없는 전방향 음원인식을 위한 QRAS 기반의 알고리즘)

  • Kim, Youngeon;Park, Gooman
    • Journal of Broadcast Engineering
    • /
    • v.27 no.1
    • /
    • pp.91-103
    • /
    • 2022
  • Determination of sound source characteristics such as: sound volume, direction and distance to the source is one of the important techniques for unmanned systems like autonomous vehicles, robot systems and AI speakers. There are multiple methods of determining the direction and distance to the sound source, e.g., using a radar, a rider, an ultrasonic wave and a RF signal with a sound. These methods require the transmission of signals and cannot accurately identify sound sources generated in the obstructed region due to obstacles. In this paper, we have implemented and evaluated a method of detecting and identifying the sound in the audible frequency band by a method of recognizing the volume, direction, and distance to the sound source that is generated in the periphery including the invisible region. A cross-shaped based sound source recognition algorithm, which is mainly used for identifying a sound source, can measure the volume and locate the direction of the sound source, but the method has a problem with "blind spots". In addition, a serious limitation for this type of algorithm is lack of capability to determine the distance to the sound source. In order to overcome the limitations of this existing method, we propose a QRAS-based algorithm that uses rectangular-shaped technology. This method can determine the volume, direction, and distance to the sound source, which is an improvement over the cross-shaped based algorithm. The QRAS-based algorithm for the OSSD uses 6 AITDs derived from four microphones which are deployed in a rectangular-shaped configuration. The QRAS-based algorithm can solve existing problems of the cross-shaped based algorithms like blind spots, and it can determine the distance to the sound source. Experiments have demonstrated that the proposed QRAS-based algorithm for OSSD can reliably determine sound volume along with direction and distance to the sound source, which avoiding blind spots.

Effect of LED Light Wavelength on Lettuce Growth, Vitamin C and Anthocyanin Contents (LED광 파장이 상추생육과 비타민 C 및 안토시아닌 함량에 미치는 영향)

  • Choi, Man Kwon;Baek, Gyeong Yun;Kwon, Soon Joo;Yoon, Yong Cheol;Kim, Hyeon Tae
    • Journal of Bio-Environment Control
    • /
    • v.23 no.1
    • /
    • pp.19-25
    • /
    • 2014
  • In this study, we analyzed the growth characteristics of red lettuce under Light-emitting diode (LED) light environment as well as the change of vitamin C and anthocyanins of lettuce. We made five monochromatic light treatments (red 647 nm, 622 nm, blue 463 nm, 450 nm, White), six mixed red (R) and blue (B) light treatments (R : B = 9 : 1, 8 : 2, 7 : 3, 6 : 4, 5 : 5) and red + white, and three light treatments made according to photoperiod of LED with lighting sources ratio of red : blue (R : B = 8 : 2(18/06 h, 15/09 h, 12/12 h)). It was composed of totally 14 control beds. As a result, the red lettuce the most developed leaf height, leaf numbers and fresh weight under red single light, root length and leaf developed when grown under blue single light. Therefore, red light were related to above part of the lettuce, blue light were related to the growth of the underground part of lettuce. Case of the mixed light, leaf height, leaf numbers, fresh/dry weight of above and underground part were highest red + white light and root length and chlorophyll content were highest under red 7 : 3 blue light. Result of growing investigation by photoperiod, the red lettuce were considered to be most effective in 15/09 h (on/off). The content of anthocyanins; the single light source, mixed light and light irradiation period were highest under blue light (463 nm), red 7 : 3 blue and 18/06 h (on/off) light irradiation, respectively. The vitamin C showed the lowest content of $1.26mg{\cdot}L^{-1}$ under the white light, but showed the greatest content of $3.02mg{\cdot}L^{-1}$ for the control group.

Seismic wave propagation through surface basalts - implications for coal seismic surveys (지표 현무암을 통해 전파하는 탄성파의 거동 - 석탄 탄성파탐사에 적용)

  • Sun, Weijia;Zhou, Binzhong;Hatherly, Peter;Fu, Li-Yun
    • Geophysics and Geophysical Exploration
    • /
    • v.13 no.1
    • /
    • pp.1-8
    • /
    • 2010
  • Seismic reflection surveying is one of the most widely used and effective techniques for coal seam structure delineation and risk mitigation for underground longwall mining. However, the ability of the method can be compromised by the presence of volcanic cover. This problem arises within parts of the Bowen and Sydney Basins of Australia and seismic surveying can be unsuccessful. As a consequence, such areas are less attractive for coal mining. Techniques to improve the success of seismic surveying over basalt flows are needed. In this paper, we use elastic wave-equation-based forward modelling techniques to investigate the effects and characteristics of seismic wave propagation under different settings involving changes in basalt properties, its thickness, lateral extent, relative position to the shot position and various forms of inhomogeneity. The modelling results suggests that: 1) basalts with high impedance contrasts and multiple flows generate strong multiples and weak reflectors; 2) thin basalts have less effect than thick basalts; 3) partial basalt cover has less effect than full basalt cover; 4) low frequency seismic waves (especially at large offsets) have better penetration through the basalt than high frequency waves; and 5) the deeper the coal seams are below basalts of limited extent, the less influence the basalts will have on the wave propagation. In addition to providing insights into the issues that arise when seismic surveying under basalts, these observations suggest that careful management of seismic noise and the acquisition of long-offset seismic data with low-frequency geophones have the potential to improve the seismic results.

Acquisition of Monochromatic X-ray using Graded Multilayer Mirror (Graded 다층박막거울을 이용한 단색 엑스선 획득)

  • Ryu, Cheolwoo;Choi, Byoungjung;Son, Hyunhwa;Kwon, Youngman;Kim, Byoungwook;Kim, Youngju;Chon, Kwonsu
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.4
    • /
    • pp.205-211
    • /
    • 2015
  • At a recent medical imaging technology, the major issue of X-ray diagnosis in breast cancer is the early detection of breast cancer and low patient's exposure dose. As one of studies to acquire a monochromatic X-ray, Technologies using multilayer mirror had been preceded. However, a uniform multilayer mirror that consists of uniform thin-film thickness can acquire a monochromatic X-ray only in the partial area corresponds to angle of incidence of white X-ray, so there are limits for X-ray imaging technology applications. In this study, we designed laterally graded multilayer mirror(below GML) that reflects same monochromatic X-ray over the entire area of thin-film mirror, which have the the thickness of the linear gradient that correspond to angle of incidence of white X-ray. By using ion-beam sputtering system added the mask control system we fabricated a GML which has size of $100{\times}100mm^2$. The GML is designed to achieve the monochromatic X-ray of 17.5kev energy and has thin-film thickness change from 4.62nm to 6.57nm(3.87nm at center). It reflects the monochromatic X-ray with reflectivity of more than 60 percent, FWHM of below 2.6keV and X-ray beam width of about 3mm. The monochromatic X-ray corresponded to 17.5keV using GML would have wide application in development of mammography system with high contrast and low dose.

Effect of the Configuration of Contact Type Textile Electrode on the Performance of Heart Activity Signal Acquisition for Smart Healthcare (스마트 헬스케어를 위한 심장활동 신호 검출용 접촉식 직물전극의 구조가 센싱 성능에 미치는 영향)

  • Cho, Hyun-Seung;Koo, Hye-Ran;Yang, Jin-Hee;Lee, Kang-Hwi;Kim, Sang-Min;Lee, Jeong-Hwan;Kwak, Hwy-Kuen;Ko, Yun-Su;Oh, Yun-Jung;Park, Su-Youn;Kim, Sin-Hye;Lee, Joo-Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.21 no.4
    • /
    • pp.63-76
    • /
    • 2018
  • The purpose of this study was to investigate the effect of contact type textile electrode structure on heart activity signal acquisition for smart healthcare. In this study, we devised six contact type textile electrodes whose electrode size and configuration were manipulated for measuring heart activity signals using computerized embroidery. We detected heart activity signals using a modified lead II and by attaching each textile electrode to the chest band in four healthy male subjects in a standing static posture. We measured the signals four times repeatedly for all types of electrodes. The heart activity signals were sampled at 1 kHz using a BIOPAC ECG100, and the detected original signals were filtered through a band-pass filter. To compare the performance of heart activity signal acquisition among the different structures of the textile electrodes, we conducted a qualitative analysis using signal waveform and size as parameters. In addition, we performed a quantitative analysis by calculating signal power ratio (SPR) of the heart activity signals obtained through each electrode. We analyzed differences in the performance of heart activity signal acquisition of the six electrodes by performing difference and post-hoc tests using nonparametric statistic methods on the calculated SPR. The results showed a significant difference both in terms of qualitative and quantitative aspects of heart activity signals among the tested contact type textile electrodes. Regarding the configurations of the contact type textile electrodes, the three-dimensionally inflated electrode (3DIE) was found to obtain better quality signals than the flat electrode. However, regarding the electrode size, no significant difference was found in performance of heart signal acquisition for the three electrode sizes. These results suggest that the configuration method (flat/3DIE), which is one of the two requirements of a contact type textile electrode structure for heart activity signal acquisition, has a critical effect on the performance of heart activity signal acquisition for wearable healthcare. Based on the results of this study, we plan to develop a smart clothing technology that can monitor high-quality heart activity without time and space constraints by implementing a clothing platform integrated with the textile electrode and developing a performance improvement plan.

On the Suitability of the Korean Standard Time (한국 표준시 제도의 타당성에 대한 연구)

  • Hong, Sung-Gil;Ryu, Chan-Su;Kim, Young-Sung
    • Journal of the Korean earth science society
    • /
    • v.23 no.6
    • /
    • pp.494-506
    • /
    • 2002
  • The Korean Standard-Time (KST) in practice is about 30 minutes earlier than Korea’s solar-time. Suitability of tile KST is analysed by whether it is suitable for the society in general and for the mental and physical health of the Korean people. About 56% of the countries in the world use single standard-time coincident, 18% are 30 minutes earlier, and 21% are an hour or more earlier than their solar-times, respectively, and only 5% have standard-times 30 minutes later than their solar-time. This means adoption of the standard-time earlier than the solar-time is rather acceptable in most countries without any harm to the mental and physical health of their people. Because Korea is located on the western margin of the I-time zone (which is used standard longitude of 135$^{\circ}$E and is used as KST), KST is about 30 minutes earlier than Korea’s solar-time. This situation does not seem to affect adversely the physical, physiological or psychological activities of the people of Korea. It also helps in effective use of the daily time schedule throughout the year, moreover it diminishes the necessity of the summer-time system in the Korea. If H$^{\ast}$-time of the longitude of 127.5$^{\circ}$E that passes through middle of the Korean peninsular is used as KST, non-integer time difference from UTC is inevitable which may be of great inconvenience, and also the introduction of a summer-time system like most countries in high latitude, using their standard-time coincidentally with or even earlier than their solar time, will become essential.

A Review on Monitoring Mt. Baekdu Volcano Using Space-based Remote Sensing Observations (인공위성 원격탐사를 이용한 백두산 화산 감시 연구 리뷰)

  • Hong, Sang-Hoon;Jang, Min-Jung;Jung, Seong-Woo;Park, Seo-Woo
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.6_4
    • /
    • pp.1503-1517
    • /
    • 2018
  • Mt. Baekdu is a stratovolcano located at the border between China and North Korea and is known to have formed through its differentiation stage after the Oligocene epoch in the Cenozoic era. There has been a growing interest in the magma re-activity of Mt. Baekdu volcano since 2010. Several research projects have been conducted by government such as Korea Meteorological Administration and Korea Institute of Geoscience and Mineral Resources. Because, however, the Mt. Baekdu volcano is located far from South Korea, it is quite difficult to collect in-situ observations by terrestrial equipment. Remote sensing is a science to analyze and interpret information without direct physical contact with a target object. Various types of platform such as automobile, unmanned aerial vehicle, aircraft and satellite can be used for carrying a payload. In the past several decades, numerous volcanic studies have been conducted by remotely sensed observations using wide spectrum of wavelength channels in electromagnetic waves. In particular, radar remote sensing has been widely used for volcano monitoring in that microwave channel can gather surface's information without less limitation like day and night or weather condition. Radar interferometric technique which utilized phase information of radar signal enables to estimate surface displacement such as volcano, earthquake, ground subsidence or glacial movement, etc. In 2018, long-term research project for collaborative observation for Mt. Baekdu volcano between Korea and China were selected by Korea government. A volcanic specialized research center has been established by the selected project. The purpose of this paper is to introduce about remote sensing techniques for volcano monitoring and to review selected studies with remote sensing techniques to monitor Mt. Baekdu volcano. The acquisition status of the archived observations of six synthetic aperture radar satellites which are in orbit now was investigated for application of radar interferometry to monitor Mt. Baekdu volcano. We will conduct a time-series analysis using collected synthetic aperture radar images.

Evaluation of Spectral Band Adjustment Factor Applicability for Near Infrared Channel of Sentinel-2A Using Landsat-8 (Landsat-8을 활용한 Sentinel-2A Near Infrared 채널의 Spectral Band Adjustment Factor 적용성 평가)

  • Nayeon Kim;Noh-hun Seong;Daeseong Jung;Suyoung Sim;Jongho Woo;Sungwon Choi;Sungwoo Park;Kyung-Soo Han
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.3
    • /
    • pp.363-370
    • /
    • 2023
  • Various earth observation satellites need to provide accurate and high-quality data after launch. To maintain and enhance the quality of satellite data, it is crucial to employ a cross-calibration process that accounts for differences in sensor characteristics, such as the spectral band adjustment factor (SBAF). In this study, we utilized Landsat-8 and Sentinel-2A satellite imagery collected from desert sites in Libya4, Algeria3, and Mauritania2 among pseudo-invariant calibration sites to calculate and apply SBAF, thereby compensating the uncertainties arising from variations in bandwidths. We quantitatively compared the reflectance differences based on the similarity of bandwidths, including Blue, Green, Red, and both the near-infrared (NIR) narrow, and NIR bands of Sentinel-2A. Following the application of SBAF, significant results with reflectance differences of approximately 1% or less were observed for all bands except NIR. In the case of the Sentinel-2A NIR band, it exhibited a significantly larger bandwidth difference compared to the NIR narrow band. However, after applying SBAF, the reflectance difference fell within the acceptable error range (5%) of 1-2%. It indicates that SBAF can be applied even when there is a substantial difference in the bandwidths of the two sensors, particularly in situations where satellite utilization is limited. Therefore, it was determined that SBAF could be applied even when the bandwidth difference between the two sensors is large in a situation where satellite utilization is limited. It is expected to be helpful in research utilizing the quality and continuity of satellite data.

The study of thermal change by chemoport in radiofrequency hyperthermia (고주파 온열치료시 케모포트의 열적 변화 연구)

  • Lee, seung hoon;Lee, sun young;Gim, yang soo;Kwak, Keun tak;Yang, myung sik;Cha, seok yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.97-106
    • /
    • 2015
  • Purpose : This study evaluate the thermal changes caused by use of the chemoport for drug administration and blood sampling during radiofrequency hyperthermia. Materials and Methods : 20cm size of the electrode radio frequency hyperthermia (EHY-2000, Oncotherm KFT, Hungary) was used. The materials of the chemoport in our hospital from currently being used therapy are plastics, metal-containing epoxy and titanium that were made of the diameter 20 cm, height 20 cm insertion of the self-made cylindrical Agar phantom to measure the temperature. Thermoscope(TM-100, Oncotherm Kft, Hungary) and Sim4Life (Ver2.0, Zurich, Switzerland) was compared to the actual measured temperature. Each of the electrode measurement position is the central axis and the central axis side 1.5 cm, 0 cm(surface), 0.5 cm, 1.8 cm, 2.8 cm in depth was respectively measured. The measured temperature is $24.5{\sim}25.5^{\circ}C$, humidity is 30% ~ 32%. In five-minute intervals to measure the output power of 100W, 60 min. Results : In the electrode central axis 2.8 cm depth, the maximum temperature of the case with the unused of the chemoport, plastic, epoxy and titanium were respectively $39.51^{\circ}C$, $39.11^{\circ}C$, $38.81^{\circ}C$, $40.64^{\circ}C$, simulated experimental data were $42.20^{\circ}C$, $41.50^{\circ}C$, $40.70^{\circ}C$, $42.50^{\circ}C$. And in the central axis electrode side 1.5 cm depth 2.8 cm, mesured data were $39.37^{\circ}C$, $39.32^{\circ}C$, $39.20^{\circ}C$, $39.46^{\circ}C$, the simulated experimental data were $42.00^{\circ}C$, $41.80^{\circ}C$, $41.20^{\circ}C$, $42.30^{\circ}C$. Conclusion : The thermal variations were caused by radiofrequency electromagnetic field surrounding the chemoport showed lower than in the case of unused in non-conductive plastic material and epoxy material, the titanum chemoport that made of conductor materials showed a slight differences. This is due to the metal contents in the chemoport and the geometry of the chemoport. And because it uses a low radio frequency bandwidth of the used equipment. That is, although use of the chemoport in this study do not significantly affect the surrounding tissue. That is, because the thermal change is insignificant, it is suggested that the hazard of the chemoport used in this study doesn't need to be considered.

  • PDF