• Title/Summary/Keyword: 4/3 SRM

Search Result 123, Processing Time 0.027 seconds

β-Carotene Content in Selected Agricultural Foods (조미료류, 채소류, 과일류 등의 농산식품에 함유된 베타카로틴 함량 분석)

  • Shin, Jung-Ah;Choi, Youngmin;Lee, Ki-Teak
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.44 no.3
    • /
    • pp.418-424
    • /
    • 2015
  • The content of ${\beta}$-carotene in agricultural foods, such as seasonings, tea, vegetables, cereals, nuts & seeds, oils & fats, and fruits, were quantitatively analyzed using reversed-phase HPLC with an UV/visible detector. Standard reference material (SRM) 2385 was used as a control material to validate measurement of ${\beta}$-carotene in this study. Recovery percentage and relative standard deviation of ${\beta}$-carotene in SRM 2385 were 102% and 1.73%, respectively. Vegetables and tea contained relatively high concentrations of ${\beta}$-carotene (young barley powder, $17,293.95{\mu}g/100g$; raw young barley, $2,755.15{\mu}g/100g$; dried green tea leaves, $13,671.85{\mu}g/100g$; green tea powder, $7,579.04{\mu}g/100g$). Contents of ${\beta}$-carotene in nuts & seeds as well as oils & fats ranged from $11.32{\mu}g/100g$ in almond products (roasted with salt) to $58.56{\mu}g/100g$ in perilla seed oil. Among 20 fruits, a high content of ${\beta}$-carotene was found in apricots (raw), which contained $2,280.35{\mu}g/100g$.

A Study of Moral Development and Ethical Values of the Nurse (임상 간호사의 도덕성 발달과 윤리적 가치관에 대한 연구)

  • Kim, Mee-Jeong;Kim, Myung-Hee
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.5 no.2
    • /
    • pp.337-353
    • /
    • 1999
  • This study is to provide the basic sources to develop educational data that can establish ethical values with research on the interrelation between moral development and ethical values of nurses. The subjects of this study are the convenience sample from 111 nurses working in clinical settings from 5 general hospitals located in Pusan area. The questionnairs for this study are comprised two parts: Part 1 is SRM-SF(1995) guestionnaire, and translated by Kil, 1m Ju(1997): Part 2 is the guestion papers about the ethical values, and disigned by Jung, Hee Ja. The data were collected from June lth to 31th, 1997 and analyzed by S.A.S(Statistical Analysis System) Package for frequency, percent, and Pearson's correlation coefficient. The results of the study is as the followings: 1) According to the moral development. the nurses are in the levels of Stage3 or Transition3/4, which are generally focused on the personal relations or personality. Thus, nurses are considered to need to get the stage4 of education that helps them recognize a person as a member of society. a family as an unit of society, and human life as the values of human dignity. 2) According to the ethical values, nurses have the positive ethical values of respecting the right of the patients, providing information, keeping the secret, truth. and credit of patients. But they also experience some troubles by the patients to care and the clinical situation. Thus, to overcome the problems, nurses are considered to need to get the education that establishs the right ethical values. 3) The analysis result on the interrelation between moral development level and ethical values shows as r=0.28 and p=0.003. This indicates that the interrelation between them is low. In conclusion, it is considered that the moral development level is viewed broadly from a person and family to a society, and then it can affect to the ethical values positively.

  • PDF

Axisymmetric Swirling Flow Simulation of the Draft Tube Vortex in Francis Turbines at Partial Discharge

  • Susan-Resiga, Romeo;Muntean, Sebastian;Stein, Peter;Avellan, Francois
    • International Journal of Fluid Machinery and Systems
    • /
    • v.2 no.4
    • /
    • pp.295-302
    • /
    • 2009
  • The flow in the draft tube cone of Francis turbines operated at partial discharge is a complex hydrodynamic phenomenon where an incoming steady axisymmetric swirling flow evolves into a three-dimensional unsteady flow field with precessing helical vortex (also called vortex rope) and associated pressure fluctuations. The paper addresses the following fundamental question: is it possible to compute the circumferentially averaged flow field induced by the precessing vortex rope by using an axisymmetric turbulent swirling flow model? In other words, instead of averaging the measured or computed 3D velocity and pressure fields we would like to solve directly the circumferentially averaged governing equations. As a result, one could use a 2D axi-symmetric model instead of the full 3D flow simulation, with huge savings in both computing time and resources. In order to answer this question we first compute the axisymmetric turbulent swirling flow using available solvers by introducing a stagnant region model (SRM), essentially enforcing a unidirectional circumferentially averaged meridian flow as suggested by the experimental data. Numerical results obtained with both models are compared against measured axial and circumferential velocity profiles, as well as for the vortex rope location. Although the circumferentially averaged flow field cannot capture the unsteadiness of the 3D flow, it can be reliably used for further stability analysis, as well as for assessing and optimizing various techniques to stabilize the swirling flow. In particular, the methodology presented and validated in this paper is particularly useful in optimizing the blade design in order to reduce the stagnant region extent, thus mitigating the vortex rope and expending the operating range for Francis turbines.

Accurate Measurement of Isotope Amount Ratios of Lead in Bronze with Multicollector Inductively Coupled Plasma Mass Spectrometry

  • Lee, Kyoung-Seok;Kim, Jin-Il;Yim, Yong-Hyeon;Hwang, Euijin;Kim, Tae Kyu
    • Mass Spectrometry Letters
    • /
    • v.4 no.4
    • /
    • pp.87-90
    • /
    • 2013
  • Isotope amount ratios of lead in a bronze sample have been successfully determined using multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS). Matrix separation conditions were tested and optimized using ion exchange chromatography with anion-exchange resin, AG1-X8, and sequential elution of the 0.5 M HBr and 7 M $HNO_3$ to separate lead from very high contents of copper and tin in bronze matrix. Mercury was also removed efficiently in the optimized separation condition. The instrumental isotope fractionation of lead in the MC-ICP-MS measurement was corrected by the external standard sample bracketing method using an external standard, NIST SRM 981 lead common isotope ratio standard followed by correction of procedure blank to obtain reliable isotope ratios of lead. The isotope ratios, $^{206}Pb/^{204}Pb$, $^{207}Pb/^{204}Pb$, $^{208}Pb/^{204}Pb$, and $^{208}Pb/^{206}Pb$, of lead were determined as $18.0802{\pm}0.0114$, $15.5799{\pm}0.0099$, $38.0853{\pm}0.0241$, and $2.1065{\pm}0.0004$, respectively, and the determined isotope ratios showed good agreement with the reference values of an international comparison for the same sample within the stated uncertainties

Investigation of Nanometals (Ni and Sn) in Platinum-Based Ternary Electrocatalysts for Ethanol Electro-oxidation in Membraneless Fuel Cells

  • Ponmani, K.;Kiruthika, S.;Muthukumaran, B.
    • Journal of Electrochemical Science and Technology
    • /
    • v.6 no.3
    • /
    • pp.95-105
    • /
    • 2015
  • In the present work, Carbon supported Pt100, Pt80Sn20, Pt80Ni20 and Pt80Sn10Ni10 electrocatalysts with different atomic ratios were prepared by ethylene glycol-reduction method to study the electro-oxidation of ethanol in membraneless fuel cell. The electrocatalysts were characterized in terms of structure, morphology and composition by using XRD, TEM and EDX techniques. Transmission electron microscopy measurements revealed a decrease in the mean particle size of the catalysts for the ternary compositions. The electrocatalytic activities of Pt100/C, Pt80Sn20/C, Pt80Ni20/C and Pt80Sn10Ni10/C catalysts for ethanol oxidation in an acid medium were investigated by cyclic voltammetry (CV) and chronoamperometry (CA). The electrochemical results showed that addition of Ni to Pt/C and Pt-Sn/C catalysts significantly shifted the onset of ethanol and CO oxidations toward lower potentials. The single membraneless ethanol fuel cell performances of the Pt80Sn10Ni10/C, Pt80Sn20/C and Pt80Ni20/C anode catalysts were evaluated at room temperature. Among the catalysts investigated, the power density obtained for Pt80Sn10Ni10/C (37.77 mW/cm2 ) catalyst was higher than that of Pt80Sn20/C (22.89 mW/cm2 ) and Pt80Ni20/C (16.77 mW/ cm2 ), using 1.0 M ethanol + 0.5 M H2SO4 as anode feed and 0.1 M sodium percarbonate + 0.5 M H2SO4 as cathode feed.

A Case Study on a Patient with Major Depressive Episode of Bipolar II Disorder Treated with a Combination of Interpersonal and Social Rhythm Therapy and Korean Medicine (제2형 양극성 장애의 주요우울 삽화에 대한 복합 한방 치료 사례보고: 대인관계 및 사회적 리듬 치료와 변증 치료를 중심으로)

  • Lee, Ji-Yoon;Kim, Ju-Yeon;Jeong, Jin-Hyung;Jung, In Chul
    • Journal of Oriental Neuropsychiatry
    • /
    • v.31 no.3
    • /
    • pp.213-223
    • /
    • 2020
  • Objectives: To determine treatment effects of a combination of interpersonal and social rhythm therapy and Korean medicine for a patient with major depressive episode of bipolar II disorder. Methods: A patient was treated with Korean medicine (acupuncture, herbal medicine, etc.) and interpersonal and social rhythm therapy (IPSRT) for four months. Pattern identification for depressive mood and sleep associated symptoms was evaluated using Patient Health Questionnaire-9 (PHQ-9) and Social rhythm metric II-5 (SRM II-5). Results: At the end of the treatment, depression and delayed sleep symptoms were improved and social rhythm was recovered to the regular range. The patient acquired an insight to his interpersonal tensions and conflicts. Conclusions: Korean medicine in combination with interpersonal and social rhythm therapy can be used to treat patients with major depressive episode of bipolar II disorder. More cases are needed to develop guidelines for treating bipolar disorder.

Evaluation of Daily Intake of $^{238} U$ and $^{232} Th$ in a Korean Mixed Diet Sample Using RNAA

  • Chung, Yong-Sam;Moon, Jong-Hwa;Kim, Sun-Ha;Park, Kwang-Won;Kang, Sang-Hoon;Cho, Seung-Yeon
    • Nuclear Engineering and Technology
    • /
    • v.32 no.5
    • /
    • pp.477-484
    • /
    • 2000
  • To estimate the degree of intake of $^{238}$ U and $^{232}$ Th through daily diet, a Korean mixed diet sample was prepared after the investigation of the amount of consumption of the daily diet which corresponds to the age of 20 to 60 years. For the analysis of U and Th, the RNAA method was applied. Two standard reference materials were used for quality control and assurance and the analytical results were compared with a certified value. The determination of U and Th in the Korean mixed diet sample was carried out under the same analytical conditions and procedures with SRM. It is found that the concentration of U and Th in a Korean mixed diet was about 35.4 ppb and 3.4 ppb. From these results, the daily intake of $^{238}$ U and $^{232}$ Th by diet is evaluated to be 6.98 and 0.67 $\mu\textrm{g}$ per day, respectively. Radioactivities related to the intake of $^{238}$ U and $^{232}$ Th were estimated to be about 86 mBq and 27 mBq per person per day and the annual dose equivalents from $^{238}$ U and $^{232}$ Th revealed as 3.18 $\mu$Sv and 0.29 $\mu$Sv per person, respectively.

  • PDF

Ultra-fast Generic LC-MS/MS Method for High-Throughput Quantification in Drug Discovery

  • Kim, So-Hee;Yoo, Hye Hyun;Cha, Eun-Ju;Jeong, Eun Sook;Kim, Ho Jun;Kim, Dong Hyun;Lee, Jaeick
    • Mass Spectrometry Letters
    • /
    • v.4 no.3
    • /
    • pp.47-50
    • /
    • 2013
  • An ultra-fast generic LC-MS/MS method was developed for high-throughput quantification of discovery pharmacokinetic (PK) samples and its reliability was verified. The method involves a simple protein precipitation for sample preparation and the analysis by ultra-fast generic LC-MS/MS with the ballistic gradient program and selected reaction monitoring (SRM) mode. Approximately 290 new chemical entities (NCEs) (over 10,000 samples) from 5 therapeutic programs were analyzed. The calibration curves showed good linearity in the concentration range of 1, 2 or 5 to 2000 ng/mL. No significant ion suppression was observed in the elution region of all the NCEs. When approximately 300 plasma samples were continuously analyzed, the peak area of internal standard was constant and reproducible. In the repeated analysis of samples, the plasma concentrations and the area under the curve (AUC) were consistent with the results from the first analysis. These results showed that the present ultra-fast generic LC-MS/MS method is reliable in terms of selectivity, sensitivity, and reproducibility and could be useful for high-throughput quantification and other bioanalysis in drug discovery.

A Study on Characteristics of Wood Pellet Gasification in Two Stage Gasifier (Two Stage Gasifier에서의 우드펠릿 가스화 특성 연구)

  • Lee, Moon-Won;Choi, Sun-Yong;Kim, Lae-Hyun
    • Journal of Energy Engineering
    • /
    • v.19 no.4
    • /
    • pp.240-245
    • /
    • 2010
  • In this study, characteristics of wood pellet gasification was studied using a Two Stage Gasifier which is consisted of pyrolysis reactor and ultra high temperature reformer. The average yields of $H_2$, $CH_4$, CO, $CO_2$ were 16.7, 11.3, 37.2, 26.6 L/mim, conversion rate from biomass to gas was 65% in pyrolysis reactor and gas yields in reformer were 55.4, 0.8, 120.8, 56.8 L/mim, respectively. The hydrogen flow rate from reformer is obtained 360.1 L/hr. The most of $CH_4$ was decomposed from 12.3 to 0.3 vol.% while $H_2$ is from 18.2 to 23.7 vol.% in reformer by methane dry reforming, Boudouard reaction, oxidation and/or steam reforming. The amount of $H_2O$ generated by hydration reaction from reformer was 1111.8 g, its accelerated conversion of $CH_4$ to other products. The conversion rate from $CH_4$ to other Compounds was 97.2%. Cold gas efficiency was 53.2%.

The Investigation of a Novel Indicator System for Trace Determination and Speciation of Selenium in Natural Water Samples by Kinetic Spectrophotometric Detection

  • Gurkan, Ramazan;Ulusoy, Halil Ibrahim
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.7
    • /
    • pp.1907-1914
    • /
    • 2010
  • A novel catalytic kinetic method is proposed for the determination of Se(IV), Se(VI) and total inorganic selenium in water based on the catalytic effect of Se(IV) on the reduction of bromate by p-nitrophenylhydrazine at pH 3.0. The generated bromine, $Br_2$ or $Cl_2$ plus $Br_2$ in 0.1 M NaCl (or NaBr) environment efficiently decolorized Calmagite and the reaction was monitored spectrophotometrically at 523 nm as a function of time. In this indicator reaction, bromide acted as an activator for the catalysis of selenium (IV) and a reducing agent for selenium (VI) at pH 3.0, which allowed the determination of total selenium. The fixed time method was adopted for the determination and speciation of inorganic selenium. Under the optimum conditions, the calibration graph are linear in the range 1 - 35 ${\mu}gL^{-1}$ of Se(IV) for the fixed time method at $25^{\circ}C$. The detection limit based on statistical $3S_{blank}$/m-criterion was 0.215 ${\mu}gL^{-1}$ for the fixed time method (7 min). All of the variables that affect the sensitivity at 523 nm were investigated, and the optimum conditions were established. The interference effect of various cations and anions on the Se (IV) determination was also studied. The selectivity of the selenium determination was greatly improved with the use of the strongly cation exchange resin such as Amberlite IR120 plus. The proposed kinetic method was validated statistically and through recovery studies in natural water samples. The RSDs for ten replicate measurements of 5, 15 and 25 ${\mu}gL^{-1}$ of Se(IV) and Se(VI) was changed between 2.1 - 4.85%. Analyses of a certified standard reference material (NIST SRM 1643e) for selenium using the fixed-time method showed that the proposed kinetic method has good accuracy. Se(IV), Se(VI) and total inorganic selenium in environmental water samples have been successfully determined by this method after selective reduction of Se(VI) to Se(IV).