• Title/Summary/Keyword: 3mm

Search Result 22,617, Processing Time 0.046 seconds

Egg Development and Morphology of Larva and Juvenile of the Chub Mackerel, Scomber japonicus (고등어(Scomber japonicus)의 난발생 및 자치어 형태발달)

  • Park, Chung-Kug;Yeon, In-Ho;Choi, Nak-Hyun;Heo, Seung-Joon;Han, Kyeong-Ho;Lee, Won-Kyo
    • Development and Reproduction
    • /
    • v.12 no.3
    • /
    • pp.207-213
    • /
    • 2008
  • In order to monitor the developmental features of embryos, larvae, and juveniles of chub mackerel, Scomber japonicus, the fertilized eggs were obtained by artificial insemination. The fertilized eggs were spherical in shape and floated separately. Their membrane and yolk having 1 oil globule were transparent. The transparent eggs, having one oil drop in the yolk, were $0.94{\sim}1.02\;mm$ (mean, $0.95{\pm}0.03\;mm$) in diameter. The fertilized eggs started hatching at 51 hrs after fertilization in $20{\pm}0.5^{\circ}C$ water. The total length of the hatched larvae was $2.52{\sim}3.0\;mm$ (mean, $2.75{\pm}0.04\;mm$). At hatching, the larva, with the mouth and anus not opened yet, had yolk sack, $28{\sim}31$ myomeres and eyes with melanophore. Yolk completely 2 days after hatching and the total length of post-larvae $3.12{\sim}3.63\;mm$ (mean, $3.39{\pm}0.05\;mm$). At the 18 days after hatching, the tip of tail became curved at the end and the stems for pectoral, dorsal, and caudal fins appeared. Juveniles, having all firm rays, was $44.12{\sim}58.72\;mm$ (mean $55.95{\pm}6.74\;mm$) in TL 25 days after hatching.

  • PDF

Automatic Feeding and Transplanting Mechanism for Plug Seedling Transplanter (플러그묘 자동이식기의 묘 자동공급 및 이식기구에 관한 연구)

  • 민영봉;문성동
    • Journal of Biosystems Engineering
    • /
    • v.23 no.3
    • /
    • pp.259-270
    • /
    • 1998
  • An automatic seedling transplanter, employed an innovative plug-seedling feeder was developed by improving the problems of conversational feeding and transplanting mechanisms. With conventional methods, missing and damage rates of seedling were high for long seedlings over 20cm and also breaking seed-bed was frequently observed. Thus, a pushout-bucket slide-hopper type trandsplanter was devised and tested. Test results of picking and transferring accuracies of the developed transplanter are as follows : A prototype transplanter performed with 1.5% of missing rate. The deviations of horizontal feed ranged from -0.3mm to 2.8mm and averaged 0.673mm for the 128-hoe test tray : and ranged from -lmm to +3mm and averaged 0.785mm for the 200-hole test tray. The deviations could decrease with precise manufacturing and lightening the mechanism. The maximum and deviations of vertical feed were -2.3mm and + 1mm, respectively, for the 128-hole test tray ; and were +3mm and +2.5mm, respectively, for the 200-hole test tray. The missing rate, seeding bruise rate and seed-bed damage rate were esitmate to be 1.3%, 0.4% and 3.5%, respectively, with the developed automatic transplanter.

  • PDF

Design and Fabrication of Dual Linear Polarization Antenna for 28 GHz Band (28 GHz 대역에서 동작하는 이중 선형편파 안테나의 설계 및 제작)

  • Yoon, Joong-Han
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.1
    • /
    • pp.13-22
    • /
    • 2022
  • In this paper, we propose single and array antenna with dual linear polarization characteristics for 28 GHz band. The proposed antenna is designed two microstirp feeding structure and Taconic TLY-5 substrate, which is thickness 0.5 mm, and the dielectric constant is 2.2. The size of single patch antenna is 3.4 mm×3.4 mm, and total size of single antenna is 15.11 mm×15.11 mm. Also, the size of array antenna is 3.15 mm×3.15 mm, and total size of array antenna is 21.5 mm×13.97 mm. From the fabrication and measurement results, for 1×2 array antenna, in case of vertical polarization, cross polarization ratios are obtained from 14.23 dB to 20.79 dB and in case of horizontal polarization, cross polarization ratios are obtained from 14.31 dB to 22.74 dB for input port 1. in case of vertical polarization, cross polarization ratios are obtained from 15.75 dB to 25.88 dB and in case of horizontal polarization, cross polarization ratios are obtained from 14.70 dB to 22.82 dB for input port 2.

Flow Signal Characteristics of Small Scale Electromagnetic Flowmeter in Low Conductivity Fluid Measurement (저전도율 유체 측정에서 소형 전자기유량계의 신호 특성)

  • Lim, Ki Won;Jung, Sung Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.9
    • /
    • pp.613-620
    • /
    • 2016
  • In order to scrutinize the fluid conductivity effects on the electromagnetic flowmeter(EMF) characteristics, a small scale EMF was designed and fabricated. The measuring tube has a $3mm{\times}4mm$ rectangular cross-section, 9 mm length, and a $2mm{\times}3mm$ plate electrode and a ${\Phi}1.5mm$ point electrode. The design parameters, such as the magnetizing frequency and the number of coil turns, and the diameter were optimized. The EMF was tested with a gravimetric calibrator and showed good linearity in the range of 0 to $1.17{\times}10^{-5}m^3/s$. The fluid conductivity was varied between 3 and $11{\mu}S/cm$, and the magnitude of the flow signal was proportional to the fluid conductivity and the wetted area of the electrode. The design information and the test results provide flow measurement techniques for very low flowrate.

Resonant Wireless Power Transfer System with High Efficiency using Metamaterial Cover (메타구조 기반의 고효율 공진형 무선전력전송 시스템)

  • Kim, Hyoungjun;Seo, Chulhun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.1
    • /
    • pp.47-51
    • /
    • 2014
  • In this paper, unit cell and arrayed cover for improving the transfer efficiency of resonant wireless power transfer system is proposed. We used the characteristic of zero refractive index for focusing a magnetic field between the transmitting resonator and receiving resonator. For zero refractive index, we designed the unit cell structure that have a negative value of effective permeability. The size of proposed unit cell based on metamaterial structure is $70mm{\times}70mm{\times}3.2mm$, operating frequency is 13.56 MHz. And, the size of arrayed cover is $400mm{\times}400mm{\times}3.2mm$, is consists of 2-layers. The transfer efficiency of the proposed wireless power transfer system are 94.8 %, 93.2 %, 91.4 %, 90.8 % at 100 mm, 200 mm, 300 mm and 400 mm (distance between transmitting and receiving resonator), respectively. And proposed WPT system has a transfer efficiency high than 90 % over the overall distances.

Second Harmonic Generation of Tisapphire Laser in $LiIO_3$, BBO Crystals ($LiIO_3$ 및 BBO 결정을 이용한 Ti:sapphire 레이저의 제2조화파 발생)

  • 오차환
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.2
    • /
    • pp.200-205
    • /
    • 1993
  • We generated the second harmonic of Ti:sapphire laser in LiI$O_3$ and BBO crystals. Two LiI$O_3$, crystals and a BBO crystal were used, and the lengths of LiI$O_3$ crystals were 5, 10 mm and that of BBO was 7 mm. We measured the conversion efficiencies of LiI$O_3$ and BBO in the wavelength range of 780-810 nm, and compared with the caculation of theory. The measured second harmonic conversion coefficients were (1.06${\pm}0.05){\times}10^4\;W^1$(10mm), (5.28${\pm}0.33){\times}10^5\;W^1$(5mm), and (2.96${\pm}0.05){\times}10^5\;W^1$(BBO, 7 mm) at the fundamental wavelength of 794 nm.

  • PDF

Multi-element Ultrasound Applicator for the Treatment of Cancer in Uterus and Cervix (자궁암 치료용 다채널 초음파 온열치료기)

  • Lee Rena
    • Progress in Medical Physics
    • /
    • v.16 no.1
    • /
    • pp.16-23
    • /
    • 2005
  • The objective of this study was to construct multi-element ultrasound applicators for the treatment of gynecologic cancer with high dose rate brachytherapy. For the treatment of uterus, piezo-ceramic crystal transducer (PZT -5A) with outer diameter of 4 mm, wall thickness of 1.3 mm, and length of 24.5 mm was selected. For the treatment of cervix or vagina, it should be possible to insert the applicator into the vagina. Thus, a cylindrical PZT -8 material with outer diameter of 24.5 mm, wall thickness of 1.3 mm, and length of 15.2 mm was selected. The operating frequencies determined by vector impedance measurement were 3.2 MHz for the PZT 5A cylinder (OD=4 mm) and 1.7 MHz for the PZT -8 cylinder (OD: 24.5 mm). The ratios of generated acoustic output power to applied electric power were 33% and 61% for the tandem type crystal and the cylinder type crystal, respectively. The radiated acoustic pressure fields from both transducers were calculated using a Matlab code and measured in water using hydrophone. There was good agreement between measured and calculated acoustic pressure field distribution. For a tandem type transducer, the calculated acoustic pressure field decreased from 0.023 MPa at 10 mm to 0.010 Mpa at 30 mm, the reduction of 57%. For the cylinder type transducer which will be used for the treatment of vagina showed 78% reduction at 15 mm and 66% at 25 mm as compared to values at 5 mm from the surface. Based on the characteristics of the transducers, this study demonstrated the possibility of using the crystals as a heating source. Finally, a 3-element and 4-element prototype applicators were constructed. The 3-element applicator is 75 mm long and 4 mm thick and will be used for the treatment of uterus. The 4-element applicator is 61 mm long and 24.5 mm thick and will be used for the treatment of vagina. Using these applicators, it is possible to generate enough power to increase temperature to therapeutic level.

  • PDF

Host ranges and Temperature effects on the development of Liriomyza trifolii Burgess(Diptera: Agromyzidae) (아메리카잎굴파리의 기주범위 및 충태별 발육에 미치는 온도의 영향)

  • 박종대
    • Korean journal of applied entomology
    • /
    • v.35 no.4
    • /
    • pp.302-308
    • /
    • 1996
  • This study was conducted to investigate occurrence and host ranges of Liriomyza trifolii Burgess, American serpentineleafminer, in Chonnam province. Also, temperature effects on the development along with morphologicalcharacteristics in each instar of L. trifolii were studied. L. hifolii was observed from 22 species inthe 7 families. Gerbera, chrysanthemum and tomato were the most damaged host plants. Egg was transparentwhite with lengthlwidth of 0.27 mm10.25 mm while matured larva was yellow with that of 2.03 mm10.80 mmrevealing serpentine gallary under leaf cuticle. Pupa was light brown with that of 1.75 mrn10.74 mm and pupatedon the soil and/or leaf surface. Lengthlwing span of adult was 1.78 mm/3.43 mm. Number of oviposition/sucking punches by L. bifolii adult was 26.1% and 13.3% in tomato and gerbera leaves respectively. Feedingactivity of larval stage was highest at 2OoC. Developmental~threshold (DT) and effective accumulative temperatures(ET) on gerbera leaves were 11.2"C, 33.9DD in egg, 10.3'C, 38.6DD in larva, 10.7"C, 152.3DD inpupa, and 10.8"C, 222.8DD from egg to pupa. On tomato leaves, DT and ET were 13.6"C, 20.2DD in egg, 9.3"C, 43.7DD in larva, ll.O$^{\circ}$C, 114.3DD in pupa, and 11.6"C 178.2DD from egg to pupaDD in pupa, and 11.6"C 178.2DD from egg to pupa pupa.

  • PDF

Ecological Characteristics of Phoxinus phoxinus (Cyprinidae) at the Spring Water in Eocheon Stream, Korea (어천 용천수에 서식하는 연준모치 Phoxinus phoxinus (Cyprinidae)의 생태 특성)

  • Byeon, Hwa-Keun
    • Korean Journal of Environment and Ecology
    • /
    • v.33 no.3
    • /
    • pp.256-265
    • /
    • 2019
  • We investigated the ecological characteristics of Phoxinus phoxinus in the spring water in Eocheon stream from January to December 2016. The water temperature was $9.7{\sim}14.3^{\circ}C$ and remained below $15^{\circ}C$ throughout the year. The fishes cohabiting with minnow were Rhynchocypris kumgangensis (70.14%), Cottus koreanus (13.63%), Rhynchocypris oxycephalus (3.16%), Oncorhynchus mykiss (0.97%), Zacco koreanus (0.49%), and Iksookimia koreensis (0.24%). The sex ratio of female to male was 1:0.86. The frequency analysis of total length indicated that the fishes with the total length of 30 - 50 mm were one year old, those of 50 - 65 mm were two years old, those of 65 - 75 mm were three years old, and those of 75 mm or more were four years old. The sexually mature fishes were 50 mm or longer for female and 60 mm or longer for male. The spawning season was from April to July, and the water temperature was $12.3-14.3^{\circ}C$ during the period. The prosperous spawning season was from June to July, and the water temperature was $13.8-4.3^{\circ}C$ during the period. The average number of eggs in the ovaries was 508 per matured female, and the matured eggs were yellowish and spherical with a mean diameter of $1.58{\pm}0.13mm$. The length-weight correlation of P. phoxinus was $BW=0.000007TL^{3.09}$ with the constant a as 0.000007 and the parameter b as 3.09. The condition factor (K) was 0.99 (0.76 - 1.32) in average.

Evaluation of VMAT Dose Accuracy According to Couch Rotation in Stereotactic Radiation Surgery of Metastatic Brain Cancer (전 이성 뇌 암의 정위 방사선수술에서 Couch 회전에 따른 VMAT의 선량 정확성 평가)

  • Na, Gwui Geum;Park, Byoung Suk;Cha, Woo Jung;Park, Yong Chul
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.117-125
    • /
    • 2021
  • Purpose: To purpose of this study is to find the correlation of the Set-up error according to the couch rotation and suggest additional margin setting for the GTV. Target and Method: Each scenario treatment plan was created by making the frequency of non-coplanar beams different among all beams. The set-up error value was measured by using the Exact System and the dose accuracy was evaluated by creating a re-treatment plan. Results: When the couch was rotated by 30°, 45°, 60°, and 90°, the mean of the X-axis values was measured to be 0.29 mm, 0.26 mm, 0.51 mm, and 0.08 mm, respectively. The mean of the Y-axis values was measured to be 0.75 mm, 0.5mm, 0.35 mm, and 0.29 mm, respectively. The mean of the Z-axis values was measured to be 0.5 mm, 0.28 mm, 0.22 mm, and 0.1 mm, respectively. There were dose reductions of 0.1%, 3.1%, 1.9% in D99 for 1-NC VMAT, 2-NC VMAT, and 3-NC VMAT, respectively. Conclusion: When treating with 50% or more of non-coplanar beams among total beams, image verification is required. And it is considered to make the treatment plan by adding a 1.5 mm margin to the GTV.