• Title/Summary/Keyword: 3d Scan

Search Result 879, Processing Time 0.043 seconds

Development of Bodice Dress Forms by Body Types for Women in Thirties Applying 3D Body Scan Data (3D 인체 스캔 데이터를 활용한 체형별 인대모형 개발에 관한 연구)

  • Suh, Dong-Ae;Oh, Seol-Yong
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.9
    • /
    • pp.136-145
    • /
    • 2012
  • This research proposes a pattern making method for women's bodice by the characters of body types and develops bodice dress forms on their body shapes applying 3D body scan data. 515 women's body scan data was collected and analyzed factor and cluster analysis. Three body types were characterized in normal, obese, and slim group. In each group, 10 subjects were selected. 20 parts in 3D anthropometric data were measured using Autocad program. The amount of waist dart was calculated and three types of basic bodice pattern were developed using the calculated darts data. The amount and the position of front dart and side dart were different at obese group in comparison of normal and thin group. The three types of basic bodice model were made by the basic bodice pattern, and each model was scanned by 3D scanner to make 3D bodice dress forms. Three types of bodice dress forms were rendered using 3D max program. Bodice dress forms had the dart lines and were useful to draft patterns to fit their body shape.

Upper Body Surface Change Analysis using 3-D Body Scanner (3차원 인체 측정기를 이용한 체표변화 분석)

  • Lee Jeongran;Ashdoon Susan P.
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.29 no.12 s.148
    • /
    • pp.1595-1607
    • /
    • 2005
  • Three-dimensional(3-D) body scanners used to capture anthropometric measurements are now becoming a common research tool far apparel. This study had two goals, to test the accuracy and reliability of 3-D measurements of dynamic postures, and !o analyze the change in upper body surface measurements between the standard anthropometric position and various dynamic positions. A comparison of body surface measurements using two different measuring methods, 3-D scan measurements using virtual tools on the computer screen and traditional manual measurements for a standard anthropometric posture and for a posture with shoulder flexion were $-2\~20mm$. Girth items showed some disagreement of values between the two methods. None of the measurements were significantly different except f3r the neckbase girth for any of the measuring methods or postures. Scan measurements of the upper body items showed significant linear surface change in the dynamic postures. Shoulder length, interscye front and back, and biacromion length were the items most affected in the dynamic postures. Changes of linear body surface were very similar for the two measuring methods within the same posture. The repeatability of data taken from the 3-D scans using virtual tools showed satisfactory results. Three times repeated scan measurements f3r the scapula protraction and scapula elevation posture were proven to be statistically the same for all measurement items. Measurements from automatic measuring software that measured the 3-D scan with no manual intervention were compared with the measurements using virtual tools. Many measurements from the automatic program were larger and showed quite different values.

Comparison of the accuracy of implant digital impression coping (임플란트 디지털 인상용 코핑의 정확성 비교)

  • Ahn, Gyo-Zin;Lee, Joon-Seok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.1
    • /
    • pp.29-40
    • /
    • 2020
  • Purpose: The purpose of this study was to compare the accuracy of impression taking method using the encoded healing abutment, scan body and pick-up impression coping with different implant angulations. Materials and Methods: Master model was fabricated by 3D printer and three implants were placed into the model with 0°, 10° and 20° mesial angulation. The abutments were secured to each implants and master model was scanned to make a reference model. Group P model was fabricated using pick-up impression copings and model was scanned after securing the abutments. Encoded healing abutment (Group E) and scan body (Group S) were secured on the master model and digital impression was taken using intraoral scanner 15 times each. Each STL files of test groups were superimposed with reference model using best fit alignment and root mean square (RMS) value was analyzed. Results: The RMS values were lowest in Group P, followed by Group S and Group E. Group P showed significant difference with Group S and E (P < 0.05) while there was no significant difference between Group S and E. Correlation between implant angulation and RMS value was significant in Group E (P < 0.05). Conclusion: The pick-up impression coping method showed higher accuracy and there was no significant difference in accuracy between the healing abutment and the scan body. The clinical use of the encoded healing abutment is possible, but it should be used with caution in the case of angulated implant.

A Study of Shirts' Patternmaking Based on 3D Body Surface Changes in Golf Swing Postures (골프 스윙 자세의 체표면 변화 특성을 반영한 셔츠 패턴 설계 연구)

  • Oh, Seol-Young;Chun, Jong-Suk
    • The Research Journal of the Costume Culture
    • /
    • v.19 no.5
    • /
    • pp.1049-1060
    • /
    • 2011
  • The purpose of this study was to develop a shirt pattern that enhances the functionality of golf swing motions. The pattern was made with 3D body surface shape data that changed according to dynamic golf postures. The data were collected from the golf swing motions. The 3D body surface data in golf swing postures piled up on the 3D surface data in a static posture. The results showed that the surface shape data changed more in the address, back swing, and finish postures than the other swing postures. The experimental pattern was developed with 3D surface scan data in those three golf swing motions. The pattern had raglan sleeves and the front-bodied piece was divided into two pieces with a princess line, which comes from armscye line of the address posture. The back bodice piece was divided into three pieces with a yoke line and a back princess line. The yoke line was made by back shoulder shape in the back swing posture. The level of comfort of the experimental garment and commercial golf shirts was evaluated by 38 women golfers. The experimental garment pattern was evaluated to be more comfortable in golf swing postures than commercial golf shirts.

A Comparative Analysis of the Difference between 3D Body Scan Measurements and Physical Measurements by Gender -5th Size Korea Adult Data- (3차원 스캔측정치와 직접치수간 차이의 성별 비교 -제5차 Size Korea 성인데이터를 대상으로-)

  • Han, Hyun-Sook;Nam, Yun-Ja
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.33 no.8
    • /
    • pp.1190-1202
    • /
    • 2009
  • A 3D body scan measurement (SM) is used as an alternative to physical measurements (PM) as the information for designing industrial products. This study compared the mean difference (MD) between SM and PM by gender and analyzed the causes of the difference. The data used in this study were the scan measurements and physical measurements of adults aged twenty to seventy years old of the fifth Size Korea survey. The results of this study are as follows: 1. The comparison of MD between men and women for all subjects: The measurement of the significant differences between men and women were height, neck base girth, chest girth, under-bust girth, waist girth, armscye girth, back length, and foot length. The causes of difference are the difference of body shape. 2. The comparison of MD between men and women by BMI groups: Many measurements had significant differences between men and women at normal weight and overweight but underweight. Some measurements had significant differences only at a specific BMI group because the body shape difference between men and women is revealed clearly in the group. The comparison of MD between men and women by age groups: The measurements that show significant difference at more than four age groups were neck girth, chest girth, under-bust girth, waist girth, armscye girth, and foot length. The height and abdomen girth had a significant difference in the age range of 20's and 30's. There were measurements that increase MD with an increase in age; under-bust girth and lateral shoulder length for women and lateral shoulder length for men. This comparison of MD between men and women provide the correct guidelines for the use of SM.

Correction of Beam Direction Error caused by Frequency Scan Effect in Active Phased Array Antenna for Satellite Communications (위성통신 능동 위상배열 안테나에서 주파수 스캔 효과로 발생하는 빔 지향 오차의 보상)

  • 전순익;오승엽
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.4
    • /
    • pp.413-420
    • /
    • 2003
  • In this paper, the correction method of antenna beam direction errors is introduced which caused by frequency scan effect in active Phased may antenna for satellite communications. The antenna makes the beam directional error from frequency scan effect when it has dual beam may structure with asymmetrical series connection, their frequencies are different and for from each other, their 3dB beamwidth is narrow, and scan range is wide. By proposed equations, estimated beam direction error angles can be calculated and active phase shifter control values also can be calculated to compensate them. In this paper, the active phased array antenna system was fabricated to measure beam direction errors both before and after correction, which has dual beam from 32${\times}$4 main level array and 4${\times}$2 second level array, frequency deviation 500 MHz max.(6.7 %) at 7.25 GHz∼7.75 GHz ranges, 0$^{\circ}$${\pm}$35$^{\circ}$nm ranges, and 35.6 dBi gain with 2.2$^{\circ}$3 dB beam width. Its beam direction error by frequency san effect which was 2.5$^{\circ}$max., was reduced to 0.2$^{\circ}$max. after correction. This was 7 dB improvement of signal loss. The active phased array antenna can accurately track the target satellite for communications by this proposed correction method.

A Measure of Landscape Planning and Design Application through 3D Scan Analysis (3D 스캔 분석을 통한 전통조경 계획 및 설계 활용방안)

  • Shin, Hyun-Sil
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.36 no.4
    • /
    • pp.105-112
    • /
    • 2018
  • This study aims to apply 3D scanning technology to the field of landscape planning design. Through this, 3D scans were conducted on Soswaewon Garden and Seongrakwon Gardens to find directions for traditional landscape planning and designs. The results as follows. First, the actual measurement of the traditional garden through a 3D scan confirmed that a precise three-dimensional modeling of ${\pm}3-5mm$ error was constructed through the merging of coordinate values based on point data acquired at each observation point and postprocessing. Second, as a result of the 3D survey, the Soswaewon Garden obtained survey data on Jewoldang House, Gwangpunggak Pavilion, the surrounding wall, stone axis, and Aeyangdan wall, while the Seongnakwon Garden obtained survey data on the topography, rocks and waterways around the Yeongbyeokji pond area. The above data have the advantage of being able to monitor the changing appearance of the garden. Third, spatial information developed through 3D scans could be developed with a three-dimensional drawing preparation and inspection tool that included precise real-world data, and this process ensured the economic feasibility of time and manpower in the actual survey and investigation of landscaping space. In addition, modelling with a three-dimensional 1:1 scale is expected to be highly efficient in that reliable spatial data can be maintained and reprocessed to a specific size depending on the size of the design. In addition, from a long-term perspective, the deployment of 3D scan data is easy to predict and simulate changes in traditional landscaping space over time.

A study on the core technologies for industrial type digital 3D SFF system

  • Kim, Dong-Soo;An, Young-Jin;Kim, Sung-Jon;Choi, Byung-Oh;Lim, Hyun-Eui
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2170-2174
    • /
    • 2005
  • Selective Laser Sintering (SLS) is a useful rapid prototyping technique for the manufacture of three dimensional (3D) solid objects directly from a scanning data. A new approach called a Selective Multi-Laser Sintering (SMLS) system has been developed at Korea Institute Machinery & Materials (KIMM) as an industrial type SFFS. This SMLS machine is built with a frame, heaters, nitrogen supply part, laser system. This system uses the dual laser and 3D scanner made in $Solutionix^{TM}$ to improve the precision and speed for large objects. The three-dimensional solid objects are made of polyamide powder. The investigation on each part of SMLS system is performed to determine the proper theirs design and the effect of experimental parameters on making the 3D objects. The temperature of the system has a great influence on sintering the polymer. Because the stability of the powder temperature prevents the deformation of each layer, the controls of the temperature in both the system and the powders are very important during the process. Therefore, we simulated the temperature distribution of build room using the temperature analysis with ANSYS program. Selected radiant heater is used to raise temperature of powder to melting point temperature. The laser parameters such as scan spacing, scan speed, laser power and laser delay time affect the production the 3D objects too. The combination of the slow scan speed and the high laser power shows the good results without the layer curling. The work is under way to evaluate the effect of experimental parameters on process and to produce the various objects. We are going to experiment continuously to improve the size accuracy and surface roughness.

  • PDF

Real-time Tooth Region Detection in Intraoral Scanner Images with Deep Learning (딥러닝을 이용한 구강 스캐너 이미지 내 치아 영역 실시간 검출)

  • Na-Yun, Park;Ji-Hoon Kim;Tae-Min Kim;Kyeong-Jin Song;Yu-Jin Byun;Min-Ju Kang․;Kyungkoo Jun;Jae-Gon Kim
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.46 no.3
    • /
    • pp.1-6
    • /
    • 2023
  • In the realm of dental prosthesis fabrication, obtaining accurate impressions has historically been a challenging and inefficient process, often hindered by hygiene concerns and patient discomfort. Addressing these limitations, Company D recently introduced a cutting-edge solution by harnessing the potential of intraoral scan images to create 3D dental models. However, the complexity of these scan images, encompassing not only teeth and gums but also the palate, tongue, and other structures, posed a new set of challenges. In response, we propose a sophisticated real-time image segmentation algorithm that selectively extracts pertinent data, specifically focusing on teeth and gums, from oral scan images obtained through Company D's oral scanner for 3D model generation. A key challenge we tackled was the detection of the intricate molar regions, common in dental imaging, which we effectively addressed through intelligent data augmentation for enhanced training. By placing significant emphasis on both accuracy and speed, critical factors for real-time intraoral scanning, our proposed algorithm demonstrated exceptional performance, boasting an impressive accuracy rate of 0.91 and an unrivaled FPS of 92.4. Compared to existing algorithms, our solution exhibited superior outcomes when integrated into Company D's oral scanner. This algorithm is scheduled for deployment and commercialization within Company D's intraoral scanner.

Evaluation of Skin Dose and Image Quality on Cone Beam Computed Tomography (콘빔CT 촬영 시 mAs의 변화에 따른 피부선량과 영상 품질에 관한 평가)

  • Ahn, Jong-Ho;Hong, Chae-Seon;Kim, Jin-Man;Jang, Jun-Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose: Cone-beam CT using linear accelerator attached to on-board imager is a image guided therapy equipment. Because it is to check the patient's set-up error, correction, organ and target movement. but imaging dose should be cause of the secondary cancer when taking a image. The aim of this study is investigation of appropriate cone beam CT scan mode to compare and estimate the image quality and skin dose. Materials and Methods: Measurement by Thermoluminescence dosimeter (TLD-100, Harshaw) with using the Rando phantom are placed on each eight sites in seperately H&N, thoracic, abdominal section. each 4 methods of scan modes of are measured the for skin dose in three time. Subsequently, obtained average value. Following image quality QA protocol of equipment manufacturers using the catphan 504 phantom, image quality of each scan mode is compared and analyzed. Results: The results of the measured skin dose are described in here. The skin dose of Head & Neck are measured mode A: 8.96 cGy, mode B: 4.59 cGy, mode C: 3.46 cGy mode D: 1.76 cGy and thoracic mode A: 9.42 cGy, mode B: 4.58 cGy, mode C: 3.65 cGy, mode D: 1.85 cGy, and abdominal mode A: 9.97 cGy, mode B: 5.12 cGy, mode C: 4.03 cGy, mode D: 2.21 cGy. Approximately, dose of mode B are reduced 50%, mode C are reduced 60%, mode D are reduced 80% a point of reference dose of mode A. the results of analyzed HU reproducibility, low contrast resolution, spatial resolution (high contrast resolution), HU uniformity in evaluation item of image quality are within the tolerance value by recommended equipment manufacturer in all scan mode. Conclusion: Maintaining the image quality as well as reducing the image dose are very important in cone beam CT. In the result of this study, we are considered when to take mode A when interested in soft tissue. And we are considered to take mode D when interested in bone scan and we are considered to take mode B, C when standard scan. Increasing secondary cancer risk due to cone beam CT scan should be reduced by low mAs technique.

  • PDF