• Title/Summary/Keyword: 3V

Search Result 24,106, Processing Time 0.052 seconds

Study on The lonzation Potential, Electron Affinity and Electrochemical Property of PBO and PVK using Cyclic Voltammetry and Constant Current Potentiometry (순환전압전류법과 일정전류전위차법을 이용한 PBD와 PVK의 이온화에너지, 전자친화도 및 전기화학적 특성에 관한 연구)

  • 형경우;최돈수
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.12S
    • /
    • pp.1273-1277
    • /
    • 2003
  • The effects of molecular structure on the redox properties are explored by the cyclic voltammetry, constant current potentiometry and spectroscopy using the thin films of organic electroluminescence materials of Poly(N-vinylcarbazole); PVK and 2- (4'-tert-butylphenyl) -5-(4"-bisphenyl) -1,3,4-oxadiazole; PBD. The UV/visible absorption maxima and band gap (E$\_$g/) show at 310nm (4.00eV) and 368nm (3.37eV) for FBD, 344nm (3.60eV) and 356nm (3.48eV) for PVK, respectively. The measured electrochemical ionization potential (IP) and electron affinity (EA) of these materials we 5.87 and 2.82eV for PBD, 5.80 and 3.17eV for PVK, respectively. The electrical band gaps are 3.05eV for PBD and 2.78eV for PVK, respectively. The electrical hole gap and electron gap with respect to the first rising potentials and the inflection potentials are obtained to be 0.39V and 0.41V for PBD, 0.25V and 0.28V for FVK, respectively.

Structural characterization of $LaTi_{0.8}V_{0.2}O_3$ compounds by transmission electron microscoy (투과전자현미경에 의한 $LaTi_{0.8}V_{0.2}O_3$ 화합물의 결정구조 분석)

  • 김좌연;윤의중;박경순;심규환;류선윤;김유혁
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.8 no.4
    • /
    • pp.567-572
    • /
    • 1998
  • The crystalline structure of $LaTi_{0.8}V_{0.2}O_3$ solid solutions, prepared by arc-melting palletized mixtures of predried $La_2O_3,\;V_2O_3,\;TiO_2$, and Ti, was investigated by transmission electron microscopy and computer image simulation. Computer image simulations were performed by the multislice method for a wide range of sample thickness and defocusing value. The structure of $LaTi_{0.8}V_{0.2}O_3$ was determined as a $GdFeO_3$-type orthorhombic $(a\approx5.58{\AA},\;b\approx7.89{\AA},\;and\;c\approx5.58{\AA})$ with a space group $P_{nma-}$. No evidence of ordering of Ti and V atoms in $SaTi_{0.8}V_{0.2}O_3$ was found.

  • PDF

Differential Expression of Four $Ca_v$3.1 Splice Variants in the Repeat III-IV Loop

  • Lee, Sang-Soo;Park, You-Mi;Kang, Ho-Won;Bang, Hyo-Weon;Jeong, Seong-Woo;Lee, Jung-Ha
    • Animal cells and systems
    • /
    • v.12 no.3
    • /
    • pp.137-141
    • /
    • 2008
  • Molecular cloning revealed the three isoforms($Ca_v3.1,\;Ca_v3.2,\;and\;Ca_v3.3$) of the T-type calcium channel subfamily. Expression studies exhibited their distinctive electrophysiological and pharmacological properties, accounting for diverse properties of T-type calcium channel currents previously characterized from isolated cells. However, electrophysiological properties of ion channels have shown to be more diversified by their splice variants. We here searched splice variants of rat $Ca_v3.1$ T-type channel by reverse-transcription-polymerase chain reaction(RT-PCR) to further explore diversity of $Ca_v3.1$. Interestingly, analyses of cloned RT-PCR products displayed that there were at least four splicing variants of rat $Ca_v3.1$ in the loop connecting repeats III and IV. Southern blot analyses indicated that the predominantly detected variant in brain was $Ca_v3.1a$(492 bp), which were rarely detected in most of peripheral tissues. Other two variants($Ca_v3.1c$, 546 bp; $Ca_v3.1d$, 525 bp) were detected in most of the tissues examined. The smallest isoform($Ca_v3.1b$, 471 bp) was rarely detected all the tissues. Electrophysiological characterization of the splicing variants indicated that the splice variants differ in inactivation kinetics and the voltage dependence of activation and inactivation as well.

Characteristics of Disc-Type V2O5 Catalyst Impregnated Ceramic Filters for NOx Removal (질소산화물 제거를 위한 디스크형 바나디아 촉매담지 세라믹필터의 특성)

  • 홍민선;문수호;이재춘;이동섭
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.4
    • /
    • pp.451-463
    • /
    • 2004
  • The performance of disk-type catalytic filters impregnated by TiO$_2$ or TiO$_2$-3Al$_2$O$_3$ㆍ 2SiO$_2$ supports and V$_2$O$_{5}$ catalyst was evaluated for selective catalytic reduction (SCR) of NO with ammonia as a reductant. XRD, FT -IR, BET and SEM were used to characterize the catalytic filters prepared in this work. Optimal V$_2$O$_{5}$ loading and reaction temperature for V$_2$O$_{5}$/TiO$_2$ catalytic filters were 3-6 wt.% and 350-40$0^{\circ}C$ at GHSV 14,300 $hr^{-1}$ in the presence of oxygen, respectively. With increasing the V$_2$O$_{5}$ loading from 0.5 to 6 wt%, NO conversion increased from 24 to 96% at 40$0^{\circ}C$ and 14.300$hr^{-1}$, and maintained at 80% over in the V$_2$O$_{5}$ loading range of 3-6 wt.% and then dropped at V$_2$O$_{5}$ loading of 7wt.% over. In comparing V$_2$O$_{5}$/ TiO$_2$ and V$_2$O$_{5}$/ TiO$_2$-3Al$_2$O$_3$ㆍ2SiO$_2$ catalytic fillers, which have same 3wt.% V$_2$O$_{5}$ loading, the V$_2$O$_{5}$/ TiO$_2$-3A1$_2$O$_3$ㆍ2SiO$_2$ catalytic filter showed higher activity than V$_2$O$_{5}$/ TiO$_2$ catalytic filter, but higher differential pressure drops owing to its low air permeability. low air permeability.

Electrochemical properties of $Li_2O-P_2O_5-V_2O_5$ Glass-ceramics by Addition of $Bi_2O_3$ ($Bi_2O_3$첨가에 따른 $Li_2O-P_2O_5-V_2O_5$ 결정화유리의 전기화학적 특성변화)

  • Son, Muong-Mo;Gu, Hal-Bon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.797-800
    • /
    • 2002
  • Instead of a solution process producing amorphous $LiV_3O_8$ form, we prepared Lithium vanadate glass by melting $Li_2O-P_2O_5-V_2O_5$ and $Li_2O-P_2O_5-Bi_2O_3-V_2O_5$ composition in pt. crucible and by quenching on the copper plate. From the crystallization of $Li_2O-P_2O_5-V_2O_5$ and $Li_2O-P_2O_5-Bi_2O_3-V_2O_5$, we could abtain glass-ceramics having crystal phase, LiV3O8 from glass matrix. The material heat-treated at lower-temperature, $250^{\circ}C$ had less crystalline and lower capacity, But the material heat-treadted at higher-temperature, $330^{\circ}C$ had higher capacity and $Li_2O-P_2O_5-V_2O_5$ glass-ceramics had higher capacity than $Li_2O-P_2O_5-Bi_2O_3-V_2O_5$ glass-ceramics.

  • PDF

Effects of Different Ventilation Systems on Rearing Growing-finisher and Indoor Environment in a High Rise Hog Building (고상식 돈사내에서 환기시스템별 환경조사 및 육성비육돈 사육 효과)

  • Yoo, Y.H.;Jeong, J.W.;Park, K.H.;Song, J.I.;Ko, Y.G.;Kim, S.W.;Lee, I.B.
    • Journal of Animal Environmental Science
    • /
    • v.16 no.3
    • /
    • pp.193-204
    • /
    • 2010
  • The goal of this study was to develop a high-rise hog building(HRHB) for growing-fattening stages. HRHB was two story building and was suitable for specific environment in Korea. Manure was treated in a first floor and pigs were raised on the slatted second floor. Three ventilation systems - 1) duct inlet to wall exhaust system(V1), 2) eave inlet to wall exhaust system(V2), and 3) ceiling inlet to wall exhaust system(V3) - were used. This experiment was conducted during winter and from summer to fall. Air temperature, air speed, ammonia, hydrogen sulfide in HRHB, and swine growth rate were measured. During winter, air temperature in V1 system tended to be slightly high without any effect of outside air temperature. Maximum temperature from summer to fall was between 33.4 and $33.8^{\circ}C$ and there was no significant difference among systems. Continuously measured daily temperature was lower in V2 system than other systems and the fluctuation of air temperature was high. Air speed in V1 and V2 systems were similar (0.02~0.21 m/s), and was 0.04~0.15 m/s in V3 during winter. From summer to fall, air speed in V1, V2, and V3 systems were 0.10~0.41 m/s, 0.10~0.83 m/s, and 0.11~0.26 m/s, respectively. V2 system showed bigger fluctuation of air speed than other systems. During winter, the highest concentrations of ammonia in V1, V2, and V3 systems were 7.0, 3.5, and 8.7 ppm, respectively. Hydrogen sulfide was not detected. The highest concentrations of ammonia from summer to winter in V1, V2, and V3 systems were 6.1, 2.8, and 5.6 ppm, respectively. Swine growth showed no statistical significance among systems. However, daily weight gain was approximately 4% higher in V1 and V3 than in V2. Feed intake/daily weight gain was approximately 4% higher in V1 than other systems. From summer to fall, daily weight gain in V1 and V3 tended to approximately 3% higher than other systems, and feed intake/daily weight gain was approximately 2% higher in V1 than other systems. Hence, V2 system for the ventilation system of HRHB should not be utilized.

[2,3]-FACTORS IN A 3-CONNECTED INFINITE PLANAR GRAPH

  • Jung, Hwan-Ok
    • Journal of applied mathematics & informatics
    • /
    • v.10 no.1_2
    • /
    • pp.27-40
    • /
    • 2002
  • For two integers m, n with m $\leq$ n, an [m,n]-factor F in a graph G is a spanning subgraph of G with m $\leq$ d$\_$F/(v) $\leq$ n for all v ∈ V(F). In 1996, H. Enomoto et al. proved that every 3-connected Planar graph G with d$\_$G/(v) $\geq$ 4 for all v ∈ V(G) contains a [2,3]-factor. In this paper. we extend their result to all 3-connected locally finite infinite planar graphs containing no unbounded faces.

TTA 시험$\cdot$인증서비스 - 소프트웨어 분야 -

  • 김혜경
    • TTA Journal
    • /
    • s.86
    • /
    • pp.89-93
    • /
    • 2003
  • TTA(한국정보통신기술협회)는 2003년 2월 28일, 품질인증 제품으로 ㈜하나디에스디의''라이프에듀빌더 v 1.0'', ㈜연성정보기술의''이메일플러스 v 3.0'', ㈜포스정보의''책꽂이KDC v 3.1'', ㈜켈코인의''챌린저 웹진 웹스쿨 v 3.0'' 등 4개의 제품에 대하여 Good Software 마크를 발급하였다. 그리고 2003년 3월 10일에 VeriTest-TTA 인증제품으로 (주)스페이스 인터내셔널의''CD Tower v 3.1''은 VeriTest-TTA Good Quality, Optimized Performance & Internationalized 마크를, ㈜포스데이터의''BizBinder v 1.0''은 VeriTest-TTA Good Quality & Optimized Performance 인증마크를 발급하였다. 본 고에서는 상위의 인증 획득한 제품에 대하여 소개하고자 한다.

  • PDF

A Study to Establish the Core Process of ITIL v3 Using ANP (ANP 모형을 이용한 ITIL v3 핵심 프로세스 도출 연구)

  • Huh, Sang Moo;Kim, Woo Je
    • Journal of Information Technology Services
    • /
    • v.16 no.3
    • /
    • pp.83-101
    • /
    • 2017
  • IT services are provided by many public institutions and companies in order to satisfy various needs of customers. As the modern IT systems become larger and more complex, it becomes more difficult for IT organizations to provide IT services. So, the IT organizations have applied or are planning to apply ITIL (Information Technology Infrastructure Library) in order to provide IT services systematically. The ITIL v3 was revised on July 2011 and have 5 categories, 37 processes, and 113 sub-processes. Therefore, it is known that it is very difficult to satisfy all processes of ITIL v3. If we can concentrate on the core processes of ITIL v3, we will be able to provide IT services more efficiently. The processes of ITIL v3 are defined as some processes influences other processes. Therefore, the core processes can be established using related techniques. We searched for previous research and related information, but we could not find any related research. In this study, we had applied the ANP (Analytic Network Process) techniques to find the core processes of ITIL v3. We expect that IT services will be provided more efficiently because we can be concentrate on the core processes of ITIL v3, which are the results of this study.