• Title/Summary/Keyword: 3D-offset

Search Result 449, Processing Time 0.025 seconds

임플랜트 상부구조의 재료가 반복하중 후 나사풀림에 미치는 영향 (AN INFLUENCE OF ABUTMENT MATERIALS ON A SCREW-LOOSENING AFTER CYCLIC LOADING)

  • 이태식;한중석;양재호;이재봉;김성훈
    • 대한치과보철학회지
    • /
    • 제45권2호
    • /
    • pp.240-249
    • /
    • 2007
  • Statement of problem: A phenomenon of screw-loosening in implant abutment is frequently occurred in a single and multiple implant restoration. Purpose: This study was performed to evaluate an effect of abutment material on screw-loosening before and after a cyclic loading. In a single-tooth implant, different materials of abutment, Type III Gold alloy and Zirconium composite$(ZrO_2/Al_2O_3)$ were used. Material and method: The Gold alloy(Type III) and Zirconium composite$(ZrO_2/Al_2O_3)$ were used to make a superstructure of implant, the one of types of UCLA, Each group was constituted of 5 sample with a 30-degree offset angulated loading platform. The external hexagonal fixture was rigidly hel d in a special holding zig to ensure solid fixation without rotation during the tightening and a cyclic loading. A Titanium-alloy screw was used to connect and controlled to be tighten in 20Ncm torque by a digital torque gauge. A 20 times of consecutive closing/opening cycle were performed to evaluate the immediate torque loss. In 5 sample of each material group, an initial opening torque was recorded during 3 closing/opening cycle, then 2Hz, 200N, 1,000,000 cyclic loadings were performed, then a opening torque was evaluated. Result & Conclusion: 1. In this limited study, titanium alloy screw tightened in 20Ncm, a cold-welding phenomen on was not observed during the 20 times of closing/opening cycle(p=0.11, p=0.18). 2. In titanium alloy abutment screw, repeated opening and closing of the screw caused to progressive decrease of opening torque(p=0.014). 3. The difference in preload of screw between gold alloy abutment and ceramic$(ZrO_2/Al_2O_3)$ abutment was not significant(p=0.78). 4. The difference in torque loss of screw between gold alloy abutment and ceramic$(ZrO_2/Al_2O_3)$ abutment was not significant after 2Hz,200N, 1,000,000 cyclic loading(p=0.92). 5. In titanium alloy abutment screw tightened by 20Ncm, the screw loosening was not significant on each group after 2Hz, 200Ncm, 1,000,000 cyclic loading(p=0.59).

혼합 우좌향 전송 선로 기반의 새로운 고조파 조절 회로를 이용한 저위상 잡음 전압 제어 발진기 (Low Phase Noise VCO Using Novel Harmonic Control Circuit Based on Composite Right/Left-Handed Transmission Line)

  • 최재원;서철헌
    • 대한전자공학회논문지TC
    • /
    • 제47권1호
    • /
    • pp.84-90
    • /
    • 2010
  • 본 논문에서는 주파수 조절 범위의 감소 없이 위상 잡음을 줄이고 회로 크기를 최소화하기 위하여 혼합 우좌향 전송 선로 기반의 고조파 조절 회로를 이용한 새로운 전압 제어 발진기를 제안하였다. 위상 잡음은 2차와 3차 고조파에서 동시에 단락임피던스를 갖는 새로운 고조파 조절 회로에 의해 줄어들었다. 제안된 고조파 조절 회로는 혼합 우좌향 전송 선로의 주파수 오프셋과 위상 기울기에 의한 이중 대역 특성을 갖는 혼합 우좌향 전송 선로를 이용하여 설계되었다. 높은 Q 특성의 공진기는 위상 잡음을 줄이기 위하여 사용되어 왔지만, 주파수 조절 범위가 감소하는 문제를 갖고 있다. 하지만 제안된 전압 제어 발진기의 주파수 조절 범위는 위상 잡음이 높은 Q 특성의 공진기 없이 감소하였기 때문에 줄어들지 않았다. 또한, 일반적인 우향 전송 선로 대신 혼합 우좌향 전송 선로를 이용하는 것을 통하여 회로의 크기를 소형화 하였다. 전압 제어 발진기의 위상 잡음은 5.731 ~ 5.938 GHz의 주파수 조절 범위 내에서 100 kHz의 오프셋 주파수에서 -119.17 ~ -117.50 dBc/Hz이다.

고 해상도 VCO 튜닝 기법을 이용한 MB-OFDM UWB용 주파수 합성기 (A Frequency Synthesizer for MB-OFDM UWB with Fine Resolution VCO Tuning Scheme)

  • 박준성;남철;김영신;부영건;허정;이강윤
    • 대한전자공학회논문지SD
    • /
    • 제46권8호
    • /
    • pp.117-124
    • /
    • 2009
  • 본 논문에서는 UWB용 송수신기에서 LO 주파수를 생성해주는 주파수 합성기의 설계 결과를 보여주고 있다. 빠른 채널 스위칭 시간을 만족하기 위해서 1개의 PLL 과 여러 개의 분주기들과 SSB 믹서를 이용한 Sub-Band Generator로 구성하였으며, 전류 소모 및 면적을 최소화 하도록 설계하였다. 또한, 효과적인 주파수 플래닝을 통하여, 1개의 PLL로부터 생성된 636 MHz의 단일 주파수를 입력으로 받아 UWB Band Group 1 에 해당하는 3432 MHz, 3960 MHz, 4488 MHz의 중심 주파수를 발생시키는 Sub-Band Generator를 설계하였다. VCO의 튜닝 범위를 넓히면서도, 해상도를 높이기 위하여 MIM 커패시터, Varactor, DAC를 이용한 새로운 고 해상도 VCO 튜닝 기법을 제안하였다. 또한 본 논문에서 제안한 주파수 합성기의 구조는 기저 대역 모뎀의 ADC를 위한 클록을 공급하기 때문에 모뎀에서 ADC에 클록을 공급하기 위한 PLL을 제거할 수 있는 장점이 있다. VCO의 튜닝 범위는 1.2 GHz이며, 6336 MHz의 출력 주파수에서의 위상 잡음은 1 MHz 옵셋에서 -112 dBc/Hz 로 측정 되었다. UWB용 PLL 및 Sub-Band Generator는 0.13 ${\mu}m$ CMOS 공정으로 설계하였으며, 전체 Chip 면적은 2 ${\times}$ 2 mm2 이다. 전력 소모는 1.2 V 의 공급 전원에서 60 mW이다.

실내 무선 DS-CDMA 방식에서 다중경로 페이딩 영향을 고려한 DLL 설계와 성능평가 (DLL Design and Performance Evaluation in Indoor Wireless DS-CDMA System under the Multipath Fading Effects)

  • 임성준;유호진;유흥균
    • 한국음향학회지
    • /
    • 제16권3호
    • /
    • pp.99-105
    • /
    • 1997
  • 이 논문에서는 다중경로 환경하에서 DLL (Delay lock loop)의 동작을 분석하였다. 전체 동작상태는 정상상태 시간오차 확률밀도함수와 MTLL (mean-time-to-lose-lock) 을 이용하여 분석하였다. 그리고 다중경로에서 페이딩 환경에서 지연성분의 존재로 진상-지상 판별함수 S(${\epsilon}$)가 0이 되는 추적 오차점 ${\epsilon}_{0}$가 0이 아님을 보이고, 지연성분의 전력 $g_{2}$, 지연시간 ${\tau}_{d}$의 증가로 인하여 ${\epsilon}_{0}$의 절대값이 증가하며, MTLL의 값이 작아짐을 보였다. 여기에서는 위의 변수들을 이용하여 다중경로 페이딩 환경에서의 시간오차 확률밀도함수와 MTLL을 선형적으로 구하였으며, 다중경로의 영향이 클 경우에는 MTLL은 상당히 낮아짐을 보이고, 이때 진상-지상 오프셋 ${\Delta}$의 증가시킴으로써 MTLL의 값을 증가시킬 수 있다는 것을 관찰하였다. 우리는 먼저 S(${\epsilon}$)가 0이 되는 추적오차점 ${\epsilon}_{0}$을 구하고, 이를 이용하여 진상-지상 판별함수 S(${\epsilon}$)를 선형 근사화시켰으며, 진상-지상 오프셋 ${\Delta}$의 증가에 따른 시간오차 확률밀도함수와 MTLL을 구하고 DDLL의 동작상태를 연구하여, 다중경로의 지연성분에 대한 전력 및 지연시간에 따라 MTLL이 상당히 낮게 되며, 이러한 경우 진상-지상 오프셋 ${\Delta}$을 증가시켜줌으로써 MTLL을 충분히 증가시키고 DLL의 성능을 개선할 수 있다는 결과를 얻었다.

  • PDF

목재 접합부의 강도특성 및 장기 내력 평가 (I) - 소나무재의 Bo1t 및 Drift pin 접합부 능력(耐力) 성능 평가 - (Studies on Evaluation for Long-term Loading of Composite Wood-joint and Characteristics of Joint Strength (I) - The strength properties of mechanical joints of Pinus densiflora with drift pin and bolt -)

  • 홍순일;황원중;김은삼;진광성
    • Journal of the Korean Wood Science and Technology
    • /
    • 제29권4호
    • /
    • pp.1-8
    • /
    • 2001
  • 본 실험은 강판삽입형에 드리프트 핀, 볼트를 이용한 2가지 형태의 접합부의 강도 특성을 검토하였다. 하중 방향은 섬유평행방향 하중 (0도 하중)과 섬유직교방향 하중 (90도 하중)을 가하여 하중방향의 차이 및 접합구에 따른 강도 특성을 비교하였다. 소나무재의 강판 삽입의 드리프트 핀, 볼트 인장형 전단강도 실험에서 다음과 같은 결과를 얻었다. 1. 같은 단거리의 섬유평행방향 하중시 최대하중은 접합구의 직경이 증가함에 따라 증가되는 경향을 보였으며, 90도 하중인 경우 드라프트핀, 볼트 접합부는 2가지 접합구 직경(10 mm, 12 mm)에서 모든 소나무 시편이 할렬파괴 되었다. 2. 하중-변형 곡선의 초기 직선영역을 나타내는 직선과 접합구 직경의 5% 만큼을 횡축의 정방향으로 평행 이동시킨 접합부의 항복하중(Py)과 최대 하중비의 증가 정도는 0도 하중의 경우가 높고, 볼트의 접합에서 높았다. 또한 세장비가 증가될수록 높은 경향을 나타냈다. 3 항복 추정식으로 구한 항복하중과 실험값에서 5% 차감한 항복하중은 볼트 접합부에 비해 드리프트 핀 접합부가 추정치와 실험치가 잘 일치되었다.

  • PDF

한국 동쪽 대륙주변부의 구조적 진화와 동해의 형성 (Structural Evolution of the Eastern Margin of Korea: Implications for the Opening of the East Sea (Japan Sea))

  • 김한준;주형태;이광훈;유해수;박건태
    • 자원환경지질
    • /
    • 제39권3호
    • /
    • pp.235-253
    • /
    • 2006
  • 해양탄성파 프로파일을 정밀수심 및 자력자료와 함께 해석하여, 일본열도가 분리되어 동해가 형성된 한반도의 대륙 주변부에서 진행된 리프팅과 지각의 분리 과정을 연구하였다. 한반도의 주변부는 바다쪽으로 리프트분지와 융기된 리프트 측면부, 그리고 경사가 급한 대륙사면이 연속된, 비활성 대륙주변부에서 전형적으로 볼 수 있는 기본적인 리프트구조로 이루어져 있다. 북쪽지역에서는 한반도로부터 연장되고 부분적으로 분절된 대륙지각인 한국대지에서 리프팅이 발생하였다. 한국대지는 상대적으로 넓은 신장지역을 제공하여 많은 수의 리프트를 형성하였다. 한국대지 내에서 두 개의 눈에 띄는 리프트 분지(온누리와 반달 분지)는 주된 synthetic 단층과 더 작은 규모의 antithetic 단층에 의해 형성되어 넓고 대칭적인 구조를 갖는다. 이들 분지에서 변위가 큰 경계단층지역은 볼록한 경사면을 가지며 주향방향으로 지그재그 모양을 보인다. 대조적으로, 남쪽 주변부에는 비대칭적인 반지구로서 하나의 좁은 리프트분지(후포 분지)가 길게 형성되어 있다. 한반도 주변부의 리프팅은 주향이동 운동에 의한 변위가 아니라 대륙사면의 기저부를 따라 발생하였다고 유추되는 지각의 분리에 수직하는 서쪽 및 남동방향의 신장의 결과인 정단층작용에 의해 주로 유도되었다고 해석된다. 리프팅 동안에는 화산작용이 거의 없었으나 해저면 확장의 초기단계에서는 상당한 화산작용이 수반되었으며 이것은 특히 남쪽지역에서 리프트에 의해 유도되는 맨틀대류뿐만 아니라 슬랩에 의해 유도되는 약권의 상승을 반영한다고 보여 진다. 동해의 생성과 관련된 한반도 주변부의 구조 및 화산운동은 후열도 환경에서의 약권 상승에 의해 영향을 받는 화산작용을 수반한 비활성 대륙주변부에서 일어나는 과정으로 설명할 수 있다고 해석된다.

하중의 위치 및 경사에 따른 임플랜트 보철의 유한요소법적 응력분석 (Finite Element Stress Analysis of Implant Prosthesis according to Position and Direction of Load)

  • 배숙진;정재헌;정승미
    • 구강회복응용과학지
    • /
    • 제19권4호
    • /
    • pp.257-268
    • /
    • 2003
  • The purpose of this study was to assess the loading distributing characteristics of implant prosthesis according to position and direction of load, under vertical and inclined loading using FEA analysis. The finite element model was designed according to standard fixture (4.1mm restorative component x 11.5mm length). The crown for mandibular first molar was made using UCLA abutment. Each three-dimensional finite element model was created with the physical properties of the implant and surrounding bone. This study simulated loads of 200N at the central fossa in a vertical direction (loading condition A), 200N at the outside point of the central fossa with resin filling into screw hole in a vertical direction (loading condition B), 200N at the centric usp in a $15^{\circ}$ inward oblique direction (loading condition C), 200N at the in a $30^{\circ}$ inward oblique direction (loading condition D) or 200N at the centric cusp in a $30^{\circ}$ outward oblique direction (loading condition E) individually. Von Mises stresses were recorded and compared in the supporting bone, fixture, and abutment screw. The following results have been made based on this study: 1. Stresses were concentrated mainly at the ridge crest around implant in both vertical and oblique loading but stresses in the cancellous bone were low in both vertical and oblique loading. 2. Bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. The magnitude of the stress was greater with the oblique loading than with the vertical loading. 3. An offset of the vertical occlusal force in the buccolingual direction relative to the implant axis gave rise to increased bending of the implant. 4. The relative positions of the resultant line of force from occlusal contact and the center of rotation seems to be more important. 5. The magnitude of the stress in the supporting bone, fixture and abutment screw was greater with the outward oblique loading than with the inward oblique loading and was the greatest under loading at the centric cusp in a $30^{\circ}$ outward oblique direction. Conclusively, this study provides evidence that bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. But it seems to be more important that how long is the distance from center of rotation of the implant itself to the resultant line of force from occlusal contact(leverage). The goal of improving implants should be to avoid bending of the implant.

임플랜트-지대주의 내측연결 시스템에서 하중의 위치 및 경사에 따른 임플랜트 보철의 유한요소 응력분석 (Finite Element Stress Analysis of Implant Prosthesis of Internal Connection System According to Position and Direction of Load)

  • 장종석;정용태;정재헌
    • 구강회복응용과학지
    • /
    • 제21권1호
    • /
    • pp.1-14
    • /
    • 2005
  • The purpose of this study was to assess the loading distributing characteristics of implant prosthesis of internal connection system(ITI system) according to position and direction of load, under vertical and inclined loading using finite element analysis (FEA). The finite element model of a synOcta implant and a solid abutment with $8^{\circ}$ internal conical joint used by the ITI implant was constructed. The gold crown for mandibular first molar was made on solid abutment. Each three-dimensional finite element model was created with the physical properties of the implant and surrounding bone. This study simulated loads of 200N at the central fossa in a vertical direction (loading condition A), 200N at the outside point of the central fossa with resin filling into screw hole in a vertical direction (loading condition B), 200N at the centric cusp in a $15^{\circ}$ inward oblique direction (loading condition C), 200N at the in a $30^{\circ}$ inward oblique direction (loading condition D) or 200N at the centric cusp in a $30^{\circ}$ outward oblique direction (loading condition E) individually. Von Mises stresses were recorded and compared in the supporting bone, fixture, and abutment. The following results have been made based on this study: 1. Stresses were concentrated mainly at the ridge crest around implant under both vertical and oblique loading but stresses in the cancellous bone were low under both vertical and oblique loading. 2. Bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. The magnitude of the stress was greater with the oblique loading than with the vertical loading. 3. An offset of the vertical occlusal force in the buccolingual direction relative to the implant axis gave rise to increased bending of the implant. So, the relative positions of the resultant line of force from occlusal contact and the center of rotation seems to be more important. 4. In this internal conical joint, vertical and oblique loads were resisted mainly by the implant-abutment joint at the screw level and by the implant collar. Conclusively, It seems to be more important that how long the distance is from center of rotation of the implant itself to the resultant line of force from occlusal contact (leverage). In a morse taper implant, vertical and oblique loads are resisted mainly by the implant-abutment joint at the screw level and by the implant collar. This type of implant-abutment connection can also distribute forces deeper within the implant and shield the retention screw from excessive loading. Lateral forces are transmitted directly to the walls of the implant and the implant abutment mating bevels, providing greater resistance to interface opening.

측정부위별 신생아의 체온 비교 : 고막기준 직장체온, 직장체온, 액와체온, 복부체온 (Comparison by Measurement Sites in Temperature of Neonates : Ear-based rectal, Rectal, Axilla, Abdominal Temperature)

  • 김화순;안영미
    • 대한간호학회지
    • /
    • 제29권4호
    • /
    • pp.903-916
    • /
    • 1999
  • The purpose of this study was to compare the ear-based rectal temperature measured with a tympanic thermometer with the rectal temperature measured with a glass mercury thermometer in order to test the accuracy of tympanic thermometer and to determine relationship among rectal, axilla, and abdominal temperature in neonates. The samples consisted of thirty four neonates admitted to the neonatal intensive care unit and nursery at an university affiliated hospital. The mean age of the subjects was 4.9 days. The ear-based rectal temperatures were taken with a tympanic thermometer in rectal mode (First Temp Genius 3000). Rectal and axilla temperatures were taken with a glass mercury thermometer, Abdominal temperature was continuously monitored with the probe connected to the servo controller of incubator. The results of the study can be summarized as follows : 1. Intrarater comparison : Agreement between the first and the second ear-based rectal temperature was 97% within 0.1$^{\circ}C$. 2. Comparison of ear-based rectal temperature and the rectal temperature from a glass mercury thermometer : ear-based rectal temperature ranged from 36.95$^{\circ}C$d to 37.95$^{\circ}C$, with a mean of 37.58$^{\circ}C$(SD=0.22$^{\circ}C$). Rectal temperature from a glass mercury thermometer ranged from 36.2$0^{\circ}C$ to 37.2$0^{\circ}C$, with a mean 36.75$^{\circ}C$(SD=0.29). The mean difference between both temperatures was 0.84$^{\circ}C$. The correlation coefficient between both temperatures was r=0.77(p=0.00). 3. Comparison of rectal and axilla temperature : Axilla temperature ranged from 35.8$0^{\circ}C$ to 37.1$0^{\circ}C$, with a mean of 36.55$^{\circ}C$. The mean absolute difference between the rectal and axilla temperature was 0.23$^{\circ}C$. The correlation coefficient between rectal and axilla was r=0.67. 4. Comparison of axilla and abdominal temperature : Abdominal temperature ranged from 36.2$0^{\circ}C$ to 37.0$0^{\circ}C$, with a mean of 36.58$^{\circ}C$. The mean absolute difference between axilla and abdominal temperature was only -0.03$^{\circ}C$. Findings of this study suggest that ear-based rectal temperature overestimates the actual rectal temperatures in neonates. Therefore, the interchangeble use of both temperatures in clinics seems problematic. The site offset(adjustment value) programmed in rectal mode of the tympanic thermometer needs to be readjusted. Choosing one optimal site for temperature measurement for each patient, and using the specific site consistently would result in more consistent measurements of changes in body temperature, and thus can be more effective in diagnosing fever or hypothermia.

  • PDF