• Title/Summary/Keyword: 3D-CRT

Search Result 110, Processing Time 0.027 seconds

Effect of CT Contrast Media on Radiation Therapy Planning (Head & Neck Cancer and Prostate Cancer) (CT조영제가 방사선치료계획(두경부, 전립선)에 미치는 영향)

  • Jang, Jaeuk;Han, Manseok;Kim, Minjeong;Kang, Hyeonsoo
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.5
    • /
    • pp.173-178
    • /
    • 2016
  • This study is to evaluate the effect of a Contrast Media (CM) on dose calculations and clinical significance in Radiation (Electromagnetic wave) Therapy (RT) plans for head & neck (H&N) and prostate cancer. Pinnacle 8.0 system was used to measure the change of Electron Density (ED) of the tissue for CM. To determine the effect of dose calculation due to CM, we did the RT planning for 30 patients. To compare the ED and dose calculations of RT plans, 3D CRT and IMRT plans were do with pinnacle and Tomotherapy planning system. Mean difference of ED between enhanced and unenhanced CT was less than 4%: H&N Target Volume (TV) 2.1%, parotid 1.9%, SMG 3.6%, tongue 0.9%, spinal cord 0.3%, esophagus 2.6%, mandible 0.1% and prostate TV 0.7%, lymph node 1.1%, bladder 1.2%, rectum 1.5%, small bowel 1.2%, colon 0.6%, penile bulb 0.8%, femoral head -0.2%. The dose difference between RT plan using CM and without CM showed an increase of dose in TV. The rate of increase was less than 2.5% (3D CRT: H&N 0.69~2.51%, prostate 0.04~1.14%, IMRT: H&N 0.58~1.31%, prostate 0.36~1.04%). RT plans using a CM has the insignificant effect on the organs and TV, so this error is allowable clinically. However, the much more accurate plan is possible as to image fusion (CM and without CM images) to ROI contour and when dose calculation, use the without CM image. Using the fusion of 'ROI import' perform calculations on without CM, it will be able to reduce the error (1~3%) caused by the CM.

Isolation and Molecular Characterization of a New CRT Binding Factor Gene from Capsella bursa-pastoris

  • Wang, Xinglong;Liu, Li;Liu, Sixiu;Sun, Xiaoqing;Deng, Zhongxiang;Pi, Yan;Sun, Xiaofen;Tang, Kexuan
    • BMB Reports
    • /
    • v.37 no.5
    • /
    • pp.538-545
    • /
    • 2004
  • A new CRT binding factor (CBF) gene designated Cbcbf25 was cloned from Capsella bursa-pastoris, a wild grass, by the rapid amplification of cDNA ends (RACE). The full-length cDNA of Cbcbf25 was 898 bp with a 669 bp open reading frame (ORF) encoding a putative DRE/CRT (LTRE)-binding protein of 223 amino acids. The predicted CbCBF25 protein contained a potential nuclear localization signal (NLS) in its N-terminal region followed by an AP2 DNA-binding motif and a possible acidic activation domain in the C-terminal region. Bioinformatic analysis revealed that Cbcbf25 has a high level of similarity with other CBF genes like cbf1, cbf2, and cbf3 from Arabidopsis thaliana, and Bncbf5, Bncbf7, Bncbf16, and Bncbf17 from Brassica napus. A cold acclimation assay showed that Cbcbf25 was expressed immediately after cold triggering, but this expression was transient, suggesting that it concerns cold acclimation. Our study implies that Cbcbf25 is an analogue of other CBF genes and may participate in cold-response, by for example, controlling the expression of cold-regulated genes or increasing the freezing tolerance of plants.

A Study of Total Dose in Intensity Modulation Radiation Therapy (선량강도 조절법을 이용한 방사선치료에서 총선량에 관한 고찰)

  • 김성규
    • Progress in Medical Physics
    • /
    • v.11 no.1
    • /
    • pp.85-90
    • /
    • 2000
  • In radiation therapy, the effects of radiation are decided total dose, total treatment times and number of radiation dose fractions. We considered that total dose, total treatment times and number of radiation dose fractions in intensity modulation radiation therapy(IMRT) infuence tumor cell killing. The goal of three dimensional conformal radiation therapy(3DCRT) in radiation therapy is to conform the partial distribution of the prescribed radiation dose to the precise 3D configuration of the tumor, and at the same time, to minimize the dose to the surrounding normal tissues. To optimize treatment volume of tumor, treatment volume will be same tumor volume. All IMRT compare to conventional treatment plus boost IMRT when total dose irradiated 75 - 90 Gy. Because of biological effect, total dose are decreased 12.5 - l5Gy in all IMRT.

  • PDF

PTV Margins for Prostate Treatments with an Endorectal Balloon (전립선 암의 방사선치료 시 직장 내 풍선삽입에 따른 계획표적부피마진)

  • Kim, Hee-Jung;Chung, Jin-Beom;Ha, Sung-Whan;Kim, Jae-Sun;Ye, Sung-Joon
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.166-176
    • /
    • 2010
  • Purpose: To determine the appropriate prostate planning target volume (PTV) margins for 3-dimensitional (3D) conformal radiotherapy (CRT) and intensity-modulated radiation therapy (IMRT) patients treated with an endorectal balloon (ERB) under our institutional treatment condition. Materials and Methods: Patients were treated in the supine position. An ERB was inserted into the rectum with 70 cc air prior to planning a CT scan and then each treatment fraction. Electronic portal images (EPIs) and digital reconstructed radiographs (DRR) of planning CT images were used to evaluate inter-fractional patient's setup and ERB errors. To register both image sets, we developed an in-house program written in visual $C^{++}$. A new method to determine prostate PTV margins with an ERB was developed by using the common method. Results: The mean value of patient setup errors was within 1 mm in all directions. The ERB inter-fractional errors in the superior-inferior (SI) and anterior-posterior (AP) directions were larger than in the left-right (LR) direction. The calculated 1D symmetric PTV margins were 3.0 mm, 8.2 mm, and 8.5 mm for 3D CRT and 4.1 mm, 7.9 mm, and 10.3 mm for IMRT in LR, SI, and AP, respectively according to the new method including ERB random errors. Conclusion: The ERB random error contributes to the deformation of the prostate, which affects the original treatment planning. Thus, a new PTV margin method includes dose blurring effects of ERB. The correction of ERB systematic error is a prerequisite since the new method only accounts for ERB random error.

Benefit of volumetric-modulated arc therapy over three-dimensional conformal radiotherapy for stage I-II extranodal marginal zone B-cell lymphoma of mucosa-associated lymphoid tissue in the stomach: a dosimetric comparison

  • Chung, Joo-Hyun;Na, Kyoungsu;Kim, Il Han
    • Radiation Oncology Journal
    • /
    • v.36 no.4
    • /
    • pp.332-340
    • /
    • 2018
  • Purpose: To retrospectively analyze dosimetric parameters of volumetric-modulated arc therapy (VMAT) and three-dimensional conformal radiotherapy (3D-CRT) delivered to extranodal marginal zone B-cell lymphomas of mucosa-associated lymphoid tissue in the stomach (gastric MALT lymphoma) to find out advantages of VMAT and conditions for definite benefits of VMAT. Materials and Methods: Fifty patients with stage I-II gastric MALT lymphoma received VMAT (n = 14) or 3D-CRT (n = 36) between December 2005 and April 2018. Twenty-seven patients were categorized according to whether the planning target volume (PTV) overlaps kidney(s). Dosimetric parameters were analyzed by dose-volume histogram. Results: Radiation dose to the liver was definitely lower with VMAT in terms of mean dose (p = 0.026) and V15 (p = 0.008). The V15 of the left kidney was lower with VMAT (p = 0.065). For those with PTV overlapping kidney(s), the left kidney V15 was significantly lower with VMAT. Furthermore, the closer the distance between the PTV and kidneys, the less the left kidney V15 with VMAT (p = 0.037). Delineation of kidney(s) by integrating all respiratory phases had no additional benefit. Conclusions: VMAT significantly increased monitor units, reduced treatment time and radiation dose to the liver and kidneys. The benefit of VMAT was definite in reducing the left kidney V15, especially in geometrically challenging conditions of overlap or close separation between PTV and kidney(s).

Evaluation of DVH and NTCP in Hepatoma for 3D Conformal Radiation Therapy (3차원 입체조형치료에 대한 간암의 선량분포와 정상조직손상확률의 평가)

  • Chung, Kap-Soo;Yang, Han-Joon;Ko, Shin-Gwan
    • Journal of radiological science and technology
    • /
    • v.20 no.2
    • /
    • pp.79-82
    • /
    • 1997
  • Image-based three dimensional radiation treatment planning(3D RTP) has a potential of generating superior treatment plans. Advances in computer technology and software developments quickly make 3D RTP a feasible choice for routine clinical use. However, it has become clear that an evaluation of a 3D plan is more difficult than a 2D plan. A number of tools have been developed to facilitate the evaluation of 3D RTP both qualitatively and quantitatively. For example, beam's eye view(BEV) is one of the most powerful and time-saving method as a qualitative tools. Dose-volume histogram(DVH) has been proven to be one of the most valuable methods for a quantitative tools. But it has a limitation to evaluate several different plans for biological effects of the tissue and critical organ. Therefore, there is a strong interest in developing quantitative models which would predict the likely biological response of irradiated organs and tissues, such as tumor control probability(TCP) and normal tissue complication probability(NTCP). DVH and NTCP of hepatoma were evaluated for three dimensional conformal radiotherapy(3D CRT). Also, 3D RTP was analysed as a dose optimization based on beam arrangement and beam modulation.

  • PDF

Study of Blurring Free TFT-LCD Using Short Persistance Cold Cathode Fluorescent Lamp in Blinking Backlight Driving (단잔광 냉음극관을 이용한 잔상없는 TFT-LCD에 관한 연구)

  • Choi, Dae-Seub;Sin, Ho-Chul
    • Journal of Satellite, Information and Communications
    • /
    • v.7 no.3
    • /
    • pp.145-148
    • /
    • 2012
  • In applying LCD to TV application, one of the most significant factors to be improved is image sticking on the moving picture. LCD is different from CRT in the sense that it's continuous passive device, which holds images in entire frame period, while impulse type device generate image in very short time. To reduce image sticking problem related to hold typedisplay mode, we made an experiment to drive TN-LCD like CRT. We made articulate images by turn on-off backlight, and we realized the ratio of Back Light on-off time by counting between on time and off time for video signal input during 1 frame (16.7ms). Conventional CCFL (cold cathode fluorescent lamp) cannot follow fast on-off speed, so we evaluated new fluorescent substances of light source to improve residual light characteristic of CCFL. We realized articulate image generation similar to CRT by CCFL blinking drive and TN-LCD overdriving. As a result, reduced image sticking phenomenon was validated by naked eye and response time measurement.

The Performance Test on A Continuous Regeneration DPF in A HD Diesel Engine (대형디젤기관에 있어서 연속재생방식 매연저감장치 성능 테스트)

  • Baik, Doo-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.5
    • /
    • pp.788-792
    • /
    • 2006
  • The test was conducted on an 8000cc heavy-duty turbo-charged heavy-duty diesel engine on which continuous regeneration DPF was installed in order to investigate regeneration characteristics fur DPF and engine performance under conditions of standard (430ppm) or ultra low sulfur diesel (50ppm) and the results were compared with each other. Exhaust emissions, CO, HC, NOx, PM and soot were investigated carefully and tested under D-13 and D-3 modes.

  • PDF

Representation Techniques for 4-Dimensional MR Images

  • Homma, Kazuhiro;Takenaka, Kenji;Nakai, Yoshihiko;Hirose, Takeshi
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.429-431
    • /
    • 2002
  • Metabolic analysis of biological tissues, the interventional radiology in MRT (Magnetic Resonance Treatment) and for clinical diagnoses, representation of 4-Dimensional (4D) structural information (x,y,z,t) of biological tissues is required. This paper discusses image representation techniques for those 4D MR Images. We have proposed an image reconstruction method for ultra-fast 3D MRI. It is based on image interpolation and prediction of un-acquired pictorial data in both of the real and the k-space (the acquisition domain in MRI). A 4D MR image is reconstructed from only two 3D MR images and acquired a few echo signals that are optimized by prediction of the tissue motion. This prediction can be done by the phase of acquired echo signal is proportioned to the tissue motion. On the other hand, reconstructed 4D MR images are represented as a 3D-movie by using computer graphics techniques. Rendered tissue surfaces and/or ROIs are displayed on a CRT monitor. It is represented in an arbitrary plane and/or rendered surface with their motion. As examples of the proposed representation techniques, the finger and the lung motion of healthy volunteers are demonstrated.

  • PDF

Enhanced Lycopene Production by UV-C Irradiation in Radiation-Resistant Deinococcus radiodurans R1

  • Kang, Chang Keun;Yang, Jung Eun;Park, Hae Woong;Choi, Yong Jun
    • Journal of Microbiology and Biotechnology
    • /
    • v.30 no.12
    • /
    • pp.1937-1943
    • /
    • 2020
  • Although classical metabolic engineering strategies have succeeded in developing microbial strains capable of producing desired bioproducts, metabolic imbalance resulting from extensive genetic manipulation often leads to decreased productivity. Thus, abiotic strategies for improving microbial production performance can be an alternative to overcome drawbacks arising from intensive metabolic engineering. Herein, we report a promising abiotic method for enhancing lycopene production by UV-C irradiation using a radiation-resistant ΔcrtLm/crtB+dxs+ Deinococcus radiodurans R1 strain. First, the onset of UV irradiation was determined through analysis of the expression of 11 genes mainly involved in the carotenoid biosynthetic pathway in the ΔcrtLm/crtB+dxs+ D. radiodurans R1 strain. Second, the effects of different UV wavelengths (UV-A, UV-B, and UV-C) on lycopene production were investigated. UV-C irradiation induced the highest production, resulting in a 69.9% increase in lycopene content [64.2 ± 3.2 mg/g dry cell weight (DCW)]. Extended UV-C irradiation further enhanced lycopene content up to 73.9 ± 2.3 mg/g DCW, a 95.5% increase compared to production without UV-C irradiation (37.8 ± 0.7 mg/g DCW).