• Title/Summary/Keyword: 3D scan data

Search Result 398, Processing Time 0.034 seconds

The Design of Optical Marker for Auto-registering of 3D scan data (3차원 스캐너의 레지스터링 문제 해결을 위한 광학식 마커 설계)

  • 손용훈;양현석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.256-259
    • /
    • 2003
  • This paper proposes OPTICAL MARKER fer registering process - one of the 3D measurement process : scan registering - merging - measurement. If the registering work is carried out manually, it can be accompanied with much time and many errors. Because the patterned marker make registering process automatic, many firms use it now. But the physical shape of existing markers is the source of the data loss caused by hiding surface, and the marker arrangement is the source of the time loss. The optical marker proposed in this paper has marker generator, organized a large number of binary coded control laser diode, separate from 3D scan object. So, it does not take much time for the marker disposition, and it is not the origin of the data loss, and the binary coded laser information make the auto-registering possible.

  • PDF

Usability verification of virtual clothing system for the production of a 3D avatar reproduced from 3D human body scan shape data - Focusing on the CLO 3D program - (3차원 인체스캔형상을 재현한 3D 아바타 제작을 위한 가상착의 시스템의 활용성 검증 -CLO 3D 프로그램을 중심으로-)

  • Hong, Eun-Hee
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.22 no.1
    • /
    • pp.1-13
    • /
    • 2020
  • The purpose of this study is to create a 3D avatar from 3D human body shape data using the CLO 3D virtual clothing program and to verify the feasibility of avatar production using the virtual clothing system for verifying size and shape. The research method was to select one virtual representative model that is the closest to the mean size of each body item for each age group. Using the 3D human body scan shape of a 40-69 years old male was applied to the CLO 3D virtual wearing system. Using the CLO 3D Avatar conversion menu, we verified the feasibility of creating a 3D avatar that reproduces the human body scan shape. In the dimension comparison between the 3D avatar and the fictitious representative model, the dimension difference was noticeable in height, circumference, and length. However, as a result, the converted 3D avatar showed less than a 5% difference in most human dimensions. In addition, since the body shape and posture were reproduced similarly, the utilization of the avatar was verified.

Landmark Extraction for 3D Human Body Scan Data Using Markerless Matching (마커 없는 매칭을 활용한 3 차원 인체 스캔 데이터의 기준점 추출)

  • Yoon, Dong-Wook;Heo, Nam-Bin;Ko, Hyeong-Seok
    • 한국HCI학회:학술대회논문집
    • /
    • 2009.02a
    • /
    • pp.163-167
    • /
    • 2009
  • 3D human body scan technique is known to be practically useful in industrial field as the technique becomes more precise and cheaper. Landmark extraction is essential for full utilization of the scan data. In this paper, we suggest an algorithm for automatic landmark extraction. For this purpose, we perform markerless matching to the target data using PCA analysis and quasi-Newton optimization. Landmarks are extracted from the topology of resulting body.

  • PDF

Belt Pattern Making for Hip-hugger garment using 3D Body Scan Data (3차원 인체 스캔 데이터를 활용한 Hip-hugger 의류용 벨트 패턴 설계)

  • Park, Soon-Jee;Choi, Sin-Ae
    • Fashion & Textile Research Journal
    • /
    • v.10 no.5
    • /
    • pp.652-659
    • /
    • 2008
  • This study was designed to testify the possibility and devise the method to manipulate the 3D body scan data to produce rounded-belt pattern adaptable to hip-type variation of women in their 20's. The results of this research were as follows : Firstly, based on drop-value distribution of hip and waist girth, 151 subjects were classified into three hip-types; Type 1 (15.23%) was 'cylinder type', showing lowest drop-value, Type 2 (69.54%) was 'average type' and Type3 (15.23%) was 'hourglass type' showing highest drop-value. Secondly, using CAD program, design lines for round shape belt were set on the surface of 3D scan data of representative subject of each type. And divided 3D surfaces were flattened onto the plane by the internal tools of CAD program. The measure, 'lifting value of round belt pattern', implying the level of curve ratio of pattern was higher in back than front. This result might be linked to the fact that the hip part is more protruded than the abdomen part. And the measures also showed highest values in Type 3(hourglass type) and lowest in Type 1(cylinder type), meaning that the pattern of Type 3 showed more rounded shape than that of Type 1. This finding implied that round belt for body type having high drop-value should be shaped more curved. Thirdly, difference ratios of outline length and area between 3D curves(body surface) and 2D plane(pattern) were 4.5% and 1.3%, respectively. This result demonstrated and solidified the feasibility of designing digital garment pattern from 3D body scan data.

2D Pattern Development of Tight-fitting Bodysuit from 3D Body Scan Data for Comfortable Pressure Sensation (인체의 3차원 스캔 데이터를 이용한 밀착 바디 슈트 개발)

  • Jeong, Yeon-Hee
    • Korean Journal of Human Ecology
    • /
    • v.15 no.3
    • /
    • pp.481-490
    • /
    • 2006
  • Adjusting pressure level in the construction of athletes' tight-fitting garments by reducing the elastic knit pattern is a challenging subject, which influences the performance of the wearer directly. Therefore, in this study, relationship between the reduction rates of the basic pattern obtained from 3D human scan data and resultant clothing pressure was explored to improve the fit and pressure exerted by clothing. 3D scan data were obtained using Cyberware and they were transformed into a flat pattern using software based on Runge-Kutta method. Reduction rate was examined by subjective wear test as well as objective pressure measurement. As a result, difference in the length between the original 3D body scan data and the 2D tight-fitting pattern was 0.02$\sim$0.50cm (0.05$\sim$1.06%), which was within the range of tolerable limits in making clothes. Among the five garments, the 3T-pattern was superior in terms of subjective sensation and fit. The pressure of the 3T pattern was 2$\sim$4 gf/cm2 at five locations on the body, which is almost the same or a bit higher than that of Z-pattern. In the case of tight-fitting overall garment, the reduction rate of the pattern in the wale direction is more critical to the subjective sensation than the course direction. It is recommended that the reduction grading rules of course direction should be larger than that of Ziegert for a better fit of tight-fitting garments. In the case of wale direction, however, reduction grading rule should be kept the same as suggested earlier by Ziegert (1988).

  • PDF

Localization and 3D Polygon Map Building Method with Kinect Depth Sensor for Indoor Mobile Robots (키넥트 거리센서를 이용한 실내 이동로봇의 위치인식 및 3 차원 다각평면 지도 작성)

  • Gwon, Dae-Hyeon;Kim, Byung-Kook
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.9
    • /
    • pp.745-752
    • /
    • 2016
  • We suggest an efficient Simultaneous Localization and 3D Polygon Map Building (SLAM) method with Kinect depth sensor for mobile robots in indoor environments. In this method, Kinect depth data is separated into row planes so that scan line segments are on each row plane. After grouping all scan line segments from all row planes into line groups, a set of 3D Scan polygons are fitted from each line group. A map matching algorithm then figures out pairs of scan polygons and existing map polygons in 3D, and localization is performed to record correct pose of the mobile robot. For 3D map-building, each 3D map polygon is created or updated by merging each matched 3D scan polygon, which considers scan and map edges efficiently. The validity of the proposed 3D SLAM algorithm is revealed via experiments.

Method of 3D Body Surface Segmentation and 2D Pattern Development Using Triangle Simplification and Triangle Patch Arrangement (Triangle Simplification에 의한 3D 인체형상분할과 삼각조합방법에 의한 2D 패턴구성)

  • Jeong, Yeon-Hee;Hong, Kyung-Hi;Kim, See-Jo
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.29 no.9_10 s.146
    • /
    • pp.1359-1368
    • /
    • 2005
  • When we develop the tight-fit 2D pattern from the 3D scan data, segmentation of the 3D scan data into several parts is necessary to make a curved surface into a flat plane. In this study, Garland's method of triangle simplification was adopted to reduce the number of data point without distorting the original shape. The Runge-Kutta method was applied to make triangular patch from the 3D surface in a 2D plane. We also explored the detailed arrangement method of small 2D patches to make a tight-fit pattern for a male body. As results, minimum triangle numbers in the simplification process and efficient arrangement methods of many pieces were suggested for the optimal 2D pattern development. Among four arrangement methods, a block method is faster and easier when dealing with the triangle patches of male's upper body. Anchoring neighboring vertices of blocks to make 2D pattern was observed to be a reasonable arrangement method to get even distribution of stress in a 2D plane.

Development of Registration Post-Processing Technology to Homogenize the Density of the Scan Data of Earthwork Sites (토공현장 스캔데이터 밀도 균일화를 위한 정합 후처리 기술 개발)

  • Kim, Yonggun;Park, Suyeul;Kim, Seok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.5
    • /
    • pp.689-699
    • /
    • 2022
  • Recently, high productivity capabilities have been improved due to the application of advanced technologies in various industries, but in the construction industry, productivity improvements have been relatively low. Research on advanced technology for the construction industry is being conducted quickly to overcome the current low productivity. Among advanced technologies, 3D scan technology is widely used for creating 3D digital terrain models at construction sites. In particular, the 3D digital terrain model provides basic data for construction automation processes, such as earthwork machine guidance and control. The quality of the 3D digital terrain model has a lot of influence not only on the performance and acquisition environment of the 3D scanner, but also on the denoising, registration and merging process, which is a preprocessing process for creating a 3D digital terrain model after acquiring terrain scan data. Therefore, it is necessary to improve the terrain scan data processing performance. This study seeks to solve the problem of density inhomogeneity in terrain scan data that arises during the pre-processing step. The study suggests a 'pixel-based point cloud comparison algorithm' and verifies the performance of the algorithm using terrain scan data obtained at an actual earthwork site.

Application Two-Dimensional Pattern Development of Cycling Tights based on the Three-Dimensional Body Scan Data of High School Male Cyclist

  • Park, Hyunjeong;Do, Wolhee
    • Fashion & Textile Research Journal
    • /
    • v.22 no.5
    • /
    • pp.595-606
    • /
    • 2020
  • This study develops an optimal two-dimensional (2D) pattern from three-dimensional human scan data by considering the cycling posture and dermatome of high school male cyclists. By analyzing the body surface change in the cycling posture and considering the dermatome of the lower limbs, the optimal cutting line setting and the development of cycling tights for individual cyclists were presented to provide data that could be used in the clothing industry. We designed three cycling tights to solve the size unsuitability. 3D design 1 is a non-extension design based on the analysis of the 3D human body scan data, in which parts were connected diagonally from the front of the knee to the back of the knee. 3D design 2 removed both the front and back to reduce air resistance during cycling. 3D design 3 did not have a cutting line on the front panel because of the air resistance during cycling in the front area. We analyzed the garment pressure for 8 points of lower body and performed a subjective evaluation of the 3D designed tights and the current cycling tights. The 3D design 1 in this study was well received in the omphalion, thigh, and hip area, while 3D design 3 was well received in the omphalion, thigh, hip, and bottom bands. Therefore, the LoNE of 3D design 1 was applied to the front, and the hip cutting line of 3D design 3 was applied to the back.

The Verification of Accuracy of 3D Body Scan Data - Focused on the Cyberware WB4 Whole Body Scanner - (3차원 인체 스캔 데이터의 정확도 검증에 관한 연구 - Cyberware의 WB4 스캐너를 중심으로 -)

  • Park, Sun-Mi;Nam, Yun-Ja
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.14 no.1
    • /
    • pp.81-96
    • /
    • 2012
  • The purpose of this study is to provide fundamental information for standardization of 3D body measurement. This research analyzes errors occurring in the process of extracting body size from 3D body scan data. First, as a result of analyzing basic state of the 3D body scanner's calibration, the point number of each section was almost the same, while the right and left as well as the front and back coordinates of the center of gravity are not, showing unstable data. Nevertheless, the latter does not influence on the size of cylinder such as width and circumference. Next, we analyzed point coordinates variations of scan data on a mannequin nude by life casting. The result was great deflection in case of complicated or horizontal sections including the reference point beyond proper distance from centers of four cameras. In case of the mannequin's size, accuracy proves comparatively high in that measurement errors in height, width, depth, and length dimension occurred all within allowable errors, only except chest depth, while there were a lot of measurement errors in a circumference dimension. Secondly, analysis of accuracy of automatic extraction identification program algorithm presented that a semi-automatic measurement program is better than an automatic measurement program. While both of them ate very acute in parts related to crotch, they are not in armpit related parts. Therefore, in extracting of human body size from 3D scan data, what really matters seems to parts related to armpits.

  • PDF