• Title/Summary/Keyword: 3D isolation device

Search Result 36, Processing Time 0.028 seconds

Analysis of Seismic Response According to Installation Location of Seismic Isolation System Applied to High-Rise Building (고층 건물에 적용한 면진 시스템의 설치 위치에 따른 지진 응답 분석)

  • Kim, Min-Ju;Kim, Dong-Uk;Kim, Hyun-Su;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.18 no.4
    • /
    • pp.81-88
    • /
    • 2018
  • Seismic isolation systems have typically been used in the form of base seams in mid-rise and low-rise buildings. In the case of high-rise buildings, it is difficult to apply the base isolation. In this study, the seismic response was analyzed by changing the installation position of the seismic isolation device in 3D high - rise model. To do this, we used 30-story and 40-story 3D buildings as example structures. Historic earthquakes such as Mexico (1985), Northridge (1994) and Rome Frieta (1989) were applied as earthquake loads. The installation position of the isolation device was changed from floor to floor to floor. The maximum deformation of the seismic isolation system was analyzed and the maximum interlaminar strain and maximum absolute acceleration were analyzed by comparing the LB model with seismic isolation device and the Fixed model, which is the base model without seismic isolation device. If an isolation device is installed on the lower layer, it is most effective in response reduction, but since the structure may become unstable, it is effective to apply it to an effective high-level part. Therefore, engineers must consider both structural efficiency and safety when designing a mid-level isolation system for high-rise buildings.

Seismic evaluation of isolated skewed bridges using fragility function methodology

  • Bayat, M.;Daneshjoo, F.;Nistico, N.;Pejovic, J.
    • Computers and Concrete
    • /
    • v.20 no.4
    • /
    • pp.419-427
    • /
    • 2017
  • A methodology, based on fragility functions, is proposed to evaluate the seismic performance of seismic isolated $45^{\circ}$ skewed concrete bridge: 1) twelve types of seismic isolation devices are considered based on two different design parameters 2) fragility functions of a three-span bridge with and without seismic isolation devices are analytically evaluated based on 3D nonlinear incremental dynamic analyses which seismic input consists of 20 selected ground motions. The optimum combinations of isolation device design parameters are identified comparing, for different limit states, the performance of 1) the Seismic Isolated Bridges (SIB) and 2) Not Seismic Isolated Bridge (NSIB) designed according to the AASHTO standards.

A Low Insertion-Loss, High-Isolation Switch Based on Single Pole Double Throw for 2.4GHz BLE Applications

  • Truong, Thi Kim Nga;Lee, Dong-Soo;Lee, Kang-Yoon
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.5 no.3
    • /
    • pp.164-168
    • /
    • 2016
  • A low insertion-loss, high-isolation switch based on single pole double throw (SPDT) for a 2.4GHz Bluetooth low-energy transceiver is presented in this paper. In order to increase isolation, the body floating technique is implemented. Based on characteristics whereby the ratio of the sizes of the shunt and the series transistors significantly affect the performance of the switches, the device sizes are optimized. A simple matching network is also designed to enhance the insertion loss. Thus, the SPDT switch has high isolation and low insertion loss without increasing the complexity of the circuit. The proposed SPDT is designed and simulated in a complementary metal-oxide semiconductor 65nm process. The switch has a $530{\mu}m{\times}270{\mu}m$ area and achieves 0.9dB, 1.78dB insertion loss and 40dB, 41dB isolation of transmission, reception modes, respectively.

Seismic Performance and Vibration Control of Urban Over-track High-rise Buildings

  • Ying, Zhou;Rui, Wang;Zengde, Zhang
    • International Journal of High-Rise Buildings
    • /
    • v.11 no.3
    • /
    • pp.207-219
    • /
    • 2022
  • During the structural design of urban over-track high-rise buildings, two problems are most likely encountered: the abrupt change of story stiffness between the podium and the upper towers, as well as the demand for train-induced vibration control. Traditional earthquake-resistant structures have to be particularly designed with transfer stories to meet the requirement of seismic control under earthquakes, and thus horizontal seismic isolation techniques are recommended to solve the transfer problem. The function of mitigating the vertical subway-induced vibration can be integrated into the isolation system including thick rubber bearings and 3D composite vibration control devices. Engineering project cases are presented in this paper for a more comprehensive understanding of the engineering practice and research frontiers of urban over-track high-rise buildings in China.

Epitaxial Layer Design for High Performance GaAs pHEMT SPDT MMIC Switches

  • Oh, Jung-Hun;Mun, Jae-Kyoung;Rhee, Jin-Koo;Kim, Sam-Dong
    • ETRI Journal
    • /
    • v.31 no.3
    • /
    • pp.342-344
    • /
    • 2009
  • From a hydrodynamic device simulation for the pseudomorphic high electron mobility transistors (pHEMTs), we observe an increase of maximum extrinsic transconductance and a decrease of source-drain capacitances. This gives rise to an enhancement of the switching speed and isolation characteristics as the upper-to-lower planar-doping ratios (UTLPDR) increase. On the basis of simulation results, we fabricate single-pole-double-throw transmitter/receiver monolithic microwave integrated circuit (MMIC) switches with the pHEMTs of two different UTLPDRs (4:1 and 1:2). The MMIC switch with a 4:1 UTLPDR shows about 2.9 dB higher isolation and approximately 2.5 times faster switching speed than those with a 1:2 UTLPDR.

  • PDF

Miniature Staircase-Shaped Wideband MIMO Antenna with Excellent Isolation, Compliant to the SAR Standard (SAR규격을 만족하는 우수한 격리도의 소형 계단구조 광대역 MIMO 안테나)

  • Kahng, Kyungseok;Yang, In-Kyu;Kahng, Sungtek
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.10
    • /
    • pp.1413-1420
    • /
    • 2013
  • This paper proposes a novel compact MIMO antenna which has miniaturized radiators and their row correlation coefficient, working for the LTE mobile communication, and its SAR is observed. Each of the proposed radiators has a shape of staircase and the bandwidth is twice larger than the conventional PIFA as 600MHz(21%) in 2.5 GHz - 3.15 GHz. And the area of the radiators is $16.5mm{\times}9.7mm$ proper for a handheld device. Also, by adding a planar mushroom decoupling structure between the radiators, the isolation is improved. The design has been carried out using the commercial full-wave time-domain EM solver and the finalized MIMO antenna has the return loss less than -10 dB in the LTE band, the isolation better than 20 dB and the efficiency more than 90% with the gain of 4.3 dB. Regarding the SAR of the antenna, it is observed that the average SAR value of 1g is estimated as 1.37W/Kg, which is lower than the SAR standard.

Development and experimental study on cable-sliding modular expansion joints

  • Gao, Kang;Yuan, Wan C.;Dang, Xin Z.
    • Structural Engineering and Mechanics
    • /
    • v.61 no.6
    • /
    • pp.795-806
    • /
    • 2017
  • According to the characteristics of continuous beam bridges, the relative displacement is too large to collision or even girder falling under earthquakes. A device named Cable-sliding Modular Expansion Joints(CMEJs) that can control the relative displacement and avoid collision under different ground motions is proposed. Working principle and mechanical model is described. This paper design the CMEJs, establish the restoring force model, verify the force model of this device by the pseudo-static tests, and describe and analyze results of the tests, and then based on a triple continuous beam bridge that has different heights of piers, a 3D model with or without CMEJs were established under Conventional System (CS) and Seismic Isolation System (SIS). The results show that this device can control the relative displacement and avoid collisions. The combination of isolation technology and CMEJs can be more effective to achieve both functions, but it need to take measures to prevent girder falling due to the displacement between pier and beam under large earthquakes.

Study on Improvement of the Array Antenna Performance by Isolation Enhancement (격리도 향상을 통한 배열안테나의 성능개선 연구)

  • Park, Minseo;Lee, Jae-Gon;Lee, Jeong-Hae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.3
    • /
    • pp.229-238
    • /
    • 2016
  • In this paper, we have studied isolation enhancement using a suppression of surface wave to improve performance of array antenna. To reduce isolation between elements of array antenna, perfect magnetic conductor(PMC) and SOFT-surface is designed and located at center of ground plane, isolation and gain is simulated by commercial full wave simulator(HFSS). As a result, isolation of more than 40 dB and gain improvement of 2.2 dBi are obtained at E-plane array in case of both PMC and SOFT-surface. At H-plane array, air coupling is dominant compared to coupling by surface wave. It is conclude that this study is useful for design of compact array antenna and performance improvement of array antenna.

An IPD Based 2.5 GHz Power Divider for WiMax Applications

  • Maharjan, Ram Krishna;Kim, Nam-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.50-51
    • /
    • 2009
  • This paper presents integrated passive device (IPD) based on Wilkinson power divider. The simulated 2-way power divider has the insertion loss of 3.123 dB, output isolation of -24.576 dB, input return loss of 26.415 dB, and output return loss of 33.478 dB. The power divider is based on IPD process design simulation at 2.5 GHz for WiMAX (Worldwide Interoperability for Microwave Access) applications. The chip size of power divider is $1\;\times\;1.2\;mm^2$, which is under fabrication.

  • PDF

High-Isolation SPDT RF Switch Using Inductive Switching and Leakage Signal Cancellation

  • Ha, Byeong Wan;Cho, Choon Sik
    • Journal of electromagnetic engineering and science
    • /
    • v.14 no.4
    • /
    • pp.411-414
    • /
    • 2014
  • A switch is one of the most useful circuits for controlling the path of signal transmission. It can be added to digital circuits to create a kind of gate-level device and it can also save information into memory. In RF subsystems, a switch is used in a different way than its general role in digital circuits. The most important characteristic to consider when designing an RF switch is keeping the isolation as high as possible while also keeping insertion loss as low as possible. For high isolation, we propose leakage signal cancellation and inductive switching for designing a singlepole double-throw (SPDT) RF switch. By using the proposed method, an isolation level of more than 23 dB can be achieved. Furthermore, the heterojunction bipolar transistor (HBT) process is used in the RF switch design to keep the insertion loss low. It is demonstrated that the proposed RF switch has an insertion loss of less than 2 dB. The RF switch operates from 1 to 8 GHz based on the $0.18-{\mu}m$ SiGe HBT process, taking up an area of $0.3mm^2$.