• Title/Summary/Keyword: 3D cone beam CT image

Search Result 38, Processing Time 0.025 seconds

3-D Inverse Radon Transform by Use of Tree-Structured Filter Bank

  • Morikawa, Yoshitaka;Murakami, Junichi
    • Proceedings of the IEEK Conference
    • /
    • 2002.07a
    • /
    • pp.184-187
    • /
    • 2002
  • Two-dimensional (2-D) X-ray computerized tomography (CT) equipments are widely used in industrial and medical fields, and nowadays studies on reconstruction algorithm for 3-D cone-beam acquisition systems are active for better utilization. The authors recent-By have proposed a fast reconstruction aigorithm using tree-structured filter bank for 2-D C1, and shown the algorithm is applicable to an approximate reconstruction of 3-D CT. For exact 3-D CT reconstruction, however, we have to backproject 1-D signal into 3-D space. This paper proposes a fast implementation method for this back-projection by use of tree-structured filter bank. and shows the proposed method works approximately 700 times faster than the direct one with almost same reconstruction image quality.

  • PDF

Development of a Micro-CT System for Small Animal Imaging (소 동물 촬영을 위한 Micro-CT의 개발)

  • Sang Chul Lee;Ho Kyung Kim;In Kon Chun;Myung Hye Cho;Min Hyoung Cho;Soo Yeol Lee
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.2
    • /
    • pp.97-102
    • /
    • 2004
  • We developed an x-ray cone-beam micro computed tomography (micro-CT) system for small-animal imaging. The micro-CT system consists of a 2-D flat-panel x-ray detector with a field-of-view (FOV) of 120${\times}$120 mm2, a micro-focus x-ray source, a scan controller and a parallel image reconstruction system. Imaging performances of the micro-CT system have been evaluated in terms of contrast and spatial resolution. The minimum resolvable contrast has been found to be less than 36 CT numbers at the dose of 95 mGy and the spatial resolution about 14 lp/mm. As small animal imaging results, we present high resolution 3-D images of rat organs including a femur, a heart and vessels. We expected that the developed micro-CT system can be greatly used in biomedical studies using small animals.

On-line Image Guided Radiation Therapy using Cone-Beam CT (CBCT) (콘빔CT (CBCT)를 이용한 온라인 영상유도방사선치료 (On-line Image Guided Radiation Therapy))

  • Bak, Jin-O;Jeong, Kyoung-Keun;Keum, Ki-Chang;Park, Suk-Won
    • Radiation Oncology Journal
    • /
    • v.24 no.4
    • /
    • pp.294-299
    • /
    • 2006
  • $\underline{Purpose}$: Using cone beam CT, we can compare the position of the patients at the simulation and the treatment. In on-line image guided radiation therapy, one can utilize this compared data and correct the patient position before treatments. Using cone beam CT, we investigated the errors induced by setting up the patients when use only the markings on the patients' skin. $\underline{Materials\;and\;Methods}$: We obtained the data of three patients that received radiation therapy at the Department of Radiation Oncology in Chung-Ang University during August 2006 and October 2006. Just as normal radiation therapy, patients were aligned on the treatment couch after the simulation and treatment planning. Patients were aligned with lasers according to the marking on the skin that were marked at the simulation time and then cone beam CTs were obtained. Cone beam CTs were fused and compared with simulation CTs and the displacement vectors were calculated. Treatment couches were adjusted according to the displacement vector before treatments. After the treatment, positions were verified with kV X-ray (OBI system). $\underline{Results}$: In the case of head and neck patients, the average sizes of the setup error vectors, given by the cone beam CT, were 0.19 cm for the patient A and 0.18 cm for the patient B. The standard deviations were 0.15 cm and 0.21 cm, each. On the other hand, in the case of the pelvis patient, the average and the standard deviation were 0.37 cm and 0.1 cm. $\underline{Conclusion}$: Through the on-line IGRT using cone beam CT, we could correct the setup errors that could occur in the conventional radiotherapy. The importance of the on-line IGRT should be emphasized in the case of 3D conformal therapy and intensity-modulated radiotherapy, which have complex target shapes and steep dose gradients.

Radiologic study of the healing process of the extracted socket of beagle dogs using cone beam CT (Cone beam CT를 이용한 비글견 발치창 치유과정에 대한 방사선학적 연구)

  • Choi, Dong-Hoon;Lee, Wan;Kim, De-Sok;Lee, Byung-Do
    • Imaging Science in Dentistry
    • /
    • v.39 no.1
    • /
    • pp.19-25
    • /
    • 2009
  • Purpose: To longitudinally observe the healing process of extracted socket and the alterations of the residual ridge in healthy adult dogs using cone beam CT (CBCT). Materials and Methods: The mandibular premolars of two beagle dogs were removed and the extraction sites were covered with the gingival tissue. CBCTs (3D X-ray CT scanner, Alphard vega, Asahi Co.) were taken at baseline and at 1 week interval for 12 weeks. Radiographic density of extracted wounds was measured on normalized images with a custom-made image analysis program. The amount of alveolar crestal resorption after the teeth extraction was measured with a reformatted three-dimensional image using CBCT. Bony healing pattern of extracted wound of each group was also longitudinally observed and analyzed. Results: Dimensional changes occurred during the first 6 weeks following the extraction of dogs' mandibular premolars. The reduction of the height of residual ridge was more pronounced at the buccal than at the lingual aspect of the extraction socket. Radiographic density of extracted wounds increased by week 4, but the change in density stabilized after week 6. New bone formation was observed at the floor and the peripheral side of extracted socket from week 1. The entrance of extracted socket was sealed by a hard-tissue bridge at week 5. Conclusion: The healing process of extracted wound involved a series of events including new bone formation and residual ridge resorption.

  • PDF

A Study on the Availability of the On-Board Imager(OBI) and Cone-Beam CT(CBCT) in the Verification of Patient Set-up (온보드 영상장치(On-Board Imager) 및 콘빔CT(CBCT)를 이용한 환자 자세 검증의 유용성에 대한 연구)

  • Bak, Jino;Park, Sung-Ho;Park, Suk-Won
    • Radiation Oncology Journal
    • /
    • v.26 no.2
    • /
    • pp.118-125
    • /
    • 2008
  • Purpose: On-line image guided radiation therapy(on-line IGRT) and(kV X-ray images or cone beam CT images) were obtained by an on-board imager(OBI) and cone beam CT(CBCT), respectively. The images were then compared with simulated images to evaluate the patient's setup and correct for deviations. The setup deviations between the simulated images(kV or CBCT images), were computed from 2D/2D match or 3D/3D match programs, respectively. We then investigated the correctness of the calculated deviations. Materials and Methods: After the simulation and treatment planning for the RANDO phantom, the phantom was positioned on the treatment table. The phantom setup process was performed with side wall lasers which standardized treatment setup of the phantom with the simulated images, after the establishment of tolerance limits for laser line thickness. After a known translation or rotation angle was applied to the phantom, the kV X-ray images and CBCT images were obtained. Next, 2D/2D match and 3D/3D match with simulation CT images were taken. Lastly, the results were analyzed for accuracy of positional correction. Results: In the case of the 2D/2D match using kV X-ray and simulation images, a setup correction within $0.06^{\circ}$ for rotation only, 1.8 mm for translation only, and 2.1 mm and $0.3^{\circ}$ for both rotation and translation, respectively, was possible. As for the 3D/3D match using CBCT images, a correction within $0.03^{\circ}$ for rotation only, 0.16 mm for translation only, and 1.5 mm for translation and $0.0^{\circ}$ for rotation, respectively, was possible. Conclusion: The use of OBI or CBCT for the on-line IGRT provides the ability to exactly reproduce the simulated images in the setup of a patient in the treatment room. The fast detection and correction of a patient's positional error is possible in two dimensions via kV X-ray images from OBI and in three dimensions via CBCT with a higher accuracy. Consequently, the on-line IGRT represents a promising and reliable treatment procedure.

Three-dimensional soft tissue analysis for the evaluation of facial asymmetry in normal occlusion individuals

  • Hwang, Hyeon-Shik;Yuan, Donghui;Jeong, Kweon-Heui;Uhm, Gi-Soo;Cho, Jin-Hyoung;Yoon, Sook-Ja
    • The korean journal of orthodontics
    • /
    • v.42 no.2
    • /
    • pp.56-63
    • /
    • 2012
  • Objective: To identify the right and left difference of the facial soft tissue landmarks three-dimensionally from the subjects of normal occlusion individuals. Materials and Methods: Cone-beam computed tomography (CT) scans were obtained in 48 normal occlusion adults (24 men, 24 women), and reconstructed into 3-dimensional (3D) models by using a 3D image soft ware. 3D position of 27 soft tissue landmarks, 9 midline and 9 pairs of bilateral landmarks, were identified in 3D coordination system, and their right and left differences were calculated and analyzed. Results: The right and left difference values derived from the study ranged from 0.6 to 4.6 mm indicating a high variability according to the landmarks. In general, the values showed a tendency to increase according to the lower and lateral positioning of the landmarks in the face. Overall differences were determined not only by transverse differences but also by sagittal and vertical differences, indicating that 3D evaluation would be essential in the facial soft tissue analysis. Conclusions: Means and standard deviations of the right and left difference of facial soft tissue landmarks derived from this study can be used as the diagnostic standard values for the evaluation of facial asymmetry.

Surgical stent for dental implant using cone beam CT images (콘빔형 전산화단층영상을 이용한 치과임플란트 식립유도장치 개발)

  • Choi, Hyung-Soo;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.40 no.4
    • /
    • pp.171-178
    • /
    • 2010
  • Purpose : The purpose of this study is to develop a surgical stent for dental implant procedure that can be easily applied and affordable by using cone beam computerized tomography (CBCT). Materials and Methods : Aluminum, Teflon-PFA (perfluoroalkoxy), and acetal (polyoxymethylene plastic) were selected as materials for the surgical stent. Among these three materials, the appropriate material was chosen using the CBCT images. The surgical stent, which could be easily placed into an oral cavity, was designed with chosen material. CBCT images of the new surgical stent on mandible were obtained using Alphard-3030 dental CT system (Asahi Roentgen Co., Ltd., Kyoto, Japan). The point of insertion was prescribed on the surgical stent with the multiplanar reconstruction software of OnDemand3D (CyberMed Inc., Seoul, Korea). Guide holes were made at the point of insertion on the surgical stent using newly designed guide jig. CBCT scans was taken for the second time to verify the accuracy of the newly designed surgical stent. Results : Teflon-PFA showed radiologically excellent image characteristics for the surgical stent. High accuracy and reproducibility of implantation were confirmed with the surgical stent. Conclusion : The newly designed surgical stent can lead to the accurate implantation and achieve the clinically predictable result.

Usability of 2D/2D Match for Image Guided Radiotherapy (IGRT) of Prostate Cancer with Fiducial Markers (전립선 암 환자의 영상유도 방사선 치료 시 Fiducial Marker를 이용한 2D/2D Match의 유용성에 대한 연구)

  • Bae, Sun-Myung;Yang, Oh-Nam;Song, Heung-Kwon;Back, Geum-Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.1
    • /
    • pp.19-24
    • /
    • 2010
  • Purpose: To study the efficacy of marker match with using kilovoltage (KV) X-ray among multiple image guidance that referring tree fiducial marker in radiation therapy for prostate cancer patients. Materials and Methods: KV two-dimantional images (anterior-posterior, right-left) and cone-beam CT volumetric images were acquired after setup for patients with three fiducial markers. Compare the position of the fiducial marker of reference plan computed tomography (CT) and of KV, CBCT images; then decide the shift score of X, Y, and Z. This study executed 5 times on 10 patients and analyzed the shift value. Results: In the radiation therapy using fiducial marker, The function of marker match showed the same direction tendency as the CBCT, and showed X, Y, Z difference of about 0.6, 0.7, and 0.8 (unit: mm). Conclusion: Comparing to this, the result of shift value using 2D marker match showed less than 1.0 mm difference. The function of marker match is considered more useful in time-wise and effective dose rather than CBCT. Therefore, Both methods are used to treat patients for prostate cancer.

  • PDF

Evaluation of Every Other Day - Cone Beam Computed Tomography in Image Guided Radiation Therapy for Prostate Cancer (전립선암의 영상유도방사선치료 시 격일 콘빔 CT 적용의 유용성 평가)

  • Park, Byoung Suk;Ahn, Jong Ho;Kim, Jong Sik;Song, Ki Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.289-295
    • /
    • 2014
  • Purpose : Cone Beam Computed Tomography(CBCT) in Image Guided Radiation Therapy(IGRT), Set-up error can be reduced but exposure dose of the patient due to CBCT will increase. Through this study, we are to evaluate by making a scenario with the implementation period of CBCT as every other day. Materials and Methods : Of prostate cancer patients, 9 patients who got a Intensity Modulated Radiation Therapy(IMRT) with CBCT in IGRT were analyzed. Based on values corrected by analyzing set-up error by using CBCT every day during actual treatment, we created a scenario that conducts CBCT every other day. After applying set-up error values of the day not performing CBCT in the scenario to the treatment planning system(Pinnacle 9.2, Philips, USA) by moving them from the treatment iso-center during actual treatment, we established re-treatment plan under the same conditions as actual treatment. Based on this, the dose distribution of normal organs and Planning Target Volume(PTV) was compared and analyzed. Results : In the scenario that performs CBCT every other day based on set-up error values when conducting CBCT every day, average X-axis : $0.2{\pm}0.73mm$, Y-axis : $0.1{\pm}0.58mm$, Z-axis : $-1.3{\pm}1.17mm$ difference was shown. This was applied to the treatment planning to establish re-treatment plan and dose distribution was evaluated and as a result, Dmean : -0.17 Gy, D99% : -0.71 Gy of PTV difference was shown in comparison with the result obtained when carrying out CBCT every day. As for normal organs, V66 : 1.55% of rectal wall, V66 : -0.76% of bladder difference was shown. Conclusion : In case of a CBCT perform every other day could reduce exposure dose and additional treatment time. And it is thought to be able to consider the application depending on the condition of the patient because the difference in the dose distribution of normal organs, PTV is not large.

Anthropometric analysis of maxillary anterior buccal bone of Korean adults using cone-beam CT

  • Lee, Seung-Lok;Kim, Hee-Jung;Son, Mee-Kyoung;Chung, Chae-Heon
    • The Journal of Advanced Prosthodontics
    • /
    • v.2 no.3
    • /
    • pp.92-96
    • /
    • 2010
  • PURPOSE. The aim of this study was to evaluate the thickness of buccal and palatal alveolar bone and buccal bony curvature below root apex in maxillary anterior teeth of Korean adults using Cone-beam CT images. MATERIALS AND METHODS. The 3D image was reconstructed with dicom file obtained through CBCT from 20 - 39 year old Korean subjects (n = 20). The thickness of buccal and palatal plate, root diameter, the buccal bony curvature angle below root apex and the distance from root apex to the deepest point of buccal bony curvature were measured on maxillary anterior teeth area using OnDemand3D program. RESULTS. Mean thickness of buccal plate 3 mm below CEJ was $0.68{\pm}0.29\;mm$ at central incisor, $0.76{\pm}0.59\;mm$ at lateral incisor, and $1.07{\pm}0.80\;mm$ at canine. Mean thickness of palatal plate 3 mm below CEJ was $1.53{\pm}0.55\;mm$ of central incisor, $1.18{\pm}0.66\;mm$ of lateral incisor, $1.42{\pm}0.77\;mm$ of canine. Bucco-lingual diameter 3 mm below CEJ was $5.13{\pm}0.37\;mm$ of central incisor, $4.58{\pm}0.46\;mm$ of lateral incisor, and $5.93{\pm}0.47\;mm$ of canine. Buccal bony curvature angle below root apex was $134.7{\pm}17.5^{\circ}$ at central incisor, $151.0{\pm}13.9^{\circ}$ at lateral incisor, $153.0{\pm}9.5^{\circ}$ at canine. Distance between root apex and the deepest point of buccal bony curvature of central incisor was $3.67{\pm}1.28\;mm$ at central incisor, $3.90{\pm}1.51\;mm$ at lateral incisor, and $5.13{\pm}1.70\;mm$ at canine. CONCLUSION. Within the limitation of this study in Korean adults, the thickness of maxillary anterior buccal plate was very thin within 1mm and the thickness of palatal plate was thick, relatively. The buccal bony curvature below root apex of maxillary central incisor was higher than that of lateral incisor and canine and it seems that the buccal bony plate below root apex of central incisor is most curved.