• Title/Summary/Keyword: 3D body measuring

Search Result 135, Processing Time 0.031 seconds

Correlations between Gastroscopy Results and Zone-5 Data from the 7-zone-Diagnostic System (7구역진단기의 5구역 정보와 위내시경 소견의 상관성에 관한 연구)

  • Jung, Jung Da;Im, Jeong Gyun;Lee, Hyung Geol;Yook, Tae Han;Kim, Jong Uk
    • Journal of Acupuncture Research
    • /
    • v.30 no.1
    • /
    • pp.1-11
    • /
    • 2013
  • Objectives : The 7-zone-diagnostic system is a device for predetermining bodily locations by measuring the energy of the living body. The purpose of this study is to examine correlations between gastroscopy results and zone-5 data from the 7-zone-diagnostic system. Methods : This study was carried out with data from gastroscopy procedures. It involved 115 patients who had been diagnosed with gastritis, esophagitis, or gastric ulcers. These patients were divided into three groups according to the different patterns of zone-5 factors AA, FL2 and FL1. Group A was made up of patients for whom the red bar graph of zone-5 was higher than the normal range for factor AA. Group B was made up of patients for whom the red bar graph of zone-5 was within the normal range for factor AA. Group C was made up of patients for whom the red bar graph of zone-5 was lower than the normal range for factor AA. Group D E and F were made up of same way as group A B and C for factor FL2. Group G H and I were made up of same way as group A B and C for factor FL1. After the collection of gastroscopy results and data on zone-5 from the 7-zone-diagnostic system, the data was analyzed statistically. Results : 1. Group D had a higher ratio of medication than group E, and this result was statistically significant. 2. Group D G had a higher ratio of medication than group E G and group E H, and this result was statistically significant. 3. Group G had a higher ratio of esophagitis than group H, and this result was statistically significant. 4. A Group B H had a higher ratio of esophagitis than group B G, group C G, and group C H, and this result was statistically significant. 5. The medication group had a high score on the function index than the non-medication group, and this result was statistically significant. Conclusions : This study suggests that there is a slight correlation between gastroscopy results and zone-5 data from the 7-zone-diagnostic system. The research resulted in significant data that are helpful for diagnosing digestive system problems through the use of the 7-zone-diagnostic system.

An Optimization Method of Measuring Heart Position in Dynamic Myocardial Perfusion SPECT with a CZT-based camera (동적 심근관류 SPECT에서 심장의 위치 측정방법에 대한 고찰)

  • Seong, Ji Hye;Lee, Dong Hun;Kim, Eun Hye;Jung, Woo Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.75-79
    • /
    • 2019
  • Purpose Cadmium-zinc-telluride (CZT) camera with semiconductor detector is capable of dynamic myocardial perfusion SPECT for coronary flow reserve (CFR). Image acquisition with the heart positioned within 2 cm in the center of the quality field of view (QFOV) is recommended because the CZT detector based on focused multi-pinhole collimators and is stationary gantry without rotation. The aim of this study was to investigate the optimal method for measuring position of the heart within the center of the QFOV when performing dynamic myocardial perfusion SPECT with the Discovery NM 530c camera. Materials and Methods From June to September 2018, 45 patients were subject to dynamic myocardial perfusion SPECT with D530c. For accurate heart positioning, the patient's heart was scanned with a mobile ultrasound and marked at the top of the probe where the mitral valve (MV) was visible in the parasternal long-axis view (PLAX). And, the marked point on the patient's body matched with the reference point indicated CZT detector in dynamic stress. The heart was positioned to be in the center of the QFOV in rest. The coordinates of dynamic stress and rest were compared statistically. Results The coordinates of the dynamic stress using mobile ultrasound and those taken of the rest were recorded for comparative analysis with regard to the position of the couch and analyzed. There were no statistically significant differences in the coordinates of Table in & out, Table up & down, and Detector in & out (P > 0.05). The difference in distance between the 2 groups was measured at $0.25{\pm}1.00$, $0.24{\pm}0.96$ and $0.25{\pm}0.82cm$ respectively, with no difference greater than 2 cm in all categories. Conclusion The position of the heart taken using mobile ultrasound did not differ significantly from that of the center of the QFOV. Therefore, The use of mobile ultrasound in dynamic stress will help to select the correct position of the heart, which will be effective in clinical diagnosis by minimizing the image quality improvement and the patient's exposure to radiation.

Relationship between Carotid Intima Media Thickness and Appendicular Skeletal Muscle Index according to Gender (성별에 따른 경동맥 내중막두께와 사지근육량지수와의 관련성)

  • Yang, Sung-Hee;Lee, Hee-Jeong
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.309-317
    • /
    • 2022
  • It is reported that social distancing caused by the corona pandemic has resulted in a decrease in physical activity, and a decrease in muscle mass due to this increases the risk of vascular disease. Therefore, in this study, the risk of carotid intima media thickness was evaluated by measuring the thickness of CIMT, and the differences in variables according to gender were analyzed. From January 2022 to May 2022, a total of 220 people (121 males, 99 females) who performed blood tests, carotid ultrasound, and body composition analysis among those who visited the health check-up center of Busan H Hospital were included in this study. Significant differences in risk factors according to gender were analyzed using the chi-square test. The cut-off values of variables that can predict the risk of carotid intima media thickness were calculated, and the accuracy was evaluated by calculating the area under the curve, sensitivity, and specificity. As a result of the difference analysis, the higher the total cholesterol in men and the appendicular skeletal muscle index in women, the higher the risk of carotid intima media thickness. The cut-off value for predicting the risk of carotid intima media thickness was calculated to be greater than 199 mg/dL of total cholesterol in the male group and less than 5.9 kg/m2 of the appendicular skeletal muscle index in the female group. As a result of this study, the higher the total cholesterol in men and the lower the appendicular skeletal muscle index in women, the higher the risk of increased CIMT. Therefore, in women, the appendicular skeletal muscle index is expected to serve as an indicator to predict and prevent vascular changes at an early stage.

Effects of Foot Bath and Spray Application of Peppermint and Grapefruit Essential Oils on Lower Extremity Edema, Pain, and Fatigue (페퍼민트, 그레이프후룻 에센셜 오일을 이용한 족욕 또는 스프레이 적용이 하지부종, 통증 및 피로에 미치는 효과)

  • Han, Ari;Kim, Juri;Hur, Myung-Haeng
    • Journal of the Korea Convergence Society
    • /
    • v.13 no.1
    • /
    • pp.375-386
    • /
    • 2022
  • Work involving standing or walking for a long time can cause swelling, pain, and fatigue in the lower extremities due to the effect of gravity on the circulation of the body. This study aimed to confirm the effects of aromatherapy essential oils, as a complementary and alternative therapy, on lower extremity edema, pain, and fatigue when applied as a foot bath or spray. The study was conducted after daytime work over two consecutive days on nurses who volunteered at the E University Hospital in D Metropolitan city between 15 August 2018 and 11 October 2018. This randomized controlled study. The foot bath group received a foot bath in 9 L of water containing 0.5 ml of essential oil blended with grapefruit and peppermint in a 1:1 ratio. The spray group received the same solution in 3% dilution in the form of a spray. Edema was assessed by measuring calf and ankle circumference, while pain and fatigue were evaluated using a numerical rating scale. Data were analyzed by ANOVA and repeated-measures ANOVA. The calf circumference in the foot bath and spray groups significantly reduced compared to that in the control group (F = 14.053, p <.001) after the interventions. Lower extremity pain (F = 42.497, p < .001) and fatigue (F = 20.641, p < .001) also significantly reduced in the foot bath and spray groups compared to those in the control group after the interventions. Foot bath is recommended to relieve swelling and pain in the lower extremities, and aroma spray is highly recommended considering the ease of application.

Ultrasound Imaging of Normal Cardiac Structures with Convex Scanner in Puppies (강아지에서 컨벡스스캐너를 이용한 정상적인 심장구조물의 초음파상)

  • Jeong Soon-wuk;Park Hee-myung;Han Sook-hee;Yoon Jung-hee;Han Hong-ryul
    • Journal of Veterinary Clinics
    • /
    • v.11 no.2
    • /
    • pp.529-537
    • /
    • 1994
  • Sector scanner which has a conical end is used to image through the intercostal space because heart is protected by the ribs. Cardiac data published all around the world were also obtained by sector scanner. Although scanners being used in every small animal practice and animal hospital at college in Korea include convex ape and linear type, linear type is not appropriate f3r cardiac scan because of a wide contact surface. The purpose of this study is to establish ultrasonographic images of normal cardiac structures by measuring shape, size of reflectable cardiac structure according to restraint position in scanning normal heart of the puppies with 6.5 MHz convex scanner(SonoAce 4500, Medison, Korea) used in our veterinary teaching hospital, Seoul national university. Seventeen male and female puppies considered having healthy hear by X-ray and clinical examination are used feom April to July 1994. Scanning point selection of probe head and the distinction of imaged cardiac structures were accomplished by necropsy and cardiac scanning performed through thoracotomy under general anesthesia. At 10 o'clock position of transducer(at an angle of 30$^{\circ}$ between imaginary line from elbow joint to 3rd sternum and probe head, 60$^{\circ}$ from body surface, 4th intercostal space of right thorax) with the marker of scanner toward the head of dogs right atrium, left atrium and left ventricle were observed in 2, 3, 4, 5 intercostal space(2cm from the sternum) of experimental dog positioned ventrodorsally under general anesthesia. Under these conditions, the numerical values of imaged diastolic hear are as follows : the distance from skin to apex(mean$\pm$S.D) 47.53$\pm$6.94mm, thickness of left ventricular wall 6.00$\pm$1.60mm, length of left ventricle 16.27$\pm$5.31mm, width of left ventricle 15,33$\pm$4.25mm, length of left atrium 12.33$\pm$3.82mm, width of left atrium 11. 33$\pm$3.94mm, length of right atrium 1.00$\pm$2.41mm, width of right atrium 11.21$\pm$2.76mm and the area of left ventricle 270.92$\pm$109.81mm$^2$, area of left atrium 98.00$\pm$41.08mm$^2$, area of right atrium 62.75$\pm$21.04mm$^2$.

  • PDF

Excessive Daytime Sleepiness Case Confounding with Thyrotoxicosis (과도한 주간 졸림과 탈력발작을 주소로 내원한 환자에서 발견된 갑상선 중독증)

  • Chung, Jae-Kyung;Kim, Eui-Joong
    • Sleep Medicine and Psychophysiology
    • /
    • v.18 no.1
    • /
    • pp.40-44
    • /
    • 2011
  • Narcolepsy is a sleep disorder, which is characterized by excessive daytime sleepiness (EDS) that is typically associated with cataplexy, sleep fragmentation and other REM sleep-related phenomenon such as sleep paralysis and hypnagogic hallucination. Narcoleptic symptoms can be developed from various medical or neurological disorders. A 17-year-old male patient admitted for the evaluation of EDS which started three-month ago. He slept more than 18 hours a day with cataplexy and hypnagogic hallucination. He was obese with body mass index (BMI) of 30.4 kg/$m^2$. After admission he was newly diagnosed to the thyrotoxicosis. T3 391.2 ng/dL (60-181), free T4 4.38 ng/dL (0.89-1.76), TSH <0.01 ${\mu}IU$/mL (0.35-5.5) were measured. His pulse rate ranged 70-90 beats per minute and blood pressure ranged 150/100-120/70 mmHg. Polysomnography revealed many fragmentations in sleep with many positional changes (81 times/h). Sleep onset latency was 33.5 min, sleep efficiency was 47.9%, and REM latency from sleep onset was delayed to 153.6 min. REM sleep percent was increased to 27.1%. Periodic limb movement index was 13.4/h. In the multiple sleep latency test (MSLT), average sleep latency was 0.4 min and there were noted 3 SOREMPs (Sleep Onset REM sleep period) on 5 trials. We couldn't discriminate the obvious sleep-wake pattern in the actigraph and his HLA DQB1 $^*0602$ type was negative. His thyroid function improved following treatment with methimazole and propranolol. Vital sign maintained within normal range. Cataplexy was controlled with venlafaxine 75 mg. Subjective night sleep continuity and PLMS were improved with clonazepam 0.5 mg, but the EDS were partially improved with modafinil 200-400 mg. Thyrotoxicosis might give confounding role when we were evaluating the EDS, though sleep fragmentation was one of the major symptoms of narcolepsy, but enormous amount of it made us think of the influence of thyroid hormone. The loss of sleep-wake cycle, limited improvement of EDS to the stimulant treatmen, and the cataplexy not supported by HLA DQB1 $^*0602$ should be answered further. We still should rule out idiopathic hypersomnia and measuring CSF hypocretin level would be helpful.

Development of Analytical Methods for Micro Levels of Naphthalene and TNT in Groundwater by HPLC-FLD and MSD (HPLC-FLD와 MSD를 이용한 지하수 중 나프탈렌 및 TNT의 미량 분석법 개발)

  • Park, Jong-Sung;Oh, Je-Ill;Jeong, Sang-Jo;Choi, Yoon-Dae;Her, Nam-Guk
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.6
    • /
    • pp.35-44
    • /
    • 2009
  • Naphthalene and TNT (2,4,6-trinitrotoluene) are defined by U.S. EPA as possible carcinogenic compounds known to have detrimental effects on the aquatic ecosystem and human body. There are, however, few researches on methods of analyzing micro-levels of naphthalene and TNT dissolved in groundwater. This study introduces and evaluates the newly developed analytical methods of measuring naphthalene and TNT in groundwater by using HPLC-FLD (Fluorescence detector) and MSD (Mass detector). The MDL, LOQ and salt effect of these methods, respectively, are compared with those of conventional methods which use HPLC-UV. For the analysis of naphthalene, HPLC-FLD was set in the maxima wavelength (Ex: 270 nM, Em: 330 nM) obtained from 3D-Fluorescence to be compared with HPLC-UV in 266 nM wavelength. The MDL ($0.3\;{\mu}g/L$) and LOQ ($2.0\;{\mu}g/L$) of naphthalene by using HPLC-FLD were approximately 80 times lower than those analyzed by HPLC-UV (MDL: $23.3\;{\mu}g/L$, LOQ: $163.1\;{\mu}g/L$). HPLC-MSD were used in comparison with HPLC-UV in 230 and 254 nM wavelength for the analysis of TNT. The MDL ($0.13\;{\mu}g/L$) and LOQ ($0.88\;{\mu}g/L$) of TNT analyzed by using HPLC-MSD were approximately 130 times lower than those obtained by using HPLC-UV in 230 nM (MDL: $16.8\;{\mu}g/L$, LOQ: $117.5\;{\mu}g/L$). The chromatogram of TNT analyzed by using HPLC-UV in 230 nM displayed elevated baseline as the concentration of ${NO_3}^-$ increases beyond 21 mg/L, while the analysis using HPLC-MSD did not demonstrate any change in baseline in presence of ${NO_3}^-$ of 63.7 mg/L which is 3.5 times higher than average concentration in groundwater. In conclusion, HPLC-FLD and HPLC-MSD may be used as suitable methods for the analysis of naphthalene and TNT in groundwater and drinking water. These methods can be applied to the monitoring of naphthalene and TNT concentration in groundwater or drinking water.

Pu-erh Tea Powder Preventive Effects on Cisplatin-Induced Liver Oxidative Damage in Wistar Rats

  • Zheng, Xiao-Nan;Wang, Xiao-Wen;Li, Li-Ya;Xu, Zi-Wei;Huang, Hsin-Yi;Zhao, Jin-Sheng;Zhang, Duo;Yin, Xu;Sheng, Jun;Tang, Jin-Tian
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.17
    • /
    • pp.7389-7394
    • /
    • 2014
  • Background: Chemotherapy is one of the major means for control of malignancies, with cisplatin (CDDP) as one of the main agents, widely used for the treatment of various malignant solid tumors. However, prevention of hepatotoxicity from cisplatin is one of the urgent issues in cancer chemotherapy. In this study, we aimed to investigate the effects of pu-erh tea on hepatotoxicity through body weight and tissue antioxidant parameters like, liver coefficient, serum alanine aminotransferase (ALT), serum aspartate aminotransferase (AST), superoxide dismutase (SOD), glutathione peroxidase (GSH-PX), malondialdehyde(MDA) and glutathione (GSH) levels, and light microscopic evaluation by histological findings. Materials and Methods: The rats were randomly divided into five groups: Control (n=10), cisplatin (3 mg/kg p.i., n=10), cisplatin+pu-erh (0.32 g/kg/day i.g., n=10), cisplatin+pu-erh (0.8 g/kg/day i.g., n=10) and cisplatin+pu-erh (1.6 g/kg/day i.g., n=10). Pu-erh tea powder was administrated for 31 consecutive days. The rats were sacrificed at the end on the second day after a single dose of cisplatin treatment for measuring indices. Results: Pu-erh tea powder exhibited a protective effect by decreasing MDA and GSH and increasing the SOD and GSH-PX levels and GSH-PX/MDA ratio in camparison with the control group. Besides, pu-erh tea was also able to alleviate the pathological damage to some extent. Conclusion: Pu-erh tea powder is protective against cisplatin-induced liver oxidative damages, especially at the medium dosage (0.8 g/kg/d).

Estimation of the Possible Age for Using Various Types of Inhaler by In-Check Inspiratory Flow Meter(TM) (In-Check Inspiratory Flow Meter(TM)를 사용하여 추정한 다양한 흡입기구의 사용 가능한 연령)

  • Jung, Kyung Hyun;Kim, Sun Ye;Lee, Jun Ho;Kim, Kye Sung;Jang, Yook;Han, Man Yong
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.2
    • /
    • pp.192-198
    • /
    • 2002
  • Purpose : It is important to select and use kinds of Inhaler appropriate to the age of the patient and severity of symptoms. Several kinds of Inhaler have been developed and recommended according to each inhaler's resistance and usage method. We evaluated the usable age of 4 inhalers (turbulent flow inhalers, multi unit dose inhalers, breath actuated MDI, and autohalers) by measuring peak inspiratory flow(PIF) using $In-Check^{(TM)}$ Inspiratory Flow Meter. Methods : Ninety three patients aged from 3 to 7 years(mean $57{\pm}12.9$ mo.) who had admitted to CHA hospital from July 2000 to April 2001 were enrolled. Study patients were divided into 4 groups according to age : 3-4 years of age(group A, n=31), 4-5 years of age(group B, n=32), 5-6 years of age(group C, n=18), and 6-7 years of age(group D, n=12). Results : Out of total 93 patients, 23(71%), 27(84%), 17(94%) patients of each group A, B, C and all 12 patients of group D could use the 4 types of inhaler through adequated education. In all four groups, height, body weight and age were significantly correlated(P<0.05). Usable age, height and weight of children who can use turbulent flow inhaler(TFI) were each 8 year 7 month old, 144 cm, 32.0 kg, and those of multi unit dose inhaler(MUD) were 2 year 10 month old, 92 cm, 12.0 kg. Also that of breath-actuated MDI were 1 yr 8 months, 83 cm, 8.5 kg and that of autohaler were 2 yr 8 months, 91 cm, 11.0 kg Conclusion : We concluded that the ability to use inhalers correlated with height, weight and age of the patients. Multi unit dose inhalers, Breath actuated MDI and Autohaler are useful after 3 years of age through adequate education.

The study on the scattering ratio at the edge of the block according to the increasing block thickness in electron therapy (전자선 치료 시 차폐블록 두께 변화에 따른 블록 주변 선량에 관한 연구)

  • Park, Zi On;Gwak, Geun Tak;Park, Ju Kyeong;Lee, Seung Hun;Kim, Yang Su;Kim, Jung Soo;Kwon, Hyoung Cheol;Lee, Sun Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.57-65
    • /
    • 2019
  • Purpose: The purpose is to clarify the effect of additional scattering ratio on the edge of the block according to the increasing block thickness with low melting point lead alloy and pure lead in electron beam therapy. Methods and materials: $10{\times}10cm^2$ Shielding blocks made of low melting point lead alloy and pure lead were fabricated to shield mold frame half of applicator. Block thickness was 3, 5, 10, 15, 20 (mm) for each material. The common irradiation conditions were set at 6 MeV energy, 300 MU / Min dose rate, gantry angle of $0^{\circ}$, and dose of 100 MU. The relative scattering ratio with increasing block thickness was measured with a parallel plate type ion chamber(Exradin P11) and phantom(RW3) by varying the position of the shielding block(cone and on the phantom), the position of the measuring point(surface ans depth of $D_{max}$), and the block material(lead alloy and pure lead). Results : When (depth of measurement / block position / block material) was (surface / applicator / pure lead), the relative value(scattering ratio) was 15.33 nC(+0.33 %), 15.28 nC(0 %), 15.08 nC(-1.31 %), 15.05 nC(-1.51 %), 15.07 nC(-1.37 %) as the block thickness increased in order of 3, 5, 10, 15, 20 (mm) respectively. When it was (surface / applicator / alloy lead), the relative value(scattering ratio) was 15.19 nC(-0.59 %), 15.25 nC(-0.20 %), 15.15 nC(-0.85 %), 14.96 nC(-2.09 %), 15.15 nC(-0.85 %) respectively. When it was (surface / phantom / pure lead), the relative value(scattering ratio) was 15.62 nC(+2.23 %), 15.59 nC(+2.03 %), 15.53 nC(+1.67 %), 15.48 nC(+1.31 %), 15.34 nC(+0.39 %) respectively. When it was (surface / phantom / alloy lead), the relative value(scattering ratio) was 15.56 nC(+1.83 %), 15.55 nC(+1.77 %), 15.51 nC(+1.51 %), 15.42 nC(+0.92 %), 15.39 nC(+0.72 %) respectively. When it was (depth of $D_{max}$ / applicator / pure lead), the relative value(scattering ratio) was 16.70 nC(-10.87 %), 16.84 nC(-10.12 %), 16.72 nC(-10.78 %), 16.88 nC(-9.93 %), 16.90 nC(-9.82 %) respectively. When it was (depth of $D_{max}$ / applicator / alloy lead), the relative value(scattering ratio) was 16.83 nC(-10.19 %), 17.12 nC(-8.64 %), 16.89 nC(-9.87 %), 16.77 nC(-10.51 %), 16.52 nC(-11.85 %) respectively. When it was (depth of $D_{max}$ / phantom / pure lead), the relative value(scattering ratio) was 17.41 nC(-7.10 %), 17.45 nC(-6.88 %), 17.34 nC(-7.47 %), 17.42 nC(-7.04 %), 17.25 nC(-7.95 %) respectively. When it was (depth of $D_{max}$ / phantom / alloy lead), the relative value(scattering ratio) was 17.45 nC(-6.88 %), 17.44 nC(-6.94 %), 17.47 nC(-6.78 %), 17.43 nC(-6.99 %), 17.35 nC(-7.42 %) respectively. Conclusions: When performing electron therapy using a shielding block, the block position should be inserted applicator rather than the patient's body surface. The block thickness should be made to the minimum appropriate shielding thickness of each corresponding using energy. Also it is useful that the treatment should be performed considering the influence of scattering dose varying with distance from the edge of block.