• Title/Summary/Keyword: 3D applications

Search Result 2,717, Processing Time 0.027 seconds

An Investigation of the Control of Two-Spotted Spider Mites (Tetranychus urticae Koch) Resistant to Organo-Phosphates (유기인제저항성 점박이응애(Tetranychus urticae Koch)에 관한 연구)

  • Lee Seung Chan;Harrison R. A.
    • Korean journal of applied entomology
    • /
    • v.7
    • /
    • pp.39-51
    • /
    • 1969
  • The study involved determination of resistance levels of spider mites ta argano-phosphates using topical application and slide dip techniques; laboratory serening tests of alternative acaricides using an O/P resistant strain and a field trial of the screened materials. 1. Strains of Tetranychus were from Timaru(TR), Havelock Narth (HNR), Lincaln (LN). Germany (GR, GN). Comparisons of the resistant strains and normal strains at the LD50 and LC50 levels were as follows : (a) Using the topical application tochnique; with Parathian. resistant levels of the GR. TR and HNR strains of T. urticae were respeativuly, 1035. 484 and 452 times as resistant' as the LN strain. (b) Using the slide dip technique; with Phosdrin, resistant of GR, TR and HNR strains of T. urticae were 635, 274 and 266 times greater respeativuly, than the GN strain. 2. The laboratory sereaning tests were carried out far their contact plus stomach and residual effect to assess the toxicities of eleven alternative materials which would be used far control of O/P resistant strain of T. urticae. The acaricide groups represented were 3 organo-chlorines (Spidex, Kelthane and C 8514), 2 nitrophenyls (UC 19786 and Morocide), 2 cyclic carbonates(Eradex and Morestan). I carbamate (UC2004 7A), 1 mixture of carbamate and orano-chlorine and 2 other chemicals (C 8677 and M2527). From all acaricide tested. Kelthane and Morocide were the most effective, folowed by Spidex and M2527. Morestan, C8514. C8677 and RS 143 were intermediate, but Eradex, UC 19786 and UC 20046A were poor. 3, The number of sapmles required for estimation of the population in the field evaluation of acaricidal effects was one giving the highest practical precision. It was decided, after preliminary sampling trials. to use samples of 30 leaves per replicate which gave a $5.7\%$ standard error. 4. In the field trials, Morocide applied at the $0.05\%\;and\; 0.04\%$ a. i. conc. to black currant trees gave excellent control of O/P resistant population of T. urticae for about 12 days, but Morocide 0.025 and Kel thane $0.02\%$ a. i. cone. gave efficient control for about 6 days. In other words. first applications of Kel thane ane Moroeide gave very high degrees of control of O/P resistant population of the two-spotted spider mite. However, the results indicate that secondary application would sometimes be necessary. There was no foliage damage of black Currants and strawberries by either acaricides at the concentrations used. Acknowledgment ... The authors are grateful to: Dr. R. P. pottinger, Senior Lecturer in Agricultural Zoology. Lincoln college. New Zealand. for his helpful assistance in aiding with the organization of thd field work. Department of agriculture officers for mite colonies. Mr. D. A. Slade, Technical Advisor. Fruitgrowers' Federation (now at Massey University) for his assistance and provision of mites for testing. Mr T. McRae of Timaru for permission to use his crops for field tests. The following chemical companies and I or their New Zealand agents for so readily supplying samples of acarides; Ivan Watkins-Dow Limited. Fruitgrowers Chemical Company Limited. Henry H. York & company (New Zealand). Shell Oil (New Zealand) Limited.

  • PDF

Implementation of Gait Analysis System Based on Inertial Sensors (관성센서 기반 보행 분석 시스템 구현)

  • Cho, J.S.;Kang, S.I.;Lee, K.H.;Jang, S.H.;Kim, I.Y.;Lee, J.S.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.9 no.2
    • /
    • pp.137-144
    • /
    • 2015
  • In this paper, we present an inertial sensor-based gait analysis system to measure and analyze lower-limb movements. We developed an integral AHRS(Attitude Heading Reference System) using a combination of rate gyroscope, accelerometer and magnetometer sensor signals. Several AHRS modules mounted on segments of the patient's body provide the quaternions representing the patient segments's orientation in space. And a method is also proposed for calculating three-dimensional inter-segment joint angle which is an important bio-mechanical measure for a variety of applications related to rehabilitation. To evaluate the performance of our AHRS module, the Vicon motion capture system, which offers millimeter resolution of 3D spatial displacements and orientations, is used as a reference. The evaluation resulted in a RMSE(Root Mean Square Error) of 1.08 and 1.72 degree in yaw and pitch angle. In order to evaluate the performance of our the gait analysis system, we compared the joint angle for the hip, knee and ankle with those provided by Vicon system. The result shows that our system will provide an in-depth insight into the effectiveness, appropriate level of care, and feedback of the rehabilitation process by performing real-time limb or gait analysis during the post-stroke recovery.

  • PDF

Feasibility Calculation of FaSTMECH for 2D Velocity Distribution Simulation in Meandering Channel (사행하천의 2차원 유속분포 모의를 위한 FaSTMECH 모형의 적용성 검토)

  • Son, Geunsoo;You, Hojun;Kim, Dongsu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.6
    • /
    • pp.1753-1764
    • /
    • 2014
  • Numerical flow simulation models in the riverine environments have been widely utilized for analyzing flow dynamics in various degrees in researches and practical applications. However, most of the simulated results have been validated based on the data from indoor experimental models or very limited in-situ measurements. Therefore, it has been required to more accurately validate the performance of the numerical models in terms of the detailed field observations. In particular, it was also hard to validate the performances of the existing numerical models in the real meandered river channels that encompass more sophisticated flow and geometric structures. Recently, advancements of the modern flow measuring instrumentations such as acoustic Doppler current profilers (ADCPs) enabled us to efficiently acquire the detailed flow field in the broad range of river channels, thus that it became to be possible to accurately validate any numerical models with the field observations. In this study, based on the detailed flow measurements in a actual meandered river channel using ADCP, we validated FaSTMECH model in iRIC in terms of water surface elevation, which is relatively new but began to get highlighted in the research areas. As the validation site, a meandering channel in River Experiment Center of KICT was chosen, which has 6.5 m of width, 0.38m of flow depth, 1.54 m3/s of flow discharge, 0.61 m/s of mean flow velocity, and 1.2 of sinuosity. As results, whereas the FaSTMECH precisely simulated water surface elevation, simulated velocity field in the bend did not match well with ADCP dataset.

Nonlinear Lateral Behavior and Cross-Sectional Stress Distribution of Concrete Rocking Columns (콘크리트 회전형 기둥의 비선형 횡방향 거동 및 단면응력 분포 분석)

  • Roh, Hwa-Sung;Hwang, Woong-Ik;Lee, Hu-Seok;Lee, Jong-Seh
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.3
    • /
    • pp.285-292
    • /
    • 2012
  • Fixed connection is generally used for beam and column connections of concrete structures, but significant damages at the connection due to severe earthquakes have been reported. In order to reduce damages of the connection and improve seismic performance of the connection, several innovative connections have been suggested. One newly proposed connection type allows a rotation of the connection for applications in rotating or rocking beams, columns, and shear walls. Such structural elements would provide a nonlinear lateral force-displacement response since their contact depth developed during rotation is gradually reduced and the stress across the sections of the elements is non-linearly distributed around a contact area, which is called an elastic hinge region in the present study. The purpose of the present study is to define the elastic hinge region or length for the rocking columns, through investigating the cross-sectional stress distribution during their lateral behavior. Performing a finite element analysis (FEA), several parameters are considered including axial load levels (5% and 10% of nominal strength), different boundary conditions (confined-ends and cantilever types), and slenderness ratios (length/depth = 5, 7, 10). The FEA results showed that the elastic hinge length does not directly depend on the parameters considered, but it is governed by a contact depth only. The elastic hinge length started to develop after an opening state and increased non-linearly until a rocking point(pre-rocking). However, the length did not increase any more after the rocking point (post-rocking) and remained as a constant value. Half space model predicting the elastic hinge length is adapted and the results are compared with the numerical results.

An Analysis of Preservice Earth Science Teachers' Mental Models about Coriolis Force Concept (예비 지구과학 교사의 전향력 개념에 대한 정신모형 변화 분석)

  • Kim, Eunju;Lee, Hyundong;Lee, Hyonyong
    • Journal of The Korean Association For Science Education
    • /
    • v.36 no.3
    • /
    • pp.423-434
    • /
    • 2016
  • The purpose of this study is to investigate preservice earth science teachers' mental models through applications of Coriolis force experiment apparatus. After the root of preconception was examined by face to face interviews based on the questionnaire, five preservice earth science teachers were finally selected for this study. The mental models about concept of Coriolis force was classified into naive mental model, static unstable mental model, dynamic unstable mental model, and scientific mental model through the result of individual interviews and their drawings. According to the mental model analysis about Coriolis' force conception, students C and M showed naive mental model about concept of Coriolis force before experiment. After the experiment, student M's model changed to static unstable mental model. Student C's model improved to dynamic unstable mental model. In adiition, students D and O's model improved from static unstable mental model to dynamic unstable mental model. In the case of student B, the dynamic unstable mental model was maintained after the experiment, however, student B's preconception changed to scientific concept. It turned out that a change occurred from low mental model level to integrated mental model after the application of the developed Coriolis' force experiment apparatus. According to the results, national curriculum is similar to static unstable mental model and the result of developed Coriolis' force experiment apparatus is similar to dynamic unstable mental model. It is suggested that it become the theoretical foundation to develop more comfortable and advanced Coriolis force experiment apparatus by improving the experiment apparatus.

Soft-template Synthesis of Magnetically Separable Mesoporous Carbon (자성에 의해 분리 가능한 메조포러스 카본의 소프트 주형 합성)

  • Park, Sung Soo;Ha, Chang-Sik
    • Journal of Adhesion and Interface
    • /
    • v.18 no.2
    • /
    • pp.75-81
    • /
    • 2017
  • In this study, we synthesized mesoporous carbon (Carbonized Ni-FDU-15) containing nanoporous structures and magnetic nanoparticles. Carbonized Ni-FDU-15 was synthesized via evaporation-induced self-assembly (EISA) and direct carbonization by using a triblock copolymer (F127) as a structure-directing agent, a resol precursor as a carbon-pore wall forming material, and nickel (II) nitrate as a metal ion source. The mesoporous carbon has a well-ordered two-dimensional hexagonal structure. Meanwhile, nickel (Ni) metal and nickel oxide (NiO) were produced in the magnetic nanoparticles in the pore wall. The size of the nanoparticles was about 37 nm. The surface area, pore size and pore volume of Carbonized Ni-FDU-15 were $558m^2g^{-1}$, $22.5{\AA}$ and $0.5cm^3g^{-1}$, respectively. Carbonized Ni-FDU-15 was found to move in the direction of magnetic force when magnetic force was externally applied. The magnetic nanoparticle-bearing mesoporous carbons are expected to have high applicability in a wide variety of applications such as adsorption/separation, magnetic storage media, ferrofluid, magnetic resonance imaging (MRI) and drug targeting, etc.

STATUS AND PROGRESS OF ARGO-M SYSTEM DEVELOPMENT (인공위성 레이저추적 시스템(ARGO-M) 개발 현황)

  • Park, Eun-Seo;Yu, S.Y.;Lim, H.C.;Bang, S.C.;Seo, Y.K.;Park, J.H.;Jo, J.H.;Park, J.U.;Nah, J.K.;Jang, J.G.;Jang, B.H.;Kim, K.D.;Kim, B.I.;Park, C.H.;Lee, S.H.;Ham, S.Y.;Son, Y.S.
    • Publications of The Korean Astronomical Society
    • /
    • v.27 no.3
    • /
    • pp.49-59
    • /
    • 2012
  • KASI (Korea Astronomy and Space Science Institute) has developed an SLR (Satellite Laser Ranging) system since 2008. The name of the development program is ARGO (Accurate Ranging system for Geodetic Observation). ARGO has a wide range of applications in the satellite precise orbit determination and space geodesy research using SLR with mm-level accuracy. ARGO-M (Mobile, bistatic 10 cm transmitting/40 cm receiving telescopes) and ARGO-F (Fixed stationary, about 1 m transmitting/receiving integrated telescope) SLR systems development will be completed by 2014. In 2011, ARGO-M system integration was completed. At present ARGO-M is in the course of system calibration, functionality, and performance tests. It consists of six subsystems, OPS (Optics System), TMS (Tracking Mount System), OES (Opto-Electronic System), CDS (Container-Dome System), LAS (Laser System) and AOS (ARGO Operation System). In this paper, ARGO-M system structure and integration status are introduced and described.

Chromosome Analysis in Clinical Samples by Chromosome Diagnostic System Using Fluorescence in Situ Hybridization (국산 Fluorescence in Situ Hybridization 시스템을 이용한 다양한 검체에서의 염색체 분석)

  • Moon, Shin-Yong;Pang, Myung-Geol;Oh, Sun-Kyung;Ryu, Buom-Yong;Hwang, Do-Yeong;Jung, Byeong-Jun;Choe, Jin;Sohn, Cherl;Chang, Jun-Keun;Kim, Jong-Won;Kim, Seok-Hyun;Choi, Young-Min
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.24 no.3
    • /
    • pp.335-340
    • /
    • 1997
  • Fluorescence in situ hybridization (FISH) techniques allow the enumeration of chromosome abnormalities and from a great potential for many clinical applications. In order to produce quantitative and reproducible results, expensive tools such as a cooled CCD camera and a computer software are required. We have developed a Chromosome Image Processing System (Chips) using FISH that allows the detection and mapping of the genetic aberrations. The aim of our study, therefore, is to evaluate the capabilities of our original system using a black-and-white video camera. As a model system, three repetitive DNA probes (D18Z1, DXZ1, and DYZ3) were hybridized to variety different clinical samples such as human metaphase spreads and interphase nuclei obtained from uncultured peripheral blood lymphocytes, uncultured amniocytes, and germ cells. The visualization of the FISH signals was performed using our system for image acquisition and pseudocoloring. FISH images were obtained by combining images from each of probes and DAPI counterstain captured separately. Using our original system, the aberrations of single or multiple chromosomes in a single hybridization experiment using chromosomes and interphase nuclei from a variety of cell types, including lymphocytes, amniocytes, sperm, and biopsied blastomeres, were enabled to evaluate. There were no differences in the image quality in accordance with FISH method, fluorochrome types, or different clinical samples. Always bright signals were detected using our system. Our system also yielded constant results. Our Chips would permit a level of performance of FISH analysis on metaphase chromosomes and interphase nuclei with unparalleled capabilities. Thus, it would be useful for clinical purposes.

  • PDF

A Numerical Study on the Flow and Heat Transfer Characteristics of Aluminum Pyramidal Truss Core Sandwich (알루미늄 피라미드 트러스 심재 샌드위치의 열유동 특성에 관한 수치해석 연구)

  • Kang, Jong-Su;Kim, Sang-Woo;Lim, Jae-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.638-644
    • /
    • 2019
  • In this study, the fluid flow and heat transfer characteristics within sandwich panels are investigated using computational fluid dynamics. Within the sandwich panels having periodic cellular cores, air can freely move inside the core section so that the structure is able to perform multi-functional roles such as simultaneous load bearing and heat dissipation. Thus, there needs to examine the thermal and flow analysis with respect to design variables and various conditions. In this regard, ANSYS Fluent was utilized to explore the flow and heat transfer within the pyramidal truss sandwich structures by varying the truss angle and inlet velocity. Without the entry effect in the first unitcell, the constant rate of pressure and the constant rate of Nusselt number was observed. As a result, it was demonstrated that Nusselt number increases and friction factor decreases as the inlet velocity increases. Moreover, the rate of Nusselt number and friction factor was appreciable in the range of V=1-5m/s due to the transition from laminar to turbulent flow. Regarding the effect of design variable, the variation of truss angle did not significantly influence the characteristics.

A study on the current status and development of the new health technology assessment of Korean medicine field (한의 신의료기술 평가 활성화 방안 제언)

  • Park, Minjung;Jung, Youjin;Son, Soo Kyung;Kwon, Soohyun;Kim, Nankwen;Kim, Jong Woo;Park, Dong Ah;Chung, Seok-Hee
    • The Journal of Korean Medicine
    • /
    • v.40 no.3
    • /
    • pp.59-75
    • /
    • 2019
  • Objectives: The purpose of this study is to examine the current status of Korean medicine health technology assessment and explore realistic plans to activate it. Methods: We investigated all the applications for new health technology assessment related to Korean medicine from 2007 to 2016. The several expert meetings were held to draw out the barriers and improvement strategies of the new health technology assessment of Korean medicine field. Results: There were 31 cases in total except for duplications or reapplies falling into 3 main types. First, 19 of them were to try to enter a medical market and be covered by National Health Insurance. Eight cases were to apply western medicine technology as new health technology in Korean medicine area. The rest was 4 cases, which were totally not appropriate for the purpose of new health technology assessment system. According to the expert opinion, the obstacles of activation in new health technology assessment of Korean medicine were application of unstandardized technology, lack of understanding and experience, lack of clinical trial supporting system for Korean medicine, lack of committee members within the nHTA(new Health Technology Assessment) review board, ambiguous definition of medical practice and sharp conflict between western medicine and Korean medicine. Conclusions: Several suggestions were derived. First of all, to activate Korean medicine in the nHTA system, the existing system should be used sufficiently, and multifaceted efforts are needed to upgrade the system, if necessary. Also, self-help efforts, Korean medicine clinical trial supporting system and increasing R&D investment, establishing extra-committee for Korean medicine in nHTA could be needed. Finally, long-term strategy for improving collaboration between Korean medicine and western medicine should be considered.