• Title/Summary/Keyword: 3D accuracy

Search Result 2,875, Processing Time 0.035 seconds

Generation and Comparison of 3-Dimensional Geospatial Information using Unmanned Aerial Vehicle Photogrammetry Software (무인항공사진측량 소프트웨어를 이용한 3차원 공간정보 생성 및 비교)

  • Yang, Sung-Ryong;Lee, Hak-Sool
    • Journal of the Society of Disaster Information
    • /
    • v.15 no.3
    • /
    • pp.427-439
    • /
    • 2019
  • Purpose: We generated geospatial information of unmanned aerial vehicle based on various SW and analyzed the location accuracy of orthoimage and DSM and texture mapping of 3D mesh. Method: The same unmanned aerial image data is processed using two different SW, and spatial information is generated. Among the generated spatial information, the orthoimage and DSM were compared with the spatial information generation results of the unmanned aerial photogrammetry SW by performing quantitative analysis by calculating RMSE of horizontal position and vertical position error and performing qualitative analysis. Results: There were no significant differences in the positional accuracy of the orthoimage and DSM generated by each SW, and differences in texture mapping in 3D mesh. The creation of the 3D mesh indicated the impact of the Unmanned Aerial Photogrammetry SW. Conclusion: It is shown that there is no effect of SW on the creation of orthoimage and DSM for geospatial analysis based on unmanned aerial vehicle. However, when 3D visualization is performed, texture mapping results are different depending on SW.

A Study on the Feasibility of the 3D Scanning Method of Body Measurement and Wearing Evaluation (3D Scanner를 이용한 인체계측방법 및 플레어스커트의 착의형태평가방법에 관한 연구)

  • 김혜경;석은영;서추연
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.24 no.6
    • /
    • pp.895-906
    • /
    • 2000
  • The study planned to testify the accuracy of the 3D scanner through analyzing the human body measurement method and the evaluation of flare skirt with 3D scanner. The results obtained from this study were as follows; First, the results of measurement for the dress form and human body by 3D scanner were more accurate than one or two dimensional measurement method. Second, from the results of the scan for the flare skirts as worn the human body, we could obtain very accurate horizontal section map. Third, in the clothing ergonomics viewpoint, the accuracy of the 3D scanner was very excellent and its utility was higher than that of the moir photography method. Therefore, the 3D scanner is very useful for the human body measurement and the wearing evaluation. In a nutshell, this study illustrates that we have to develop a program of automatic human body measurement system which will enhance the application of the 3D scanner.

  • PDF

Precision Analysis of Workpieces made with Dental 3D Printing Technology (치과용 3D 프린팅 기술로 제작된 가공물의 정밀성 분석)

  • Choi, Sung-min
    • Journal of Technologic Dentistry
    • /
    • v.40 no.4
    • /
    • pp.231-237
    • /
    • 2018
  • Purpose: The development of the dental technology industry has digitized the dental process. Definition of Digitalization of Dental Implantation Digitalization is the process of model making and prosthodontic processing using 3D CAD and CAM. Currently, it is becoming popular due to the spread of various devices. However, precision evaluation at this stage is an important factor in precision-based dental procedures. Therefore, in this study, we want to analyze the precision of the processed body made with digital dental machine. Methods: The accuracy of digital dental pore devices was evaluated. Specimens were fabricated with 5 types of 3D printers. The external shape was measured with the prepared specimen. The surface roughness was measured. Results: As a result, precision was excellent in order of EP2 specimen, EP1 specimen, and EA2 specimen. The precision of EP3 specimen and EA1 specimen is not excellent. And the precision of the specimen processed with polymer 3D printer is excellent. The accuracy of LCPS type polymer 3D printers is considered to be excellent. Conclusion : 1. Observation of the shape The 3D printer for LCPS system and the 3D printer for SLM $40{\mu}m$ system were found to be precisely processed. 2. Surface roughness results The LCPS system polymer 3D printer has been shown to have a precise surface.

Accuracy of dies fabricated by various three dimensional printing systems: a comparative study (다양한 삼차원 프린팅 시스템으로 제작된 다이의 정확도 비교)

  • Baek, Ju Won;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.4
    • /
    • pp.242-253
    • /
    • 2020
  • Purpose: The aim of this study was to compare the accuracy of dies fabricated using 3D printing system to conventional method and to evaluate overall volumetric changes by arranging the superimposed surfaces. Materials and Methods: A mandibular right first molar from a dental model was prepared, scanned and fabricated with composites of polyetherketoneketone (PEKK). Master dies were classified into 4 groups. For the conventional method, the impression was taken with polyvinylsiloxane and the impression was poured with Type IV dental stone. For the 3D printing, the standard die was scanned and converted into models using three different 3D printers. Each of four methods was used to make 10 specimens. Scanned files were superimposed with the standard die by using 3D surface matching software. For statistical analysis, Kruskal-Wallis test and Mann-Whitney U test were done (P < 0.05). Results: Compared to the standard model, the volumetric changes of dies fabricated by each method were significantly different except the models fabricated by conventional method and 3D printer of Stereolithography (P < 0.05). The conventional dies showed the lowest volumetric change than 3D printed dies (P < 0.05). 3D printed dies fabricated by Stereolithography showed the lowest volumetric change among the different 3D printers (P < 0.05). Conclusion: The conventional dies were more accurate than 3D printed dies, though 3D printed dies were within clinically acceptable range. Thus, 3D printed dies can be used for fabricating restorations.

The Improvement of RFM RPC Using Ground Control Points and 3D Cube

  • Cho, Woo-Sug;Kim, Joo-Hyun
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.1143-1145
    • /
    • 2003
  • Some of satellites such as IKONOS don't provide the orbital elements so that we can’ utilize the physical sensor model. Therefore, Rational Function Model(RFM) which is one of mathematical models could be a feasible solution. In order to improve 3D geopositioning accuracy of IKONOS stereo imagery, Rational Polynomial Coefficients(RPCs) of the RFM need to be updated with Ground Control Points(GCPs). In this paper, a method to improve RPCs of RFM using GCPs and 3D cube is proposed. Firstly, the image coordinates of GCPs are observed. And then, using offset values and scale values of RPC provided, the image coordinates and ground coordinates of 3D cube are initially determined and updated RPCs are computed by the iterative least square method. The proposed method was implemented and analyzed in several cases: different numbers of 3D cube layers and GCPs. The experimental results showed that the proposed method improved the accuracy of RPCs in great amount.

  • PDF

3-D Surface Profile Measurement Using An Acousto-optic Tunable Filter Based Spectral Phase Shifting Technique

  • Kim, Dae-Suk;Cho, Yong-Jai
    • Journal of the Optical Society of Korea
    • /
    • v.12 no.4
    • /
    • pp.281-287
    • /
    • 2008
  • An acousto-optic tunable filter based 3-D micro surface profile measurement using an equally spaced 5 spectral phase shifting is described. The 5-bucket spectral phase shifting method is compared with a Fourier-transform method in the spectral domain. It can provide a fast measurement capability while maintaining high accuracy since it needs only 5 pieces of spectrally phase shifted imaging data and a simple calculation in comparison with the Fourier transform method that requires full wavelength scanning data and relatively complicated computation. The 3-D profile data of micro objects can be obtained in a few seconds with an accuracy of ${\sim}10nm$. The 3-D profile method also has an inherent benefit in terms of being speckle-free in measuring diffuse micro objects by employing an incoherent light source. Those simplicity and practical applicability is expected to have diverse applications in 3-D micro profilometry such as semiconductors and micro-biology.

Denoising 3D Skeleton Frames using Intersection Over Union

  • Chuluunsaikhan, Tserenpurev;Kim, Jeong-Hun;Choi, Jong-Hyeok;Nasridinov, Aziz
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2021.11a
    • /
    • pp.474-475
    • /
    • 2021
  • The accuracy of real-time video analysis system based on 3D skeleton data highly depends on the quality of data. This study proposes a methodology to distinguish noise in 3D skeleton frames using Intersection Over Union (IOU) method. IOU is metric that tells how similar two rectangles (i.e., boxes). Simply, the method decides a frame as noise or not by comparing the frame with a set of valid frames. Our proposed method distinguished noise in 3D skeleton frames with the accuracy of 99%. According to the result, our proposed method can be used to track noise in 3D skeleton frames.

A Study on the Diagnostic Accuracy Rate of the Sasang Constitution Questionnaire for Doctors Used in the On-line System (온라인 진단시스템에 사용되는 의사용 체질진단함수의 진단정확률 연구)

  • Jeon, Soo-Hyung;Jeong, Seong-Il;Kwon, Seok-Dong;Park, Se-Jung;Kim, Kyu-Kon;Kim, Jong-Won
    • Journal of Sasang Constitutional Medicine
    • /
    • v.20 no.3
    • /
    • pp.82-93
    • /
    • 2008
  • 1. Objective The purpose of this study was to develop and upgrade the On-line SSCQ (Sasang Constitution Questionnaire) by making an analysis of diagnostic accuracy rate of Sasang Constitution Questionnaire for doctors. 2. Methods We have collected SSCQ-D(Sasang Constitution Questionnaire for Doctors) from the dept. of Sasang constitutional medicine in the four other university. We classified data according to Sasang constitution, sex, age and BMI and made an analysis using the chiefly discriminant analysis model, additionally frequency analysis, and Cronbach's alpha coefficient. 3. Results and Conclusion 1) Diagnostic accuracy rate of the SSCQ-D was between 71.33 and 95.14%. (1) About the whole subject the accuracy rate was 71.33%. (2) About the whole female the accuracy rate was 73.26%. (3) About the whole male the accuracy rate was 81.41%. 2) The more classification variables we used in this analysis study, the higher the diagnostic accuracy rate increased.

  • PDF

3D Geopositioning Accuracy Assessment Using KOMPSAT-2 RPC (KOMPSAT-2 RPC를 이용한 3차원 위치결정 정확도 분석)

  • Oh, Kwan-Young;Jung, Hyung-Sup;Lee, Won-Jin;Lee, Dong-Taek
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.29 no.1
    • /
    • pp.1-9
    • /
    • 2011
  • The objective of this paper is to improve the accuracy of the 3D geopositioning extracted from Rational Polynomial Coefficient(RPC) provide in the KOMPSAT-2 metadata files. In this paper, we developed the algorithm to adjust a RFM(Rational Functional Model), and could improve the accuracy of a RFM with this algorithm. Furthermore, when a RFM was adjusted with this algorithm, the effects of the number of GCPs on the accuracy of the adjusted RFM was tested. For accuracy assessment using adjusted RFM, 9 ground control points(GCPs) and 24 check points could be used. Results indicated that the root mean squared errors(RMSEs) of horizontal residual errors calculated 24 check points were 2.20(m). The achieved accuracy of three dimensional object-point determination was 1.72(m) in the X-dimension and 1.37(m) in the Y-dimension and 2.20(m) in the Z-dimension.

A Verification of the Accuracy in BIM-Based Quantity Taking-Off - Focusing on Finishing Work (BIM 기반 물량 산출의 정확성 검증 - 마감공사 공종을 중심으로)

  • Kim, Ji-Hyun;Yoon, Su-Won
    • Journal of KIBIM
    • /
    • v.3 no.2
    • /
    • pp.1-9
    • /
    • 2013
  • Currently, various studies and applications related BIM based quantity take-off have been attempted, because of the accuracy of cost estimating and reliability by using the BIM model information in automatical calculation. Finishing works that have a large number of various types and materials need the higher accuracy and reliability on the BIM-based quantity take-off. Therefore, this study compared and analyzed 2D and 3D based quantity through Test-bed and determine the cause of the quantity difference. This verified the accuracy and efficiency in the BIM-based quantity take-off for finishing works. Also this study has been proposed opinions for calculating the exact BIM-based quantity take-off.