• Title/Summary/Keyword: 3D Scan Data

Search Result 393, Processing Time 0.029 seconds

A Measure of Landscape Planning and Design Application through 3D Scan Analysis (3D 스캔 분석을 통한 전통조경 계획 및 설계 활용방안)

  • Shin, Hyun-Sil
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.36 no.4
    • /
    • pp.105-112
    • /
    • 2018
  • This study aims to apply 3D scanning technology to the field of landscape planning design. Through this, 3D scans were conducted on Soswaewon Garden and Seongrakwon Gardens to find directions for traditional landscape planning and designs. The results as follows. First, the actual measurement of the traditional garden through a 3D scan confirmed that a precise three-dimensional modeling of ${\pm}3-5mm$ error was constructed through the merging of coordinate values based on point data acquired at each observation point and postprocessing. Second, as a result of the 3D survey, the Soswaewon Garden obtained survey data on Jewoldang House, Gwangpunggak Pavilion, the surrounding wall, stone axis, and Aeyangdan wall, while the Seongnakwon Garden obtained survey data on the topography, rocks and waterways around the Yeongbyeokji pond area. The above data have the advantage of being able to monitor the changing appearance of the garden. Third, spatial information developed through 3D scans could be developed with a three-dimensional drawing preparation and inspection tool that included precise real-world data, and this process ensured the economic feasibility of time and manpower in the actual survey and investigation of landscaping space. In addition, modelling with a three-dimensional 1:1 scale is expected to be highly efficient in that reliable spatial data can be maintained and reprocessed to a specific size depending on the size of the design. In addition, from a long-term perspective, the deployment of 3D scan data is easy to predict and simulate changes in traditional landscaping space over time.

Development of Bodice Dress Forms by Body Types for Women in Thirties Applying 3D Body Scan Data (3D 인체 스캔 데이터를 활용한 체형별 인대모형 개발에 관한 연구)

  • Suh, Dong-Ae;Oh, Seol-Yong
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.9
    • /
    • pp.136-145
    • /
    • 2012
  • This research proposes a pattern making method for women's bodice by the characters of body types and develops bodice dress forms on their body shapes applying 3D body scan data. 515 women's body scan data was collected and analyzed factor and cluster analysis. Three body types were characterized in normal, obese, and slim group. In each group, 10 subjects were selected. 20 parts in 3D anthropometric data were measured using Autocad program. The amount of waist dart was calculated and three types of basic bodice pattern were developed using the calculated darts data. The amount and the position of front dart and side dart were different at obese group in comparison of normal and thin group. The three types of basic bodice model were made by the basic bodice pattern, and each model was scanned by 3D scanner to make 3D bodice dress forms. Three types of bodice dress forms were rendered using 3D max program. Bodice dress forms had the dart lines and were useful to draft patterns to fit their body shape.

3D scanning based mold correction for planar and cylindrical parts in aluminum die casting

  • Seno, Takashi;Ohtake, Yutaka;Kikuchi, Yuji;Saito, Noriaki;Suzuki, Hiromasa;Nagai, Yukie
    • Journal of Computational Design and Engineering
    • /
    • v.2 no.2
    • /
    • pp.96-104
    • /
    • 2015
  • Aluminum die casting is an important manufacturing process for mechanical components. Die casting is known to be more accurate than other types of casting; however, post-machining is usually necessary to achieve the required accuracy. The goal of this investigation is to develop machining- free aluminum die casting. Improvement of the accuracy of planar and cylindrical parts is expected by correcting metal molds. In the proposed method, the shape of cast aluminum made with the initial metal molds is measured by 3D scanning. The 3D scan data includes information about deformations that occur during casting. Therefore, it is possible to estimate the deformation and correction amounts by comparing 3D scan data with product computer-aided design (CAD) data. We corrected planar and cylindrical parts of the CAD data for the mold. In addition, we corrected the planar part of the metal mold using the corrected mold data. The effectiveness of the proposed method is demonstrated by evaluating the accuracy improvement of the cast aluminum made with the corrected mold.

A Study on 3D Scan Technology for Find Archetype of Youngbeokji in Seongnagwon Garden (성락원 영벽지의 원형 파악을 위한 3D 스캔기술 연구)

  • Lee, Won-Ho;Kim, Dong-Hyun;Kim, Jae-Ung;Park, Dong-Jin
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.31 no.3
    • /
    • pp.95-105
    • /
    • 2013
  • This study on circular identifying purposes was performed of Youngbeokji space located in Seongnagwon(Scenic Sites No.35). Through the data acquisition of 3D high precision, such as the surrounding terrain of the Youngbeokji. The results of this study is summarized like the following. First, the purpose of the stone structures and structure within the Youngbeokji search is an important clue to find that earlier era will be a prototype. 3D scan method of enforcement is searching the whole structure, including the surrounding terrain and having the easy way. Second, the measurement results are as follows. Department of bedrock surveyed from South to North was measured by 7,665mm. From East to West was measured at 7,326mm. The size of the stone structures, $1,665mm{\times}1,721mm$ in the form of a square. Its interior has a diameter of 1, 664mm of hemispherical form. In the lower portion of the rock masses in the South to the North, has fallen out of the $1,006mm{\times}328mm$ scale traces were discovered. Third, the Youngbeokji recorded in the internal terrain Multiresolution approach. After working with the scanner and scan using the scan data, broadband, to merge. Polygon Data conversion to process was conducted and mash as fine scan data are converted to process data. High resolution photos obtained through the creation of 3D terrain data overlap and the final result. Fourthly, as a result of this action, stone structure West of the waterway back outgoing times oil was confirmed. Bangjiwondo is estimated to be seokji of structure hydroponic facility confirmed will artificially carved in the bedrock. As a result of this and the previous situation of the 1960s could compare data was created. This study provides 3D precision ordnance through the acquisition of the data. Excavations at the circle was able to preserve in perpetuity as digital data. In the future, this data is welcome to take a wide variety of professionals. This is the purpose of this is to establish foundations and conservation management measures will be used. In addition, The new ease of how future research and 3D scan unveiled in the garden has been used in the study expect.

Marginal and internal discrepancy of 3-unit fixed dental prostheses fabricated by subtractive and additive manufacturing (절삭 및 적층 가공법으로 제작된 3본 고정성 국소의치의 변연 및 내면 적합도에 관한 연구)

  • Choi, Jae-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.1
    • /
    • pp.7-13
    • /
    • 2020
  • Purpose: This study was to evaluate marginal and internal discrepancy of 3-unit fixed dental prostheses (FDP) fabricated by subtractive manufacturing and additive manufacturing. Materials and methods: 3-unit bridge abutments without the maxillary left second premolar were prepared (reference model) and the reference model scan data was obtained using an intraoral scanner. 3-unit fixed dental prostheses were fabricated in the following three ways: Milled 3-unit FDP (MIL), digital light processing (DLP) 3D printed 3-unit FDP (D3P), stereolithography apparatus (SLA) 3D printed 3-unit FDP (S3P). To evaluate the marginal/internal discrepancy and precision of the prosthesis, scan data were superimposed by the triple-scan protocol and the combinations calculator, respectively. Quantitative and qualitative analysis was performed using root mean square (RMS) value and color difference map in 3D analysis program (Geomagic control X). Statistical analysis was performed using the Kruskal-Wallis test (α=.05), MannWhitney U test and Bonferroni correction (α=.05/3=.017). Results: The marginal discrepancy of S3P group was superior to MIL and D3P groups, and MIL and D3P groups were similar. The D3P and S3P groups showed better internal discrepancy than the MIL group, and there was no significant difference between the D3P and S3P groups. The precision was excellent in the order of MIL, S3P, and D3P groups. Conclusion: Within the limitation of this study, the 3-unit fixed dental prostheses fabricated by additive manufacturing showed better marginal and internal discrepancy than the those of fabricated by subtractive manufacturing, but the precision was poor.

Considerations for Developing a SLAM System for Real-time Remote Scanning of Building Facilities (건축물 실시간 원격 스캔을 위한 SLAM 시스템 개발 시 고려사항)

  • Kang, Tae-Wook
    • Journal of KIBIM
    • /
    • v.10 no.1
    • /
    • pp.1-8
    • /
    • 2020
  • In managing building facilities, spatial information is the basic data for decision making. However, the method of acquiring spatial information is not easy. In many cases, the site and drawings are often different due to changes in facilities and time after construction. In this case, the site data should be scanned to obtain spatial information. The scan data actually contains spatial information, which is a great help in making space related decisions. However, to obtain scan data, an expensive LiDAR (Light Detection and Ranging) device must be purchased, and special software for processing data obtained from the device must be available.Recently, SLAM (Simultaneous localization and mapping), an advanced map generation technology, has been spreading in the field of robotics. Using SLAM, 3D spatial information can be obtained quickly in real time without a separate matching process. This study develops and tests whether SLAM technology can be used to obtain spatial information for facility management. This draws considerations for developing a SLAM device for real-time remote scanning for facility management. However, this study focuses on the system development method that acquires spatial information necessary for facility management through SLAM technology. To this end, we develop a prototype, analyze the pros and cons, and then suggest considerations for developing a SLAM system.

Building 3D model using laser scan data

  • Choi, Sung-Hun;Kim, Dong-Seok;Lee, Heung-Jae;Lee, Kwae-Hi
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.101-105
    • /
    • 2002
  • In this paper we describe techniques for the automated creation of geometric correct 3-D models of the building using two 2-D laser scanners. One of the laser scanners is used for position estimation using a scan matching algorithm, while the other is used to build 3-D models of the facade of the buildings. Those models can be used for virtual reality, tele-presence, digital cinematography and urban planning applications. Results are shown for building models in our campus using real data acquired from two sensors.

  • PDF

Analysis of Foot Shape and Size System of Male High School Students Using 3D Scan Data (3D 스캔 데이터를 활용한 남자 고등학생의 발 형태 및 치수체계 분석)

  • Shin, Yu Jin;Park, Soonjee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.44 no.1
    • /
    • pp.53-67
    • /
    • 2020
  • The purpose of this study is to analyze the foot shape and size specification of male high school students. 3D modeling programs such as 'Artec Studio', 'CATIA', and 'Auto CAD' measured the 3D scan data of 361 male high school students provided by KATS. Through principal factor analysis, 10 factors were extracted, including foot length, medial-lateral ratio, and foot length ratio. As the result of the cluster and ANOVA with post-hoc test (Duncan method), the differences among types were clarified. Type 1 (24.7%) represented outward medial-lateral ratio (M-L ratio) with the lowest instep, ankle and little deformed first toe. Type 2 (41.8%) was characterized by the shortest, even M-L ratio, thin ankle and heel, the highest instep and ankle. Type 3 (33.5%) showed the longest, inward M-L ratio, thick ankle and heel, and deformed first toe. As the cross-tabulation of foot length and ball circumference, 17.2 percent was not covered by KS standard; in addition, the foot length was longer than the KS standard. The correlation analysis of key dimensions showed that foot length and ball circumference were highly correlated with other items; therefore, regression equations were derived to estimate other foot measurements using these two items as independent variables.

Comparative Analysis of Body Measurement and Fit Evaluation between 2D Direct Body Measuring and 3D Body Scan Measuring (직접측정과 3차원 측정에 따른 인체치수 및 의복 착장 비교분석)

  • Istook, Cynthia L.;Lim, Ho-Sun;Chun, Jong-Suk
    • The Research Journal of the Costume Culture
    • /
    • v.19 no.6
    • /
    • pp.1347-1358
    • /
    • 2011
  • This study purposed to analyze differences in body measurement between the 2D direct body measuring method and the 3D body scan measuring method and to perform the appearance evaluation and cross-sectional evaluation of the fit of pants to which body measurements obtained by each measuring method were applied. Body measuring was conducted in 10 women in their 20s-30s using 2D direct body measuring and 3D automatic measuring with Hamamatsu body scanner. Among the 10 women, 3 participated in experimental garment wearing. Experimental pants were made using their 2D direct body measurements and 3D automatic measurements, and wearing tests were performed through expert evaluation and cross-sectional evaluation. The results of the experiment were as follows. According to the results of comparative analysis on differences between 2D direct body measurements and 3D scan measurements, 3D automatic measurements were significantly larger in bust circumference, ankle circumference, armscye circumference, shoulder length, scye depth, and arm length. As circumferences measured with the 3D body scanner were somewhat larger than directly measured ones, it is suggested to adjust ease when using existing pattern making methods. We prepared experimental garments by the same pattern making method through applying body measurements obtained with the two measuring methods, and assessed the fit of the garment comparatively through expert evaluation and 3D scan cross-sectional evaluation. According to the results, 2D-pants using 2D direct body measurements was slightly tighter than 3D-pants using 3D measurements in waist circumference, hip circumference, and abdominal circumference. In the results of comparing appearance in terms of the fit of the experimental garment in each subject, significant difference was observed in most of the compared items. This result suggests that 3D automatic body measuring data may show different accuracy according to body shape and therefore it is necessary to examine difference between 2D direct body measurements and 3D automatic measurements according to body shape.