• 제목/요약/키워드: 3D Master Model

검색결과 69건 처리시간 0.023초

CAD/CAM 밀링 시스템을 활용한 단일 치관과 3본 교의치의 3D 적합도 평가 (Three-dimensional evaluation of the internal adaptation of single and three-unit fixed dental restoration by CAD/CAM milling system)

  • 김소리;김총명;김웅철;김지환
    • 대한치과기공학회지
    • /
    • 제39권1호
    • /
    • pp.35-42
    • /
    • 2017
  • Purpose: The purpose of this paper was to evaluate the occurrence of errors regarding adaptation by conducting a three-dimensional assessment comparing the bridge type dental restoration after the cutting process, which has multiple abutments, with a single type dental restoration. Methods: By using ten identical files obtained by scanning the master model, thirty designs were created consisting of ten maxillary right first premolars and ten maxillary right first molars with single crown abutments, along with ten bridge designs with the identical abutment. A 5-axis milling machine was used to produce the design file. The produced denture prostheses were scanned using a silicone replica for a STL file. An evaluation was conducted using 3D analysis software on the master model and each of the thirty data files. Results: The RMS value of the pre-molar (14) was $38.4{\pm}4{\mu}m$ for single and $54.7{\pm}6{\mu}m$ for bridge abutment; therefore, a statistically significant difference was observed for single and bridge designs although both shared the same abutment form (P<.05). Also, the RMS value of the molar (16) was $47.6{\pm}2{\mu}m$ and $56.6{\pm}5{\mu}m$ for the single and bridge designs, respectively, thereby presenting a statistically significant difference (P<.05). Conclusion: As a result, dental prosthesis fabricated using the single method presented better internal adaptation outcomes.

가변형 치과 인상용 트레이로 제작된 모형의 재현성 (Accuracy of Stone Cast Produced by Adjustable Dental Impression Tray)

  • 박광수;동진근;심헌보;오상천
    • 구강회복응용과학지
    • /
    • 제22권4호
    • /
    • pp.317-328
    • /
    • 2006
  • Purpose: This study was performed to measure the accuracy of adjustable dental impression trays by a scanning laser three-dimensional digitizer. Materials and Methods: Metal stock tray and adjustable stock trays were used for 40 stone casts(10 casts each) duplicated a resin master model of mandible and maxilla. The type IV dental stone was poured in a allginate impressions and allowed to set for one hour. The casts were digitized using an optical digitizer. The distance between the reference points were measured and analyzed on the graphic image of 3-D graphic software (CATIA version 5.0). The statistical significance of the differences between the groups was determined by a two-way ANOVA. Results: There were no significant differences between the accuracies of the adjustable stock tray and the master model except anterior arch width of the upper arch and the diagonal arch length and arch length(one side) of the lower arch. Conclusion: The adjustable stock trays showed clinically acceptable accuracies of the study casts produced by them.

사각형강목의 끝자루를 이용한 트롤어구의 어획선택성 연구 ( I ) - 사각형강목의 어획선택성 - ( Studies on the Selectivity of the Trawl Net With the Square Mesh Cod-End ( 1 ) - Selectivity of the Square Mesh Cod-End - )

  • 이주희;김삼곤;김진건
    • 수산해양기술연구
    • /
    • 제30권3호
    • /
    • pp.161-171
    • /
    • 1994
  • Mesh selection analysis for the trawl net were carried out at the Southern Korean Sea and the East China Sea during the 1992-1994 years by the training ship Seabada of the National Fisheries University of Pusan, using A type (51.2mm), B type (70.2mm), C type (77.6mm), D type (88.0mm) square mesh cod-ends. The fishing trials were made using bottom trawl of the trouser type cod-end with cover net. Selection curves and selection parameters were calculated by a logistic model for Sphyraena pinguis, Pampus argenteus, Trachurus japonicus, Pagrus major, Callanthias japonicus, Trichiurus lepturus. The results obtained are summarized as follows: 1. Red barracuda : Selection range and fifty percent selection length in the A type was 115.8mm, 292.8mm, respectively. 2. Harvest fish : Each selection range and fifty percent selection length in the B. C. and D type was 37.7mm, 113.8mm : 40.1mm, 131.7mm and 64.8mm, 148.6mm, respectively. Selection parameters of master curve were : slope, 3.81 : intercept, -6.4. Optimum mesh size was 89.3mm. 3. Horse mackerel : Each selection range and fifty percent selection length in the A, B, C and D type was 43.0mm, 148.3mm : 60.7mm, 183.2mm, 214.5mm and 91.4mm, 254.9mm, respectively. Selection parameters of master curve were : slope 2.30 : intercept, -6.4. Optimum mesh size was 66.8mm. 4. Red seabrem : Selection range and fifty percent selection length in the D type was 42.7mm, 203.4mm, respectively. 5. Yellowsail red bass : Selection range and fifty percent selection length in the A type was 84.0mm, 110.6mm, respectively. 6. Hair tail : Each selection range and fifty percent selection length in the A, B and C type was 59.7mm, 176.0mm : 100.9mm, 250.7mm and 178.6mm, 307.0mm, respectively. Selection parameters of master curve were : slope, 1.54 : intercept, -5.4. Optimum mesh size was 57.5mm.

  • PDF

사각형강목의 끝자루를 이용한 트롤어구의 어획선택성 연구 ( 2 ) - 다이아몬드형강목과 사각형강목의 선택성비교 - ( Studies on the Selectivity of the Trawl Net With the Square Mesh Cod-End ( 2 ) - Comparison of Diamond and Square Mesh Cod-End - )

  • 김삼곤;이주희;박정식
    • 수산해양기술연구
    • /
    • 제30권3호
    • /
    • pp.172-181
    • /
    • 1994
  • The mesh selectivity of diamond and suare mesh cod-ends at the Southern Korean Sea and the East China Sea were compared for Pampus argenteus, Trachurus japonicus, Trichiurus lepturus. Selection trials were carried out using diamond and square mesh cod-end by trouser type cod-end with cover net. of which the mesh cod-end has four types : A(51.2mm), B(70.2mm), C(77.6mm), D(88.0mm). Selection curves and selection parameters were calculated using a logistic model. The results obained are summarized as follows : 1. Harvest fish : In B. C and D type selection range and fifty percent selection length of the square mesh were about 21mm, 11mm : 12mm, 18mm and 34mm, 5mm higher than those of the diamond mesh, respectively. Selection factor of master curve for the diamond mesh was 1.54 and for the square mesh was 1.68. The optimum mesh size for the diamond mesh was 97.4mm and for the square mesh was 89.3mm, the difference was 8.1mm. 2. Horse mackerel : In A type, selection range was nearly the same for the diamond and the square mesh, but fifty percent selection length of the square mesh was 43mm higher than the diamond mesh. In B. C and D type, selection range and fifty percent selection length of the square mesh were about 6mm, 3mm : 24mm, 21mm and 11mm, 42mm higher than those of the diamond mesh, respectively. Selection factor of master curve for the diamond mesh was 2.37, for the square mesh was 2.77. The optimum mesh size for the diamond mesh was 78.1mm and for the square mesh was 66.8mm, the difference was 11.3mm. 3. Hair tail : In A, B and C type, selection range of the square mesh was about 34mm, 8mm, 60mm higher than those of the diamond mesh. Fifty percent selection length for the diamond mesh was about 5mm, 7mm, 8mm higher than that of the square mesh. Selection factor of master curve for the diamond mesh was 3.11, for the square mesh was 3.48. The optimum mesh size for the diamond mesh was 64.3mm and for the square mesh was 57.5mm, the difference was 6.8mm.

  • PDF

Bistable Domain Wall Configuration in a Nanoscale Magnetic Disc: A Model for an Inhomogeneous Ferromagnetic Film

  • Venus D.
    • Journal of Magnetics
    • /
    • 제10권3호
    • /
    • pp.113-117
    • /
    • 2005
  • Some polycrystalline ferromagnetic mms are composed of continuously connected nanometer scale islands with random crystallite orientations. The nanometer perturbations of the mm introduce a large number of nearly degenerate local field configurations that are indistiguishable on a macroscopic scale. As a first step, this situation is modelled as a thin ferromagnetic disc coupled by exchange and dipole interactions to a homogeneous ferromagnetic plane, where the disc and plane have different easy axes. The model is solved to find the partial $N\acute{e}el$ domain walls that minimize the magnetic energy. The two solutions give a bistable configuration that, for appropriate geometries, provides an important microsopic ferromagnetic degree of freedom for the mm. These results are used to interpret recent measurements of exchange biased bilayer films.

세 가지 방식으로 제작된 레진코핑의 내면적합성 평가: 3차원적 분석 (Assessment of internal fitness on resin copings fabricated by 3 - ways methods: Three - dimensional analysis)

  • 강신영;박진영;김동연;김웅철
    • 대한치과기공학회지
    • /
    • 제39권1호
    • /
    • pp.17-24
    • /
    • 2017
  • Purpose: The purpose of this study was to evaluate the internal fitness of the resin coping that was fabricated by the traditional and Digital manufacturing methods through 3-dimensional analysis. Methods: maxillary right second molar was chosen implant master model. Custom-built impression trays were manufactured. After screwing the pick-up impression coping onto the master cast, impressions were made with silicone impression. The Working model was then made with type IV stone. The coping was fabricated: SLAC group (n=8), APPC group (n=8), LAPC group (n=8) Resin coping data was measured by using a three-dimensional evaluation program. Internal fitness was calculated by RMS (Root Mean Square).It measures mean and Standard Deviation (SD). Results: Three groups are measured $47.11{\pm}(3.08){\mu}m$ total RMS of SLAC group, $48.35({\pm}1.55{\mu}m)$ for total RMS of LAPC group, $43.45{\pm}2.09{\mu}m$ for total RMS of APPC group. Measured value is gradually increased. Followed by autopolymerized pattern resin; Stereolithography resin, Light-activated pattern resin But there were no differences stastically(P>0.321). Conclusion: Evaluation of internal fitness on Resin copings was fabricated by three-ways methods showed that no differences statistically significant and clinically acceptable results.

다양한 삼차원 프린팅 시스템으로 제작된 다이의 정확도 비교 (Accuracy of dies fabricated by various three dimensional printing systems: a comparative study)

  • 백주원;신수연
    • 구강회복응용과학지
    • /
    • 제36권4호
    • /
    • pp.242-253
    • /
    • 2020
  • 목적: 이 연구의 목적은 3D 프린팅으로 제작된 다이의 정확도를 인상재와 치과용 석고를 이용하여 제작한 기존 방식 다이와 비교하고 체적 변화를 평가하여 정확도를 비교하는 것이다. 연구 재료 및 방법: 치과용 모델 하악 우측 제1대구치를 준비하여 스캔한 뒤 polyetherketoneketone (PEKK)으로 기준 다이를 제작한다. 기존 방식 다이는 기준 다이를 polyvinylsiloxane로 인상채득한 뒤 Type IV 치과용 석고를 부었다. 3D 프린팅 시스템의 경우 기준 다이를 스캔하고 3개의 서로 다른 3D 프린터를 이용하여 모델로 변환하였다. 4가지 방법으로 각각 10개의 표본을 만들었다. 3D 표면매칭 소프트웨어를 사용하여 기준 다이와 중첩하였다. 통계 분석을 위해 Kruskal-Wallis test, Mann-Whitney U test를 수행하였다(P < 0.05). 결과: 기준 다이와 비교하여 기존 방식, Stereolithography로 제작된 다이를 제외하고는 각 방식으로 제작된 다이의 체적 변화가 상당히 있었다(P < 0.05). 기존 방식으로 제작된 다이는 3D 프린팅된 다이보다 체적 변화가 가장 적었다(P < 0.05). Stereolithography로 제작된 3D 프린팅 다이는 다른 3D 프린터 중에서 체적 변화가 가장 적었다(P < 0.05). 결론: 기존 방식의 다이는 3D 프린팅 다이보다 더 정확했지만 3D 프린팅 다이는 임상적으로 허용되는 범위 내에 있었다. 따라서 3D 프린팅 다이는 수복물 제작에 사용할 수 있다.

쾌속금형제작을 위한 진공주형과 동용침 분말주조기술에 관한 연구 (Study on Vacuum Casting and Cu Infiltration Powder Casting for Rapid Tooling)

  • 임용관
    • 한국분말재료학회지
    • /
    • 제7권2호
    • /
    • pp.102-109
    • /
    • 2000
  • With the emergence of the 3D CAD, it is possible to create a physical part directly from a digital model by accumulating layers of a given material. The technology is being widely used for checking designs, to create master models for rapid tooling, and for reverse engineering. However, in general, a model created by rapid prototyping technology is made of soft material that cannot be used as mass prouduction hard tool. Newly developed powder casting is suitable for rapid-manufacturing metallic tools. Powder casting can serve as a promising rapid tooling method because of high density characteristics and low dimensional shrinkage below 0.1% during sintering and infiltration. Through this process, we have realized significant time and cost savings eliminating the expense of conventional prototype tooling process.

  • PDF

쾌속조형과 진공주형 및 세라믹 몰드를 이용한 금속 주조 시제품 제작 공정에서의 형상정밀도 변화 (Variations of Form Accuracy in the Process of Metal Cast Prototyping using Rapid prototype, Vacuum casting and Ceramic Mold)

  • 김기대
    • 한국정밀공학회지
    • /
    • 제24권6호
    • /
    • pp.131-137
    • /
    • 2007
  • In metal casting process, it is very difficult to predict the form accuracy of cast part and reduce repeatability error. In this study, the variations of form accuracy were measured in the process of metal cast prototyping, where RP part is manufactured from CAD model in the first, and then, wax part is cast in the vacuum environment using the RP part as master model, and finally metal prototype is cast using ceramic mold and the wax part as pattern. To investigate the variations of form accuracy, the averages and standard deviations of error distribution of the parts measured by 3D scanner were compared. It was observed that the biggest shrinkage is generated during the extraction of wax part in the second step and the biggest deterioration of form accuracy is generated during the metal part casting in the last step.

Accuracy of new implant impression technique using dual arch tray and bite impression coping

  • Lee, Shin-Eon;Yang, Sung-Eun;Lee, Cheol-Won;Lee, Won-Sup;Lee, Su Young
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권4호
    • /
    • pp.265-270
    • /
    • 2018
  • PURPOSE. The purpose of this in vitro study was to evaluate the accuracy of a new implant impression technique using bite impression coping and a dual arch tray. MATERIALS AND METHODS. Two implant fixtures were placed on maxillary left second premolar and first molar area in dentoform model. The model with two fixtures was used as the reference. The impression was divided into 2 groups, n=10 each. In group 1, heavy/light body silicone impression was made with pick up impression copings and open tray. In group 2, putty/light body silicone impression was made with bite impression copings and dual arch tray. The reference model and the master casts with implant scan bodies were scanned by a laboratory scanner. Surface tessellation language (STL) datasets from test groups was superimposed with STL dataset of reference model using inspection software. The three-dimensional deviation between the reference model and impression models was calculated and illustrated as a color-map. Data was analyzed by independent samples T-test of variance at ${\alpha}=.05$. RESULTS. The mean 3D implant deviations of pick up impression group (group 1) and dual arch impression group (group 2) were 0.029 mm and 0.034 mm, respectively. The difference in 3D deviations between groups 1 and 2 was not statistically significant (P=.075). CONCLUSION. Within limitations of this study, the accuracy of implant impression using a bite impression coping and dual arch tray is comparable to that of conventional pick-up impression.