• Title/Summary/Keyword: 3D Master Model

Search Result 69, Processing Time 0.026 seconds

Three-dimensional evaluation of the internal adaptation of single and three-unit fixed dental restoration by CAD/CAM milling system (CAD/CAM 밀링 시스템을 활용한 단일 치관과 3본 교의치의 3D 적합도 평가)

  • Kim, So-Ri;Kim, Chong-Myeong;Kim, Woong-Chul;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.39 no.1
    • /
    • pp.35-42
    • /
    • 2017
  • Purpose: The purpose of this paper was to evaluate the occurrence of errors regarding adaptation by conducting a three-dimensional assessment comparing the bridge type dental restoration after the cutting process, which has multiple abutments, with a single type dental restoration. Methods: By using ten identical files obtained by scanning the master model, thirty designs were created consisting of ten maxillary right first premolars and ten maxillary right first molars with single crown abutments, along with ten bridge designs with the identical abutment. A 5-axis milling machine was used to produce the design file. The produced denture prostheses were scanned using a silicone replica for a STL file. An evaluation was conducted using 3D analysis software on the master model and each of the thirty data files. Results: The RMS value of the pre-molar (14) was $38.4{\pm}4{\mu}m$ for single and $54.7{\pm}6{\mu}m$ for bridge abutment; therefore, a statistically significant difference was observed for single and bridge designs although both shared the same abutment form (P<.05). Also, the RMS value of the molar (16) was $47.6{\pm}2{\mu}m$ and $56.6{\pm}5{\mu}m$ for the single and bridge designs, respectively, thereby presenting a statistically significant difference (P<.05). Conclusion: As a result, dental prosthesis fabricated using the single method presented better internal adaptation outcomes.

Accuracy of Stone Cast Produced by Adjustable Dental Impression Tray (가변형 치과 인상용 트레이로 제작된 모형의 재현성)

  • Park, Kwang-Su;Dong, Jin-Keun;Sim, Hun-Bo;Oh, Sang-Chun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.22 no.4
    • /
    • pp.317-328
    • /
    • 2006
  • Purpose: This study was performed to measure the accuracy of adjustable dental impression trays by a scanning laser three-dimensional digitizer. Materials and Methods: Metal stock tray and adjustable stock trays were used for 40 stone casts(10 casts each) duplicated a resin master model of mandible and maxilla. The type IV dental stone was poured in a allginate impressions and allowed to set for one hour. The casts were digitized using an optical digitizer. The distance between the reference points were measured and analyzed on the graphic image of 3-D graphic software (CATIA version 5.0). The statistical significance of the differences between the groups was determined by a two-way ANOVA. Results: There were no significant differences between the accuracies of the adjustable stock tray and the master model except anterior arch width of the upper arch and the diagonal arch length and arch length(one side) of the lower arch. Conclusion: The adjustable stock trays showed clinically acceptable accuracies of the study casts produced by them.

사각형강목의 끝자루를 이용한 트롤어구의 어획선택성 연구 ( I ) - 사각형강목의 어획선택성 - ( Studies on the Selectivity of the Trawl Net With the Square Mesh Cod-End ( 1 ) - Selectivity of the Square Mesh Cod-End - )

  • Lee, Ju-Hee;Kim, Sam-Kon;Kim, Jin-Kun
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.30 no.3
    • /
    • pp.161-171
    • /
    • 1994
  • Mesh selection analysis for the trawl net were carried out at the Southern Korean Sea and the East China Sea during the 1992-1994 years by the training ship Seabada of the National Fisheries University of Pusan, using A type (51.2mm), B type (70.2mm), C type (77.6mm), D type (88.0mm) square mesh cod-ends. The fishing trials were made using bottom trawl of the trouser type cod-end with cover net. Selection curves and selection parameters were calculated by a logistic model for Sphyraena pinguis, Pampus argenteus, Trachurus japonicus, Pagrus major, Callanthias japonicus, Trichiurus lepturus. The results obtained are summarized as follows: 1. Red barracuda : Selection range and fifty percent selection length in the A type was 115.8mm, 292.8mm, respectively. 2. Harvest fish : Each selection range and fifty percent selection length in the B. C. and D type was 37.7mm, 113.8mm : 40.1mm, 131.7mm and 64.8mm, 148.6mm, respectively. Selection parameters of master curve were : slope, 3.81 : intercept, -6.4. Optimum mesh size was 89.3mm. 3. Horse mackerel : Each selection range and fifty percent selection length in the A, B, C and D type was 43.0mm, 148.3mm : 60.7mm, 183.2mm, 214.5mm and 91.4mm, 254.9mm, respectively. Selection parameters of master curve were : slope 2.30 : intercept, -6.4. Optimum mesh size was 66.8mm. 4. Red seabrem : Selection range and fifty percent selection length in the D type was 42.7mm, 203.4mm, respectively. 5. Yellowsail red bass : Selection range and fifty percent selection length in the A type was 84.0mm, 110.6mm, respectively. 6. Hair tail : Each selection range and fifty percent selection length in the A, B and C type was 59.7mm, 176.0mm : 100.9mm, 250.7mm and 178.6mm, 307.0mm, respectively. Selection parameters of master curve were : slope, 1.54 : intercept, -5.4. Optimum mesh size was 57.5mm.

  • PDF

사각형강목의 끝자루를 이용한 트롤어구의 어획선택성 연구 ( 2 ) - 다이아몬드형강목과 사각형강목의 선택성비교 - ( Studies on the Selectivity of the Trawl Net With the Square Mesh Cod-End ( 2 ) - Comparison of Diamond and Square Mesh Cod-End - )

  • Kim, Sam-Kon;Lee, Ju-Hee;Park , Jeong-Sik
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.30 no.3
    • /
    • pp.172-181
    • /
    • 1994
  • The mesh selectivity of diamond and suare mesh cod-ends at the Southern Korean Sea and the East China Sea were compared for Pampus argenteus, Trachurus japonicus, Trichiurus lepturus. Selection trials were carried out using diamond and square mesh cod-end by trouser type cod-end with cover net. of which the mesh cod-end has four types : A(51.2mm), B(70.2mm), C(77.6mm), D(88.0mm). Selection curves and selection parameters were calculated using a logistic model. The results obained are summarized as follows : 1. Harvest fish : In B. C and D type selection range and fifty percent selection length of the square mesh were about 21mm, 11mm : 12mm, 18mm and 34mm, 5mm higher than those of the diamond mesh, respectively. Selection factor of master curve for the diamond mesh was 1.54 and for the square mesh was 1.68. The optimum mesh size for the diamond mesh was 97.4mm and for the square mesh was 89.3mm, the difference was 8.1mm. 2. Horse mackerel : In A type, selection range was nearly the same for the diamond and the square mesh, but fifty percent selection length of the square mesh was 43mm higher than the diamond mesh. In B. C and D type, selection range and fifty percent selection length of the square mesh were about 6mm, 3mm : 24mm, 21mm and 11mm, 42mm higher than those of the diamond mesh, respectively. Selection factor of master curve for the diamond mesh was 2.37, for the square mesh was 2.77. The optimum mesh size for the diamond mesh was 78.1mm and for the square mesh was 66.8mm, the difference was 11.3mm. 3. Hair tail : In A, B and C type, selection range of the square mesh was about 34mm, 8mm, 60mm higher than those of the diamond mesh. Fifty percent selection length for the diamond mesh was about 5mm, 7mm, 8mm higher than that of the square mesh. Selection factor of master curve for the diamond mesh was 3.11, for the square mesh was 3.48. The optimum mesh size for the diamond mesh was 64.3mm and for the square mesh was 57.5mm, the difference was 6.8mm.

  • PDF

Bistable Domain Wall Configuration in a Nanoscale Magnetic Disc: A Model for an Inhomogeneous Ferromagnetic Film

  • Venus D.
    • Journal of Magnetics
    • /
    • v.10 no.3
    • /
    • pp.113-117
    • /
    • 2005
  • Some polycrystalline ferromagnetic mms are composed of continuously connected nanometer scale islands with random crystallite orientations. The nanometer perturbations of the mm introduce a large number of nearly degenerate local field configurations that are indistiguishable on a macroscopic scale. As a first step, this situation is modelled as a thin ferromagnetic disc coupled by exchange and dipole interactions to a homogeneous ferromagnetic plane, where the disc and plane have different easy axes. The model is solved to find the partial $N\acute{e}el$ domain walls that minimize the magnetic energy. The two solutions give a bistable configuration that, for appropriate geometries, provides an important microsopic ferromagnetic degree of freedom for the mm. These results are used to interpret recent measurements of exchange biased bilayer films.

Assessment of internal fitness on resin copings fabricated by 3 - ways methods: Three - dimensional analysis (세 가지 방식으로 제작된 레진코핑의 내면적합성 평가: 3차원적 분석)

  • Kang, Seen-young;Park, Jin-Young;Kim, Dong-Yeon;Kim, Woong-Chul
    • Journal of Technologic Dentistry
    • /
    • v.39 no.1
    • /
    • pp.17-24
    • /
    • 2017
  • Purpose: The purpose of this study was to evaluate the internal fitness of the resin coping that was fabricated by the traditional and Digital manufacturing methods through 3-dimensional analysis. Methods: maxillary right second molar was chosen implant master model. Custom-built impression trays were manufactured. After screwing the pick-up impression coping onto the master cast, impressions were made with silicone impression. The Working model was then made with type IV stone. The coping was fabricated: SLAC group (n=8), APPC group (n=8), LAPC group (n=8) Resin coping data was measured by using a three-dimensional evaluation program. Internal fitness was calculated by RMS (Root Mean Square).It measures mean and Standard Deviation (SD). Results: Three groups are measured $47.11{\pm}(3.08){\mu}m$ total RMS of SLAC group, $48.35({\pm}1.55{\mu}m)$ for total RMS of LAPC group, $43.45{\pm}2.09{\mu}m$ for total RMS of APPC group. Measured value is gradually increased. Followed by autopolymerized pattern resin; Stereolithography resin, Light-activated pattern resin But there were no differences stastically(P>0.321). Conclusion: Evaluation of internal fitness on Resin copings was fabricated by three-ways methods showed that no differences statistically significant and clinically acceptable results.

Accuracy of dies fabricated by various three dimensional printing systems: a comparative study (다양한 삼차원 프린팅 시스템으로 제작된 다이의 정확도 비교)

  • Baek, Ju Won;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.4
    • /
    • pp.242-253
    • /
    • 2020
  • Purpose: The aim of this study was to compare the accuracy of dies fabricated using 3D printing system to conventional method and to evaluate overall volumetric changes by arranging the superimposed surfaces. Materials and Methods: A mandibular right first molar from a dental model was prepared, scanned and fabricated with composites of polyetherketoneketone (PEKK). Master dies were classified into 4 groups. For the conventional method, the impression was taken with polyvinylsiloxane and the impression was poured with Type IV dental stone. For the 3D printing, the standard die was scanned and converted into models using three different 3D printers. Each of four methods was used to make 10 specimens. Scanned files were superimposed with the standard die by using 3D surface matching software. For statistical analysis, Kruskal-Wallis test and Mann-Whitney U test were done (P < 0.05). Results: Compared to the standard model, the volumetric changes of dies fabricated by each method were significantly different except the models fabricated by conventional method and 3D printer of Stereolithography (P < 0.05). The conventional dies showed the lowest volumetric change than 3D printed dies (P < 0.05). 3D printed dies fabricated by Stereolithography showed the lowest volumetric change among the different 3D printers (P < 0.05). Conclusion: The conventional dies were more accurate than 3D printed dies, though 3D printed dies were within clinically acceptable range. Thus, 3D printed dies can be used for fabricating restorations.

Study on Vacuum Casting and Cu Infiltration Powder Casting for Rapid Tooling (쾌속금형제작을 위한 진공주형과 동용침 분말주조기술에 관한 연구)

  • 임용관
    • Journal of Powder Materials
    • /
    • v.7 no.2
    • /
    • pp.102-109
    • /
    • 2000
  • With the emergence of the 3D CAD, it is possible to create a physical part directly from a digital model by accumulating layers of a given material. The technology is being widely used for checking designs, to create master models for rapid tooling, and for reverse engineering. However, in general, a model created by rapid prototyping technology is made of soft material that cannot be used as mass prouduction hard tool. Newly developed powder casting is suitable for rapid-manufacturing metallic tools. Powder casting can serve as a promising rapid tooling method because of high density characteristics and low dimensional shrinkage below 0.1% during sintering and infiltration. Through this process, we have realized significant time and cost savings eliminating the expense of conventional prototype tooling process.

  • PDF

Variations of Form Accuracy in the Process of Metal Cast Prototyping using Rapid prototype, Vacuum casting and Ceramic Mold (쾌속조형과 진공주형 및 세라믹 몰드를 이용한 금속 주조 시제품 제작 공정에서의 형상정밀도 변화)

  • Kim, Gi-Dae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.6
    • /
    • pp.131-137
    • /
    • 2007
  • In metal casting process, it is very difficult to predict the form accuracy of cast part and reduce repeatability error. In this study, the variations of form accuracy were measured in the process of metal cast prototyping, where RP part is manufactured from CAD model in the first, and then, wax part is cast in the vacuum environment using the RP part as master model, and finally metal prototype is cast using ceramic mold and the wax part as pattern. To investigate the variations of form accuracy, the averages and standard deviations of error distribution of the parts measured by 3D scanner were compared. It was observed that the biggest shrinkage is generated during the extraction of wax part in the second step and the biggest deterioration of form accuracy is generated during the metal part casting in the last step.

Accuracy of new implant impression technique using dual arch tray and bite impression coping

  • Lee, Shin-Eon;Yang, Sung-Eun;Lee, Cheol-Won;Lee, Won-Sup;Lee, Su Young
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.4
    • /
    • pp.265-270
    • /
    • 2018
  • PURPOSE. The purpose of this in vitro study was to evaluate the accuracy of a new implant impression technique using bite impression coping and a dual arch tray. MATERIALS AND METHODS. Two implant fixtures were placed on maxillary left second premolar and first molar area in dentoform model. The model with two fixtures was used as the reference. The impression was divided into 2 groups, n=10 each. In group 1, heavy/light body silicone impression was made with pick up impression copings and open tray. In group 2, putty/light body silicone impression was made with bite impression copings and dual arch tray. The reference model and the master casts with implant scan bodies were scanned by a laboratory scanner. Surface tessellation language (STL) datasets from test groups was superimposed with STL dataset of reference model using inspection software. The three-dimensional deviation between the reference model and impression models was calculated and illustrated as a color-map. Data was analyzed by independent samples T-test of variance at ${\alpha}=.05$. RESULTS. The mean 3D implant deviations of pick up impression group (group 1) and dual arch impression group (group 2) were 0.029 mm and 0.034 mm, respectively. The difference in 3D deviations between groups 1 and 2 was not statistically significant (P=.075). CONCLUSION. Within limitations of this study, the accuracy of implant impression using a bite impression coping and dual arch tray is comparable to that of conventional pick-up impression.