• Title/Summary/Keyword: 3D (3Dimensional)

Search Result 6,370, Processing Time 0.059 seconds

Three-dimensional image processing using integral imaging method (집적 영상법을 이용한 3차원 영상 정보 처리)

  • Min, Seong-Uk
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2005.07a
    • /
    • pp.150-151
    • /
    • 2005
  • Integral imaging is one of the three-dimensional(3D) display methods, which is an autostereoscopic method. The integral imaging system can provide volumetric 3D image which has both vertical and horizontal parallaxes. The elemental image which is obtained in the pickup process by lens array has the 3D information of the object and can be used for the depth perception and the 3D correlation. Moreover, the elemental image which represents a cyber-space can be generated by computer process.

  • PDF

Multi-Detector Row CT of the Central Airway Disease (Multi-Detector Row CT를 이용한 중심부 기도 질환의 평가)

  • Kang, Eun-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.55 no.3
    • /
    • pp.239-249
    • /
    • 2003
  • Multi-detector row CT (MDCT) provides faster speed, longer coverage in conjunction with thin slices, improved spatial resolution, and ability to produce high quality muliplanar and three-dimensional (3D) images. MDCT has revolutionized the non-invasive evaluation of the central airways. Simultaneous display of axial, multiplanar, and 3D images raises precision and accuracy of the radiologic diagnosis of central airway disease. This article introduces central airway imaging with MDCT emphasizing on the emerging role of multiplanar and 3D reconstruction.

Three-Dimensional Surface Imaging is an Effective Tool for Measuring Breast Volume: A Validation Study

  • Lee, Woo Yeon;Kim, Min Jung;Lew, Dae Hyun;Song, Seung Yong;Lee, Dong Won
    • Archives of Plastic Surgery
    • /
    • v.43 no.5
    • /
    • pp.430-437
    • /
    • 2016
  • Background Accurate breast volume assessment is a prerequisite to preoperative planning, as well as intraoperative decision making in breast reconstruction surgery. The use of three-dimensional surface imaging (3D scanning) to assess breast volume has many advantages. However, before employing 3D scanning in the field, the tool's validity should be demonstrated. The purpose of this study was to confirm the validity of 3D-scanning technology for evaluating breast volume. Methods We reviewed the charts of 25 patients who underwent breast reconstruction surgery immediately after total mastectomy. Breast volumes using the Axis Three 3D scanner, water-displacement technique, and magnetic resonance imaging (MRI) were obtained bilaterally in the preoperative period. During the operation, the tissue removed during total mastectomy was weighed and the specimen volume was calculated from the weight. Then, we compared the volume obtained from 3D scanning with those obtained using the water-displacement technique, MRI, and the calculated volume of the tissue removed. Results The intraclass correlation coefficient (ICC) of breast volumes obtained from 3D scanning, as compared to the volumes obtained using the water-displacement technique and specimen weight, demonstrated excellent reliability. The ICC of breast volumes obtained using 3D scanning, as compared to those obtained by MRI, demonstrated substantial reliability. Passing-Bablok regression showed agreement between 3D scanning and the water-displacement technique, and showed a linear association of 3D scanning with MRI and specimen volume, respectively. Conclusions When compared with the classical water-displacement technique and MRI-based volumetry, 3D scanning showed significant reliability and a linear association with the other two methods.

Vignetting Dimensional Geometric Models and a Downhill Simplex Search

  • Kim, Hyung Tae;Lee, Duk Yeon;Choi, Dongwoon;Kang, Jaehyeon;Lee, Dong-Wook
    • Current Optics and Photonics
    • /
    • v.6 no.2
    • /
    • pp.161-170
    • /
    • 2022
  • Three-dimensional (3D) geometric models are introduced to correct vignetting, and a downhill simplex search is applied to determine the coefficients of a 3D model used in digital microscopy. Vignetting is nonuniform illuminance with a geometric regularity on a two-dimensional (2D) image plane, which allows the illuminance distribution to be estimated using 3D models. The 3D models are defined using generalized polynomials and arbitrary coefficients. Because the 3D models are nonlinear, their coefficients are determined using a simplex search. The cost function of the simplex search is defined to minimize the error between the 3D model and the reference image of a standard white board. The conventional and proposed methods for correcting the vignetting are used in experiments on four inspection systems based on machine vision and microscopy. The methods are investigated using various performance indices, including the coefficient of determination, the mean absolute error, and the uniformity after correction. The proposed method is intuitive and shows performance similar to the conventional approach, using a smaller number of coefficients.

The Significance of 3-Dimensional Imaging in Tracheal Stenosis (기관협착증에서 3차원적 영상 진단의 의의)

  • 정동학;봉정표;이운우;노정래;성기준
    • Korean Journal of Bronchoesophagology
    • /
    • v.1 no.1
    • /
    • pp.82-93
    • /
    • 1995
  • Three-dimensional reconstruction of computed tomographic image(3D CT) is a well-established imaging modality which has been investigated in various clinical settings. It is commonly performed in case of congenital or developmental abnormalities, and traumatic fracture of skull and face that requires reconstruction of osseous structure. However reporting the 3D CT in laryngeal or tracheal stenosis is rare and its results are obscure. The authors performed 3D CT in six cases of tracheal stenosis and found diagnostic value of 3D CT. A Comparision of diagnostic information obtained from plain X-ray, 2D CT and 3D CT has performed in total six cases of tracheal stenosis. Surgical treatment of the tracheal stenosis was following in these cases : tracheal end to end anastomosis In 1 case, laryngotracheal end to end anastomosis in 2 cases. 3D CT information was compared with operative finding. In two of six cases, satisfactory information was not obtained from 3D CT in evaluating an exact stenosis of trachea. Future, it will be helped in evaluating of tracheal stenosis by 3D CT.

  • PDF

Study of KINECT based 3D Holographic and Gesture (KINECT 기반 3D 홀로그래픽과 제스처에 대한 연구)

  • Jiang, Zhou;Seo, Laiwon;Roh, Changbae
    • Journal of Digital Contents Society
    • /
    • v.14 no.4
    • /
    • pp.411-417
    • /
    • 2013
  • Two-dimensional image processing method and tools Rigi then developed a report prepared by a variety of video and three-dimensional images are increasing demands for navigation. The hard part to experience in the real world experience in the virtual environment, and has the purpose to take advantage of. This is a system that provides a simple 3D background, but everyday actions that can control the system with the needs of an instinctive interface technology means. The purpose of this study a variety of human behavior using the Kinect device in action close to the three-dimensional technology to develop a new navigation control is Kinect Holography and 3D images using the input data so that you have the linkage is to design the system.

Three-Dimensional Vibration Analysis of Cantilevered Laminated Composite Plates (캔틸레버 복합 적층판의 3차원 진동해석)

  • 김주우;정희영
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.14 no.3
    • /
    • pp.299-308
    • /
    • 2001
  • This paper presents the three-dimensional (3-D) study of the natural vibration of cantilevered laminated composite plates. The Ritz method is used to obtain stationary values of the associated Lagrangian functional with displacements approximated by mathematically complete polynomials satisfying the boundary conditions at the clamped edge exactly. The accuracy of the 3-D model is established through a convergence study of non-dimensional frequencies followed by a comparison of the converged 3-D solutions with analytical and experimental findings in the existing literature. A wide scope of 3-D frequency results explain the influence of a number of geometrical and material parameters for cantilevered laminated plates, namely aspect ratio (a/b), width-to-thickness ratio (a/h), orthotropy of material, number of plies (NP), fiber orientation angle(θ), and stacking sequence.

  • PDF

Three-Dimensional Map System Using Integral Imaging Technique (집적 영상 기술을 이용한 3차원 지도 시스템)

  • Cho, Myungjin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.11
    • /
    • pp.2799-2804
    • /
    • 2014
  • In this paper, we suggest three-dimensional information extraction map system using integral imaging technique. Integral imaging can record multiple elemental images with different perspectives using a 2D image acquisition device with lenslet array. Using these images, integral imaging can obtain 3D information and display 3D image. In this paper, the position difference between elemental images can be obtained using summation of absolute difference (SAD), and then 3D information can be extracted. Therefore, this technique can find the height information of 3D objects.

Investigation of the electrical characteristics of monolithic 3-dimensional static random access memory consisting of feedback field-effect transistor (피드백 전계 효과 트랜지스터로 구성된 모놀리식 3차원 정적 랜덤 액세스 메모리 특성 조사)

  • Oh, Jong Hyeok;Yu, Yun Seop
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.10a
    • /
    • pp.115-117
    • /
    • 2022
  • The electrical characteristics of the monolithic 3-dimensional static random access memory consisting of a feedback field-effect transistor (M3D-SRAM-FBFET) was investigated using technology computer-aided design (TCAD). The N-type FBFET and N-type MOSFET are designed with fully depleted silicon on insulator (FDSOI), and those are located at bottom and top tiers, respectively. For the M3D-SRAM-FBFET, as the supply voltage decreased from 1.9 V to 1.6 V, the reading on-current decreased approximately 10 times.

  • PDF

Method for Supplementing Single-View Resolution of Multiview Autostereoscopic Three-Dimensional Display Using Plate Beam Splitter

  • Kim, Hyun-Woo;Cho, Myungjin;Lee, Min-Chul
    • Journal of information and communication convergence engineering
    • /
    • v.19 no.2
    • /
    • pp.108-113
    • /
    • 2021
  • Multiview autostereoscopic three-dimensional (MA3D) displays have the disadvantage that the single-view resolution decreases as the number of views increases. Furthermore, the resolution of MA3D displays is relatively degraded, even though the resolution of two-dimensional displays has increased recently. Therefore, it is unattractive to consumers, and the single-view resolution enhancement of MA3D displays is required. In this study, we developed a method for supplementing the single-view resolution of MA3D displays using a plate beam splitter that can show two MA3D displays simultaneously. By applying our proposed method, the resolution of a single view can increase, and the visual obstruction by the optical plate, which is a problem for MA3D displays, can be solved. In addition, an MA3D display was optically designed and fabricated using a parallax barrier. Finally, the experimental optical results obtained using the proposed method and the only MA3D display were compared.