• Title/Summary/Keyword: 3D스캔

Search Result 412, Processing Time 0.03 seconds

All-on-6 implant fixed prosthesis restoration with full-digital system on edentulous patient: A case report (무치악 환자에서 완전 디지털 시스템을 활용한 All-on-6 임플란트 고정성 보철물 수복 증례)

  • Lee, SeungJin;Jeong, Seung-Mi;Chung, Chae-Heon;Fang, YiQin;Choi, Byung-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.4
    • /
    • pp.497-507
    • /
    • 2021
  • All-on-six concept can be used as one of the treatment options to maximize the use of available residual alveolar bone for implant-supported fixed prosthesis on edentulous patients. But this process is complex and cumbersome. Digital system can be used at multiple steps, from implantation to prosthetic restoration, to overcome this shortcoming. In this case of a maxillary edentulous patient aged 76, digital system was used for restoration of 1-piece design, screw retained fixed prosthesis from diagnosis, implant surgery to fabrication of provisional and final prosthesis. For preoperative diagnosis and treatment planning stage, intra-oral information of a patient was digitalized by direct intra-oral scan. Surgical guide and immediate provisional prosthesis was designed based on this digitalized data. Patient's inconvenience was minimized by applying immediate provisional prosthesis, which was delicately fabricated according to the location data of six implants on most suitable residual alveolar bone. Then, final prosthesis was designed and fabricated going through new interim prosthesis which was newly designed and fabricated, considering patient's requests, stable vertical dimension and occlusion, and esthetic factors using digital system. We hereby report a case successfully applying digital system to multiple steps including implant surgery to fabricating prosthesis, to simplify existing complicated implant treatment procedure to an edentulous patient.

Rehabilitation of the edentulous patient with implant overdenture using CAD-CAM denture system: A case report (CAD-CAM으로 제작된 임플란트 피개의치를 이용한 무치악 환자의 보철 수복 증례)

  • Lee, Han-na;Shim, Ji-Suk;Lee, Jeong-Yol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.4
    • /
    • pp.374-381
    • /
    • 2022
  • This case report introduces a 74-year-old male patient who visited retention deficiency of the mandibular implant overdenture, which was fabricated 20 years ago. When the existing dentures were used, the vertical dimension was reduced, the maxillary complete denture lacked lip support and retention, and the mandibular overdenture lacked clip retention due to damage to the bar attachment. After removing the damaged bar attachment, it was replaced with a ball attachment, and impressions were taken using the DENTCATM Tray and then the vertical dimension was measured. The gothic arch tracing was performed to record the centric relation. Obtained impressions were scanned and the shape of final dentures was designed using software and try-in dentures were fabricated using 3D printer. After evaluating the occlusal plane, occlusal relationship, facial shape, and pronunciation using the try-in dentures, the bite registration was recorded, and the final denture was manufactured based on this. The inner surface of the denture was adjusted and bilateral balanced occlusion was formed, and the housing was connected to the mandibular denture by a direct method. This case reports have shown satisfactory resultin recovering improved retention and esthetic outcome by increasing the vertical dimension and the lip support using CAD-CAM technique and the ball attachment.

Fracture Strength and Translucency of CAD/CAM Zirconia Crown for Primary Anterior Tooth (CAD/CAM으로 제작한 유전치 지르코니아 전장관의 두께에 따른 파절강도와 반투명도 비교)

  • Ong, Seung-Hwan;Kim, Jongsoo;Kim, Jongbin;Shin, Jisun;Yoo, Seunghoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.47 no.2
    • /
    • pp.205-212
    • /
    • 2020
  • The purpose of this study is to evaluate the validity of primary anterior zirconia crown made with Computer Aided Design/Computer Aided Manufacturing (CAD/CAM) technology by analyzing fracture strength and translucency parameter. Zirconia crown was designed with CAD software, using 3D scanned data of #61 tooth model. Crown fabrication was performed with CAM machine using zirconia block. Zirconia crowns were divided into 3 groups according to thickness(0.3, 0.5, and 0.7 mm), and fracture strength was compared with 1.0 mm thickness of resin strip crown. The compressive force was applied with universal testing machine at 30° along the incisal edge at increments of 1 mm/min. For translucency evaluation, 0.3, 0.5, and 0.7 mm thickness of zirconia specimens were fabricated and translucency was measured with spectrophotometer. Among zirconia groups, there was a significant increase in fracture strength as thickness increased (p < 0.05). The fracture strength of zirconia crown was significantly higher than resin strip crown in all groups (p < 0.05). Translucency parameter was highest in 0.3 mm group, and significantly decreased as thickness increased to 0.5 and 0.7 mm (p < 0.05). Thin primary anterior zirconia crown can be designed and fabricated according to individual needs by using CAD/CAM. Restoration with thin crown would reduce the amount of tooth reduction, risk of pulp exposure, and make more esthetic restoration possible.

A Study on the Recreated Experiment and Casting Method of Ancient Iron Seated Buddha by Spilt Casting Method (분할주조법을 이용한 고대 철불의 재현실험 및 주조법 연구)

  • Park, June Yeong;Jung, Da Yeon;Han, Min Su;Lee, Joo Wan;Cho, Nam Chul
    • Journal of Conservation Science
    • /
    • v.38 no.3
    • /
    • pp.234-242
    • /
    • 2022
  • The study aimed to investigate the split casting method based on the recreation of the iron-seated Buddha (ISB) statue (number 1971) in the Chuncheon Museum. The statue was designed using three-dimensional scan data and reduced to half-size. Using the existing research results, the ISB statue was created by mold production and split casting. The mold was prepared by mixing sand and clay at a ratio of 3:4 and 1:3 on the outside and inside, respectively, and then casting was done. Various casting defects were observed in the ISB casting and similar shapes were seen. The casting defects included veining or finning, misrun, open or external shrinkage, surface or subsurface blowholes, surface pinholes, and shift. The microstructures were identified as branch-shaped dendrite and pearlite organizations, and black graphite was observed between the cementite organizations. The study findings may be relevant in exploring traditional casting and manufacturing techniques of ISB and may aid in the production of the original form of ISB.

The Occurrence of Renal Scarring in Children with Unilateral Vesicoureteral Reflux (일측성 방광 요관 역류 환아에서 신반흔의 발생)

  • Lee, Tae Ho;Son, Mi Ran;Byun, Soon Ok;Moon, Jung Woong
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.9
    • /
    • pp.998-1003
    • /
    • 2005
  • Purpose : We evaluated the occurrence of renal scarring in children with unilateral vesicoureteral reflux(VUR), and the relationships between renal scar formation and risk factors such as VUR, duration of fever, acute-phase reactant, age, and sex. Methods : We retrospectively analyzed the data of 35 children newly diagnosed with unilateral vesicoureteral reflux after urinary tract infection(UTI) in Wallace Memorial Baptist Hospital between January 1996 and December 2004. Ultrasonography, Erythrocyte sedimentation rate(ESR), and C-reactive protein(CRP) were performed initially. Voiding cystourethrography(VCUG) was performed 1 to 3 weeks after treatment with UTI. $^{99m}Tc$-dimercaptosuccinic acid(DMSA) scan was performed 4 to 6 months after treatment. Results : Scintigraphic renal damage was present in 29 percent of the refluxing and in 3 percent of the nonrefluxing kidneys(P<0.05). The severity of VUR was significantly correlated with renal scar formation(P<0.05). The duration of fever before treatmen($5.0{\pm}1.3$ vs $2.6{\pm}1.3$) and prolonged fever of over 5 days were significantly different between renal scar group and non-renal scar group(P<0.05). ESR($56.3{\pm}23.8$ vs $27.9{\pm}18.1mm/hr$, P<0.05) and CRP($12.8{\pm}7.3$ vs $3.9{\pm}3.8mg/dL$, P<0.05) at the diagnosis of UTI in the renal scar group were higher, compared to those of the non-renal scar group. There were no significant differences in age and sex between the two groups. Conclusion : The presence and grade of VUR, the duration of fever before treatment, prolonged fever over 5 days, ESR, and CRP were risk factors for renal scarring, irrespective of age and sex. Diagnosis and management of VUR, in children with UTI, is important to prevent renal scars.

Development of an Automatic 3D Coregistration Technique of Brain PET and MR Images (뇌 PET과 MR 영상의 자동화된 3차원적 합성기법 개발)

  • Lee, Jae-Sung;Kwark, Cheol-Eun;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Park, Kwang-Suk
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.5
    • /
    • pp.414-424
    • /
    • 1998
  • Purpose: Cross-modality coregistration of positron emission tomography (PET) and magnetic resonance imaging (MR) could enhance the clinical information. In this study we propose a refined technique to improve the robustness of registration, and to implement more realistic visualization of the coregistered images. Materials and Methods: Using the sinogram of PET emission scan, we extracted the robust head boundary and used boundary-enhanced PET to coregister PET with MR. The pixels having 10% of maximum pixel value were considered as the boundary of sinogram. Boundary pixel values were exchanged with maximum value of sinogram. One hundred eighty boundary points were extracted at intervals of about 2 degree using simple threshold method from each slice of MR images. Best affined transformation between the two point sets was performed using least square fitting which should minimize the sum of Euclidean distance between the point sets. We reduced calculation time using pre-defined distance map. Finally we developed an automatic coregistration program using this boundary detection and surface matching technique. We designed a new weighted normalization technique to display the coregistered PET and MR images simultaneously. Results: Using our newly developed method, robust extraction of head boundary was possible and spatial registration was successfully performed. Mean displacement error was less than 2.0 mm. In visualization of coregistered images using weighted normalization method, structures shown in MR image could be realistically represented. Conclusion: Our refined technique could practically enhance the performance of automated three dimensional coregistration.

  • PDF

Is routine screening examination necessary for detecting thromboembolism in childhood nephrotic syndrome? (소아 신증후군 환자에서 혈전증 검색을 위해screening 검사가 필요한가?)

  • Kim, Mun Sub;Koo, Ja Wook;Kim, Soung Hee
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.7
    • /
    • pp.736-741
    • /
    • 2008
  • Purpose : The incidence of thromboembolic episodes in children with nephrotic syndrome (NS) is low; however, these episodes are often severe. Moreover, both pulmonary thromboembolism (PTE) and renal vein thrombosis (RVT) rarely show clinical symptoms. This study was performed to determine the benefits of routine screening in the detection of thrombosis in childhood NS. Methods : Among 62 children with nephrotic syndrome, a total of 54 children (43 males, 11 females) were included in this study. When the patients experienced their first NS episode, we performed renal Doppler ultrasonography in order to detect RVT. To rule out the possibility of PTE, a lung perfusion scan was performed. Computed tomographic (CT) pulmonary angiography was recommended to patients who showed possible signs of PTE. All patients were evaluated for clinical signs of thrombosis, biochemical indicators of renal disease, as well as clotting and thrombotic parameters. Results : RVT or related clinical symptoms were not observed in any children. Based on the findings of the lung perfusion scans, 15 patients (27.8%) were observed with as a high probability of PTE. We were able to perform a CT pulmonary angiography only on 12 patients, and 5 patients were diagnosed with PTE (prevalence 8.1%). The serum fibrinogen level in the group with PTE was significantly higher ($776.7{\pm}382.4mg/dL$, P<0.05) than that in the group without PTE, and other parameters were not significantly different between each group. Conclusion : Further studies are required for clarifying the role of renal Doppler ultrasonography for the detection of RVT in NS. Children with NS who developed non-specific respiratory symptoms should be evaluated for the diagnosis of PTE. In the management of NS, a lung perfusion scan should be performed at the time of the initial episode of NS regardless of the pulmonary symptoms, since patients having PTE are either often asymptomatic, or present with nonspecific symptoms.

The Study on New Radiating Structure with Multi-Layered Two-Dimensional Metallic Disk Array for Shaping flat-Topped Element Pattern (구형 빔 패턴 형성을 위한 다층 이차원 원형 도체 배열을 갖는 새로운 방사 구조에 대한 연구)

  • 엄순영;스코벨레프;전순익;최재익;박한규
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.7
    • /
    • pp.667-678
    • /
    • 2002
  • In this paper, a new radiating structure with a multi-layered two-dimensional metallic disk array was proposed for shaping the flat-topped element pattern. It is an infinite periodic planar array structure with metallic disks finitely stacked above the radiating circular waveguide apertures. The theoretical analysis was in detail performed using rigid full-wave analysis, and was based on modal representations for the fields in the partial regions of the array structure and for the currents on the metallic disks. The final system of linear algebraic equations was derived using the orthogonal property of vector wave functions, mode-matching method, boundary conditions and Galerkin's method, and also their unknown modal coefficients needed for calculation of the array characteristics were determined by Gauss elimination method. The application of the algorithm was demonstrated in an array design for shaping the flat-topped element patterns of $\pm$20$^{\circ}$ beam width in Ka-band. The optimal design parameters normalized by a wavelength for general applications are presented, which are obtained through optimization process on the basis of simulation and design experience. A Ka-band experimental breadboard with symmetric nineteen elements was fabricated to compare simulation results with experimental results. The metallic disks array structure stacked above the radiating circular waveguide apertures was realized using ion-beam deposition method on thin polymer films. It was shown that the calculated and measured element patterns of the breadboard were in very close agreement within the beam scanning range. The result analysis for side lobe and grating lobe was done, and also a blindness phenomenon was discussed, which may cause by multi-layered metallic disk structure at the broadside. Input VSWR of the breadboard was less than 1.14, and its gains measured at 29.0 GHz. 29.5 GHz and 30 GHz were 10.2 dB, 10.0 dB and 10.7 dB, respectively. The experimental and simulation results showed that the proposed multi-layered metallic disk array structure could shape the efficient flat-topped element pattern.

The Diagnosis and Treatment of Osteoporosis (골다공증의 진단과 치료)

  • Moon, Jun-Sung;Won, Kyu-Chang
    • Journal of Yeungnam Medical Science
    • /
    • v.25 no.1
    • /
    • pp.19-30
    • /
    • 2008
  • Osteoporosis, a disease characterized by low bone mass and microarchitectural deterioration of bone tissue leading to enhanced bone fragility and fracture risk, is a major public health problem. The diagnostic methods for osteoporosis include simple radiography, bone scan, DXA (Dual energy X-ray Absortiometry) and biochemical markers of bone turnover. Optimal treatment and prevention of osteoporosis require modification of risk factors, particularly smoking cessation, adequate physical activity, and attention to diet, in addition to pharmacologic intervention. The estrogens and raloxifene both prevent bone loss in postmenopausal women, and the estrogens probably also decrease the risk of first fracture. There is good evidence that raloxifene prevents further fractures in postmenopausal women who already have had fractures and some evidence that estrogen does as well. Bisphosphonate prevents bone loss and reduces fractures in healthy and osteoporotic postmenopausal women and in osteoporotic men as well. Risedronate is more potent and has fewer side effects than alendronate and reduces the incidence of fractures in osteoporotic women. Calcitonin increases bone mineral density in early postmenopausal women and men with idiopathic osteoporosis, and also reduces the risk of new fractures in osteoporotic women. All of the agents discussed above prevent bone resorption, whereas teriparatide and strontium increase bone formation and are effective in the treatment of osteoporotic women and men. New avenues for targeting osteoporosis will emerge as our knowledge of the regulatory mechanisms of bone remodeling increases, although issues of tissue specificity may remain to be addressed.

  • PDF

Ex vivo Morphometric Analysis of Coronary Stent using Micro-Computed Tomography (미세단층촬영기법을 이용한 관상동맥 스텐트의 동물 모델 분석)

  • Bae, In-Ho;Koh, Jeong-Tae;Lim, Kyung-Seob;Park, Dae-Sung;Kim, Jong-Min;Jeong, Myung-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.2
    • /
    • pp.93-98
    • /
    • 2012
  • Micro-computed tomography (microCT) is an important tool for preclinical vascular imaging, with micron-level resolution. This non-destructive means of imaging allows for rapid collection of 2D and 3D reconstructions to visualize specimens prior to destructive analysis such as pathological analysis. Objectives. The aim of this study was to suggest a method for ex vivo, postmortem examination of stented arterial segments with microCT. And ex vivo evaluation of stents such as bare metal or drug eluting stents on in-stent restenosis (ISR) in rabbit model was performed. The bare metal stent (BMS) and drug eluting stent (DES, paclitaxel) were implanted in the left or right iliac arteries alternatively in eight New Zealand white rabbits. After 4 weeks of post-implantation, the part of iliac arteries surrounding the stent were removed carefully and processed for microCT. Prior to microCT analysis, a contrast medium was loaded to lumen of stents. All samples were subjected to an X-ray source operating at 50 kV and 200 ${\mu}A$ by using a 3D isotropic resolution. The region of interest was traced and measured by CTAN analytical software. Objects being exposed to radiation had different Hounsfield unit each other with values of approximately 1.2 at stent area, 0.12 ~ 0.17 at a contrast medium and 0 ~ 0.06 at outer area of stent. Based on above, further analyses were performed. As a result, the difference of lengths and volumes between expanded stents, which may relate to injury score in pathological analysis, was not different significantly. Moreover, ISR area of BMS was 1.6 times higher than that of DES, indicating that paclitaxel has inhibitory effect on cell proliferation and prevent infiltration of restenosis into lumen of stent. And ISR area of BMS was higher ($1.52{\pm}0.48mm^2$) than that of DES ($0.94{\pm}0.42mm^2$), indicating that paclitaxel has inhibitory effect on cell proliferation and prevent infiltration of restenosis into lumen of stent. Though it was not statistically significant, it showed that the extent of neointema of mid-region of stents was relatively higher than that of anterior and posterior region in parts of BMS as showing cross-sectional 2-D image. suggest that microCT can be utilized as an accessorial tool for pathological analysis.