• Title/Summary/Keyword: 3D상관

Search Result 1,886, Processing Time 0.038 seconds

Subjective Video Quality Comparison of 3D Display Monitors (3D 디스플레이 모니터의 주관적 화질 상관도 비교)

  • Youn, Sungwook;Ok, Jiheon;Yim, Donghyun;Han, Taehwan;Lee, Chulhee
    • Journal of Broadcast Engineering
    • /
    • v.18 no.3
    • /
    • pp.416-424
    • /
    • 2013
  • Recently, efforts have been made to develop international standards related to 3DTV quality assessment underway in International Telecommunication Union and Video Quality Experts Group. Unlike conventional 2D displays, there are several types of 3D display monitors: passive glasses, active glasses and auto-stereoscopic. In this paper, we performed subjective video quality tests using various 3D display monitors, in order to examine whether these display monitors can produce consistent perceptual video quality scores for processed video sequences. The experimental results show that the subjective scores of those 3D monitors are highly correlated and it appears that similar subjective scores will be obtained even when different types of 3D displays are used.

Applicability Evaluation of Quantitative Light-Induced Fluorescence-Digital and Cariview in Cries Prediction Study (Quantitative Light-Induced Fluorescence-Digital과 Cariview의 우식예측 연구에 대한 활용도 평가)

  • Lee, Su-Young;Lim, Soon-Ryun;Bae, Hyun-Sook
    • Journal of dental hygiene science
    • /
    • v.13 no.4
    • /
    • pp.403-409
    • /
    • 2013
  • The purpose of this study was to evaluate the correlation between caries experience, Quantitative Light-Induced Fluorescence-Digital (QLF-D) redings and new caries activity test (Cariview) results in preschool children. Fifty-seven healthy kindergarten children (male 28, female 29) were participated this study. The calibrated dentist investigated the caries experience of children and new caries activity test. Cariview samples were incubated in the activated medium at $37^{\circ}C$ for 48 hours. All QLF-D taking and readings were performed by one experienced and trained operator under identical conditions in a dental unit chair located in a darkened room. Analysis range was limited to the maxillary and mandibular anterior teeth. QLF-D redings (white spot and dental plaque) were analysed using QLF system. The dft index had a relatively high correlation with the QLF-D redings (white spot: r=0.617, simple plaque score: r=0.500) (p<0.01). Also, there was significant correlation between dft index and the Cariview score (r=0.286) (p<0.05). However, the Cariview score had no significant correlation between dt index and ft index (p>0.05). QLF-D can be evaluated objectively the initial caries lesions and dental plaque correlated with caries experience. Therefore, QLF-D will be useful to the study of caries prediction.

Comparison of clinical techniques to assess objectively accommodative response (타각적 조절 반응 평가의 임상 기술들의 비교)

  • Ryu, Dong-Kyu
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.11b
    • /
    • pp.599-602
    • /
    • 2010
  • 조절반응의 평가는 옵토메트리 검사의 중요한 일부분이다. 본 연구는 조절반응의 타각적인 검사방법인 자동굴절계와 MEM 검영법 및 Nott 동적검영법으로 측정한 검사결과의 상관성과 차이를 비교하고자 하였다. 본 연구의 취지에 동의하는 19~29사이(평균나이 22.22${\pm}$2.43세)의 정상시력을 가진 27명의 대학생을 선정하여 4D(25cm)의 조절자극이 주어진 상태에서 자동굴절계(Shin-Nippon NVision-K 5001)와 MEM 검영법 및 Nott 동적검영법을 실시하여 조절 반응을 측정하였다. 4D의 조절자극에 대한 조절반응은 자동굴절계(Shin-Nippon NVision-K 5001) 3.70${\pm}$0.25D, MEM 검영법 3.58${\pm}$0.30D 그리고 Nott 동적검영법 3.77${\pm}$0.29D로 각각 측정되었다. 3가지 검사는 상호간에 높은 상관성이 있었다(p<0.05). MEM 검영법은 Nott 동적검영법보다 0.19${\pm}$0.13D 더 낮게 측정되었고(p<0.05), 자동굴절계(Shin-Nippon NVision-K 5001) 보다 0.12${\pm}$0.24D 더 낮게 측정되었다(p<0.05). Nott 동적검영법과 자동굴절계(Shin-Nippon NVision-K 5001)로 측정한 값은 유의한 차이가 없었다(p>0.05). MEM 검영법으로 측정한 조절반응은 Nott 동적검영법이나 자동굴절계로 측정한 값보다 더 낮았다. 저자는 조절반응을 평가할 때, MEM 검영법을 제외한 Nott 동적검영법과 자동굴절계(Shin-Nippon NVision-K 5001)는 상호 대체하여 사용할 수 있다고 주장한다.

  • PDF

Correlation between Craniovertebral Angle and Body Mass Index in Middle Age for Improvement of Life Care (라이프케어 증진을 위한 중년층에서 두개척추각과 신체지수의 상관관계)

  • Moon, Ok-Kon;Choi, Tae-Seok;Choi, Wan-Seok
    • Journal of Korea Entertainment Industry Association
    • /
    • v.14 no.8
    • /
    • pp.231-236
    • /
    • 2020
  • The purpose of this study was to investigate the correlation between craniovertebral angle(CVA), age, and body mass index(BMI) in middle-aged people in their 40s and 50s. The forward head posture(FHP) was measured using a posture measuring device using a 3D sensor for 456 healthy men and women. As a result of the study, the middle-aged CVA had a high level of negative correlation with age (r=-.937; p<.01) and a very low level of positive correlation with BMI (r=.071). CVA of middle-aged men had a high negative correlation with age (r=-.932; p<.01) and a very low positive correlation with BMI. There was a correlation (r=.056), whereas, for middle-aged women, there was a high level of negative correlation (r=.939, p<.01) only with age, but had a weak (low level of negative) correlation with BMI. This study suggests that CVA has a significant negative correlation with age in both males and females however, has a weak relationship with BMI.

The Relationship of Brand Awareness and User Experience in 3D GUI Mobile Phone (3D GUI 모바일폰의 사용자 경험과 브랜드 인지도의 상관관계)

  • Kim, Seung-In;Shin, Gwi-Ja
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.1
    • /
    • pp.147-159
    • /
    • 2010
  • The touch screen phone launched domestically in Korea, unlike the existing plane UI, it applied a cubic shape of 3D UI which provides three dimensional solid graphic. This study proposes to examine the correlation between the users' experience of 3D GUI, which were made by two different companies, and the brand. From this point of view, this study sets up a hypothesis about intimate correlation between individual differentiated brand and the user experience. Base on that, a model was designed. This study measured the satisfaction of user experience through the disclosure and non-disclosure of brand, focusing on 3D GUI cases which were launched so far, and it demonstrated that there was a clear difference in the degree of satisfaction. Through this examine, a brand was confirmed as one of the important element of user experience in using the 3D GUI that was launched competitively by companies. Therefore, the result of this study suggest that the designers need to establish strategies that make the brand as the core subject of design during the process of manufacturing product and service.

Macroscopic Biclustering of Gene Expression Data (유전자 발현 데이터에 적용한 거시적인 바이클러스터링 기법)

  • Ahn, Jae-Gyoon;Yoon, Young-Mi;Park, Sang-Hyun
    • The KIPS Transactions:PartD
    • /
    • v.16D no.3
    • /
    • pp.327-338
    • /
    • 2009
  • A microarray dataset is 2-dimensional dataset with a set of genes and a set of conditions. A bicluster is a subset of genes that show similar behavior within a subset of conditions. Genes that show similar behavior can be considered to have same cellular functions. Thus, biclustering algorithm is a useful tool to uncover groups of genes involved in the same cellular process and groups of conditions which take place in this process. We are proposing a polynomial time algorithm to identify functionally highly correlated biclusters. Our algorithm identifies 1) the gene set that has hidden patterns even if the level of noise is high, 2) the multiple, possibly overlapped, and diverse gene sets, 3) gene sets whose functional association is strongly high, and 4) deterministic biclustering results. We validated the level of functional association of our method, and compared with current methods using GO.

A PAPR Reduction Method Using the Correlation of the OFDM Information Signal (정보의 상관도를 이용한 OFDM신호의 PAPR저감 기법)

  • Kim Sang-Woo;Hieu Nguyen Thanh;Ryu Heung-Gyoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.3 s.94
    • /
    • pp.327-334
    • /
    • 2005
  • In this paper, a new PAPR reduction method using correlation of input data sequence is proposed in order to overcome the serious drawbacks, such as necessity of side information transmission or increase of system complexity and calculation which are the basis of previous SLM, PTS and DSI method. A new PAPR reduction method can be classified into Method 1 and Method 2. Method 1 reduces the correlation between the smallest sub-sequence and neighbor smallest sub-sequence. And, to consider the own correlation in detail, the Method 2 reduces two case of correlation between neighbor smallest sub-sequences and neighbor largest sub-sequences. According to simulation result, Method 1 and Method 2 has about 0.5 $\~$ O.8 dB and 1 $\~$ l.2 dB PAPR reduction effect respectively. If more detailed process to reduce the correlation of input data sequence is considered, we can achieve better PAPR reduction performance.

Convective Heat Transfer Correlations for the Compact Heat Exchanger with Circular Tubes and Flat Tubes-Plate Fins (원형관 및 납작관-평판휜 형상의 밀집형 열교환기에 대한 대류열전달 상관관계식)

  • Moh, Jeong-Hah
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.3
    • /
    • pp.291-299
    • /
    • 2010
  • Aspect-ratio-based numerical analysis is carried out to investigate the air-side convective heat transfer characteristics in compact heat exchangers with circular tubes and flat tubes-plate fins. The RNG $k-{\varepsilon}$ model is adopted for turbulence analysis. The numerical analysis is carried out for aspect ratios ranging from 3.06 to 5.44 and for Reynolds numbers ranging from 1,000 to 10,000. The calculated results indicate a correlation between the friction factor and Colburn j factor in the compact heat exchanger system for the range of aspect ratios under consideration. The results obtained for circular tubes and flat tubes-plate fins in this study can be utilized to realize the optimal design of an air conditioning system.

Study of 25-Hydroxyvitamin D3 concentration according to the Hepatitis B virus (Hepatitis B virus에 따른 25-Hydroxyvitamin D3 농도 영향 연구)

  • Kim, Jean-Soo;Lee, Dong-Yeop
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.6
    • /
    • pp.2743-2748
    • /
    • 2013
  • The vitamin gets through food and the sun. But there is case that density alters by certain factor in vitamin. So this research analyzed effect of the liver function factor and change of $25OH-VIT.D_3$ density. Research target is a person who undergo health medical examination in the certain university hospital medical examination center from August, 2012 to December, 2012. Comparison classified to experiment group and control group. As a result, variable that influence in $25OH-VIT.D_3$ density showed by age and B type inflammation of the liver titer. Specially, B type inflammation of the liver titer displayed reverse corelation ($R^2$=0.40). Therefore, inflammation of the liver carrier must manage liver fuction test and density of $25OH-VIT.D_3$.

Self-Reported Symptoms and Stereopsis in Viewing 2D and 3D Images (2D와 3D입체 영상 시청에서 나타난 자각 증상과 입체시)

  • Lee, Wook-Jin;Son, Jeong-Sik;Kwak, Ho-Won;Kim, In-Su;Yu, Dong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.83-90
    • /
    • 2011
  • Purpose: This study aimed to compare and assess whether there was a relation between self-reported symptom and stereopsis in viewing an anaglyph 3D and a general 2D image. Methods: Seventy subjects (38 males, 32 females) were students ranging in age from 20 to 30 years. Subjects' symptoms were investigated by a questionnaire after viewing the 2D image and the anaglyph 3D image using red-green glasses for 30 minutes. Titmus circles and TNO stereopsis tests were performed before and after the images. A correlation between symptom and stereopsis was evaluated. Results: Both ocular and nonocular symptom in viewing 3D image were higher than those in 2D image. Titmus circles stereopsises using polarized filters were not changed before and after viewing images, but TNO stereopsises using color filters such as red-green glasses were increased after viewing 3D image. Ocular symptom and TNO stereopsis were increased after viewing 3D image, and there was a good correlation between them (r=0.605). Conclusions: Better stereopsises before viewing 3D are relatively lower ocular symptoms in viewing 3D image. But symptoms are increased in viewing anaglyph 3D image for a short-time and improvement of TNO steropsis is poorly associated with the relief of ocular symptoms. This tendency seems to be related with an adaptation to anaglyph 3D image with red-green glasses.