• 제목/요약/키워드: 308SS

검색결과 11건 처리시간 0.024초

고온설비의 FFS평가를 위한 308 스테인리스강의 크리프 균열성장 재료물성에 대한 연구 (A Study on Creep Crack Growth Properties of 308 SS for FFS Evaluation of High Temperature Components)

  • 이경용;백운봉;윤기봉
    • 한국안전학회지
    • /
    • 제17권4호
    • /
    • pp.5-10
    • /
    • 2002
  • For fitness-for-service evaluation of high temperature plant components with defects, crack growth life must be assessed properly as indicated in the recent draft of API 579 code. Type 308 stainless steel has been widely used as a field weld material in the petrochemical industry. In this study, creep crack data of type 308 stainless steel are collected and re-analyzed using $C_t$ as a characterizing fracture parameter. A unique da/dt versus $C_t$ relationship was obtained despite of difference of creep deformation constant of the reviewed materials and specimen geometry of the tested specimens. The obtained results can be employed for crack growth life assessment and fitness-for-service evaluation for the cracks in high temperature components. It is also argued that since the effect of creep properties and other material variability on the creep crack growth behavior would be minor the obtained model may be applied for most of the 308 stainless steels.

Relationships of the Vitamin D and Platelet Indices in Sjögren's Syndrome

  • Gunay, Nahide Ekici;Bugday, Irfan;Akalin, Tayfun
    • 대한임상검사과학회지
    • /
    • 제50권4호
    • /
    • pp.484-491
    • /
    • 2018
  • Primer $Sj{\ddot{o}}gren's$ Syndrome (pSS) is an autoimmune/inflammatory illness. The platelet indices (PIs) indicate the inflammatory response and activity/severity of many diseases. A vitamin D deficiency is accompanied by the increased tendency of autoimmune diseases. This study investigated whether the vitamin D levels are related to the altered platelet indices in pSS. A total of 261 individuals were included in this analytical cross-sectional study. The laboratory data of pSS patients were evaluated and the relationship between the PIs and vitamin D status was examined. According to these findings, in patients with pSS, the vitamin D levels were lower than the healthy control group (P<0.05). The vitamin D levels were negatively associated with PDW (P=0.012), but positively correlated with PCT (P<0.001). The cut-off point was obtained with receiver operating characteristics (ROC) curves for PDW: 12.53 (AUC 0.921, sensitivity 90%, specificity 85%), for PCT; 0.29 (AUC 0.660, sensitivity 68%, specificity 55%). In multivariate linear regression analysis, the most significant parameters for the effects of PDW are the following: vitamin D (${\beta}=-0.373$; t=-2.626; sig.=0.013) and plateletcrit (${\beta}=-0.308$; t=-2.13; sig.=0.040). A vitamin D deficiency may be accompanied by changes in PIs in pSS. A higher PDW and lower PCT supports the underlying inflammation, which may be vitamin D related useful parameters to consider in approaching to pSS.

Effects of feather processing methods on quantity of extracted corticosterone in broiler chickens

  • Ataallahi, Mohammad;Nejad, Jalil Ghassemi;Song, Jun-Ik;Kim, Jin-Soo;Park, Kyu-Hyun
    • Journal of Animal Science and Technology
    • /
    • 제62권6호
    • /
    • pp.884-892
    • /
    • 2020
  • Corticosterone is known as a biological stress index in many species including birds. Feather corticosterone concentration (FCC) has increasingly been used as a measure for chronic stress status in broiler chickens. As sample preparation is the first step of analytical process, different techniques of feather matrix disruption need to be validated for obtaining better result in analysing corticosterone extraction. The current study was a validation of pulverizing the feather by bead beater (BB) and surgical scissors (SS) processing prior to corticosterone extraction in feather of broiler chickens. The type of feather processing prior to the hormone extraction may alter the final output. Thereby, finding a standard method according to laboratory facilities is pivotal. This study carried out to determine the effects of feather pulverization methods on the extraction amount of corticosterone in broiler chickens. Feathers were sampled from four weeks old Ross 308 broiler chickens (n = 12 birds). All broiler chickens were kept under the same environmental condition and had access to feed and water. Feather samples were assigned to one of the following processing methods 1) using a BB for pulverizing and 2) using a SS for chopping into tiny pieces. Each sample was duplicated into two wells during enzyme immunoassay (EIA) analysis to improve the accuracy of the obtained data. The results showed lower standard errors and constant output of FCC by using the BB method compared with the SS method. Overall comparison of FCC showed a significantly higher (p < 0.001) amount of the FCC in the BB compared with the SS. Overall, using the BB method is recommended over the SS method for feather processing due to the ability to homogenize a large number of samples simultaneously, ease of use and greater extraction of feather corticosterone.

역세척 Hydrodynamic Separator Filter를 이용한 미세입자 제거 특성 분석 (Performance Evaluation of Backwash Hydrodynamic Separator Filter for Treatment of Micro Particles)

  • 이준호;방기웅
    • 대한환경공학회지
    • /
    • 제34권10호
    • /
    • pp.694-701
    • /
    • 2012
  • 본 연구는 여재를 장착한 수리동역학적 여과분리장치(HSF)와 태양전지 구동형 수중펌프를 조합한 장치의 여재 역세척 가능성에 대하여 분석하였다. 수중펌프는 12볼트 직류모터로 구동되며 태양전지와 축전지로 가동된다. 수리동력학적 분리장치와 펄라이트 여재를 충진한 카트리지에 역세척용 노즐을 장착하였다. 입자물질들은 인공입자들을 이용하여 강우유출수내 입자농도를 모의 실험하였다. 인공입자들을 물에 분산시켜 강우유출수를 재현하였는데 사용한 입자들은 이온교환수지 입자, 실리카젤 입자, 그리고 상업지역 맨홀퇴적물질 입자 등이다. HSF장치는 아크릴 수지를 이용하였는데 여과조의 직경은 250 mm이고 전체적인 높이는 800 mm로 제작하였다. 유입수 SS 농도와 입경, 다양한 수면적 변화를 변화에 대한 역세척 방법별 SS 처리효율을 산정하였다. 전체적인 수면적부하율 범위는 308~$1,250m^3/m^2/day$이다. 태양전지를 이용한 최소한의 전력으로 구동되는 펌프를 이용하여 역세척을 실시한 결과 2대의 수중 펌프를 가동하여 역세척 시 역세척하지 않은 여재와 비교하여 약 18% 처리효율 증가효과를 나타내었다. 비점오염 처리장치에 소규모 태양전지를 활용하여 여재를 역세척할 경우 처리효율을 향상시킬 수 있을 것으로 판단된다.

Experimental investigation of inelastic buckling of built-up steel columns

  • Hawileh, Rami A.;Abed, Farid;Abu-Obeidah, Adi S.;Abdalla, Jamal A.
    • Steel and Composite Structures
    • /
    • 제13권3호
    • /
    • pp.295-308
    • /
    • 2012
  • This paper experimentally investigated the buckling capacity of built-up steel columns mainly, Cruciform Columns (CC) and Side-to-Side (SS) columns fabricated from two Universal Beam (UB) sections. A series of nine experimental tests comprised of three UB sections, three CC sections and three SS sections with different lengths were tested to failure to measure the ultimate axial capacity of each column section. The lengths used for each category of columns were 1.8, 2.0, and 2.2 m with slenderness ratios ranging from 39-105. The measured buckling loads of the tested specimens were compared with the predicted ultimate axial capacity using Eurocode 3, AISC LRFD, and BS 5959-1. It was observed that the failure modes of the specimens included flexural buckling, local buckling and flexural-torsional buckling. The results showed that the ultimate axial capacity of the tested cruciform and side-by-side columns were higher than the code predicted design values by up to 20%, with AISC LRFD design values being the least conservative and the Eurocode 3 design values being the most conservative. This study has concluded that cruciform column and side-to-side welded flange columns using universal beam sections are efficient built-up sections that have larger ultimate axial load capacity, larger stiffness with saving in the weight of steel used compared to its equivalent universal beam counterpart.

A급 CMOS 전류 콘베이어 (CCII) (Class A CMOS current conveyors)

  • 차형우
    • 전자공학회논문지C
    • /
    • 제34C권9호
    • /
    • pp.1-9
    • /
    • 1997
  • Novel class A CMOS second-generation current conveyors (CCII) using 0.6.mu.m n-well standard CMOS process for high-frequency current-mode signal processing were developed. The CCII consists of a regulated current-cell for the voltage input and a cascode current mirror for the current output. In this architecture, the two input stages are coupled by current mirrors to reduce the current input impedance. Measurements of the fabricated cCII show that the current input impedance is 308 .ohm. and the 3-dB cutoff frequency when used as a voltage amplifier extends beyond 10MHz. The linear dynamic ranges of voltage and current are from -0.5V to 1.5V and from -100.mu.A to +120.mu.A for supply voltage V$\_$DD/ = -V$\_$SS/=2.5V, respectively. The power dissipation is 2 mW and the active chip area is 0.2 * 0.2 [mm$\^$2/].

  • PDF

Evaluation of the performance of encapsulated lifting system composting technology with a GORE(R) cover membrane: Physico-chemical properties and spectroscopic analysis

  • Al-Alawi, Mutaz;El Fels, Loubna;Benjreid, Ramadan;Szegi, Tamas;Hafidi, Mohamed;Simon, Barbara;Gulyas, Miklos
    • Environmental Engineering Research
    • /
    • 제25권3호
    • /
    • pp.299-308
    • /
    • 2020
  • Composting is among the most effective integrated waste management strategies used to recycle sewage sludge (SS) waste and generate a useful product. An encapsulated lifting system is a relatively new industrial-scale composting technology. The objective of this study was to evaluate the effectiveness of composting dewatered stabilized SS mixed with green waste using this new technology. The composting process was monitored by changes in the physico-chemical properties, UV-visible spectra, and fourier transform infrared (FTIR) spectra. The composting temperature was steady in the thermophilic range for 24 and 12 d in the intensive and maturation phases, respectively, which fulfilled the disinfection requirement. Moreover, the temperature increased rapidly to 76.8℃ within three days, and the thermophilic temperatures peaked twice and lasted longer than in traditional composting, which accelerated SS degradation and decreased the composting period necessary to obtain mature compost. FTIR spectroscopic analysis showed a diminished in methyl group derived from methylene C-H aliphatic groups because of organic matter degradation by microorganisms and an increased number of aromatic chains. The new technology may be a viable and sustainable alternative for SS management that converts waste into compost that is useful as a soil amendment.

면섬유염색폐수의 공정별 폐수성상과 이온화가스에 의한 처리특성 (Composition of Cotton Textile Dyeing Process Wastewater and its Treatment Characteristics by Ionized Gas)

  • 임경은;정팔진;권지영;이은주
    • 한국물환경학회지
    • /
    • 제23권3호
    • /
    • pp.303-308
    • /
    • 2007
  • Three types dyeing wastewater (dark, medium, light color) discharged from cotton textile dyeing with reactive dye was collected at each step of process. Each process dying wastewater was analyzed and treated by ionized gas. The analysis focused on $COD_{Cr}$, SS and color. Bleaching & scouring process wastewater has the highest $COD_{Cr}$ value in the three type dyeing wastewater. SS shows the highest value at dyeing process wastewater in dark and medium color but light color has at finishing process wastewater. The result of process wastewater treatment by ionized gas was that the ionized gas was effective in $COD_{Cr}$ removing of bleaching & scouring process and finishing process wastewater but was not good at dyeing process wastewater. From that result it is estimated that the ionized gas could not work in opening the aromatic ring and react only in aliphatic component of the molecule. Because the surfactants contained in bleaching & scouring process and finishing process wastewater have only one aromatic ring in its molecular structure, in contrast with the reactive dye compounds consist of aromatic rings great part of its molecular structure. The color almost removed in 1.5 hrs reaction time but $COD_{Cr}$ removal effiency was only 30.7% through 3hrs in 1500 mL of total dyeing wastewater treated by 10 L/min ionized gas.

농촌 소유역에서의 비점오염물질 유출 특성 - 충남 공주시 정안면 고성리 지역을 대상으로 - (Characteristics of Non-Point Pollutants Discharge in a Small Rural Watershed)

  • 김진호;한국헌;류종수;임혁진;이경도;권순국
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2005년도 학술발표논문집
    • /
    • pp.552-556
    • /
    • 2005
  • This study was conducted to identify the characteristics of non-point pollutants discharge in a small Rural watershed. For this purpose, the typical rural area in Gongju city was selected as a research site. Water quality and water quantity data in the stream and the precipitation of the watershed were analyzed periodically from May 1 to August 31 in 2005. Also, pollutant loads were estimated using these data. As a result, the mean concentrations of BOD, TN and TP in the stream were 3.16, 3.20, 0.236 mg/L rainy season and 0.93, 2.75, 0.058 mg/L in normal survey season respectively. The estimation of non-point pollutants discharge loads were shown that BOD was 5,154.2kg, T-N was 9,164.7kg, T-P was 308.4kg, and SS was 117,163.2kg from July to August. That means above of 90% of non-point pollutants discharge was occurred in rainy season.