• Title/Summary/Keyword: 3.5 GHz band

Search Result 838, Processing Time 0.031 seconds

Microwave Cavity with Controllable Temperature for In Vitro Hyperthermia Investigations

  • Kiourti, Asimina;Sun, Mingrui;He, Xiaoming;Volakis, John L.
    • Journal of electromagnetic engineering and science
    • /
    • v.14 no.3
    • /
    • pp.267-272
    • /
    • 2014
  • Hyperthermia is a form of cancer treatment in which affected human tissue is exposed to $>40^{\circ}C$ temperature. In this paper, our goal is to assess the efficacy of fullerene agents to reduce heating time for cancer treatment. Such agents can accelerate heating of cancer cells and improve hyperthermia treatment efficacy. Typically, in vitro testing involves cancer cell culturing, heating cell cultures in accordance to specifications, and recording cancer cell viability after hyperthermia. To heat cell cultures, we design and evaluate a 2.4-GHz microwave cavity with controllable temperature. The cavity is comprised of a polystyrene cell culture dish (diameter = 54 mm, height = 13.5 mm) and a printed monopole antenna placed within the cavity for microwave heating. The culture temperature can be controlled through the intensity and duration of the antenna's microwave radiation. Heating experiments were carried out to validate the cavity's performance for F-12K culture medium (Kaighn's F-12K medium, ATCC). Importantly, fullerene agents were shown to reduce heating time and improve hyperthermia treatment efficacy. The culture medium temperature increased, on average, from $24.0^{\circ}C$ to $50.9^{\circ}C$ (without fullerene) and from $24.0^{\circ}C$ to $56.8^{\circ}C$ (with 3 mg/mL fullerene) within 15 minutes.

Implementation of Digital Frequency Synthesizer for High Speed Frequency Hopping (DDS를 이용한 고속 주파수 Hopping용 디지털 주파수 합성기 구현)

  • Kim Young-Wan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.607-610
    • /
    • 2006
  • The Digital Frequency Synthesizer(DFS) that generates the wideband signal with hish speed frequency hopping rate and high frequency resolution characteristics was implemented in this paper. The DFS was applied as local oscillator for direct frequency conversion IF modules of DVB-RCS, which directly generates the transmission immediate frequency signal by using DDS and wideband PLL technologies. The DDS technology provides high speed frequency hopping rate and high frequency resolution characteristics, which ate also the DVB-RCS requirement. The wideband PLL technology also provides the wideband signal generation, which is a necessity for direct frequency conversion modules. The implemented DFS provide the spurious suppression characteristic of -50 dBc, frequency resolution of 0.233 Hz and frequency hopping rate of 125 ns, respectively. Also the DFS represent the amplitude flatness of 3 dB and less in the pass-band and phase noise characteristic of -75 dBc/Hz at 1 kHz frequency offset.

  • PDF

Design and Implementation of Wideband Digital Frequency Synthesizer for DVB-RCS (DVB-RCS 전송을 위한 광대역 디지털 주파수 합성기 설계 및 구현)

  • Kim, Young-Wan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.2
    • /
    • pp.223-228
    • /
    • 2007
  • The Digital Frequency Synthesizer(DFS) that generates the wideband signal with high speed frequency hopping rate and high frequency resolution characteristics was designed and implemented in this paper The DFS was applied as local oscillator for direct frequency conversion IF modules of DVB-RCS, which directly generates the transmission immediate frequency signal by using DDS and wideband PLL technologies. The DDS technology provides high speed frequency hopping rate and high frequency resolution characteristics, which are also the DVB-RCS requirement. The wideband PLL technology also provides the wideband signal generation, which is a necessity for direct frequency conversion modules. The implemented DFS provides the spurious suppression characteristic of -50 dBc and less, frequency resolution of 0.233 Hz and frequency hopping rate of 125 ns, respectively. Also the DFS represents the amplitude flatness of 3 dB and less in the pass-band, and phase noise characteristic of -75 dBc/Hz at 1 kHz frequency offset.

Microwave Absorbing Characteristics of Ferrite-silicon carbide surface Films Produced (플라즈마 용사방식에 의해 형성된 페라이트-탄화규소 표면층의 마이크로파 흡수 특성(II))

  • Shin, Dong-Chan;Son, Hyon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.18 no.8
    • /
    • pp.1169-1175
    • /
    • 1993
  • Plasma spraying method was used to fabricated the microwave absorbing ferrite-silicon carbide on the aluminum-alloy of the fuselage of an aircraft to protect it from RADAR detection. In this paper 15[rm] instead of 34[rm], the mean size of SIC-powder for ferrite-silicon carbide surface films(I) was used. 50(Kg/h) Instead of 70(Kg/h), the powder feed and 100[mm] Instead of 80(mm), spray distance of spray parameters was used. This M/W absorbers were designed experimentally and fabricated trially, as a result of which the relative frequency bandwidth of 2.8% were obtained under the tolerance limits of the reflection coefficients lower than-10[dB], and the maximum absorption thickness becomes 0.5[mm], which is much thinner than that of the conventional ones.

  • PDF

Quality Enhancement of Wave Data Observed by Radar at the Socheongcho Ocean Research Station (소청초 종합해양과학기지 Radar 파랑 관측 데이터의 신뢰도 향상)

  • Min, Yongchim;Jeong, JinYong;Shim, Jae-Seol;Do, Kideok
    • Journal of Coastal Disaster Prevention
    • /
    • v.4 no.4
    • /
    • pp.189-196
    • /
    • 2017
  • Ocean Research Stations (ORSs) is the ocean platform type observation towers and measured oceanic, atmospheric and environmental data. These station located on the offshore area far from the coast, so they can produce the data without land effect. This study focused to improve the wave data quality of ORS station. The wave observations at ORSs are used by the C-band (5.8 GHz, 5.17 cm) MIROS Wave and Current Radar (MWR). MWR is convenient to maintenance and produce reliability wave data under bad weather conditions. MWR measured significant wave height, peak wave period, peak wave direction and 2D wave spectrum, so it's can provide wave information for researchers and engineers. In order to improve the reliability of MWR wave data, Datawell Waverider Buoy was installed near the one ORS (Socheoncho station) during 7 months and validate the wave data of MWR. This study found that the wave radar tend to be overestimate the low wave height under wind condition. Firstly, this study carried out the wave Quality Control (QC) using wind data, however the quality of wave data was limited. So, this study applied the four filters (Correlation Check, Direction Filter, Reduce White Noise and Phillips Check) of MWR operating software and find that the filters effectively improve the wave data quality. After applying 3 effective filters in combination, the RMSE of significant wave height decreased from 0.81m to 0.23m, by 0.58m and Correlation increased from 0.66 to 0.96, by 0.32, so the reliability of MWR significant wave height was significantly improved.

Effect of Plasma Area on Frequency of Monostatic Radar Cross Section Reduction

  • Ha, Jungje;Shin, Woongjae;Lee, Joo Hwan;Kim, Yuna;Kim, Doosoo;Lee, Yongshik;Yook, Jong-Gwan
    • Journal of electromagnetic engineering and science
    • /
    • v.17 no.3
    • /
    • pp.153-158
    • /
    • 2017
  • This work reports on the effect of plasma area on the frequency characteristics of the monostatic radar cross section (RCS) of a square metallic plate. A dielectric barrier discharge (DBD) plasma actuator consisting of 10 rings is proposed. The actuator is fabricated in three different configurations such that only three inner rings, seven inner rings, and all rings can be biased. By applying an 18-kV bias at 1 kHz, the three types of DBD actuators generate plasma with a total area of 16.96, 36.74, and $53.69cm^2$, respectively, in a ring or circular form. The experimental results reveal that when the DBD actuator is placed in front of a $20mm{\times}20cm$ conducting plate, the monostatic RCS is reduced by as much as 18.5 dB in the range of 9.41-11.65 GHz. Furthermore, by generating the plasma and changing the area, the frequency of maximum reduction in the monostatic RCS of the plate can be controlled. The frequency is reduced by nearly 20% in the X band when all rings are biased. Finally, an electromagnetic model of the plasma is obtained by comparing the experimental and full-wave simulated results.

Dual Bias Modulator for Envelope Tracking and Average Power Tracking Modes for CMOS Power Amplifier

  • Ham, Junghyun;Jung, Haeryun;Bae, Jongsuk;Lim, Wonseob;Hwang, Keum Cheol;Lee, Kang-Yoon;Park, Cheon-Seok;Yang, Youngoo
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.6
    • /
    • pp.802-809
    • /
    • 2014
  • This paper presents a dual-mode bias modulator (BM) for complementary metal oxide semiconductor (CMOS) power amplifiers (PAs). The BM includes a hybrid buck converter and a normal buck converter for an envelope tracking (ET) mode for high output power and for an average power tracking (APT) mode for low output power, respectively. The dual-mode BM and CMOS PA are designed using a $0.18-{\mu}m$ CMOS process for the 1.75 GHz band. For the 16-QAM LTE signal with a peak-to-average power ratio of 7.3 dB and a bandwidth of 5 MHz, the PA with the ET mode exhibited a poweradded efficiency (PAE) of 39.2%, an EVM of 4.8%, a gain of 19.0 dB, and an adjacent channel leakage power ratio of -30 dBc at an average output power of 22 dBm, while the stand-alone PA has a PAE of 8% lower at the same condition. The PA with APT mode has a PAE of 21.3%, which is an improvement of 13.4% from that of the stand-alone PA at an output power of 13 dBm.

Analytical Modeling of Conventional and Miniaturization Three-Section Branch-Line Couplers

  • You, Kok Yeow;AL-AREQI, Nadera;Chong, Jaw Chung;Lee, Kim Yee;Cheng, Ee Meng;Lee, Yeng Seng
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.858-867
    • /
    • 2018
  • Analytical modeling equations are proposed for the conventional and modified three-section branch-line couplers. The analytical equations are explicit and capable of determining the characteristic impedance of each branch line for the coupler at desired coupling level as well as the suitability of broadband S-parameters analysis. In addition, a bandwidth extension and miniaturization of three-section branch-line coupler using slow-wave and meandering line structures were designed. The modified coupler, which is able to operate within frequencies from 1.5 to 3.32 GHz has been fabricated, tested and compared. A bandwidth extension of 600 MHz and 53% reduced size of the modified coupler have been achieved compared to a conventional coupler. The modified coupler has roughly insertion loss and coupling of -4 dB and -3.2 dB, while the isolation and return loss, respectively less than -14 dB with fractional bandwidth of 77 %, as well as phase imbalances less than $2^{\circ}$ over the operating bandwidth. Overall, the derived analytical model, simulation and measurement results demonstrated a good agreement.

In Vitro and In Vivo Agreement of Microwave Radio-Thermometer and Needle Probe Thermometer During Therapeutic Ultrasound (초음파 가열 시 In Vitro 및 In Vivo에서 Microwave Radio-Thermometer와 탐침온도계의 일치도)

  • Lee, Su-Young;Cho, Sang-Hyun;Yi, Chung-Hwi;Kim, Jong-Man
    • Physical Therapy Korea
    • /
    • v.10 no.1
    • /
    • pp.15-27
    • /
    • 2003
  • Therapeutic ultrasound is commonly applied for deep heating in physical therapy setting. However, it is difficult to determine the exact application dosage and to confirm the immediate heating effect. Microwave Radio-Thermometer (MRT) can measure the temperature by the electromagnetic energy in the microwave region of the object that emits above absolute zero temperature. MRT was used for early diagnosis of breast cancer since it was not harmful, non-invasive, and non-ionizing to the human body. The purposes of this study were to investigate how accurately 1.1 GHz RTM (RES Ltd. Russia) measures the change of average temperature in the tissue, and to determine the depth of temperature change measurement. Therapeutic ultrasound was applied (continuous wave for 5 minutes, 1 MHz, intensity of 1.5 $W/cm^2$ [in vitro] and 1.0 $W/cm^2$ [in vivo]) in four different conditions: (1) 30 cases of in vitro specimen of pork, (2) 30 cases of in vitro specimen of pork ankle joint, (3) 10 cases of in vivo canine thigh, and (4) 30 cases of in vivo human body. Intraclass Correlation Coeffients (ICC[3,1]) between average needle probe thermometer below surface and MRT temperature was revealed as followed: (1) Before ultrasound application ICCs ranges above .8 in specimen of pork (15 mm underneath the skin) and above .82 in specimen of pork ankle joint (10~30 mm underneath the skin). (2) After ultrasound application ICCs ranges above .7 in both specimens of pork and pork ankle joint. (3) Before ultrasound application ICCs ranges above .8 in canine thigh (20 mm underneath the skin). (4) After ultrasound application ICCs ranges above .82 in canine thigh. The temperature of the human body increased significantly with the mean of $15^{\circ}C$ in muscle tissue and with the mean of $3.5^{\circ}C$ in joint (p<.00). It was revealed that the average depth of temperature measurement of the tissue by MRT was in between 10 and 35 mm, and determined that the proper temperature measurement band was $36.5{\sim}37.0^{\circ}C$.

  • PDF

Analysis of Adjacent-Channel Leakage-Ratio of Wide-Band Power Amplifiers through Multi-Tone Signals with Statistical Similarity (다중 톤 신호의 통계적 특성 확보를 통한 광대역 신호 증폭기의 인접 채널 간섭 분석)

  • Park, Young-Cheol
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.12
    • /
    • pp.1172-1175
    • /
    • 2011
  • In this paper, a design method of multi-tone signals for the measurement of adjacent-channel power-ratios on power amplifiers is suggested. Because most tests for power amplifiers in production are performed with single-tone signals, its testing accuracy is not guaranteed as the signal complexity increases. Therefore, the application of multi-tone signals to the testing is suggested by optimized complex coefficients of each tones for the best statistical similarity to the original modulated signal. From the verification, a 802.11a signal was replaced with a multi-tone signal of N=10, with the complex coefficients generated by the suggested method. The resulting measurements on the ACLR of 2.4 GHz power amplifier showed successful accuracy of less than 1 dB discrepancy.