• Title/Summary/Keyword: 3-phase AC-DC converter

Search Result 181, Processing Time 0.027 seconds

DC microgrid three-phase four-wire interlinking converter using negative-sequence extraction (역상분 추출을 사용한 DC마이크로그리드의 3상 4선식 방식의 인터링킹 컨버터)

  • Kim, Mi Na;Kang, Jin-Wook;Kim, Bum-Jun;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.118-120
    • /
    • 2019
  • 제안하는 논문은 3상 4선식 방식의 Interlinking Converter(ILC)를 사용하여 DC bus와 AC bus를 연계 한다. 역상분 성분은 정상분 성분과 다르게 전압 평형시 발생하지 않다가 전압 불평형시 발생하기 때문에 역상분을 추출하여 제어함으로써 불평형을 개선한다. Psim 시뮬레이션을 통해 본 논문의 타당성을 검증한다.

  • PDF

Power Factor Correction of Three Phase DCM Converter by 3-stage Operation (3-stage 운전에 의한 3상 DCM컨버터의 입력 역률개선)

  • 최해룡;구영모;김응진;목형수;최규하;김규식;원충연
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.659-662
    • /
    • 1999
  • As utility pollution take a growing interest, ac/dc converter optimizing utility condition has been vigorously studied in decades. In this paper three phase DCM converter is analyzed and equations for average input currents are presented. Also relationships of voltage gain & duty according to angular velocity are presented and variable frequency controller is implemented using reset integrator which is designed in detail. In result power factor and THD characteristics of 3-stage and 4-stage operation ae compared respectively.

  • PDF

Structure and Control of Smart Transformer with Single-Phase Three-Level H-Bridge Cascade Converter for Railway Traction System (Three-Level H-Bridge 컨버터를 이용한 철도차량용 지능형 변압기의 구조 및 제어)

  • Kim, Sungmin;Lee, Seung-Hwan;Kim, Myung-Yong
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.5
    • /
    • pp.617-628
    • /
    • 2016
  • This paper proposes the structure of a smart transformer to improve the performance of the 60Hz main power transformer for rolling stock. The proposed smart transformer is a kind of solid state transformer that consists of semiconductor switching devices and high frequency transformers. This smart transformer would have smaller size than the conventional 60Hz main transformer for rolling stock, making it possible to operate AC electrified track efficiently by power factor control. The proposed structure employs a cascade H-Bridge converter to interface with the high voltage AC single phase grid as the rectifier part. Each H-Bridge converter in the rectifier part is connected by a Dual-Active-Bridge (DAB) converter to generate an isolated low voltage DC output source of the system. Because the AC voltage in the train system is a kind of medium voltage, the number of the modules would be several tens. To control the entire smart transformer, the inner DC voltage of the modules, the AC input current, and the output DC voltage must be controlled instantaneously. In this paper, a control algorithm to operate the proposed structure is suggested and confirmed through computer simulation.

Sensorless Control of 3-phase PFC AC/DC Converter using Kalman Filter (칼만필터를 이용한 3상 PFC AC/DC 컨버터의 센서리스 제어)

  • Park, Jun-Sung;Kwon, Young-Ahn
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.5
    • /
    • pp.998-1004
    • /
    • 2016
  • This paper investigates a new sensorless control appling a virtual flux oriented vector control without the line voltage sensor for the power factor correction of 3 phase PWM converter. The DC output voltage is controlled by applying the kalman filter algorithm for the virtual flux estimation and the synchronous phase is obtained by using the estimated virtual flux equation based on kalman filter. This method is used to reduce the calculation time of the system and obtain a stable control that the input current including the harmonics and the noise is improved. The proposed system implement PFC algorithm in the variable region of DC output voltage. It can obtain the unity power factor, and can precisely control the DC output voltage in the load variation and in the variable voltage range. The performance of the proposed algorithm is verified through simulation and experiment.

Characteristics of DC 48[V] telecommunication power supply (DC 48[V] 통신용 전원 장치의 특성)

  • Jung, H.T.;Jo, M.C.;Youn, Y.T.;Kim, J.Y.;Mun, S.P.;Suh, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.902-904
    • /
    • 2005
  • The AC-DC converter, which has three-phase AC power as input and isolated DC power as output is used for the regulated DC power supply of the telecommunication power processing system for several kilowatt class applications. The conventional DC power supply for the telecommunication power system comprises a PWM rectifier with sine-wave shaping input current unity power factor and a DC/DC converter connected to the PWM converter, which obtains DC 48[V]. Since power passes through these two power stage converters, the conversion power loss is difficult to provide high efficiency. To resolve these problems, this paper presents a new PWM rectified as a 1-stage power conversion method. It simulation and experimental results as proved from a practical point of view that 92.1[%]of conversion efficiency and input current which can meet harmonics regulation of the Class-A in IEC61000-3-3 are achieved.

  • PDF

Characteristics of DC 48[V] telecommunication power supply (DC 48[V] 통신용 전원 장치의 특성)

  • Jung, H.T.;Jo, M.C.;Youn, Y.T.;Kim, J.Y.;Mun, S.P.;Suh, K.V.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07d
    • /
    • pp.3114-3116
    • /
    • 2005
  • The AC-DC converter, which has three-phase AC power as input and isolated DC power as output is used for the regulated DC power supply of the telecommunication power processing system for several kilowatt class applications. The conventional DC power supply for the telecommunication power system comprises a PWM rectifier with sine-wave shaping input current unity power factor and a DC/DC converter connected to the PWM converter, which obtains DC 48[V]. Since power passes through these two power stage converters, the conversion power loss is difficult to provide high efficiency. To resolve these problems, this paper presents a new PWM rectified as a 1-stage power conversion method. It simulation and experimental results as proved from a practical point of view that 92.1[%] of conversion efficiency and input current which can meet harmonics regulation of the Class-A in IEC61000-3-3 are achieved.

  • PDF

Characteristics of DC 48[V] telecommunication power supply (DC 48[V] 통신용 전원 장치의 특성)

  • Jung, H.T.;Jo, M.C.;Youn, Y.T.;Kim, J.Y.;Mun, S.P.;Suh, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2462-2464
    • /
    • 2005
  • The AC-DC converter, which has three-phase AC power as input and isolated DC power as output is used for the regulated DC power supply of the telecommunication power processing system for several kilowatt class applications. The conventional DC power supply for the telecommunication power system comprises a PWM rectifier with sine-wave shaping input current unity power factor and a DC/DC converter connected to the PWM converter, which obtains DC 48[V]. Since power passes through these two power stage converters, the conversion power loss is difficult to provide high efficiency. To resolve these problems, this paper presents a new PWM rectified as a 1-stage power conversion method. It simulation and experimental results as proved from a Practical point of view that 92.1[%]of conversion efficiency and input current which can meet harmonics regulation of the Class-A in IEC61000-3-3 are achieved.

  • PDF

Characteristics of DC 48[V] telecommunication power supply (DC 48[V] 통신용 전원 장치의 특성)

  • Jung, H.T.;Jo, M.C.;Youn, Y.T.;Kim, J.Y.;Mun, S.P.;Suh, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1820-1822
    • /
    • 2005
  • The AC-DC converter, which has three-phase AC power as input and isolated DC power as output is used for the regulated DC power supply of the telecommunication power processing system for several kilowatt class applications. The conventional DC power supply for the telecommunication power system comprises a PWM rectifier with sine-wave shaping input current unity power factor and a DC/DC converter connected to the PWM converter, which obtains DC 48[V]. Since power passes through these two power stage converters, the conversion power loss is difficult to provide high efficiency. To resolve these problems, this paper presents a new PWM rectified as a 1-stage power conversion method. It simulation and experimental results as proved from a practical point of view that 92.1[%]of conversion efficiency and input current which can meet harmonics regulation of the Class-A in IEC61000-3-3 are achieved.

  • PDF

The grid-connected bidirectional PCS technology of the ESS (에너지 저장장치의 계통 연계형 양방향 PCS 기술)

  • Ko, Bong-Woon
    • Journal of IKEEE
    • /
    • v.23 no.4
    • /
    • pp.1280-1287
    • /
    • 2019
  • Grid-connected bidirectional PCS(Power Conditioning System) technology is a technology for implementing distributed renewable energy smart grid. And it is always charged by using power collected from solar modules and commercial grid power among vast smart grid systems, and stored when needed.It is a hybrid energy storage device that allows power to be released into the low voltage system. To this end, a PV input power converter with MPPT function, a bidirectional power converter for battery charging and discharging, and a DC Link input are output to a 3 phase 380V AC system, and if nessary, the bidirectional DC/DC converter We designed and developed a PCS with three power converter structures composed of inverters that perform battery charging. Currently, this system is applied to the site of Jeju, which is vulnerable to power outages and fire accidents.

New Method of SVPWM Implementation Using Single Carrier Wave and Comparision of PI/PR Current Control for the Vienna Converter (비엔나 컨버터를 위한 단일 반송파를 이용한 새로운 방식의 SVPWM 구현과 PI/PR 전류제어기의 비교)

  • Cho, Nam-Su;Ji, Jun-Keun;Lee, Tae-Won;Yun, Bong-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.3
    • /
    • pp.522-532
    • /
    • 2017
  • In this paper, a new method of SVPWM implementation for 3-Phase 3-Leg 3-Level AC/DC converter known as the Vienna converter is proposed. Also the performances of PI and PR controller used in AC input current controller are compared. To verify the proposed method, PSIM, a power electronics simulation program, is utilized. The performances of the proposed new method and the two existing methods are compared through simulation and experiment. Also PI and PR controller in AC input current controller are compared through 10[kW] Vienna converter system.