• 제목/요약/키워드: 3-dimensional computer tomography

검색결과 88건 처리시간 0.018초

악교정 수술에서 모의 조종된 3차원 전산화 단층촬영상의 응용 (Application of Simulated Three Dimensional CT Image in Orthognathic Surgery)

  • 김형돈;유선국;이경상;박창서
    • 치과방사선
    • /
    • 제28권2호
    • /
    • pp.363-385
    • /
    • 1998
  • In orthodontics and orthognathic surgery. cephalogram has been routine practice in diagnosis and treatment evaluation of craniofacial deformity. But its inherent distortion of actual length and angles during projecting three dimensional object to two dimensional plane might cause errors in quantitative analysis of shape and size. Therefore, it is desirable that three dimensional object is diagnosed and evaluated three dimensionally and three dimensional CT image is best for three dimensional analysis. Development of clinic necessitates evaluation of result of treatment and comparison before and after surgery. It is desirable that patient that was diagnosed and planned by three dimensional computed tomography before surgery is evaluated by three dimensional computed tomography after surgery. too. But Because there is no standardized normal values in three dimension now and three dimensional Computed Tomography needs expensive equipments and because of its expenses and amount of exposure to radiation. limitations still remain to be solved in its application to routine practice. If postoperative three dimensional image is constructed by pre and postoperative lateral and postero-anterior cephalograms and preoperative three dimensional computed tomogram. pre and postoperative image will be compared and evaluated three dimensionally without three dimensional computed tomography after surgery and that will contribute to standardize normal values in three dimension. This study introduced new method that computer-simulated three dimensional image was constructed by preoperative three dimensional computed tomogram and pre and postoperative lateral and postero-anterior cephalograms. and for validation of new method. in four cases of dry skull that position of mandible was displaced and four patients of orthognathic surgery. computer-simulated three dimensional image and actual postoperative three dimensional image were compared. The results were as follows. 1. In four cases of dry skull that position of mandible was displaced. range of displacement between computer-simulated three dimensional images and actual postoperative three dimensional images in co-ordinates values was from -1.8 mm to 1.8 mm and 94% in displacement of all co-ordinates values was from -1.0 mm to 1.0 mm and no significant difference between computer-simulated three dimensional images and actual postoperative three dimensional images was noticed(p>0.05). 2. In four cases of orthognathic surgery patients, range of displacement between computer­simulated three dimensional images and actual postoperative three dimensional images in coordinates values was from -6.7 mm to 7.7 mm and 90% in displacement of all co-ordinates values was from -4.0 to 4.0 mm and no significant difference between computer-simulated three dimensional images and actual postoperative three dimensional images was noticed(p>0.05). Conclusively. computer-simulated three dimensional image was constructed by preoperative three dimensional computed tomogram and pre and postoperative lateral and postero-anterior cephalograms. Therefore. potentiality that can construct postoperative three dimensional image without three dimensional computed tomography after surgery was presented.

  • PDF

A STUDY ON THE DIMENSIONAL ACCURACY OF MODELS USING 3-DIMENSIONAL COMPUTER TOMOGRAPHY AND 2 RAPID PROTOTYPING METHODS

  • Cho Lee-Ra;Park Chan-Jin;Park In-Woo
    • 대한치과보철학회지
    • /
    • 제39권6호
    • /
    • pp.633-640
    • /
    • 2001
  • Statement of problem. Relatively low success rate of root analogue implant system was supposed to be due to the time duration between extraction and implant installation. The use of three-dimensional computer tomography and the reconstruction of objects using rapid prototyping methods would be helpful to shorten this time. Purpose. This aim of this study was to evaluate the application possibility of the 3-dimensional computer tomography and the rapid prototyping to root analogue implants. Material and methods. Ten single rooted teeth were prepared. Width and height of the teeth were measured by the marking points. This was followed by CT scanning, data conversion and rapid prototyping model fabrication. 2 methods were used; fused deposition modelling and stereolithography. Same width and height of this models were measured and compared to the original tooth. Results. Fused deposition modelling showed an enlarged width and reduced height. The stereolithography showed more exact data compared with the fused deposition modelling. Smaller standard deviation were recorded in the stereolithographic method. Overall width error from tooth to rapid prototyping was 7.15% in fused deposition modelling and 0.2% in stereolithography. Overall height showed the tendency of reducing dimensions. Conclusion. From the results of this study, stereolithography seems to be very predictable method of fabricating root analogue implant.

  • PDF

충돌 제트 분석을 위한 3차원 토모그래피 기법 개발 (Development of Three-dimensional Tomography Technique for Analysis of Impinging Jet)

  • 김용재;안성수;고한서
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2004년도 추계학술대회 논문집
    • /
    • pp.34-35
    • /
    • 2004
  • Three dimensional density distributions of impinging and eccentric flames have been investigated by digital speckle tomography. The flames have been ignited by a mixture of butane and air from a circular nozzle and impinged against a plate located at the upper side of the burner exit. For comparison with experimental data, computer synthesized phantoms of impinging and eccentric flames have been reconstructed by a developed three-dimensional multiplicative algebraic reconstruction technique (MART). The advanced reconstruction in the stagnation flow region involved the sharp change of the flow direction and pressure gradient has been developed using a cross-correlation method and new scanning technique for the speckle displacement.

  • PDF

Common-path Optical Coherence Tomography for Biomedical Imaging and Sensing

  • Kang, Jin-U.;Han, Jae-Ho;Liu, Xuan;Zhang, Kang
    • Journal of the Optical Society of Korea
    • /
    • 제14권1호
    • /
    • pp.1-13
    • /
    • 2010
  • This paper describes a development of a fiber optic common-path optical coherence tomography (OCT) based imaging and guided system that possess ability to reliably identify optically transparent targets that are on the micron scale; ability to maintain a precise and safe position from the target; ability to provide spectroscopic imaging; ability to imaging biological target in 3-D. The system is based on a high resolution fiber optic Common-Path OCT (CP-OCT) that can be integrated into various mini-probes and tools. The system is capable of obtaining >70K A-scan per second with a resolution better than $3\;{\mu}m$. We have demonstrated that the system is capable of one-dimensional real-time depth tracking, tool motion limiting and motion compensation, oxygen-saturation level imaging, and high resolution 3-D images for various biomedical applications.

2상유동장 내 3차원 밀도 분포 재건을 위한 토모그래피 기법의 성능 비교 분석 (Comparison and Analysis of Tomography Methods for Reconstruction of Three-dimensional Density Distributions in Two-phase Flows)

  • 고한서;김용재
    • 비파괴검사학회지
    • /
    • 제22권5호
    • /
    • pp.545-556
    • /
    • 2002
  • Algebraic reconstruction technique (ART)과 multiplicative algebraic reconstruction technique (MART)이라는 토모그래피 방법을 이용하여 2상유동에서 기포의 거동을 배침투적으로 분석하였다. 먼저, 컴퓨터 합성 영상장으로 환상유통과 기포유동을 제작하여 2차원 단면의 재건을 시도하였다. 2상유동의 보다 정확한 결과들을 얻기 위하여 두가지 토모그래피 방법이 비교되었다. 그리고, 2상유동에서 기포의 거동을 3차원으로 분석하기 위하여 2개와 3개의 기포가 존재하는 3차원 합성 영상장으로부터 2차원 단면에서 보다 정확한 결과를 보인 MART 재건법에 의해서 밀도 분포 해석을 수행하였다.

Use of the surface-based registration function of computer-aided design/computer-aided manufacturing software in medical simulation software for three-dimensional simulation of orthognathic surgery

  • Kang, Sang-Hoon;Lee, Jae-Won;Kim, Moon-Key
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제39권4호
    • /
    • pp.197-199
    • /
    • 2013
  • Three-dimensional (3D) computed tomography image models are helpful in reproducing the maxillofacial area; however, they do not necessarily provide an accurate representation of dental occlusion and the state of the teeth. Recent efforts have focused on improvement of dental imaging by replacement of computed tomography with other detailed digital images. Unfortunately, despite the advantages of medical simulation software in dentofacial analysis, diagnosis, and surgical simulation, it lacks adequate registration tools. Following up on our previous report on orthognathic simulation surgery using computer-aided design/computer-aided manufacturing (CAD/CAM) software, we recently used the registration functions of a CAD/CAM platform in conjunction with surgical simulation software. Therefore, we would like to introduce a new technique, which involves use of the registration functions of CAD/CAM software followed by transfer of the images into medical simulation software. This technique may be applicable when using various registration function tools from different software platforms.

악안면 3차원 계측시 컴퓨터 단층촬영과 두부 방사선 규격사진의 정확성 비교 분석 (Comparative Analysis of Accuracy between Computerized Tomography and Cephalogram for 3-Dimensional Measurement of Maxillofacial Structure)

  • 백종수;송재철;이희경
    • Journal of Yeungnam Medical Science
    • /
    • 제18권1호
    • /
    • pp.123-137
    • /
    • 2001
  • 6개의 건조두개골상의 중요한 방사선학적 계측점에 금속구를 위치시킨 후 3-D CT와 정모 및 측모 두부 방사선사진을 촬영하고 이를 바탕으로 만든 각각의 3차원 영상과 3차원 두부 방사선사진상의 각 계측점들이 3차원적으로 어느 정도의 정확성을 가지고 재현되는지를 알아보았다. 그리고 두 방법에 있어서의 계측점간의 거리계측을 실계측과 비교분석 함으로써 악안면부에서의 재현성과 정확성을 알아본 결과 다음과 같은 결과를 얻었다. 3-D CT와 3차원 두부 방사선사진상의 계측점들은 반복 계측시 각각 X축 방향으로 0.23 mm와 0.30 mm, Y축 방향으로 0.27 mm와 0.25 mm, 그리고 Z축 방향으로 0.27 mm와 0.31 mm의 표준편차를 보였다. 두 방법에서 모든 계측점이 0.5 mm 이하의 표준편차를 보였으며, 대부분의 계측점이 1 mm 이하의 범위를 보인 바, 두 방법 모두 통일한 건조두개골상의 계측점의 3차원적 위치 편차가 거의 없었다. 모든 계측항목에서 실측치와 3-D CT간의 차이는 평균 0.33 mm였으며, 실측치와 3차원 두부 방사선사진간의 차이는 평균 1.13 mm로 상대적으로 높게 나타났다. 가장 큰 차이를 보인 항목은 RGo과 LGo간으로 2.03 mm의 차이를 보였다. 그러나 두 방법 모두 모든 항목에서 실측치와 통계적으로 매우 높은 상관관계를 보였다(${\gamma}=0.976{\sim}1.000$, p<0.01).

  • PDF

Clinical Comparison of the Predictive Value of the Simple Skull X-Ray and 3 Dimensional Computed Tomography for Skull Fractures of Children

  • Kim, Young-Im;Cheong, Jong-Woo;Yoon, Soo Han
    • Journal of Korean Neurosurgical Society
    • /
    • 제52권6호
    • /
    • pp.528-533
    • /
    • 2012
  • Objective : In the pediatric population the skull has not yet undergone ossification and it is assumed that the diagnostic rate of skull fractures by simple X-rays are lower than that of adults. It has been recently proposed that the diagnostic rates of skull fractures by 3-dimensional computer tomography (3D-CT) are higher than simple X-rays. The authors therefore attempted to compare the diagnostic rates of pediatric skull fractures by simple X-rays and 3D-CTs with respect to the type of fracture. Methods : One-hundred patients aged less than 12 years who visited the Emergency Center for cranial injury were subject to simple X-rays and 3D-CTs. The type and location of the fractures were compared and Kappa statistical analysis and the t-test were conducted. Results : Among the 100 pediatric patients, 65 were male and 35 were female. The mean age was $50{\pm}45$ months. 63 patients had simple skull fractures and 22 had complex fractures, and the types of fractures were linear fractures in 74, diastatic fractures 15, depressed fractures in 10, penetrating fracture in 1, and greenstick fractures in 3 patients. Statistical difference was observed for the predictive value of simple skull fractures' diagnostic rate depending on the method for diagnosis. A significant difference of the Kappa value was noted in the diagnosis of depressed skull fractures and diastatic skull fractures. Conclusion : In the majority of pediatric skull fractures, 3D-CT showed superior diagnosis rates compared to simple skull X-rays and therefore 3D-CT is recommended whenever skull fractures are suspected. This is especially true for depressed skull fractures and diastatic skull fractures.

전산화단층상을 이용한 안면골의 3차원재구성상의 비교 연구 (COMPARATIVE STUDY OF THREE-DIMENSIONAL RECONSTRUCTIVE IMAGES OF FACIAL BONE USING COMPUTED TOMOGRAPHY)

  • 송남규;고광준
    • 치과방사선
    • /
    • 제22권2호
    • /
    • pp.283-290
    • /
    • 1992
  • The purpose of this study was to evaluate the spatial relationship of facial bone more accurately. For this study, the three-dimensional images of dry skull were reconstructed using computer image analysis system and three-dimensional reconstructive program involved CT. The obtained results were as follows: 1. Three-dimensional reconstructive CT results in images that have better resolution and more contrast 2. It showed good marginal images of anatomical structure on both three-dimensional CT and computer image analysis system, but the roof of orbit, the lacrimal bone and the squamous portion of temporal bone were hardly detectable. 3. The partial loss of image data were observed during the regeneration of saved image data on three-dimensional CT. 4. It saved the more time for reconstruction of three-dimensional images using computer image analysis system. But, the capacity of hardware was limited for inputting of image data and three-dimensional reconstructive process. 5. We could observe the spatial relationship between the region of interest and the surrounding structures by three-dimensional reconstructive images without invasive method.

  • PDF

삼차원 전산화단층촬영사진과 측모두부 방사선규격사진의 계측자에 따른 계측오차에 대한 비교분석 (Comparison of the observer reliability of cranial anatomic landmarks based on cephalometric radiograph and three-dimensional computed tomography scans)

  • 김재영;이동근;이상한
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제36권4호
    • /
    • pp.262-269
    • /
    • 2010
  • Introduction: Accurate diagnosis and treatment planning are very important for orthognathic surgery. A small error in diagnosis can cause postoperative functional and esthetic problems. Pre-existing 2-dimensional (D) chephalogram analysis has a high likelihood of error due to its intrinsic and extrinsic problems. A cephalogram can also be inaccurate due to the limited anatomic points, superimposition of the image, and the considerable time and effort required. Recently, an improvement in technology and popularization of computed tomography (CT) provides patients with 3-D computer based cephalometric analysis, which complements traditional analysis in many ways. However, the results are affected by the experience and the subject of the investigator. Materials and Methods: The effects of the sources human error in 2-D cephalogram analysis and 3-D computerized tomography cephalometric analysis were compared using Simplant CMF program. From 2008 Jan to 2009 June, patients who had undergone CT, cephalo AP, lat were investigated. Results: 1. In the 3 D and 2 D images, 10 out of 93 variables (10.4%) and 11 out 44 variables (25%), respectively, showed a significant difference. 2. Landmarks that showed a significant difference in the 2 D image were the points frequently superimposed anatomically. 3. Go Po Orb landmarks, which showed a significant difference in the 3 D images, were found to be the artificial points for analysis in the 2 D image, and in the current definition, these points cannot be used for reproducibility in the 3 D image. Conclusion: Generally, 3-D CT images provide more precise identification of the traditional cephalometric landmark. Greater variability of certain landmarks in the mediolateral direction is probably related to the inadequate definition of the landmarks in the third dimension.