• Title/Summary/Keyword: 3-dimensional CAD

Search Result 341, Processing Time 0.023 seconds

Performance evaluation of vessel extraction algorithm applied to Aortic root segmentation in CT Angiography (CT Angiography 영상에서 대동맥 추출을 위한 혈관 분할 알고리즘 성능 평가)

  • Kim, Tae-Hyong;Hwang, Young-sang;Shin, Ki-Young
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.9 no.2
    • /
    • pp.196-204
    • /
    • 2016
  • World Health Organization reported that heart-related diseases such as coronary artery stenoses show the highest occurrence rate which may cause heart attack. Using Computed Tomography angiography images will allow radiologists to detect and have intervention by creating 3D roadmapping of the vessels. However, it is often complex and difficult do reconstruct 3D vessel which causes very large amount of time and previous researches were studied to segment vessels more accurate automatically. Therefore, in this paper, Region Competition, Geodesic Active Contour (GAC), Multi-atlas based segmentation and Active Shape Model algorithms were applied to segment aortic root from CTA images and the results were analyzed by using mean Hausdorff distance, volume to volume measure, computational time, user-interaction and coronary ostium detection rate. As a result, Extracted 3D aortic model using GAC showed the highest accuracy but also showed highest user-interaction results. Therefore, it is important to improve automatic segmentation algorithm in future

A new method to measure the accuracy of intraoral scanners along the complete dental arch: A pilot study

  • Iturrate, Mikel;Lizundia, Erlantz;Amezua, Xabier;Solaberrieta, Eneko
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.6
    • /
    • pp.331-340
    • /
    • 2019
  • PURPOSE. The purpose of this study is to assess the accuracy of three intraoral scanners along the complete dental arch and evaluate the feasibility of the assessment methodology for further in vivo analysis. MATERIALS AND METHODS. A specific measurement pattern was fabricated and measured using a coordinate measuring machine for the assessment of control distances and angles. Afterwards, the pattern was placed and fixed in replica of an upper jaw for their subsequent scans (10 times) using 3 intraoral scanners, namely iTero Element1, Trios 3, and True Definition. 4 reference distances and 5 angles were measured and compared with the controls. Trueness and precision were assessed for each IOS: trueness, as the deviation of the measures from the control ones, while precision, as the dispersion of measurements in each reference parameter. These measurements were carried out using software for analyzing 3-dimensional data. Data analysis software was used for statistical and measurements analysis (α=.05). RESULTS. Significant differences (P<.05) were found depending on the intraoral scanner used. Best trueness values were achieved with iTero Element1 (mean from 10 ± 7 ㎛ to 91 ± 63 ㎛) while the worst values were obtained with Trios3 (mean from 42 ± 23 ㎛ to 174 ± 77 ㎛). Trueness analysis in angle measurements, as well as precision analysis, did not show conclusive results. CONCLUSION. iTero Element1 was more accurate than the current versions of Trios3 and True Definition. Importantly, the proposed methodology is considered reliable for analyzing accuracy in any dental arch length and valid for assessing both trueness and precision in an in vivo study.

Marginal and internal fit of 3D printed provisional crowns according to build directions

  • Ryu, Ji-Eun;Kim, Yu-Lee;Kong, Hyun-Jun;Chang, Hoon-Sang;Jung, Ji-Hye
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.4
    • /
    • pp.225-232
    • /
    • 2020
  • PURPOSE. This study aimed to fabricate provisional crowns at varying build directions using the digital light processing (DLP)-based 3D printing and evaluate the marginal and internal fit of the provisional crowns using the silicone replica technique (SRT). MATERIALS AND METHODS. The prepared resin tooth was scanned and a single crown was designed using computer-aided design (CAD) software. Provisional crowns were printed using a DLP-based 3D printer at 6 directions (120°, 135°, 150°, 180°, 210°, 225°) with 10 crowns in each direction. In total, sixty crowns were printed. To measure the marginal and internal fit, a silicone replica was fabricated and the thickness of the silicone impression material was measured using a digital microscope. Sixteen reference points were set and divided into the following 4 groups: marginal gap (MG), cervical gap (CG), axial gap (AG), and occlusal gap (OG). The measurements were statistically analyzed using one-way ANOVA and Dunnett T3. RESULTS. MG, CG, and OG were significantly different by build angle groups (P<.05). The MG and CG were significantly larger in the 120° group than in other groups. OG was the smallest in the 150° and 180° and the largest in the 120° and 135° groups. CONCLUSION. The marginal and internal fit of the 3D-printed provisional crowns can vary depending on the build angle and the best fit was achieved with build angles of 150° and 180°.

Evaluation of validity of three dimensional dental digital model made from blue LED dental scanner (Blue LED 방식의 스캐너로 제작된 치과용 3차원 디지털 모형의 정확도 평가)

  • Kim, Jae-Hong;Jung, Jae-Kwan;Kim, Ki-Baek
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.3007-3013
    • /
    • 2014
  • The objectives of this study was to evaluate the validity of 3D digital models made from blue LED dental scanner. Twenty same cases of stone models and 3d digital models were manufactured for this study. Intercanine distance, intermolar distance, two dental arch lengths(right, left) and two diagonal of dental arch lengths(right, left) were measured for evaluation of validity. The nonparametric Wilcoxon rank sum test was used for statistical analysis (${\alpha}$=0.05). Although stone models showed larger than digital models in all measured distances(p<0.05), none exceeded the clinically acceptable range.

Does the palatal vault form have an influence on the scan time and accuracy of intraoral scans of completely edentulous arches? An in-vitro study

  • Osman, Reham;Alharbi, Nawal
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.5
    • /
    • pp.294-304
    • /
    • 2022
  • PURPOSE. The purpose of this study was to evaluate the influence of different palatal vault configurations on the accuracy and scan speed of intraoral scans (IO) of completely edentulous arches. MATERIALS AND METHODS. Three different virtual models of a completely edentulous maxillary arch with different palatal vault heights- Cl I moderate (U-shaped), Cl II deep (steep) and Cl III shallow (flat)-were digitally designed using CAD software (Meshmixer; Autodesk, USA) and 3D-printed using SLA-based 3D-printer (XFAB; DWS, Italy) (n = 30; 10 specimens per group). Each model was scanned using intraoral scanner (Trios 3; 3ShapeTM, Denmark). Scanning time was recorded for all samples. Scanning accuracy (trueness and precision) were evaluated using digital subtraction technique using Geomagic Control X v2020 (Geomagic; 3DSystems, USA). One-way analysis of variance (ANOVA) test was used to detect differences in scanning time, trueness and precision among the test groups. Statistical significance was set at α = .05. RESULTS. The scan process could not be completed for Class II group and manufacturer's recommended technique had to be modified. ANOVA revealed no statistically significant difference in trueness and precision values among the test groups (P=.959 and P=.658, respectively). Deep palatal vault (Cl II) showed significantly longer scan time compared to Cl I and III. CONCLUSION. The selection of scan protocol in complex cases such as deep palatal vault is of utmost importance. The modified, adopted longer path scan protocol of deep vault cases resulted in increased scan time when compared to the other two groups.

Physical Properties and Virtual Cloth Images of Cotton Fabrics Treated with Chitosan, 1,2,3,4-Butanetetracarboxylic Acid and Citric Acid (키토산과 1,2,3,4-Butanetetracarboxylic Acid, Citric Acid로 가공된 면직물의 역학적 특성과 가상 봉제 이미지)

  • Kim, Kyung-Sun;Jeon, Dong-Won;Kim, Jong-Jun
    • Journal of Fashion Business
    • /
    • v.13 no.1
    • /
    • pp.102-114
    • /
    • 2009
  • Chitosan is a polysaccharide with cationic amino groups in its structure and has useful properties as functional materials. Various end-use developments of chitosan are in progress. When the cotton fabric is pretreated with chitosan, the hand property of cotton fabric may be improved expecially for the summer apparel. In this study, as a cross-linking agent to introduce chitosan into cotton, BTCA(butane-1,2,3,4-tetracarboxylic acid) or CA(citric acid) was added in order to prevent detachment of chitosan by the cross-linking. During the cross-linking procedure, via the padding-drying-heat setting, amino groups of chitosan and hydroxyl groups of cotton, carboxyl groups of BTCA/CA are cross-linked by forming anhydrous cyclic rings. Since BTCA has four carboxyl groups, cross-linking by thermal treatment is easy, leading to the trials in wrinkle-recovery treatment of cotton fabrics. However, the high price of the BTCA reagent has been a shortcoming in the actual application for industrial use. Therefore, in this study, we tried the application of CA having three carboxyl groups, which is relatively low priced, as the substituting cross-linking agent. The hand of the treated fabrics were evaluated by measuring physical properties. In addition, based on the physical properties, three-dimensional images were introduced by using 3D CAD systems and results were compared.

Functions and Roles of Digital Landscape Architectural Drawing (조경 설계에서 디지털 드로잉의 기능과 역할)

  • Lee, Myeong-Jun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.46 no.2
    • /
    • pp.1-13
    • /
    • 2018
  • This work discusses the major roles of digital technologies in the history of landscape architectural drawing, and offers a critique of the dominant trend towards realism in recent digital landscape representations. During the period of transition from conventional drawing tools, computer technologies generally functioned as mechanical tools to imitate prior manual techniques. Specifically, the GIS was served as a mechanical tool to efficiently process the manual layer cake; CAD software generally functioned to translate physical models to two-dimensional construction documents while graphic software generally functioned as a tool to perform processes similar to those of manual collage and montage techniques. Recent digital landscape drawings tend to adopt a realistic depiction like the painting of landscape appearance. In the representations, discernible traces of cutting and assembling are removed via graphic software; thus, the complete representations are perceived as if they were a copy of an actual landscape. The realistic images are an easy way to communicate with the public. However, it is difficult to achieve a full embodiment of all of the multisensory characteristics of a landscape through these visuals. They often deceive viewers by visualizing idealized conditions of not-yet-actualized landscapes and production of the final images takes up a large portion of the overall design process. Alternatively, 3D digital modeling of landscape performance and creative uses of digital technologies during the overall design process, as well as hybridized techniques with different drawing techniques and technologies, provide the opportunity to explore various aspects of a landscape.

The Influence of Different Gypsum Materials on the Accuracy from Complete Arch Digital Impression (전악의 디지털 인상 채득 시 치과용 모형재가 디지털 모형 정확성에 미치는 영향)

  • Kim, Ki-Baek;Lee, Gyeong-Tak;Kim, Hae-Young;Kim, Jae-Hong
    • Journal of dental hygiene science
    • /
    • v.12 no.6
    • /
    • pp.617-623
    • /
    • 2012
  • This study was performed to measure the accuracy of different gypsum materials by a white light dental scanner. A master model with the prepared lower full arch tooth was used. The type IV and scannable stone were used for 20 stone casts (10 casts each) duplicated a master model of mandible. The distance between the reference points were measured and analyzed by the Delcam $Copycad^{(R)}$ (Delcam Plc, UK) 3D graphic software. The t-student test for paired samples were used for statistical analysis. The mean differences to master model for type IV stone and scannable stone model were 0.29~0.56 mm, and 0.17~0.35 mm, respectively. There were statistical differences in dimensional accuracy for full arch impression between the master model and type IV/scannable stone (p<0.05). Two different gypsum materials showed clinically acceptable accuracies of full arch digital impression produced by them. Besides, in both gypsum materials, the differences to the master model detected appear to provide enough accuracy for clinical application.

Comparative study of volumetric change in water-stored and dry-stored complete denture base (공기중과 수중에서 보관한 총의치 의치상의 체적변화에 대한 비교연구)

  • Kim, Jinseon;Lee, Younghoo;Hong, Seoung-Jin;Paek, Janghyun;Noh, Kwantae;Pae, Ahran;Kim, Hyeong-Seob;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.18-26
    • /
    • 2021
  • Purpose: Generally, patients are noticed to store denture in water when removed from the mouth. However, few studies have reported the advantage of volumetric change in underwater storage over dry storage. To be a reference in defining the proper denture storage method, this study aims to evaluate the volumetric change and dimensional deformation in case of underwater and dry storage. Materials and methods: Definitive casts were scanned by a model scanner, and denture bases were designed with computer-aided design (CAD) software. Twelve denture bases (upper 6, lower 6) were printed with 3D printer. Printed denture bases were invested and flasked with heat-curing method. 6 upper and 6 lower dentures were divided into group A and B, and each group contains 3 upper and 3 lower dentures. Group A was stored dry at room temperature, group B was stored underwater. Group B was scanned at every 24 hours for 28 days and scanned data was saved as stereolithography (SLA) file. These SLA files were analyzed to measure the difference in volumetric change of a month and Kruskal-Wallis test were used for statistical analysis. Best-fit algorithm was used to overlap and 3-dimensional color-coded map was used to observe the changing pattern of impression surface. Results: No significant difference was found in volumetric changes regardless of the storage methods. In dry-stored denture base, significant changes were found in the palate of upper jaw and posterior lingual border of lower jaw in direction away from the underlying tissue, maxillary tuberosity of upper jaw and retromolar pad area of lower jaw in direction towards the underlying tissue. Conclusion: Storing the denture underwater shows less volumetric change of impression surface than storing in the dry air.

Development of Prototyping and Die/Mold Manufacturing Technology using Rapid Prototyping(SLA) (쾌속 3차원 조형법을 이용한 시작기술 및 시작금형)

  • Park, K.;Lee, S.C.;Jung, J.H.;Yang, D.Y.;Yoon, J.R.
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.5
    • /
    • pp.1582-1589
    • /
    • 1996
  • Rapid prototyping is a new prototyping technology which produces three dimensional part models directrly from CAD data and has been extensively applied to various manufacturing processes. There are many types of rapid prototyping systems due to their building principles and materials. In this work, Stereolithography Appaaratus(SLA) which is the most widely-used rapid prototyping system is introduced to achieve die/mold technology innovation. For the purpose, the prototyping technology using SLA is developed such that patterns of which shapes are quite complicated are successfully produced with high accuracy. Using these patterns, prototype die/molds are efficientrly manufactured; a turbocharger rotor, a fan and a wheel patterns, prototype die/molds are efficienterly manufactured ; a turbochager rotor, a fan and a wheel pattern are made, and the molds of the investment casting, the injection molding and the die casting are manufactured respectively. The casting products are produced using these molds and it turns out that these methods are quitre effective for manufacturing products of complicated geometry from the viewpoint of efficiency and productivity.