• Title/Summary/Keyword: 3-Hole Tube

Search Result 74, Processing Time 0.026 seconds

Quasi-monochromatic Parallel Radiography Achieved with a Polycapillary Plate

  • Sato, Eiichi;Komatsu, Makoto;Hayasi, Yasuomi;Tanaka, Etsuro;Mori, Hidezo;Kawai, Toshiaki;Ichimaru, Toshio;Takayama, Kazuyoshi;Ido, Hideaki
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.418-421
    • /
    • 2002
  • Fundamental study on quasi-monochromatic parallel radiography using a polycapillary plate and a plane-focus x-ray tube is described. The x-ray generator consists of a negative high-voltage power supply, a filament (hot cathode) power supply, and an x-ray tube. The negative high-voltage is applied to the cathode electrode, and the transmission type target (anode) is connected to the ground potential. The maximum voltage and current of the power supply were -100 kV (peak value) and 3.0 mA, respectively. In this experiment, the tube voltage was regulated from 20 to 25 kV, and the tube current was regulated by the filament temperature and ranged from 1.0 to 3.0 mA. The exposure time is controlled in order to obtain optimum film density, and the focal spot diameter was about 10 mm. The polycapillary plate is J5022-21 made by Hamamatsu Photonics Inc., and the outside and effective diameters are 87 and 77 mm, respectively. The thickness and the hole diameter of the polycapillary are 1.0 mm and 25 ${\mu}$m, respectively. The x-rays from the tube are formed into parallel beam by the polycapillary, and the radiogram is taken using an industrial x-ray film of Fuji IX 100 without using a screen. In the measurement of image resolution, we employed three brass spacers of 2, 30, and 60 mm in height. By the test chart, the resolution fell according to increases in the spacer height without using a polycapillary. In contrast, the resolution slightly fell with corresponding increases in the height by the polycapillary. In angiography, fine blood vessels of about 100 ${\mu}$m are clearly visible.

  • PDF

A Study on the Exhaust Reduction of Diesel Particulates Using Ceramic Fiber Filters (세라믹 섬유필터를 이용한 디젤 입자상물질 배출저감에 관한 기초연구)

  • 주용남;홍민선;문수호;이동섭;임우택
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.3
    • /
    • pp.297-306
    • /
    • 2003
  • Works were focused on back pressure characteristics of ceramic fiber filter on DPF (Diesel Particulate Filter) system and experiments were performed to select appropriate filter which can filter particulates. Filters were installed on metal -support tube which has openings for exhaust gas flow. Ceramic fiber filters with high specific surface area and adequate high temperature strength are commercially available for filtration of diesel particulates and in -situ hot regeneration. Thus, ceramic blanket and ceramic board which are used as insulating media were applied to filter and filtration apparatus was installed on exhaust gas line connected to 2.0 L diesel engine. Alternating filter structure to adapt DPF system, collection efficiency test of diesel particulates was measured. In case of ceramic blanket, pressure drop was low, caused by the destruction of soft structures. Also, particulate collection efficiency was decreased depending on loading time. In case of ceramic board, structure design was altered to reduce back pressure on DPF system. Structure design was altered to induce Z-flow by making 10 mm and 5 mm holes on the surface of media. Alteration of 5 mm hole showed that media have low back pressure but particulate collection efficiency was 77%, while 10 mm hole showed that of 90%.

A Study on the Relation Between Expansion and the Characteristics of Surface in the ED-Drilling (방전드릴의 방전갭과 표면특성에 관한 연구)

  • Choi, Jong-Yeun;Kim, Kyeong-Hwan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.3
    • /
    • pp.73-79
    • /
    • 2012
  • This paper describes the machining characteristics of the sintered carbide and die steel(STD-11) by electric discharge drilling with various tubular electrodes. Electrical discharge machining(EDM) removes material from the workpiece by a series of electrical sparks that cause localized temperatures high enough to melt or vapourize the vicinity of the charge. In the experiment. four types of electrode which have different diameter are used with the application of continuous direct current and axial electrode feed. The controlled factors include the dimension of the electrode. In drilling by EDM, the dielectric flushed down the interior of the rotating tube electrode, in order to order to facilitate the removal of machining debris the hole. The expansion increase with increasing the thickness of material and the diameter of electrode and the expansion of sintered carbide is 1.75 times large then that of die steel. The taper of machined hole decrease with increasing the thickness of material. The crater sixe of die steel is larger then thet of sintered carbide and the surface roughness of sintered carbide is 1.58 tims larger then that of die steel.

An Experimental Study for Flow Characteristics Inside the Rotor of a Multiblade Fan/Scroll System (다익 팬/스크롤 시스템의 로터 내부 유동 특성에 관한 실험적 연구)

  • Maeng, Joo-Sung;Yoon, Joon-Yong;Ahn, Tae-Beom;Yoon, Jong-Eun;Hahn, Doug-Jeon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.5
    • /
    • pp.646-652
    • /
    • 1999
  • Detailed characteristics of the mean flow field inside the rotor of a multiblade fan with scroll are presented in this paper by measurements and visualizations. The measurements were taken with a five-hole probe and conformed by smoke test. How field is distinguished clearly in 3 regions with respect to the flow directions. The first region is near the exit of scroll where the fluid flows the opposite direction to the rotation of rotor. The second is opposite side of the scroll exit where the fluid flows the same direction to the rotation of rotor. The third is the region where the fluid flows toward the blades directly with the largest values comparatively. The strongest recirculation is happened in the second region, and the weakest one is in the third region. This complex configuration makes the flow field highly non-uniform and may cause to generate a noise and ineffective flow efficiency.

Sensitivity Analysis of Nozzle Geometry Variables for Estimating Residual Stress in RPV CRDM Penetration Nozzle (원자로 상부헤드 관통노즐의 잔류응력 예측을 위한 노즐 형상 변수 민감도 연구)

  • Bae, Hong Yeol;Oh, Chang Young;Kim, Yun Jae;Kim, Kwon Hee;Chae, Soo Won;Kim, Ju Hee
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.3
    • /
    • pp.387-395
    • /
    • 2013
  • Recently, several circumferential cracks were found in the control rod drive mechanism (CRDM) nozzles of U.S. nuclear power plants. According to the accident analyses, coolant leaks were caused by primary water stress corrosion cracking (PWSCC). The tensile residual stresses caused by welding, corrosion sensitive materials, and boric acid solution cause PWSCC. Therefore, an exact estimation of the residual stress is important for reliable operation. In this study, finite element simulations were conducted to investigate the effects of the tube geometry (thickness and radius) on the residual stresses in a J-groove weld for different CRDM tube locations. Two different tube locations were considered (center-hole and steepest side hill tube), and the tube radius and thickness variables ($r_o/t$=2, 3, 4) included two different reference values ($r_o$=51.6, t=16.9mm).

An Experimental Study on the Supersonic Jet Noise from Multihole (다공 초음속 분류소음에 관한 실험적 연구)

  • Kwon, Y.P.;Suh, K.W.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.4 no.2
    • /
    • pp.96-105
    • /
    • 1992
  • The objective of this paper is to study experimentally on the noise characteristics of supersonic jet from multihole orifice in the range of jet pressure from $at_g$ to $at_g$ in the reverberation room. At first, the single orifice jets are investigated for various hole diameter from 3.8mm to 10mm. Through the noise spectrum, the turbulent mixing noise and the shock associated noise is analyzed. The noise for confined jets into a tube of diameter 30mm or 90mm with length 2m is investigated in comparision with that for the free jets. The sound power level is measured and compared with thoretical models for free jet. At second, multihole orifice jets are investigated to study the effect of multijet on noise reduction. The spectrum and power level of multijets are measured and compared with single jets. The multi-jets in a confined pipe are also investigated. It is found that the noise spectrum is significantly altered by increasing the number of jet with decrease in jet diameter and also by confining the jet into tube.

  • PDF

MEMS for Heterogeneous Integration of Devices and Functionality

  • Fujita, Hiroyuki
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.7 no.3
    • /
    • pp.133-139
    • /
    • 2007
  • Future MEMS systems will be composed of larger varieties of devices with very different functionality such as electronics, mechanics, optics and bio-chemistry. Integration technology of heterogeneous devices must be developed. This article first deals with the current development trend of new fabrication technologies; those include self-assembling of parts over a large area, wafer-scale encapsulation by wafer-bonding, nano imprinting, and roll-to-roll printing. In the latter half of the article, the concept towards the heterogeneous integration of devices and functionality into micro/nano systems is described. The key idea is to combine the conventional top-down technologies and the novel bottom-up technologies for building nano systems. A simple example is the carbon nano tube interconnection that is grown in the via-hole of a VLSI chip. In the laboratory level, the position-specific self-assembly of nano parts on a DNA template was demonstrated through hybridization of probe DNA segments attached to the parts. Also, bio molecular motors were incorporated in a micro fluidic system and utilized as a nano actuator for transporting objects in the channel.

Development of Imaging Gamma Probe Using the Position Sensitive PMTube (위치 민감형 광전자증배관을 이용한 영상용 감마프로브의 개발)

  • Bong, Jeong-Gyun;Kim, Hui-Jung;So, Su-Gil;Kim, Han-Myeong;Lee, Jong-Du;Gwon, Su-Il
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.1
    • /
    • pp.107-113
    • /
    • 1999
  • The purpose of this study was to develop a miniature imaging gamma probe with high performance that can detect small or residual tumors after surgery. Gamma probe detector system consists of NaI(Tl) scintillator, position sensitive photomultiplier tube (PSPMT), and collimator. PSPMT was optically coupled with 6.5 mm thick, 7.62 cm diameter of NaI(Tl) crystal and supplied with -1000V for high voltage. Parallel hexagonal hole collimator was manufactured for characteristics of 40-mm hole length, 1.3-mm hole diameter, and 0.22 mm septal thickness. Electronics consist of position and trigger signal readout systems. Position signals were obtained with summing, subtracting, and dividing circuit using preamplifer and amplifier. Trigger signals were obtained using summing amplifier, constant fraction discriminator, and gate and delay generator module with preamplifer. Data acquisition and processing were performed by Gamma-PF interface board inserted into pentium PC and PIP software. For imaging studies, flood and slit mask images were acquired using a point source. Two hole phantom images were also acquired with collimator. Intrinsic and system spatial resolutions were measured as 3.97 mm and 5.97 mm, respectively. In conclusion, Miniature gamma probe images based on the PSPMT showed good image quality, we conclude that the miniature imaging gamma probe was successfully developed and good image data were obtained. However, further studies will be required to optimize imaging characteristics.

  • PDF

The Study on the Production Method of Stepwise Dilution Gas for Odor Analysis with Orifice Tubes (오리피스 튜브에 의한 단계별 냄새 분석용 희석가스의 제조방법에 관한 연구)

  • Kim, Han-Soo;Lee, Seok-Jun;Kim, Sun-Tae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.2
    • /
    • pp.137-143
    • /
    • 2013
  • This study is to develop the production method of stepwise dilution gas for the evaluation of complex odor concentration by orifice tube. The basic orifice tube for 10 and 30 times of dilution sample was made at first, and with the combination of the basic orifice tubes we can continuously manufacture the stepwise dilution sample gas for air dilution sensory test ; 10, 30, 100, 300, 1,000, 3,000 times etc. The hole size of orifice tube was 0.84 mm for 10 times of dilution sample, and was 0.34 mm for 30 times. Dilution sample gas made with the basic orifice tube have an excellent reproducibility, 2%RSD. In addition, over 90% of correlation was shown between the sample made by the orifice tube and the sample by the syringe dilution method. Because there was no concentration drift of dilution gas with changes of connected pump flow, the basic orifice tube could be mounted directly with a vacuum suction box, and could be used simply as a tool for the evaluation of odor, especially on site.

Tension test considering the shape change of CFT Column-to-Beam Interior Diaphragm (CFT 기둥-보 내다이아프램의 형상변화를 고려한 인장실험)

  • Kwak, Sung-Shin;Choi, Byong-Jeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.2
    • /
    • pp.67-75
    • /
    • 2019
  • The diaphragm used for CFT columns has a small amount of steel to be used, but has a disadvantage that welding is difficult and openings are required because the steel tube and four sides must be welded. The improved diaphragm to be examined in this study was cut into four corners by cutting the center hole for concrete filling. In the improved diaphragm, the width of the center hole is the same as that of the previous diaphragm, but the width of the diaphragm contacting the steel tube is reduced, thereby reducing the welding length by about 70% compared to the previous diaphragm. The in-plane strain of each specimen was analyzed when the same load was applied to the interior diaphragm through a simple tensile test. Using the general FEM program(ANSYS 19.2), the analysis was performed under the same conditions as the actual simple tensile test, and the load transfer between the improved diaphragm and the previous diaphragm was compared. When the width of the diaphragm is equal to or smaller than the flange width, stress is concentrated from the end of the diaphragm, and when the flange width is larger, stress is concentrated at the center.