• Title/Summary/Keyword: 3-Dimensional Measurement

Search Result 1,256, Processing Time 0.033 seconds

Realization for Automatic Stock Cubic Measuring and Distributing Management Embedded System with 3D Ultrasonic Sensing (3D 초음파센싱 자동물류부피측정 및 분류관리 임베디드시스템 구현)

  • Lee, Eun-Eok;Ryu, Kwang-Rryol;Hur, Chang-Wu
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.285-288
    • /
    • 2007
  • A realization for automatic stock cubic measuring and distributing management embedded system with 3 dimensional ultrasonic sensing is presented in this paper. The height and width of cubic are measured by comparing the 3 values from 3 ultrasonic sensors with reference when an object is passing the conveyer and length is calculated by the passing time and velocity, compensate cubic values for error to vary with the environment temperature, and reduce the error by averaging the sensing data not to be right posture of object. The system enables to classify and load a packed stocks at the store and transportation practically based on the rectangular hexahedral objects.

  • PDF

Synthesis and Characterization of Tetrathiafulvalene Charge Transfer Compounds with Iron and Antimony Halides

  • Kim Young In;Choi Sung Nak;Jung Woo Sung
    • Bulletin of the Korean Chemical Society
    • /
    • v.15 no.6
    • /
    • pp.465-468
    • /
    • 1994
  • The charge transfer compounds $(TTF)_4FeCl_3{\cdot}CH_3OH,\;(TTF)_4SbCl_4\;and\;(TTF)_5(SbBr_4)_2{\cdot}CH_3COCH_3$ were prepared from reactions of the TTF (tetrathiafulvalene) and metal halides. The compounds were characterized by spectroscopic (UV,IR, EPR and XPS) methods, magnetic susceptibility and electrical conductivity measurements. The d.c electrical conductivities of the pressed pellets are in the order of $10^{-1}-10^{-3} Scm^{-1}$, which lies in the range of semiconductor region at room temperature. It means that the partially ionized TTF has stacked in low-dimensional chain in each compound. Spectroscopic properties also indicate that TTF molecules are partially ionized and charge transfer has occurred from (TTF)n to Fe(III) center in $(TTF)_4FeCl_3{\cdot}CH_3OH$ whereas to the $-SbX_4^-$ entity in $(TTF)_4SbCl_4\;and\;(TTF)_5(SbBr_4)_2{\cdot}CH_3COCH_3$. The EPR g values are consistent with TTF radical formation and EPR linewidths suggest the delocalization of unpaired electrons along TTF stacks. A signal arised from metal (Fe and Sb) ions were not detected in EPR spectra, indicating that metal ion is in the diamagnetic state in each compound. The diamagnetic state was also examined by the magnetic susceptibility measurement. The magnetic properties reveal the significant interaction between the $TTF^+$ radical cations in the stacks. The oxidation state of metal ions was also investigated by XPS spectra.

Three-dimensional CT image study on the correction of gonial angle width enlarged on frontal cephalogram (정모두부방사선사진에서 하악골 우각부 영상확대 및 이의 보정에 관한 3차원 CT영상 연구)

  • Hwang, Hyeon-Shik;Eun, Chun-Sun;Hwang, Chung Hyon;Lim, Hoi-Jeong
    • The korean journal of orthodontics
    • /
    • v.35 no.4 s.111
    • /
    • pp.251-261
    • /
    • 2005
  • Enlargement is an inherent property of X-rays which occurs when straight hues diverse from small a focal spot. The purpose of the present study was to evaluate the validity of the correction of gonial angle width enlarged on frontal cephalogram, using frontal and lateral cephalograms taken orthogonally from each other. In 40 adult individuals, frontal and lateral cephalograms were taken at a $90^{\circ}$ angle using the Head Posture Aligner. The angle width was measured on the frontal cephalogram and subsequently. the corrected angle width was calculated using the magnification rate of two cephalograms. Measured and corrected angle widths were compared with the measurement from the 3D CT image. The measurement or the frontal cephalogram showed a 9.10mm of enlargement on average ranging from 7.92 to 11.31mm. Corrected angle width measurement showed a 0.14mm difference with the 3D CT image measurement, which was not statistically significant. The results of the study indicate that actual au91e width can be approached through calculation using frontal and lateral cephalograms taken orthogonally with the help of the Head Posture Aligner The study also showed that the magnitude of correction error did not show a significant correlation with the amount of menton deviation, and it suggests that the present correction method is valid even in individuals with severe facial asymmetry.

A Study on the Measurement of Gas Discharge from the Gas Vent of Sanitary Landfill(1)- analysis for minimizing the measurement error of flow meter - (쓰레기 매립지 가스포집관에서 유출가스 계측에 관한 연구(1) -유량계 계측오차의 최소화를 위한 해석 -)

  • 이해승;이찬기
    • Journal of Korea Soil Environment Society
    • /
    • v.3 no.1
    • /
    • pp.83-92
    • /
    • 1998
  • This study presents a relationship between gas quantity and measurement resistance using the bubble meter, the water head indicator and the rotor meter from the gas vent sanitary landfill. From the one-dimensional analyses and experiments, the below results have been obtained. The gas volume sourcing from the gas vent depends on the permeability of final cover soil, its cover depth and distance between the gas vents. The total gas volume producing in the interested domain may be accurately measured by the bubble meter, the water head indicator and the rotor meter if the clay is used for the final cover soil. The required times approaching to the steady-state are different with respect to the flow meters, one day is for the bubble meter and the water head indicator and one hour for the rotor meter.

  • PDF

The Severity DB Construction for Unpaved Road Through Measuring 3D Road Profile (3차원 노면굴곡 측정을 통한 운용지역 비포장 기동로의 가혹도 DB 구축)

  • Lee, Jeonghwan;Lee, Sangho;Cho, Jinwoo;Kang, Esok
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.231-237
    • /
    • 2017
  • The profile of unpaved road is an important issue in the reliability of endurance test. Efforts on measuring 2D road profile and analyzing the severity have been continued in the study of performing reliable endurance test evaluations through reflecting the results of such measurement and analysis. However, 2D road profile has limitation in measuring the profile in the road width direction because data is obtained along the trailer wheel track. Therefore, in order to measure 3-dimensional shape of road surface and construct severity DB of 3D road profile, Changwon Proving Ground(CPG) of Agency for Defense Development(ADD) developed 3D profilometer which is composed of laser scanner, IMU, GPS, encoder and so on. This paper focuses on the analysis of unpaved road severity using 3D road profile for army operation roads. This results will be used to manage test courses severity of CPG.

Study on Appropriateness of a Remote Facility for Discharge Measurement in Small Stream by 3-Dimensional Flow Analysis (3차원 흐름해석을 통한 소하천 원격유량측정시설의 적정성 연구)

  • Kim, Jong-Chan;Hong, Kee-Hoon;Ko, Jae-Min;Kim, Chin-Min
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.457-461
    • /
    • 2010
  • 소하천에서의 효율적인 유량측정 수행을 위해서 K-water(한국수자원공사) 충청지역본부에서는 금강유역의 보청천 지류인 곰쟁이천에 원격유량측정시설 개념의 위어(weir)를 이용한 고정단면 시설물을 2006년도에 설치하였으며, 2007년부터 2009년까지 시설물 직하류에서 도섭을 통한 유량측정을 실시하였고 3차원 흐름해석 결과와의 비교를 통해 소하천 원격유량측정시설의 적정성을 분석하였다. 총 55회의 유량측정 성과를 이용하여 수위-유량 관계곡선식을 산정하였으며, FLOW-3D를 이용하여 3차원 흐름해석을 실시하였다. Francis 유량산정 공식인 Q=$1.84bH^{3/2}$을 통해 계산되는 수위별 유량, 유량측정 성과에 의한 수위-유량 관계곡선식, 그리고 FLOW-3D로부터 계산된 수위별 유량을 비교하였으며, 실측유량과 계산된 유량의 차이를 비교 검토하였다. 이러한 비교 검토를 통해 소유량 구간에 대해서는 원격유량측정시설의 적정성을 확인할 수 있었으며, 갈수시 미소유량이 흐르는 소하천에 위치한 지점에 대해서는 인력 및 비용이 많이 소요되는 도섭을 통한 직접 유량측정 수행보다는 검증된 유량측정시설(위어, 파샬플룸 등)을 통한 유량측정이 더욱 효과적인 것으로 판단되었다.

  • PDF

THREE DIMENSIONAL FINITE ELEMENT STRESS ANALYSIS OF IMPLANT PROSTHESIS ACCORDING TO THE DIFFERENT FIXTURE LOCATIONS AND ANGULATIONS (임플랜트 지지 보철물에서 고정체의 식립위치와 각도에 따른 삼차원 유한요소법적 응력분석에 관한 연구)

  • Park Won-Hee;Lee Young-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.1
    • /
    • pp.61-77
    • /
    • 2005
  • Statement of problem. The implant prosthesis has been utilized in various clinical cases thanks to its increase in scientific effective application. The relevant implant therapy should have the high success rate in osseointegration, and the implant prosthesis should last for a long period of time without failure. Resorption of the peri-implant alveolar bone is the most frequent and serious problem in implant prosthesis. Excessive concentration of stress from the occlusal force and biopressure around the implant has been known to be the main cause of the bone destruction. Therefore, to decide the location and angulation of the implant is one of the major considering factors for the stress around the implant fixture to be dispersed in the limit of bio-capacity of load support for the successful and long-lasting clinical result. Yet, the detailed mechanism of this phenomenon is not well understood. To some extent, this is related to the paucity of basic science research. Purpose. The purpose of this study is to perform the stress analysis of the implant prosthesis in the partially edentulous mandible according to the different nature locations and angulations using three dimensional finite element method. Material and methods, Three 3.75mm standard implants were placed in the area of first and second bicuspids, and first molar in the mandible Thereafter, implant prostheses were fabricated using UCLA abutments. Five experimental groups were designed as follows : 1) straight placement of three implants, 2) 5$^{\circ}$ buccal and lingual angulation of straightly aligned three implants, 3) 10$^{\circ}$ buccal and lingual angulation of straightly aligned three implants. 4) lingual offset placement of three implants, and 5) buccal offset placement of three implants. Average occlusal force with a variation of perpendicular and 30$^{\circ}$ angulation was applied on the buccal cusp of each implant prosthesis, followed by the measurement of alteration and amount of stress on each configurational implant part and peri-implant bio-structures. The results of this study are extracted from the comparison between the distribution of Von mises stress and the maximum Von mises stress using three dimensional finite element stress analysis for each experimental group. Conclusion. The conclusions were as follows : 1. Providing angulations of the fixture did not help in stress dispersion in the restoration of partially edentulous mandible. 2. It is beneficial to place the fixture in a straight vertical direction, since bio-pressure in the peri-implant bone increases when the fixture is implanted in an angle. 3. It is important to select an appropriate prosthodontic material that prevents fractures, since the bio-pressure is concentrated on the prosthodontic structures when the fixture is implanted in an angle. 4. Offset placement of the fixtures is effective in stress dispersion in the restoration of partially edentulous mandible.

Strategies about Optimal Measurement Matrix of Environment Factors Inside Plastic Greenhouse (플라스틱온실 내부 환경 인자 다중센서 설치 위치 최적화 전략)

  • Lee, JungKyu;Kang, DongHyun;Oh, SangHoon;Lee, DongHoon
    • Journal of Bio-Environment Control
    • /
    • v.29 no.2
    • /
    • pp.161-170
    • /
    • 2020
  • There is systematic spatial variations in environmental properties due to sensitive reaction to external conditions at plastic greenhouse occupied 99.2% of domestic agricultural facilities. In order to construct 3 dimensional distribution of temperature, relative humidity, CO2 and illuminance, measurement matrix as 3 by 3 by 5 in direction of width, height and length, respectively, dividing indoor space of greenhouse was designed and tested at experimental site. Linear regression analysis was conducted to evaluate optimal estimation method in terms with horizontal and vertical variations. Even though sole measurement point for temperature and relative humidity could be feasible to assess indoor condition, multiple measurement matrix is inevitably required to improve spatial precision at certain time domain such as period of sunrise and sunset. In case with CO2, multiple measurement matrix could not successfully improve the spatial predictability during a whole experimental period. In case with illuminance, prediction performance was getting smaller after a time period of sunrise due to systematic interference such as indoor structure. Thus, multiple sensing methodology was proposed in direction of length at higher height than growing bed, which could compensate estimation error in spatial domain. Appropriate measurement matrix could be constructed considering the transition of stability in indoor environmental properties due to external variations. As a result, optimal measurement matrix should be carefully designed considering flexibility of construction relevant with the type of property, indoor structure, the purpose of crop and the period of growth. For an instance, partial cooling and heating system to save a consumption of energy supplement could be successfully accomplished by the deployment of multiple measurement matrix.

DEVELOPMENT OF THREE DIMENSIONAL MEASURING PROGRAM WITH FRONTAL AND LATERAL CEPHALOMETRIC RADIOGRAPHS -PART 1. COMPUTATION OF THE THREE-DIMENSIONAL COORDINATES BY COMPENSATION OF THE ERROR OF THE HEAD POSITION IN ORDINARY NON-BIPLANAR CEPHALOSTAT- (정모 및 측모 두부 방사선 규격사진을 이용한 3차원 계측 프로그램의 개발 -1. 단일 방사선원으로 촬영된 두부 방사선사진의 두부 위치 보정을 이용한 3차원 좌표의 산출-)

  • Lee, Geun-Ho;Lee, Sang-Han;Jang, Hyon-Joong;Kwon, Tae-Geon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.3
    • /
    • pp.214-220
    • /
    • 2001
  • The clinical application of the three-dimensional radiographic technique had been limited to standard Broadbent-Bolton cephalometer with biplanar stereoradiography. We developed a new method for compensating the error of head position in ordinary non-biplanar cephalostat. It became to possible to use the three dimensional cephalogram commonly in clinical bases. 1. The method of methemetical compensation of head positioning error in non-biplanar condition was evaluated with dry skull. The error of the method of first and the second trial was $0.46{\pm}1.21$, $0.33{\pm}0.90mm$, which means the error of the head positioning correction in conventional cephalogram was within clinical acceptance. 2. The reproducibility of this system for clinical application was 0.54 mm ($-2.99{\sim}2.26mm$) which defines the absolute mean difference of the first and second trial. Compare to the The landmark identification error $1.2{\pm}1.6mm$, the error of the measurement was within the range of landmark identification error. The result indicates the adequate clinical accuracy of the computation of three-dimensional coordinates by compensation of the error of the head position in ordinary non-biplanar cephalostat.

  • PDF

Leakage noise detection using a multi-channel sensor module based on acoustic intensity (음향 인텐시티 기반 다채널 센서 모듈을 이용한 배관 누설 소음 탐지)

  • Hyeonbin Ryoo;Jung-Han Woo;Yun-Ho Seo;Sang-Ryul Kim
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.4
    • /
    • pp.414-421
    • /
    • 2024
  • In this paper, we design and verify a system that can detect piping leakage noise in an environment with significant reverberation and reflection using a multi-channel acoustic sensor module as a technology to prevent major plant accidents caused by leakage. Four-channel microphones arranged in a tetrahedron are designed as a single sensor module to measure three-dimensional sound intensity vectors. In an environment with large effects of reverberation and reflection, the measurement error of each sensor module increases on average, so after placing multiple sensor modules in the field, measurement results showing locations with large errors due to effects such as reflection are excluded. Using the intersection between three-dimensional vectors obtained from several pairs of sensor modules, the coordinates where the sound source is located are estimated, and outliers (e.g., positions estimated to be outside the site, positions estimated to be far from the average position) are detected and excluded among the points. For achieving aforementioned goal, an excluding algorithm by deciding the outliers among the estimated positions was proposed. By visualizing the estimated location coordinates of the leakage sound on the site drawing within 1 second, we construct and verify a system that can detect the location of the leakage sound in real time and enable immediate response. This study is expected to contribute to improving accident response capabilities and ensuring safety in large plants.