• Title/Summary/Keyword: 3-Dimensional Measurement

Search Result 1,256, Processing Time 0.03 seconds

A Study on the Measurement of the Breast Shape on Living Body by Using a PMP Moire Method (가슴형상 측정을 위한 PMP Moire 방법 활용)

  • Lee, Ga-Na;Yuk, Keun-Cheol;Kim, Byeong-Mee
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.11 no.2
    • /
    • pp.11-21
    • /
    • 2009
  • Recently, as custom-made demand about female underwear is increased, securing of a various dimension system is urgent, and satisfaction of each customer cannot be heightened with established dimensions. If we could measure shape of a living body with a fast and simple method, the custom-made demand of customers could be satisfied in the underwear as well as a clothing industry by using the method. One of the alternatives is shape measurement of the living body by a Moire fringe method. If we put a grating in front of an object to be measured and illuminate light, a Moire fringe with contour line shape is generated in the object, so we can conveniently measure object shape without touching directly by using the pattern. The Moire fringe and three-dimensional shape of the breast of the living body was acquired by a PMP method using a polygon mirror, and height and bottom width of the breast of the living body were measured by using obtained data in this study. Data of breast shape measurement through a mannequin was collected in a previous step as basic material for measuring the breast shape measurement of the living body. Three women in the twenties were selected as one of methods for measuring breast shape of a woman. As a result of the breast shape measurement of a living body A, it was measured that height of the breast was about 67.24mm and the bottom width was $13781.60mm^2$. This study is expected to contribute for collecting basic data of a female underwear industry and establishing a specification of a dimension system.

  • PDF

Methodology for Measuring the Quality of Three-Dimensional Television (3차원 텔레비전의 품질측정 방법론)

  • Byun, Dae-Ho
    • Journal of Digital Convergence
    • /
    • v.10 no.4
    • /
    • pp.1-9
    • /
    • 2012
  • Emerging three-dimensional television (3DTV) as a new IT product shows a possibility that television is not for just watching broadcasting, but an attractive tool for applying it to our real life. Three dimensional television is generally more effective and attractive than two-dimensional television (2DTV). But it still needs continuous technological improvement to solve its inherent limitations until many customers decide to purchase 3DTVs without hesitation. Innovative products like 3DTV encounter a quality problem leading purchase decision by customers. Quality is regarded as one of the most important factors affecting customers to adopt and use the product. Furthermore, measuring quality effectively is considerable for the 3DTV research. In this paper, we suggest the Analytic Hierarchy Process(AHP) method for evaluating 3DTVs in a view of quality. We describe quality criteria affecting the 3DTV selection through a literature survey and develope an analytical method for measuring quality. We classify the quality of 3DTV into four types and suggest a concept of the quality ratio as a measurement criteria instead of the quality gap. Though a numerical example, we show how priorities of 3DTV with versatile manufacturers is computed.

A Study on a Pattern Design for Pleated Skirts Based on the Amount of Waist Darts by Somatotype (체형별 허리 다트량을 활용한 플리츠 스커트 원형 설계에 관한 연구)

  • Lee, Jung-Hwa;Maruta, Naomi;Hirokawa, Taeko
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.35 no.8
    • /
    • pp.933-945
    • /
    • 2011
  • This research proposes a pattern design method for 24 pleated skirts in order to develop an automatic draft program for pleated skirts that will enhance fit and enable mass production. The research method and results are outlined as follow. 1. Three-dimensional body measurements were conducted on 30 randomly selected women in their 20s. By using 34 body measurement items and 6 types of calculations among the items, the items required in the designing of an original pleated skirt were extracted. They were then interpreted through correlation analysis, variance analysis, a t-test, linear regression analysis and multiple regression analysis. 2. An extra amount was added to the waist measurement and external capsule measurement according to the number of times the pleats coincided and the thickness of the fabric by the degree of polymerization of the horizontal cross section (the test of this research: 0.518mm). The extra amount of waist measurement was 3.6cm while the hip measurement was 4.3cm larger than the hip measurement combined with the external capsule measurement and the extra amount. 3. Based on the ${\pm}$standard deviation/2 as the average of the difference between the external capsule measurement and waist measurement, the subjects were classified into 3 somatotypes. Somatotype 1 presented an average total length of waist darts of 23.6cm while that of somatotype 2 was 26.2cm and that of somatotype 3 was 30.2cm. It has been confirmed that there is a significant difference among somatotypes in the total length of waist darts from the front center to the front side and the total length of waist darts from the side to the back center in terms of the average amount of waist darts for every 12 parts on the WL.

Application of GIS Technique for Fire Drill in Hillside Area

  • Chung Yeong-Jin
    • Spatial Information Research
    • /
    • v.12 no.4 s.31
    • /
    • pp.321-328
    • /
    • 2004
  • The purpose of this study is to describe 3-Dimensional technique to obtain spatial information automatically using PhotoModeler Pro. PhotoModeler Pro is excellent software with the three-dimensional measurement function used by a personal computer using Windows operating system However, it is not sufficient to carry out the automatic matching work with two stereo images. This is very large neck as a 3-D measurement software. In this study, the automatic stereo matching work using the self-making program and DDE interface within PhotoModeler Pro was tried. The experiment field is the hillside and stair zone of Tateyama region, Nagasaki City. The results of automatic stereo matching work were very good with $100\%$ hitting ratio of target.

  • PDF

Quantitative evaluating method for diagnostic ultrasound probe using 3-dimensional acoustic field analysis (3차원 음장 분석법을 이용한 진단용 초음파 프로브의 정량적 성능평가)

  • Noh, Si-Cheol;Kim, Ju-Young;Park, Jae-Hyun;Kim, Jin-Su;Kang, Jung-Hoon;Choi, Heung-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.490-496
    • /
    • 2010
  • In this study, in order to overcome the weakness of acoustic field analysis which is generally used for ultrasonic probe performance evaluation, automatic acoustic field measurement system and evaluation parameters were proposed. The comparisons between acoustic field simulation and measured acoustic distribution data of normal and abnormal channels were conducted to evaluate the availability of proposed system and evaluation parameters. First, the impulse response characteristic of sample probe was investigated to classify the normal elements and abnormal elements. And then, normal channels and abnormal channels with abnormal element were chosen. The suggested 12 evaluation parameters were calculated using the acoustic fields of these channels. The availability of proposed automatic acoustic field measurement system and evaluation parameters was confirmed. And the performance evaluation of ultrasonic probe using acoustic field analysis could be easier and faster.

Roughness Measurement of Hole Processing Surface for Mold Steel Using White Light Interferometer (백색광간섭계를 이용한 금형용 강재 구멍가공면의 조도 측정)

  • Lee, Seung-Chul;Kim, Kyeong-Suk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.1
    • /
    • pp.73-79
    • /
    • 2013
  • In this study, NIMAX material has been processed using the three-dimensional measuring instrument and white light interferometer. they were tested to roundness and surface roughness and results are as follows: As for a cutting characteristic, it indicated that F4 showed a lower result than 2F showed due to the high hardness of the material and showed a good result when spindle rotation speed and tool feed were low. As for the measurement of roundness through 3-Dimensional measuring machine, it indicated that 4F showed a good result like the condition of cutting component and that roundness showed a good result when spindle rotation speed of 1,700 rpm and tool feed speed of 85 mm/min were applied. As for the surface roughness of processing surface, Surface roughness showed better 4F than 2F and conditions of spindle rotation speed 1,700 rpm, tool feed rate 55 mm/min showed good results in the Ra $0.4025{\mu}m$.

Performance Test on 2-Dimensional PIV and 3-Dimensional PIV Using Standard Images (표준영상을 이용한 2차원 PIV와 3차원 PIV 성능시험)

  • Hwang, Tae-Gyu;Doh, Deog-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.11
    • /
    • pp.1315-1321
    • /
    • 2004
  • Quantitative performance test on the conventional 2D-PIV and the hybrid angular 3D-PIV(Stereoscopic PIV) was carried out. LES Data sets on an impinging jet which are provided on the webpage(http://www.vsj.or.jp/piv) for the PIV Standard Project were used for the generation of virtual images. The generated virtual images were used for the 2D-PIV and 3D-PIV measurements test. It has been shown that the results obtained by 2D-PIV on average values are slightly closer to the LES data than those obtained by 3D-PIV, but the turbulent properties obtained by 2D-PIV are largely underestimated than those obtained by 3D-PIV.

One Idea on a Three Dimensional Measuring System Using Light Intensity Modulation

  • Fujimoto Ikumatsu;Cho In-Ho;Pak Jeong-Hyeon;Pyoun Young-Sik
    • International Journal of Control, Automation, and Systems
    • /
    • v.3 no.1
    • /
    • pp.130-136
    • /
    • 2005
  • A new optical digitizing system for determining the position of a cursor in three dimensions(3D) and an experimental device for its measurement are presented. A semi-passive system using light intensity modulation, a technology that is well known in radar ranging, is employed in order to overcome precision limitations imposed by background light. This system consists of a charge-coupled device camera placed before a rotating mirror and a light-emitting diode whose intensity is modulated. Using a Fresnel pattern for light modulation, it is verified that a substantial improvement of the signal to noise ratio is realized for the background noise and that a resolution of less than a single pixel can be achieved. This opens the doorway to the realization of high precision 3D digitized measurement. We further propose that a 3D position measurement with a monocular optical system can be realized by a numerical experiment if a linear-period modulated waveform is adopted as the light-modulating one.

Three-dimensional Capsular Volume Measurements in Multidirectional Shoulder Instability

  • Jun, Yong Cheol;Moon, Young Lae;Elsayed, Moustafa I.;Lim, Jae Hwan;Cha, Dong Hyuk
    • Clinics in Shoulder and Elbow
    • /
    • v.21 no.3
    • /
    • pp.134-137
    • /
    • 2018
  • Background: In a previous study undertaken to quantify capsular volume in rotator cuff interval or axillary pouch, significant differences were found between controls and patients with instability. However, the results obtained were derived from two-dimensional cross sectional areas. In our study, we sought correlation between three-dimensional (3D) capsular volumes, as measured by magnetic resonance arthrography (MRA), and multidirectional instability (MDI) of the shoulder. Methods: The MRAs of 21 patients with MDI of the shoulder and 16 control cases with no instability were retrospectively reviewed. Capsular areas determined by MRA were translated into 3D volumes using 3D software Mimics ver. 16 (Materilise, Leuven, Belgium), and glenoid surface area was measured in axial and coronal MRA views. Then, the ratio between capsular volume and glenoid surface area was calculated, and evaluated with control group. Results: The ratio between 3D capsular volume and glenoid surface area was significantly increased in the MDI group ($3.59{\pm}0.83cm^3/cm^2$) compared to the control group ($2.53{\pm}0.62cm^3/cm^2$) (p<0.01). Conclusions: From these results, we could support that capsular volume enlargement play an important role in MDI of the shoulder using volume measurement.

Three-Dimensional Shape Measurement of a Specular Object by LED Array Reflection (LED Array의 반사영상에 의한 경면체의 3차원 형상 측정)

  • Kim, Jee Hong
    • Korean Journal of Optics and Photonics
    • /
    • v.27 no.1
    • /
    • pp.41-46
    • /
    • 2016
  • An optical method to measure the three-dimensional (3D) shape of a surface with specular reflection is proposed. The proposed method is based on the analysis of the geometric path of the light from a point source, and the relative displacements of points in the reflection image. The 3D shape of a concave mirror is shown to be determined approximately via experiments, where the vision system consists of LED array illumination, a half-mirror, and an imaging sensor.