• Title/Summary/Keyword: 3-D source distribution

Search Result 177, Processing Time 0.029 seconds

REBCO coil operation in gaseous helium and solid nitrogen

  • Diev, D.N.;Makarenko, M.N.;Naumov, A.V.;Polyakov, A.V.;Shcherbakov, V.I.;Shutova, D.I.;Surin, M.I.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.21 no.3
    • /
    • pp.47-50
    • /
    • 2019
  • The paper gives the results of the experiments with a model two-section REBCO solenoid cooled by either gaseous helium (GHe) or sub-cooled/solid nitrogen (SN2) in (50-77) K temperature range. The major cooling source was a single-stage cryocooler Sumitomo CH-110 with the cooling power of 175 W and 130 W at 77 K and 50 K respectively. The coil itself was not directly conduction cooled. We compare the time taken by both coolants to obtain the temperature of the magnet of about 50 K and the homogeneity of the temperature distribution within the cryostat. Test results for the coil operation in solid nitrogen together with the comparison of its critical properties in SN2 and GHe are also presented.

Monte Carlo Simulation of Irradiation Treatment of Peaches (Prunus persica L. Batsch) (몬테카를로 시뮬레이션을 이용한 복숭아의 방사선 조사)

  • Kim, Jongsoon;Kim, Dong-Hyun;Park, Jong-Min;Choi, Won-Sik;Kwon, Soon Hong
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.21 no.6
    • /
    • pp.337-344
    • /
    • 2018
  • Food irradiation is important not only in ensuring safety but also improving antioxidant activity of peaches. Our objective was to establish the best irradiation treatment for peaches by calculating dose distribution using Monte Carlo simulation. 3-D geometry and component densities of peaches, extracted from CT scan, were entered into MCNP to obtain simulated dose distribution. Radiation energies for electron beam were 1.35 MeV (low energy) and 10 MeV (high energy). Co (1.25 MeV) and the Husman irradiator, containing three sealed Cs source rods in an annular array, were used for gamma irradiation. At 1.35 MeV electron beam simulation, electrons penetrated well beyond the peach skin, enough for surface treatment for microorganisms and allergens. At 10 MeV electron beam simulation, for top-beam only treatment, doses at the core were the highest and for double beam treatment, the electron energy was absorbed by the entire sample. At Co source, the radiation doses were presented on the whole area. At Cs source, the dose uniformity ratios were 2.78 for one source and 1.48 for three ones at 120 degrees interval. Proper control of irradiation treatment is critical to establish confidence in the irradiation process.

Determination of Focused Control Pollutant Source by Analysis of Pollutant Delivery Characteristics in Unit Watershed Upper Paldang Lake (팔당호 상류의 단위유역별 오염물질 유출특성 분석을 통한 중점관리 오염원 선정)

  • Kim, Dong Woo;Jang, Mi Jeong;Han, Ihn Sup
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.5
    • /
    • pp.367-377
    • /
    • 2014
  • Paldang lake which is the most important water resource in Korea is classified as a stream type reservoir and water quality of Paldang lake can be significantly influenced by external pollutant source. So this study was aimed to determine focused control BOD and TP sources of each unit watershed upper Paldang lake through analysis of pollutant source distribution and pollutant runoff characteristics. Generated load, discharge load, delivery load and each load density of 11 unit watersheds upper Paldang lake were calculated using data of water quality and flow rate from pollutant sources and 74 small streams. As a result of generated load, discharge load and delivery load of BOD and TP from pollutant sources, the most BOD generated load was taken by livestock with 66% of total BOD discharge load and domestic had the most BOD discharge load, 42.7%. The ratio of delivery load of livestock and domestic was 36.4% and 34.3%, respectively. Livestock occupied high ratio of TP generated load, discharge load and delivery load with 82.5%, 44.4% and 46.7%, respectively. Gyeongan watershed which had high population density showed the highest BOD delivery load density of $14.6kg/km^2/d$ and the highest TP delivery load density with $1.23kg/km^2/d$ was analyzed in Cheongmi watershed including the biggest number of livestock. From these results, management of domestic sewer and livestock excrement was determined as a focused control pollutant source. And intensive management about domestic sewer in Gyeongan stream and livestock excrement in Cheongmi stream is required for water quality improvement of Paldang lake.

Performance Analysis of Tri-gate FinFET for Different Fin Shape and Source/Drain Structures (Tri-gate FinFET의 fin 및 소스/드레인 구조 변화에 따른 소자 성능 분석)

  • Choe, SeongSik;Kwon, Kee-Won;Kim, SoYoung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.7
    • /
    • pp.71-81
    • /
    • 2014
  • In this paper, the performance variations of tri-gate FinFET are analyzed for different fin shapes and source/drain epitaxy types using a 3D device simulator(Sentaurus). If the fin shape changes from a rectangular shape to a triangular shape, the threshold voltage increases due to a non-uniform potential distribution, the off-current decreases by 72.23%, and the gate capacitance decreases by 16.01%. In order to analyze the device performance change from the structural change of the source/drain epitaxy, we compared the grown on the fin (grown-on-fin) structure and grown after the fin etch (etched-fin) structure. 3-stage ring oscillator was simulated using Sentaurus mixed-mode, and the energy-delay products are derived for the different fin and source/drain shapes. The FinFET device with triangular-shaped fin with etched-fin source/drain type shows the minimum the ring oscillator delay and energy-delay product.

An analytical study on the Effect of High impedance Transformer to reduce Distribution Fault Current (변압기 임피던스 증가에 의한 배전계통의 고장전류 저감방안의 영향분석)

  • Lee, Hyun-Chul;Lee, Geun-Joon;Hyun, Ok-Bae;Hwang, Si-Dol
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.239_240
    • /
    • 2009
  • This paper presents the brief analytical study on 돋 effects of higher impedance transformer(HIT) to reduce distribution system fault current. With the increase of source and load capacity of power system, fault current of D/L is much more increased and, conventional protection equipment-such as sectionalizer and recloser, have to be replaced higher switching capacity. However, this replacements needs a lot of budget to utility. Increase of transformer impedance is can be a countermeasure in practical basis. This paper compares the voltage and fault current magnitude of both cases -%Zt=20% and %Zt2=33.3%(transformer capacity is 75/100MVA). The simulation results show that the steady state voltage of HIT is dropped 5~6% more in peak load, and fault current was decreased about 5kA by high impedance on transformer.

  • PDF

Over Current Protection Schemes for Active Filters with Series Compensators

  • Lee, Woo-Cheol;Lee, Taeck-Kie
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.4B no.3
    • /
    • pp.134-145
    • /
    • 2004
  • This paper presents and analyses protection schemes for a series active compensator, which consists of a Unified Power Quality Conditioner (UPQC) or a hybrid active power filter. The proposed series active compensator operates as a high impedance "k(D)" for the fundamental components of the power frequency during over current conditions in the distribution system. Two control strategies are proposed in this paper. The first strategy detects the fundamental source current using the p-q theory. The second strategy detects the fundamental component of the load current in the Synchronous Reference Frame (SRF). When over currents occur in the power distribution system momentarily, the proposed schemes protect the series active compensator without the need for additional protection circuits, and achieves excellent transient response. The validity of the proposed protection schemes is investigated through simulation and compared with experimental results using a hybrid active power filter systems.

The multigroup library processing method for coupled neutron and photon heating calculation of fast reactor

  • Teng Zhang;Xubo Ma;Kui Hu;GuanQun Jia
    • Nuclear Engineering and Technology
    • /
    • v.56 no.4
    • /
    • pp.1204-1212
    • /
    • 2024
  • To accurately calculate the heating distribution of the fast reactor, a neutron-photon library in MATXS format named Knight-B7.1-1968n × 94γ was processed based on the ENDF/B-VII.1 library for ultrafine groups. The neutron cross-section processing code MGGC2.0 was used to generate few-group neutron cross sections in ISOTXS format. Additionally, the self-developed photon cross-section processing code NGAMMA was utilized to generate photon libraries for neutron-photon coupled heating calculations, including photo-atom cross sections for the ISOTXS format, prompt photon production cross sections, and kinetic energy release in materials (KERMA) factors for neutrons and photons, and the self-shielding effect from the capture and fission cross sections of neutron to photon have been taken into account when the photon source generated by neutron is calculated. The interface code GSORCAL was developed to generate the photon source distribution and interface with the DIF3D code to calculate the neutron-photon coupling heating distribution of the fast reactor core. The neutron-photon coupled heating calculation route was verified using the ZPPR-9 benchmark and the RBEC-M benchmark, and the results of the coupled heating calculations were analyzed in comparison with those obtained from the Monte Carlo code MCNP. The calculations show that the library was accurately processed, and the results of the fast reactor neutron-photon coupled heating calculations agree well with those obtained from MCNP.

An Epidemiological Study for on Outbreak of Typhoid Fever in Busan Area (부산 일부지역에 유행한 장티푸스 환자에 대한 역학적인 조사)

  • Park, Chin-Hyung
    • Journal of Preventive Medicine and Public Health
    • /
    • v.10 no.1
    • /
    • pp.86-93
    • /
    • 1977
  • An epidemiological study was conducted, from April 28 to June 3, 1975, to investigate source and course of infection of typhoid fever occurred in Munhyeon Dong, Nam Gu, Busan. The obtained results were as follows: 1. The entity of unknown febrile disease was identified as Salmonella typhi, D group and it's symptoms were abdominal pain, diarrhea, hepatomegaly, nausea and vomiting, aplenomegaly, rose spots, tenderness of ileocecal region etc., in that order. 2. The average duration from onset to recovery was 25.2 days and incidence rate was 39.5 per 1,000 population. 3. The source of infection was presumed a charity patient. 4. By the duration of report on the cases from onset, 10-19 days group was the highest. 5. The positive rate of initial stool culture was 38.9% and secondary was 5.6%. 6. Distribution of the cases by age and sex showed that 5-9 years old group was the highest as 30.5%, and male was higher than female. 7. Distribution of the cases by education level, under primary school as 66.6% was the highest. By the living standard, the highest was low income earner group as 77.8%. 8. Utilization rate of medical facilites was drug store (41.7%), herbal drug (8.3%), clinic (5.6%) in that order.

  • PDF

Time Domain Analysis of the Motions of Catenary Moored Floating Breakwater (케터너리 제류 부유식 방파제 거동의 시간영성 해석)

  • 전인식
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.5 no.3
    • /
    • pp.182-190
    • /
    • 1993
  • A numerical technique is presented to calculate the motions of 6 d.o.f and mooring tensions for a catenary moored floating breakwater. The breakwater may be subjected to the 3-D combination of regular or irregular waves and stationary forces. The added mass coefficients at the infinitive frequency of input wave and the variations of damping and exciting force coefficients are calculated using the source distribution method. The coefficients are used to constitute motion equations in time domain which are solved by WiIson-$\theta$ method. The solutions agree quite well with either static displacement determined from Newton method under the stationary force only or 6 d.o.f determined from the frequency domain analysis under regular wave only. An example analysis is also done for a floating breakwater to demonstrate its applicability.

  • PDF

A Study on the Problems of the Neutral Line Due to the 3rd Harmonic (중성선 공용시 3배수 고조파에 따른 문제점 분석)

  • Cho, Nam-Hun;Jung, Jum-Soo;Park, Yong-Woo;Ha, Bok-Nam;Lee, Heung-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.10
    • /
    • pp.76-83
    • /
    • 2008
  • The neutral current is made of both the load unbalanced current and the 3rd harmonic. The 3rd harmonic which is the source of the main neutral current is generated from the loads using bridge rectifier circuits on their input produce currents. TV, computer and monitor which are belong to IEC 61000-3-2 Class D are the main 3rd harmonic current sources. In order to show the affect of the distribution system by these disturbances, this paper has studied the current standards of the Korea Electric and considers the problem of the neutral common.