• Title/Summary/Keyword: 3-D imaging display

Search Result 182, Processing Time 0.029 seconds

Development of the HDTV Camera and Monitor for Stereoscopic 3D Display

  • Kim, Nam;Kwon, Ki-Chul;Park, Jae-Hyeung
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1033-1036
    • /
    • 2008
  • In this paper, we describe the development of the polarized-light stereoscopic monitoring system based on full HDTV. The system consists of the stereoscopic camera part, image processing device for the stereoscopic image recording and stereoscopic display. The developed stereoscopic imaging display system reduces eyestrain and viewer fatigue.

  • PDF

High resolution 3D display using time-multiplexed overlapped projection

  • Baasantseren, Ganbat;Park, Jae-Hyeung;Kim, Nam
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.1338-1340
    • /
    • 2009
  • High resolution three-dimensional integral imaging display is proposed. Each time-multiplexed image is projected with different incident angle on same array of elemental lenses. Those images are collected at different positions in focal plane of lens array, and thus the number of the point light sources increases and their spacing decreases. Therefore, proposed method can create high resolution 3D images.

  • PDF

Elemental image resizing and the analysis of the reconstructed three dimensional image in the integral imaging system (집적결상법에서 기본영상의 크기 변환에 따른 3차원 재생영상의 특성 분석)

  • Ser, Jang-Il;Shin, Seung-Ho
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.3
    • /
    • pp.225-234
    • /
    • 2005
  • In the integral imaging system for 3D display, the elemental image size is closely related to the several variables, such as the size of elemental lens, the distance between elemental lens and elemental image, etc., on the pick up system. We have analyzed the geometric relation between the variables. In addition, we have investigated the integrated image variation for the individual and whole conversion of the size of the elemental images, different from in pick up process, and presented experimental results.

Analysis of the depth limitation for curved lens array system based on integral imaging

  • Kim, Yun-Hee;Park, Jae-Hyeung;Lee, Byoung-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1595-1598
    • /
    • 2005
  • Integral imaging attracts much attention as an autostereoscopic three-dimensional (3D) display technique for its many advantages. Recently the method that uses a curved lens array with a curved screen has been reported to overcome the limitation of viewing angle in integral imaging. This method widens the viewing angle remarkably. However, to understand the proposed system we need to know how the depth is limited in the proposed method also. We analyze the depth limitation and show the simulation results.

  • PDF

360-degree Viewable Cylindrical Integral Imaging System Using Electroluminescent Films

  • Jung, Jae-Hyun;Park, Gil-Bae;Kim, Yun-Hee;Lee, Byoung-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.1254-1257
    • /
    • 2009
  • A 360-degree viewable three-dimensional display based on integral imaging is proposed. The cylindrically arranged point light source array which is generated by electroluminescent (EL) pinhole film reconstructs 360-degree viewable virtual 3D image at the center of the cylinder. In this paper, the principle of operation and experimental results are presented.

  • PDF

360-degree Viewable Cylindrical Integral Imaging System Using Electroluminescent Films

  • Jung, Jae-Hyun;Park, Gil-Bae;Kim, Yun-Hee;Lee, Byoung-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.1330-1333
    • /
    • 2009
  • A 360-degree viewable three-dimensional display based on integral imaging is proposed. The cylindrically arranged point light source array which is generated by electroluminescent (EL) pinhole film reconstructs 360-degree viewable virtual 3D image at the center of the cylinder. In this paper, the principle of operation and experimental results are presented.

  • PDF

Multi-Detector Row CT of the Central Airway Disease (Multi-Detector Row CT를 이용한 중심부 기도 질환의 평가)

  • Kang, Eun-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.55 no.3
    • /
    • pp.239-249
    • /
    • 2003
  • Multi-detector row CT (MDCT) provides faster speed, longer coverage in conjunction with thin slices, improved spatial resolution, and ability to produce high quality muliplanar and three-dimensional (3D) images. MDCT has revolutionized the non-invasive evaluation of the central airways. Simultaneous display of axial, multiplanar, and 3D images raises precision and accuracy of the radiologic diagnosis of central airway disease. This article introduces central airway imaging with MDCT emphasizing on the emerging role of multiplanar and 3D reconstruction.

Visual quality enhancement of three-dimensional photon-counting integral imaging using background noise removal algorithm (배경 잡음 제거 알고리즘을 적용한 3차원 광자 계수 집적 영상의 화질 향상)

  • Cho, Ki-Ok;Kim, Young jun;Kim, Cheolsu;Cho, Myungjin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.7
    • /
    • pp.1376-1382
    • /
    • 2016
  • In this paper, we present a visual quality enhancement technique for conventional three-dimensional (3D) photon counting integral imaging using background noise removal algorithm. Photon counting imaging can detect a few photons from desired objects and visualize them under severely photon-starved conditions such as low light level environment. However, when a lot of photons are generated from background, it is difficult to detect photons from desired objects. Thus, the visual quality of the reconstructed image may be degraded. Therefore, in this paper, we propose a new photon counting imaging method that removes unnecessary background noise and detects photons from only desired objects. In addition, integral imaging can be used to obtain 3D information and visualize the 3D image by statistical estimations such as maximum likelihood estimation. To prove and evaluate our proposed method, we implement the optical experiment and calculate mean square error.

Integral Imaging Pickup Method of Bio-Medical Data using GPU and Octree (GPU와 옥트리를 이용한 바이오 메디컬 데이터의 집적 영상 픽업 기법)

  • Jang, Young-Hee;Park, Chan;Jung, Ji-Sung;Park, Jae-Hyeung;Kim, Nam;Ha, Jung-Sung;Yoo, Kwan-Hee
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.6
    • /
    • pp.1-9
    • /
    • 2010
  • Recently, 3D stereoscopic display such as 3D stereoscopic cinemas and 3D stereoscopic TV is getting a lot of interest. In general, a stereo image can be used in 3D stereoscopic display. In other hands, for 3D auto stereoscopic display, the elemental images should be generated through visualization from every camera in a lens array. Since a lens array consists of several cameras, it takes a lot of time to generate the elemental images with respect to 3D virtual space, specially, if a large bio-medical volume data is in the 3D virtual space, it will take more time. In order to improve the problem, in this paper, we construct an octree for a given bio-medical volume data and then propose a method to generate the elemental images through efficient rendering of the Octree data using GPU. Experimental results show that the proposed method can obtain more improvement comparable than conventional one, but the development of more efficient method is required.

Optimum parameters of 3D integral imaging system (3차원 집적 영상 시스템의 최적 파라미터)

  • Cho, Myungjin;Lee, Byonggook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.10a
    • /
    • pp.1019-1022
    • /
    • 2012
  • Integral imaging is a promising technology for 3D imaging and display. Many parameters affect the performance of 3D integral imaging systems. Enhanced system performance is acquired by optimization of these system parameters with respect to defined performance metrics. In this paper, we present an approach to optimize the performance of 3D integral imaging system in terms of performance metrics under fixed resource constraints. In this analysis, system parameters such as lens numerical aperture, pitch between image sensors, the number of image sensors, the pixel size, and the number of pixels are determined to optimize performance metrics. Wave optics is utilized to describe the imaging process.

  • PDF