• Title/Summary/Keyword: 3-D CT image

Search Result 433, Processing Time 0.03 seconds

Evaluation of marginal leakage of bulk fill flowable composite resin filling with different curing time using micro-computed tomography technology (Bulk fill 유동성 복합레진의 변연 누출에서 다른 중합시간의 영향에 대해 마이크로시티를 이용한 평가)

  • Kim, Eun-Ji;Lee, Kyu-Bok;Jin, Myoung-Uk
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.3
    • /
    • pp.184-193
    • /
    • 2016
  • Purpose: To evaluate marginal leakage of bulk fill flowable composite resin filling with different curing time by using microcomputed tomography technology. Materials and Methods: 30 previously extracted human molars were randomly divided into 6 groups based upon restorative system and different curing time. Class II cavities (vertical slot cavities) were prepared. An individual metallic matrix was used to build up the proximal wall. The SonicFill or SureFil SDR flow was inserted into the preparation by using 1 bulk increment, followed by light polymerization for different curing times. The different exposure times were 20, 40, and 60 seconds. All specimens were submitted to 5,000 thermal cycles for artificial aging. Micro-CT scanning was performed by using SkyScan 1272. One evaluator assessed microleakage of silver nitrated solution at the resin-dentin interface. The 3D image of each leakage around the restoration was reconstructed with CT-Analyser V.1.14.4. The leakage was analyzed with the Mann-Whitney test. Results: Significant differences were observed between the light curing times, but no significant differences were found between the bulk fill composite resins. Increasing in the photoactivation time resulted in greater microleakage in all the experimental groups. Those subjected to 60 seconds of light curing showed higher microleakage means than those exposed for 20 seconds and 40 seconds. Conclusion: Increasing the photoactivation time is factor that may increase marginal microlekage of the bulk fill composite resins. Further, micro-CT can nondestructively detect leakage around the resin composite restoration in three dimensions.

Hepatic Vessel Segmentation using Edge Detection (Edge Detection을 이용한 간 혈관 추출)

  • Seo, Jeong-Joo;Park, Jong-Won
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.3
    • /
    • pp.51-57
    • /
    • 2012
  • Hepatic vessel tree is the key structure for hepatic disease diagnosis and liver surgery planning. Especially, it is used to evaluate the donors' and recipients' liver for the LDLT(Living Donors Liver Transplantation) and estimate the volumes of left and right hepatic lobes for securing their life in the LDLT. In this study, we propose a method to apply canny edge detection that is not affected by noise to the liver images for automatic segmentation of hepatic vessels tree in contrast abdominal MDCT image. Using histograms and average pixel values of the various liver CT images, optimized parameters of the Canny algorithm are determined. It is more time-efficient to use the common parameters than to change parameters manually according to CT images. Candidates of hepatic vessels are extracted by threshold filtering around the detected the vessel edge. Finally, using a system which detects the true-negatives and the false-positives in horizontal and vertical direction, the true-negatives are added in candidate of hepatic vessels and the false-positives are removed. As a result of the process, the various hepatic vessel trees of patients are accurately reconstructed in 3D.

The Effect of Anteromedial Tibial Cortex Angle on Change of Posterior Tibial Slope Angle in PTO(Proximal Tibial Osteotomy) using Computer Assisted Surgery(CAS) (Computer Assisted Surgery(CAS)를 이용한 개방형 쐐기 근위경골 절골술에서 전내측 경골피질경사각이 후방경골경사각의 변화에 미치는 영향)

  • Lee, Ho-Sang;Kim, Cheol-Woong;Bae, Ji-Hoon;Wang, Joon-Ho;Park, Jong-Woong;Oh, Dong-Joon
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1467-1470
    • /
    • 2008
  • An upper tibial opening wedge osteotomy is an operation to cure a malalignment and a degenerate arthritis. To prevent the postoperative malalignment caused by the upper tibial opening wedge osteotomy, the research to define the relationship between a Hinge Axis Angle and a Posterior Slope Angle is needed. The effect of the relationship between the hinge axis angle and the gap angle on the posterior slope angle is studied. After 3-D Compute Tomography (CT) scanning image is reconstructed, the virtual surgery is performed by the reconstructed 3-D tibia model. It was proved that the relationship between the hinge axis angle and the gap angle were constant and the simple mathematical model could be derived. To verify the suggested mathematical model, it compared with the measured data from the virtual surgery. In conclusion, while the deviation between the data from the virtual surgery and ones of the mathematical model under the gap angle<$10^{\circ}$ was less than 1%.

  • PDF

Surgical stent for dental implant using cone beam CT images (콘빔형 전산화단층영상을 이용한 치과임플란트 식립유도장치 개발)

  • Choi, Hyung-Soo;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.40 no.4
    • /
    • pp.171-178
    • /
    • 2010
  • Purpose : The purpose of this study is to develop a surgical stent for dental implant procedure that can be easily applied and affordable by using cone beam computerized tomography (CBCT). Materials and Methods : Aluminum, Teflon-PFA (perfluoroalkoxy), and acetal (polyoxymethylene plastic) were selected as materials for the surgical stent. Among these three materials, the appropriate material was chosen using the CBCT images. The surgical stent, which could be easily placed into an oral cavity, was designed with chosen material. CBCT images of the new surgical stent on mandible were obtained using Alphard-3030 dental CT system (Asahi Roentgen Co., Ltd., Kyoto, Japan). The point of insertion was prescribed on the surgical stent with the multiplanar reconstruction software of OnDemand3D (CyberMed Inc., Seoul, Korea). Guide holes were made at the point of insertion on the surgical stent using newly designed guide jig. CBCT scans was taken for the second time to verify the accuracy of the newly designed surgical stent. Results : Teflon-PFA showed radiologically excellent image characteristics for the surgical stent. High accuracy and reproducibility of implantation were confirmed with the surgical stent. Conclusion : The newly designed surgical stent can lead to the accurate implantation and achieve the clinically predictable result.

Finite element modeling technique for predicting mechanical behaviors on mandible bone during mastication

  • Kim, Hee-Sun;Park, Jae-Yong;Kim, Na-Eun;Shin, Yeong-Soo;Park, Ji-Man;Chun, Youn-Sic
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.4
    • /
    • pp.218-226
    • /
    • 2012
  • PURPOSE. The purpose of this study was to propose finite element (FE) modeling methods for predicting stress distributions on teeth and mandible under chewing action. MATERIALS AND METHODS. For FE model generation, CT images of skull were translated into 3D FE models, and static analysis was performed considering linear material behaviors and nonlinear geometrical effect. To find out proper boundary and loading conditions, parametric studies were performed with various areas and directions of restraints and loading. The loading directions are prescribed to be same as direction of masseter muscle, which was referred from anatomy chart and CT image. From the analysis, strain and stress distributions of teeth and mandible were obtained and compared with experimental data for model validation. RESULTS. As a result of FE analysis, the optimized boundary condition was chosen such that 8 teeth were fixed in all directions and condyloid process was fixed in all directions except for forward and backward directions. Also, fixing a part of mandible in a lateral direction, where medial pterygoid muscle was attached, gave the more proper analytical results. Loading was prescribed in a same direction as masseter muscle. The tendency of strain distributions between the teeth predicted from the proposed model were compared with experimental results and showed good agreements. CONCLUSION. This study proposes cost efficient FE modeling method for predicting stress distributions on teeth and mandible under chewing action. The proposed modeling method is validated with experimental data and can further be used to evaluate structural safety of dental prosthesis.

Performance Evaluation of Radiochromic Films and Dosimetry CheckTM for Patient-specific QA in Helical Tomotherapy (나선형 토모테라피 방사선치료의 환자별 품질관리를 위한 라디오크로믹 필름 및 Dosimetry CheckTM의 성능평가)

  • Park, Su Yeon;Chae, Moon Ki;Lim, Jun Teak;Kwon, Dong Yeol;Kim, Hak Joon;Chung, Eun Ah;Kim, Jong Sik
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.93-109
    • /
    • 2020
  • Purpose: The radiochromic film (Gafchromic EBT3, Ashland Advanced Materials, USA) and 3-dimensional analysis system dosimetry checkTM (DC, MathResolutions, USA) were evaluated for patient-specific quality assurance (QA) of helical tomotherapy. Materials and Methods: Depending on the tumors' positions, three types of targets, which are the abdominal tumor (130.6㎤), retroperitoneal tumor (849.0㎤), and the whole abdominal metastasis tumor (3131.0㎤) applied to the humanoid phantom (Anderson Rando Phantom, USA). We established a total of 12 comparative treatment plans by the four geometric conditions of the beam irradiation, which are the different field widths (FW) of 2.5-cm, 5.0-cm, and pitches of 0.287, 0.43. Ionization measurements (1D) with EBT3 by inserting the cheese phantom (2D) were compared to DC measurements of the 3D dose reconstruction on CT images from beam fluence log information. For the clinical feasibility evaluation of the DC, dose reconstruction has been performed using the same cheese phantom with the EBT3 method. Recalculated dose distributions revealed the dose error information during the actual irradiation on the same CT images quantitatively compared to the treatment plan. The Thread effect, which might appear in the Helical Tomotherapy, was analyzed by ripple amplitude (%). We also performed gamma index analysis (DD: 3mm/ DTA: 3%, pass threshold limit: 95%) for pattern check of the dose distribution. Results: Ripple amplitude measurement resulted in the highest average of 23.1% in the peritoneum tumor. In the radiochromic film analysis, the absolute dose was on average 0.9±0.4%, and gamma index analysis was on average 96.4±2.2% (Passing rate: >95%), which could be limited to the large target sizes such as the whole abdominal metastasis tumor. In the DC analysis with the humanoid phantom for FW of 5.0-cm, the three regions' average was 91.8±6.4% in the 2D and 3D plan. The three planes (axial, coronal, and sagittal) and dose profile could be analyzed with the entire peritoneum tumor and the whole abdominal metastasis target, with planned dose distributions. The dose errors based on the dose-volume histogram in the DC evaluations increased depending on FW and pitch. Conclusion: The DC method could implement a dose error analysis on the 3D patient image data by the measured beam fluence log information only without any dosimetry tools for patient-specific quality assurance. Also, there may be no limit to apply for the tumor location and size; therefore, the DC could be useful in patient-specific QAl during the treatment of Helical Tomotherapy of large and irregular tumors.

A Study on the Angle between the Abdominal Aorta and the Superior Mesenteric Artery by 3D Image Reconstruction (3D 영상 재구성을 통한 복부대동맥과 상장간막동맥과의 각도에 관한 연구)

  • Kim, Young-Keun;Choi, Sung-Kwan
    • Journal of radiological science and technology
    • /
    • v.26 no.1
    • /
    • pp.63-70
    • /
    • 2003
  • SMAS(Superior Mesenteric Artery Syndrome) is a disease caused by a chronic obstruction of the duodenum(transverse portion), which is hardly detectable. However, it is known that when the superior mesenteric artery and abdominal aorta form a narrow angle, that the transverse portion of the duodenum is pressed down between the superior mesenteric artery and the abdominal aorta, and that this can lead to obstruction of the duodenum. Measuring this angle is a complicated job using conventional angiography, and results often turns out to be inaccurate. In addition, no attempt has been made to determine the value of this angle in Koreans. In this study, we conducted abdominal CT angiography using MIP(maximum intensity projection) on patients with no clinical evidence of SMAS in order to determine the angle at which the superior mesenteric artery branches from the abdominal aorta by using PC based software(Rapidia ver. 1.2) for the image reconstruction. Accordingly, we found that the mean angle between the abdominal aorta and the superior mesenteric artery was $50.05{\pm}15.87^{\circ}$ on average, and that the angle in men($53.64{\pm}16.57^{\circ}$) is higher than in women($46.46{\pm}14.98^{\circ}$). We hope that the angles determined by our study will serve as an important indicator for detecting SMAS.

  • PDF

Signal Change of Iodinated Contrast Agents in MR Imaging (요오드화 조영제가 MR영상에 미치는 신호 변화)

  • Jeong, HK;Kim, Seongho;Kang, Chunghwan;Lee, Suho;Yi, Yun;Kim, Mingi;Kim, Hochul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.12
    • /
    • pp.131-138
    • /
    • 2016
  • In this study, we tried to analyze the influence of ICM(Iodinated Contrast Media) in MR imaging compare to GBCA(Gadolinium Based Contrast Agent), and as this result we discussed whether resonable or not the protocol which is MRI scan after enhanced CT scan without proper time interval in clinical field. For this research, we assembled two phantoms. which one was iodine and another one was gadolinium. We did test two phantoms in conventional MRI scan which is T1, T2, T2 FLAIR and 3D angio. After that, quantitative analysis was progressed. The results of study were as follow : SSI(Saline's Signal Intensity) was shown as each sequences 175, 1231, 333, 37 [a.u] at iodine. and 1297, 123, 757, 232 [a.u] was recorded at gadolinium. BDEPS(the Biggest Difference of EPS) was shown as each sequences 1297, 123, 757, 232 [a.u] at iodine and 793, 6, 1495, 365 [a.u] was recorded at gadolinium. At this time, EPS(Enhancement Percentage to Saline) was shown 641.1, -90.0, 127.3, 527% at iodine and 685.1, 99.4, 365.7, 1077.4% was recorded at gadolinium. BP(BDEPS's point) was shown 900, 900, 477, 900 mmol at iodine and 4, 0.2, 0.2, 40 mmol was recorded at gadolinium. CPSS(Change Point of SI to SSI) was shown 63, 423, 63, 29 mmol at iodine and each [50, 30], [4, 0.2], [4, 1], 0.2 mmol was recorded at gadolinium. According to this research, we could not only discover the fact that was iodine could effect on MR signal, but also the pattern is different as various sequences compare to gadolinium. Therefore, we expect useful diagnostic MR image in clinical field with this quantitative data for deciding protocol regarding MRI and CT scan order.

Development and application of stent-based image guided navigation system for oral and maxillofacial surgery (구강외과 수술용 스텐트 기반 영상유도 수술 시스템의 개발)

  • Lee, Woo-Jin;Kim, Dae-Seung;Yi, Won-Jin;Lee, Sam-Sun;Choi, Soon-Chul;Heo, Min-Suk;Huh, Kyung-Hoe;Kim, Myung-Jin;Lee, Jee-Ho
    • Imaging Science in Dentistry
    • /
    • v.39 no.3
    • /
    • pp.149-156
    • /
    • 2009
  • Purpose : The purpose of this study was to develop a stent-based image guided surgery system and to apply it to oral and maxillofacial surgeries for anatomically complex sites. Materials and Methods : We devised a patient-specific stent for patient-to-image registration and navigation. Three-dimensional positions of the reference probe and the tool probe were tracked by an optical camera system and the relative position of the handpiece drill tip to the reference probe was monitored continuously on the monitor of a PC. Using 8 landmarks for measuring accuracy, the spatial discrepancy between CT image coordinate and physical coordinate was calculated for testing the normality. Results : The accuracy over 8 anatomical landmarks showed an overall mean of $0.56{\pm}0.16\;mm$. The developed system was applied to a surgery for a vertical alveolar bone augmentation in right mandibular posterior area and possible interior alveolar nerve injury case of an impacted third molar. The developed system provided continuous monitoring of invisible anatomical structures during operation and 3D information for operation sites. The clinical challenge showed sufficient accuracy and availability of anatomically complex operation sites. Conclusion : The developed system showed sufficient accuracy and availability in oral and maxillofacial surgeries for anatomically complex sites.

  • PDF

THE CLINICAL STUDY FOR AVAILABLE VOLUME OF ANTERIOR PART OF ASCENDING RAMUS AS A DONOR SITE IN ORAL AND MAXILLOFACIAL REGION (공여부로서의 하악 상행지 전방부의 가용 용적에 관한 임상적 연구)

  • Jung, Sung-Uk;Lee, Eui-Seok;Yun, Jung-Ju;Lee, Sung-Jae;Jang, Hyun-Seok;Kwon, Jong-Jin;Rim, Jae-Suk
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.31 no.2
    • /
    • pp.130-136
    • /
    • 2005
  • Bone grafts are widely used in the reconstruction of osseous defects in the oral and maxillofacial region. Autogenous bone grafts are considered the gold standard in grafting of the oral and maxillofacial region, because of its osteoconductive and osteoinductive properties. Mandibular symphysis & ascending ramus bone graft have been used more frequently because of easy surgical access, reduced operative time, and following minimal morbidity. However, even though the frequent use of the anterior part of ascending ramus and the different regions of mandible, rare of the reports provide information about the quantity of bone available in this donor site. So this study was taken to evaluate & quantify the amount of bone graft material in the anterior ascending ramus regions. This study was made on 36 samples of CT image. In 3D volume image, imaginary osteotomy & segmentation were done and the dimensions and volume of the bone grafts were measured and evaluated. the average volume of the graft materials obtained from the ascending ramus was $3656.83{\pm}108.19mm^3$, and the average dimensions of graft materials were $(33.68{\pm}0.48){\times}(34.92{\pm}0.51){\times}(15.96{\pm}0.27){\times}(9.05{\pm}0.27)mm$.