A Generalized Calorie Estimation Algorithm Using 3-Axis Accelerometer

  • Choi, Jee-Hyun;Lee, Jeong-Whan;Shin, Kun-Soo
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.6
    • /
    • pp.301-309
    • /
    • 2006
  • The main purpose of this study is to derive a regression equation that predicts the individual differences in activity energy expenditure (AEE) using accelerometer during different types of activity. Two subject groups were recruited separately in time: One is a homogeneous group of 94 healthy young adults with age ranged from $20\sim35$ yrs. The other subject group has a broad spectrum of physical characteristics in terms of age and fat ratio. 226 adolescents and adults of age ranged from $12\sim57$ yrs and fat ratio from $4.1\sim39.7%$ were in the second group. The wireless 3-axis accelerometers were developed and carefully fixed at the waist belt level. Simultaneously the total calorie expenditure was measured by gas analyzer. Each subject performed walking and running at speeds of 1.5, 3.0, 4.5, 6.0, 6.5, 7.5, and 8.5 km/hr. A generalized sensor-independent regression equation for AEE was derived. The regression equation was developed fur walking and running. The regression coefficients were predicted as functions of physical factors-age, gender, height, and weight with multivariable regression analysis. The generalized calorie estimation equation predicts AEE with correlation coefficient of 0.96 and the average accuracy of the accumulated calorie was $89.6{\pm}7.9%$.

Vibration Control of a Knee Joint considering Human Vibration of the Biped Walking RGO for a Trainning of Rehabilitation(II) (척수마비환자 재활훈련용 보행보조기의 인체진동을 고려한 무릎관절 시스템 진동제어 (II))

  • Kim, Myung-Hoe;Yang, Hyun-Seok;Baek, Yun-Soo;Park, Young-Pil;Park, Chang-Il
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.347.2-347
    • /
    • 2002
  • This paper presented a design and a Vibration control of a biped walking RGO(Robotic Gait Orthosis) and walking simulation by this system. The vibration evaluation of the Knee Joint Mechanism on the biped walking RGO(Robotic Galt Orthosis) was used to access by the 3-axis accelerometer with a low frequency vibration for the spinal cord injuries. It will be expect that the spinal cord injury patients are able to recover effectively by a biped walking RGO. (omitted)

  • PDF

Development of u-Healthcare Agent System using of 3-Axis Accelerometer Sensor (3축 가속도 센서를 이용한 u-헬스케어 에이전트 시스템 개발)

  • Choi, Dong-Oun;Kim, Jin-Sung;Song, Haeng-Sook
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.4
    • /
    • pp.98-105
    • /
    • 2010
  • Health of the people involved in blood sugar, blood pressure, activity, and using bio-sensors to obtain biometric information, the system for monitoring health research for development is a lot. This paper analyzes the bio information by monitoring the u-health care agent system was developed. Activity measurement technology that uses 3-axis accelerometer sensor. 3-axis acceleration sensors, using information obtained from activity to activity analysis to calculate the exact algorithm was developed. More accurate than the existing system to calculate the calorie consumption, it is stored in the database management. and you can check your health status using of activity and bio-information.

User Authentication Using Accelerometer Sensor in Wrist-Type Wearable Device (손목 착용형 웨어러블 기기의 가속도 센서를 사용한 사용자 인증)

  • Kim, Yong Kwang;Moon, Jong Sub
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.6 no.2
    • /
    • pp.67-74
    • /
    • 2017
  • This paper proposes a method of user authentication through the patterns of arm movement with a wrist-type wearable device. Using the accelerometer sensor which is built in the device, the 3-axis accelerometer data are collected. Then, the collected data are integrated and the periodic cycle are extracted. In the cycle, the features of frequency are generated with the accelerometer. With the frequency features, 2D Gaussian mixture are modelled. For authenticating an user, the data(the accelerometer) of the user at some point are tested with confidence interval of the Gaussian distribution. The model showed a valuable results for the user authentication with an example, which is average 92% accuracy with 95% confidence interval.

COS MEMS System Design with Embedded Technology (Embedded 기술을 이용한 COS MEMS 시스템 설계)

  • Hong, Seon Hack;Lee, Seong June;Park, Hyo Jun
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.4
    • /
    • pp.405-411
    • /
    • 2020
  • In this paper, we designed the COS MEMS system for sensing the falling detection and explosive noise of fuse link in COS (Cut Out Switch) installing on the power distribution. This system analyzed the failure characteristics and an instantaneous breakdown of power distribution. Therefore, our system strengths the industrial competence and guaranties the stable power supply. In this paper, we applied BLE (Bluetooth Low Energy) technology which is suitable protocol for low data rate, low power consumption and low-cost sensor applications. We experimented with LSM6DSOX which is system-in-module featuring 3 axis digital accelerometer and gyroscope boosting in high-performance mode and enabling always-on low-power features for an optimal motion for the COS fuse holder. Also, we used the MP34DT05-A for gathering an ultra-compact, low power, omnidirectional, digital MEMS microphone built with a capacitive sensing element and an IC interface. The proposed COS MEMS system is developed based on nRF52 SoC (System on Chip), and contained a 3-axis digital accelerometer, a digital microphone, and a SD card. In this paper of experiment steps, we analyzed the performance of COS MEMS system with gathering the accelerometer raw data and the PDM (Pulse Data Modulation) data of MEMS microphone for broadcasting the failure of COS status.

Exercise Recognition using Accelerometer Based Body-Attached Platform (가속도 센서 기반의 신체 부착형 플랫폼을 이용한 운동 인식)

  • Kim, Joo-Hyung;Lee, Jeong-Eom;Park, Yong-Chan;Kim, Dae-Hwan;Park, Gwi-Tae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.11
    • /
    • pp.2275-2280
    • /
    • 2009
  • u-Healthcare service is one of attractive applications in ubiquitous environment. In this paper, we propose a method to recognize exercises using a new accelerometer based body-attached platform for supporting u-Healthcare service. The platform consists of a device for measuring accelerometer data and a device for receiving the data. The former measures a user's motion data using a 3-axis accelerometer. The latter transmits the accelerometer data to a computer for recognizing the user's exercise. The algorithm for exercise recognition classifies the type of exercise using principle components analysis(PCA) from the accelerometer data transformed by discrete fourier transform(DFT), and estimates the repetition count of the recognized exercise using a peak detection algorithm. We evaluate the performance of the algorithm from the accuracy of the recognition of exercise type and the error rate of the estimation of repetition count. In our experimental result, the algorithm shows the accuracy about 98%.

An Introduction of Myo Armband and Its Comparison with Motion Capture Systems

  • Cho, Junghun;Lee, Jang Hyung;Kim, Kwang Gi
    • Journal of Multimedia Information System
    • /
    • v.5 no.2
    • /
    • pp.115-120
    • /
    • 2018
  • Recently, ways for accurately measuring the three dimensional movements of hand are actively researched so as to utilize the measurement data for therapeutic and rehabilitation programs. This research paper aims to introduce a product called Myo Armband, a wearable device comprised of a 3-axis accelerometer, a 3 axis gyroscope, and electromyographic sensors. We compare Armband's performance with that of the Motion Capture System, which is known as a device for providing fairly accurate measurements for angular movements of objects. Dart throwing and wrist winding motions comprised movement scenarios. This paper also discusses one of Armband's advantages - portability, and suggests its potential as a substitute for previously used devices. Decent levels of measurement accuracy were obtained which were comparable to that of three dimensional measurement device.

Efficiency Test for Low Electric Power Type and MEMS Based 3-axis Accelerometer (저전력 MEMS 기반 3축 가속도계의 성능 시험)

  • Lee, Byeung-Leul;Lee, Seung-Jae;Moon, Dae-Joong;Jung, Jin-Woo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.1
    • /
    • pp.160-165
    • /
    • 2014
  • In this study, an efficiency test was performed by fabricating MEMS (Micro Electro Mechanical Systems) based 3-axis acceleration sensor modules and an earthquake monitoring system was composed. Data acquisition device (NI-9239) with a 24bit ADC (Analog to Digital Converter) was used for improving the performance of 3-axis acceleration sensor modules and filtered data (100Hz Low Pass Filter) was used for reducing noises. Also this paper focused on detecting meaningful vibration in the building by developing the earthquake monitoring software. If vector sum of 3-axis acceleration is greater than the preset value, the value will be recorded and saved to the file.

Optimal Design of a Convective MEMS Accelerometer (열대류형 초소형 가속도계의 최적 설계)

  • Park, Byoung-Kyoo;Kim, Joon-Won;Moon, Il-Kwon;Kim, Dong-Sik
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1951-1956
    • /
    • 2008
  • Various MEMS accelerometers are used in engineering applications including automobiles, mobile phones, military systems, and electronic devices. Among them, the thermal accelerometer employing the temperature difference induced by the convective flow inside the micro cavity has been a topic of interest. As the convective sensor does not utilize a solid proof mass, it is compact, lightweight, inexpensive to manufacture, sensitive and highly endurable to mechanical shock. However, the complexity of the convective flow and various design constraints make optimization of a device a crucial step before fabrication. In this work, optimization of a 2-axis thermal convective MEMS accelerometer is conducted based on 3-dimensional numerical simulation. Parametric studies are performed by varying the several design variables such as the heater shape/size, the cavity size and types of the gas medium and the position of temperature probes in the sensor. The results of optimal design are presented.

  • PDF

Design of a Low Noise 6-Axis Inertial Sensor IC for Mobile Devices (모바일용 저잡음 6축 관성센서 IC의 설계)

  • Kim, Chang Hyun;Chung, Jong-Moon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.2
    • /
    • pp.397-407
    • /
    • 2015
  • In this paper, we designed 1 chip IC for 3-axis gyroscope and 3-axis accelerometer used for various IoT/M2M mobile devices such as smartphone, wearable device and etc. We especially focused on analysis of gyroscope noise and proposed new architecture for removing various noise generated by gyroscope MEMS and IC. Gyroscope, accelerometer and geo-magnetic sensors are usually used to detect user motion or to estimate moving distance, direction and relative position. It is very important element to designing a low noise IC because very small amount of noise may be accumulated and affect the estimated position or direction. We made a mathematical model of a gyroscope sensor, analyzed the frequency characteristics of MEMS and circuit, designed a low noise, compact and low power 1 chip 6-axis inertial sensor IC including 3-axis gyroscope and 3-axis accelerometer. As a result, designed IC has 0.01dps/${\sqrt{Hz}}$ of gyroscope sensor noise density.