• Title/Summary/Keyword: 3 inch

Search Result 553, Processing Time 0.024 seconds

Effects of Al-doping on IZO Thin Film for Transparent TFT

  • Bang, J.H.;Jung, J.H.;Song, P.K.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.207-207
    • /
    • 2011
  • Amorphous transparent oxide semiconductors (a-TOS) have been widely studied for many optoelectronic devices such as AM-OLED (active-matrix organic light emitting diodes). Recently, Nomura et al. demonstrated high performance amorphous IGZO (In-Ga-Zn-O) TFTs.1 Despite the amorphous structure, due to the conduction band minimum (CBM) that made of spherically extended s-orbitals of the constituent metals, an a-IGZO TFT shows high mobility.2,3 But IGZO films contain high cost rare metals. Therefore, we need to investigate the alternatives. Because Aluminum has a high bond enthalpy with oxygen atom and Alumina has a high lattice energy, we try to replace Gallium with Aluminum that is high reserve low cost material. In this study, we focused on the electrical properties of IZO:Al thin films as a channel layer of TFTs. IZO:Al were deposited on unheated non-alkali glass substrates (5 cm ${\times}$ 5 cm) by magnetron co-sputtering system with two cathodes equipped with IZO target and Al target, respectively. The sintered ceramic IZO disc (3 inch ${\phi}$, 5 mm t) and metal Al target (3 inch ${\phi}$, 5 mm t) are used for deposition. The O2 gas was used as the reactive gas to control carrier concentration and mobility. Deposition was carried out under various sputtering conditions to investigate the effect of sputtering process on the characteristics of IZO:Al thin films. Correlation between sputtering factors and electronic properties of the film will be discussed in detail.

  • PDF

HISTOLOGIC CHANGES IN MANDIBULAR PERIODONTIUM OF THE MONKEY FOLLOWING EXPERIMENTAL EXTRUSION OF ANTERIOR TEETH (실험적 전치 정출시 원숭이 하악 치주 조직의 변화)

  • Lee, Sung-Youn;Kim, Tae-Woo;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.25 no.4
    • /
    • pp.403-414
    • /
    • 1995
  • The purpose of this study was to investigate the histologic changes in mandibular periodontium during overbite closure for openbite treatment by continuous arch wires and anterior vertical elastics. Two female monkey(Macaca nemestrina) with permanent dentition were used. Posterior bite block was fixed to each of their maxillae, which made the animal temporary anterior openbite as well as stabilized the whole maxillary anchorage. In each mandible, all the teeth except the second molars which had been extracted, were prepared for cast crowns. 018 inch Standard brackets were welded on these crowns. After cementation, two types of the $016{\times}022$ inch continuous arch wires, the plain ideal arch to the control animal and the MEAW(multiloop edgewise archwire) to the other experimental one were inserted. Then anterior vertical elastics were applied for two weeks. The overbite depth changes in the monkeys and histologic examinations of the mandibular periodontiums suggested the following conclusions. 1. During two weeks of the experimental period, the overbite increased + 0.3 mm in the control and + 1.3 mm in the experimental one. 2. In both the control and the experimental animal, histologic examinations showed that incisors, canines and first premolars were subject to extrusive force and the rest of posteriors were subject to intrusive one. 3. In periodontiums of the extruded incisors of the experimental one, reorientation of the periodontal fiber structures reflected the direction of force and the alveolar bone surfaces including apical and crestal areas which had been subject to tension, were the front of new bone formation. 4. In periodontiums of the extruded incisors of the experimental one, neither excessive hyalinization nor gross root resorption was observed. 5. Alveolar bone remodeling of anteriors and posteriors was more remarkable in the experimental one than the control.

  • PDF

The Study on Estimating Life Cycle of 2.5 Inch Hard disk base on PC using enviroment (PC 사용 환경에 기반한 2.5 인치 하드 디스크의 수명주기 예측에 대한 연구)

  • Cho, Euy-Hyun;Park, Jeong-Kyu;Lee, Min-Woo;Kwon, Soon-Mu
    • Journal of Digital Contents Society
    • /
    • v.15 no.2
    • /
    • pp.301-308
    • /
    • 2014
  • The mass storage of data and the importance of storage capacity lately has emerged. In this paper, we suggest the new method which estimate life cycle from acceleration life test about 2.5 inch hard disk driver as mass storage, which minimize the difference between real market annual failure rate and estimated failure rate. we obtain market transfer capacity per hours from returned 2.5inch hard disk drives about 309 numbers and accelerating transfer capacity per hours from acceleration life test. we calculate acceleration factor about duty cycle and estimate annual failure rate from failure rate and acceleration factors: temperature acceleration factor, duty cycle acceleration factor, the transfer capacity per hour represent the 93.4 % of user is 5.8 GB/hour, the transfer capacity per hour from acceleration life test is 81.4 GB/hour. the acceleration factor of duty cycle is 14.1. annual failure rate is stabilized at market one year after, annual failure rate is between 0.3 and 0.378. estimated annual failure rate is 0.4, so it is matched at 75~94 % between estimate annual failure rate and market annual failure rate. This study influence the estimate method of annual failure rate by the result of acceleration life cycle of manufacture.

Hydraulic Experiments on the Measuring Equipments of Ronoff and Soil Loss (유출수 및 유실토량 측정장치에 관한 수리시험)

  • 유한열
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.10 no.1
    • /
    • pp.1377-1387
    • /
    • 1968
  • In order to measure runoff and soil losses produced in a small test plot during rainfall, it is usually insufficient to use a tank only, necessitating the combined use of a main tank and a subsidiary tank. Accordingly. exact measurement largely depends on how to connect those two measuring tanks. The main purpose of this thesis is to improve the connecting parts of two measuring tanks so as to assure exact measurement of runoff and soil losses. In this experiment, two types of main tank, i. e. A-type and B-type, were used. A-type is a square tank having a flume at its end. At the flume, ten apertures are provided by using metal columns so as to be able to catch one tenth of total muddy flow discharging at the end of the flume, One tenth of total flow is led to the subsidiary tank through a slot sampler fixed to an aperture. B-type differes in that its flume does not have apertures and slot sampler is fixed directly to the end of the flume, other features being the same as those of A-type. Discharge volumes were measured by using weighing tanks and compared. The effect of baffle screen provided in the flume was also observed in connection with exact measurements. In order to keep main tank and its flume in a horizontal position, bolts and nuts mechanism was used. Vertical and horizontal screens were provided in the main to prevent coarse sands coming into the flume. The conclusion derived through this experiment is as follows: (1) The discharge through slot sampler at each aperture is almost the same for A-type. However, it is slightly more than one tenth of total discharge volume. (2) In case that baffle screen is provided in the flume of A-type tank, the discharge volume of slot sampler is less than that of the same type without screen. (3) For B-type tank, slot sampler discharge increases as slot sampler nears toward the center of flume. (4) When baffle screen is provided in the flume of B-type, slot sampler discharge is less than that of the same type without screen, and this phenomenon is more apparent as compared with A-type. (5) In case that the slot width of slot sampler for B-type is one inch, slot sampler discharge exceeds one tenth of total discharge volume. (6) When the slot width for B-type is 15/16 inch and slot sampler is fixed 3/8 inch apart from either flume wall, slot sampler discharge is approximately equal to one tenth of total discharge volume.

  • PDF

Design and Performance Evaluation of Small Size Counting and Imaging Gamma Probe System (소형 계수용 및 영상용 감마프로브 시스템의 설계와 성능평가)

  • Yang, Myo-Geun;Kwark, Cheol-Eun;Sim, yong-Geol;Kim, Hee-Joung;Choi, Yong;Chung, Jung-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.3
    • /
    • pp.291-299
    • /
    • 1997
  • As a microimaging device detecting gamma rays emitted from small lesions or tumors during operation, the intraoperative surgical probe has been proposed and is now under development. We have designed a multipurpose portable gamma prove system and evaluated the performance both for the absolute counting purpose of residual radioactivities and for the localizing capability of gamma events using the NaI(Tl) crystal and two types of photomultiplier tubes(PMTs). Counting efficiencies in the range of routine clinical use of radiation dose were measured using the assembly of single channel PMTs and 0.5 inch thick NaI(Tl) crystal of 1 inch diameter. The positioning of gamma events for imaging purpose requires the multiple channel PMTs with appropriate positioning electronics. We have designed a simple and reliable positioning circuit based on the concept of modified Anger. In preliminary experiments using the multiple channel PMT of 3 inch diameter and the dim lighth source, we were able to trace and localize the correct position with reduced positioning error by the use of two multiplier/divider chipset and simplified peripherals. The energy resolutions for the counting gamma probe measured as full width at half maximum(FWHM) for Cs-137, F-18, Tc-99m were 12%, 13%, and 36%, respectively. The spatial resolution for the imaging gamma probe measured as FWHM for green LED was 2.9 mm. The results indicate that the currently developing probe is very promising and could be very useful for many applications in nuclear medicine. Future studies will include developing collimators, improving interface hardwares, and evaluating the system with clinical data.

  • PDF

The Effect of Tributary Pipe Breaks on the Core Support Barrel Shell Responses (분기관파단이 노심지지배럴의 쉘응답에 미치는 영향)

  • Jhung, Myung-Jo;Hwan, Won-Gul
    • Nuclear Engineering and Technology
    • /
    • v.25 no.2
    • /
    • pp.204-214
    • /
    • 1993
  • Work on fracture mechanics has provided a technical basis for elimination of main coolant loop double ended guillotine breaks from the structural design basis of reactor coolant system. Without main coolant loop pipe breaks, the tributary pipe breaks must be considered as design bases until further fracture mechanics work could eliminate some of these breaks from design consideration. This paper determines the core support barrel shell responses for the 3 inch pressurizer spray line nozzle break which is expected to be the only inlet break remaining in the primary side after leak-before-break evaluation is extended to smaller size pipes in the near future. The responses are compared with those due to 14 inch safety injection nozzle break and main coolant loop pipe break. The results show that, when the leak-before-break concept is applied to the primary side piping systems with a diameter of 10 inches or over, the core support barrel shell responses due to pipe breaks in the primary side are negligible for the faulted condition design.

  • PDF

A COMPARATIVE STUDY ON THE FLEXIBILITY OF THE WROUGHT WIRE CLASPS (가공선 크라스프의 가요성에 관한 비교 연구)

  • Eom, Tae-Wan;Chang, Ik-Tae;Kim, Kwang-Nam
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.27 no.2
    • /
    • pp.261-270
    • /
    • 1989
  • Bend test is one of the methods comparing the physical properties of the clasp wires. The type of bend test used in this investigation was the cantilever loading of a wrought wire. The purpose of this study was to compare the flexibility of a number of commonly used clasp wires, in according to gauge, alloy and heat treatment, under specific condition of load and deflection. Seven noble and one base metal wires were tested under three conditions as follows: (1) as received, (2) quenched (placed in an over at $700^{\circ}C$ for ten minutes and immediately quenched in water at room temperature.), (3) oven cooled (quencned as described, then placed in an oven at $450^{\circ}C$ for two minutes and uniformly slowly cooled to $250^{\circ}C$ in thirty minutes.) The basic test specimen consists of a sample 25 mm in length and 19, 18 gauge in diameter (17 gauge also in two alloys), and the wire was loaded in the form of straight cantilever beams. Force at 0.25 mm (0.01 inch) and 0.5 mm (0.02 inch) deflections for all samples were recorded. The results were as follows ; 1. Ticonium was least flexible and No. 2 was most flexible in according to gauge, alloy and heat treatment. 2. In most of precious wrought wire, the flexibility was increased, but there was no statistically significant differences between as-received and softened condition. 3. There was no statistically differences between as-received and hardened condition. 4. For each alloy, there were statistically significant differences in flexibility due to clasp diameter.

  • PDF

The Study of Improvement of Measurement Precision on Bulk Density, Soil Hardness and Air Permeability in Upland Soils

  • Ok, Jung-hun;Han, Kyung-hwa;Cho, Hee-rae;Zhang, Yong-seon;Seo, Young-ho;Jung, Kang-ho;Lee, Hyub-sung;Kim, Gi-sun
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.50 no.5
    • /
    • pp.482-488
    • /
    • 2017
  • The measurement based on reliable standard operating procedures (SOPs) is important for consistent information. The objective of this study is to investigate reliable SOPs of soil physical methods, including core method for bulk density, Yamanaka hardness, and air permeameter method for air permeability. The coefficients of variation in bulk density (core method), Yamanaka hardness, and air permeability were ranged of 1~6%, 8~13%, and 10~84%, respectively. The variation in situ measurement such as bulk density, hardness, and air permeability due to spatial variability at measuring site was larger due to the number of replicates, organic matter content, and soil texture. Nevertheless, air permeability had different values as different number of replicates, and thus, it is thought that more replicates can result in higher reliability. It suggested that investigation of soil physical properties for the target sites should required to consider about soil texture, organic matter content, and number of replications before measurement. In conclusion, core sampling for bulk density measurement in upland soil recommended to perform in 3 repetitions with 2 inch core, and 3 inch core sampling for higher organic matter content.

PCB Board Impedance Analysis Using Similarity Transform for Transmission Matrix (전송선로행열에 대한 유사변환을 이용한 PCB기판 임피던스 해석)

  • Suh, Young-Suk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.10
    • /
    • pp.2052-2058
    • /
    • 2009
  • As the operating frequency of digital system increases and voltage swing decreases, an accurate and high speed analysis of PCB board becomes very important. Transmission matrix method, which use the multiple products of unit column matrix, is the highest speedy method in PCB board analysis. In this paper a new method to reduce the calculation time of PCB board impedances is proposed. First, in this method the eigenvalue and eigenvectors of the transmission matrix for unit column of PCB are calculated and the transmission matrix for the unit column is transformed using similarity transform to reduce the number of multiplication on the matrix elements. This method using the similarity transform can reduce the calculation time greatly comparing the previous method. The proposed method is applied to the 1.3 inch by 1.9 inch board and shows about 10 times reduction of calculation time. This method can be applied to the PCB design which needs a lots of repetitive calculation of board impedances.

Fabrication and Chracteristics of Cutting Cell with Various Laser Conditions (다양한 레이저 조건에 따른 컷팅셀 제작 및 특성 분석)

  • Park, Jeong Eun;Kim, Dong Sik;Choi, Won Seok;Jang, Jae Joon;Lim, Dong gun
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.3
    • /
    • pp.9-17
    • /
    • 2019
  • Laser cutting cell of solar cells can achieve high voltage and efficiency through more array than conventional 6 inch cell compared to same area. In this study, we fabricated c-Si cutting cell with various lasers and laser conditions such as power, speed, and number of times. In the case of picosecond laser, excellent surface characteristics were obtained due to small surface defects and low thermal damage at the output of 20W and the speed of 100 mm/s. However, it is not possible to fabricate a cutting cell having good characteristics due to nonuniform cutting inside the wafer when the processing for forming a cutting cell is not sufficiently performed. For nanosecond lasers, the best wafer characteristics were obtained for fabrication of excellent cutting cells at a frequency of 500 kHz and a laser speed of 100 mm/s. However, the nanosecond laser has not been processed sufficiently in the condition of a number of times. As a result, it was confirmed that the wafer thickness was cut by $63{\mu}m$ of the cell thickness of $170{\mu}m$ in the condition of five times of laser process. It was found that more than 30% of the wafer thickness had to be processed to fabricate the cutting cell. After cutting the 6-inch cell having the voltage of 0.65 V, we obtained the voltage of about 0.63 V.