• 제목/요약/키워드: 3 Valve-type Pulse Tube Refrigerator

검색결과 6건 처리시간 0.027초

3 밸브형 맥동관 냉동기의 작동 해석 (Analysis of the Operation of a 3 Valve-type Pulse Tube Refrigerator)

  • 송영식;조경철;정평석
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.335-340
    • /
    • 2000
  • A 3 valve-type pulse tube refrigerator optains its cooling effect from pressure drop by releasing the part of the charged gas through hot end nozzle. The objective of this study is to analyze the performance and to find an optimal expansion pressure of the 3 valve-type pulse tube refrigerator. It is assumed that gas lumps are not mixed and periodically repeat the adiabatic compression and expansion processes. And the nodal model is applied for the analysis of the regenerator. As the result of analysis, the optimum pressure at the end of expansion process was about 80-90% of the maximum pressure.

  • PDF

GM형 맥동관 냉동기의 저온부 경사도에 따른 냉각 성능 특성 연구 (Orientation dependence of GM-type pulse tube refrigerator)

  • 고준석;김효봉;박성제;홍용주;염한길;이청수;강인수;고득용
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제14권3호
    • /
    • pp.48-52
    • /
    • 2012
  • This paper describes experimental study on the orientation dependence of GM-type pulse tube refrigerator with helium and neon as working gas. A pulse tube refrigerator generates refrigeration work with gas expansion by gas displacer in the pulse tube. The pulse tube is only filled with working gas and there exists secondary flow due to large temperature difference between cold-end and warm-end. The stability of secondary flow is affected by orientation of cold-head and thus cooling performance is deteriorated by gas mixing due to secondary flow. In this study, a single stage GM-type pulse tube with orifice valve as a phase control device is fabricated and tested. The fabricated pulse tube refrigerator is tested with two different working gases of helium and neon. First, optimal valve opening and operating frequency are determined with experimental results of no-load test. And then, the variation of no-load temperature as orientation angle of cold-head is measured for two different working gases. Effect of orientation dependence of cold-head as working gas is discussed with experimental results.

Experimental research on 2 stage GM-type pulse tube refrigerator for cryopump

  • Park, Seong-Je;Ko, Jun-Seok;Hong, Yong-Ju;Kim, Hyo-Bong;Yeom, Han-Kil;Koh, Deuk-Yong
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제12권2호
    • /
    • pp.29-33
    • /
    • 2010
  • The experimental results of the 2 stage Gifford-McMahon(GM) type pulse tube refrigerator (PTR) or cryopump are presented in this paper. The objectives of his study are to develop design technology of the integral type 2 stage PTR which rotary valve is directly connected to he hot end of the regenerator and acquire its improved performance. Design of the 2 stage PTR is conducted by FZKPTR(Forschungs Zentrum Karlsruhe Pulse Tube Refrigerator) program for the design of pulse tube refrigerators. The fabricated PTR has U-type configuration and incorporates orifice valve, double-inlet valve and reservoir as phase control mechanism. Rotary valve is used to make pulsating pressure and is directly connected to inlet of $1^{st}$ stage regenerator. From experiments, cooling performance map and pressure waveform at each point were measured for different operating frequencies. Experimental results show the best cooling performance with 2 Hz operation in spite of small pressure amplitude. The lowest temperatures of the 2 stage PTR were 16.9 K at the second stage and 58.0 K at the first stage. The cooling capacities achieved were 14.4 W at 79 K, the first stage and 3.6 W at 29 K, the second stage.

Experimental Study on a GM-type Two-Stage Pulse Tube Refrigerator for Cryopump Applications

  • Lee, S.J.;Hong, Y.J.;Park, S.J.;Kim, H.B.;Kwon, S.B.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제9권2호
    • /
    • pp.35-38
    • /
    • 2007
  • A single-stage and two-stage pulse tube refrigerators have been designed for cryopump application. The different diameters of pulse tube and regenerator have been investigated at single-stage pulse tube refrigerator(PTR). Experiments have been performed on single-stage PTR to reach minimum temperature with optimum valve opening at a few frequencies. And the two-stage pulse tube refrigerators have been assembled with tested single-stage pulse tube and tested. When orifice turn is opened to 9 and double inlet is opened to 3 at a single-stage, the lowest temperature of 33.7 K is achieved. The cooling capacity at single-stage is 38 W at temperature of 80 K. A two-stage pulse tube refrigerator has 16.3K at the second stage and 59.7K at the first stage. The cooling capacity achieved is 16.5 W at 80 K, the first stage and 0.6 W at 20 K, the second stage. Some details on the design of pulse tube refrigerator and the experimental apparatus are given.

이중입구 맥동관냉동기의 수치적 해석 (Numerical Analysis of a Double Inlet Pulse Tube Refrigerator)

  • 채왕병;정은수;최헌오
    • 설비공학논문집
    • /
    • 제7권3호
    • /
    • pp.501-511
    • /
    • 1995
  • A numerical model for predicting the performance of gas distrubutor type double inlet pulse tube refrigerators has been developed. The model was based on adiabatic analysis and the losses of heat exchangers and regenerator were considered. Thermodynamic behavior of working fluid within a double inlet pulse tube refrigerator was investigated and the effects of design parameters, such as valve and orifice openings, cold heat exchanger temperature, frequency and pulse tube length, on the cooling capacity and COP were shown.

  • PDF

Performance test of 100 W linear compressor

  • Ko, J.;Koh, D.Y.;Park, S.J.;Kim, H.B.;Hong, Y.J.;Yeom, H.K.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권3호
    • /
    • pp.35-39
    • /
    • 2013
  • In this paper, we present test results of developed 100 W class linear compressor for Stirling-type pulse tube refrigerator. The fabricated linear compressor has dual-opposed configuration, free piston and moving magnet type linear motor. Power transfer, efficiency and required pressure waveform are predicted with designed and measured specifications. In experiments, room temperature test with flow impedance is conducted to evaluate performance of developed linear compressor. Flow impedance is loaded to compressor with metering valve for flow resistance, inertance tube for flow inertance and buffer volumes for flow compliance. Several operating parameters such as input voltage, current, piston displacement and pressure wave are measured for various operating frequency and fixed input current level. Behaviors of dynamics and performance of linear compressor as varying flow impedance are discussed with measured experimental results. The developed linear compressor shows 124 W of input power, 86 % of motor efficiency and 60 % of compressor efficiency at its resonant operating condition.