• Title/Summary/Keyword: 3 Story Building Structure

Search Result 177, Processing Time 0.059 seconds

A Study on the Change of Architecture Density and Residential Environment according to Reconstruction (재건축에 따른 건축밀도 및 주거환경의 변화 연구)

  • Kim, Hong-Bae
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.19 no.1
    • /
    • pp.35-42
    • /
    • 2017
  • This study aims to investigate the change in building density and residential environment after the reconstruction of decrepit public rental housing complexes formed in accordance with the Land Readjustment Project during the 1970s-80s. The results of this study can be summarized as follows: First, in terms of change in residential environment after the reconstruction, floor plans that were limited to two to four types and to small apartments measuring $42.9m^2$(13py)-$56.1m^2$ (17py) became varied, presenting 5-6 types of floor plans and various sizes of apartments. In particular, the reconstructed apartments were mainly built in a size smaller than 85($m^2$) and in the 3LDK floor plan and staircase-style unit architectural structure in order to reflect the lifestyle of residents. Second, in terms of change in building density after the reconstruction, the building coverage ratio did not change a lot, but the floor area ratio showed great change depending on the complex, ranging from a minimum of 2.9 times (Singdong Complex) to a maximum of 5.4 times (Eoyangdong Complex). Such change is attributable to the reconstruction policy that aims to improve the residential environment for original residents, secure economic feasibility and efficiency, and reflect the lifestyle of residents while incorporating dividends assigned to the existing housing project members as well as the maximum floor area ratio allowed by the regulation. Additionally, in terms of change in the number of floors and building density after the reconstruction, the former 5-story apartments were changed to apartments with 16-28 stories. Accordingly, the number of households in each complex has also increased by 20%. Third, according to the characteristics of parking facilities in terms of the size and density of parking spaces, former apartment complexes had only aboveground parking lots, not underground parking area. The newly constructed apartment complexes have underground parking space, and the parking-housing ratio is 1.1-1.3 cars.

Semi-Active Control System Based on the Experimental Results of the Performance of a Small Scale MR Damper (소형 MR감쇠기의 성능 실험에 기초한 준능동 제어 시스템)

  • Min Kyung-Won
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.19 no.3 s.73
    • /
    • pp.233-238
    • /
    • 2006
  • In this paper, mixed mode magneto-rheological(MR) damper, which is applicable for vibration control of a small scale multi-story structure, is devised. First, the schematic configurations of the shear, flow, and mixed mode MR dampers are described with design constraints and then the analytical models to predict the field-dependent damping forces are derived for each type. Second, an appropriate size of the mixed mode MR damper is manufactured and its field-dependent damping characteristics are evaluated in time domain. Finally, the performance of the manufactured MR damper which is semi-actively applied to a small scale building excited by earthquake load, is numerically evaluated.

Semismic Analysis of Building Structures with Base Isolation System (Base Isolation System이 있는 건물의 지진하중에 대한 동적해석)

  • 이동근;이정석
    • Computational Structural Engineering
    • /
    • v.3 no.1
    • /
    • pp.71-81
    • /
    • 1990
  • The isolation system is installed at the base of a structure for reduction of the earthquake damage to the structure. In the 1970', when the laminated rubber bearing(LR type) is developed, the isolation system is put in practice. And recently a new isolation system(SR type), including the laminated rubber bearing with the friction plate beneath, is developed. In this thesis, a study on the base isolation effect, for various of the isolation system and structure properties, is performed. The results of this parameter study show that the isolation system can reduce the earthquake damage of the building structures significantly. As the period of isolation system increases, the isolation effect increases and converges to zero damage. As the number of story increases, the isolation effect reduces. It is found that SR type isolation system is more effective than LR type because SR type base isolation system reduces acceleration, drift and total displacement.

  • PDF

Dynamic Response of Unreinforced Masonry Building (비보강 조적조의 동적 거동)

  • Kim, Nam-Hee;Kim, Jae-Kwan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.8 no.5 s.39
    • /
    • pp.1-14
    • /
    • 2004
  • The seismic behavior of a 1/3-scale model of a two-story unreinforced masonry (URM) structure typically used in constructing low-rise residential buildings in Korea is studied through a shaking table test. The purposes of this study are to investigate seismic behavior and damage patterns of the URM structure that was not engineered against seismic loading and to provide its experimental test results. The test structure was symmetric about the transverse axis but asymmetric to some degrees about longitudinal axis and had a relatively strong diaphragm of concrete slab. The test structure was subjected to a series of differentlevels of earthquake shakings that were applied along the longitudinal direction. The measured dynamic response of the test structure was analyzed in terms of various global parameters (i.e., floor accelerations, base shear, floor displacements and storydrift, and torsional displacements) and correlated with the input table motion. Moreover, different levels of seismic performance were suggested for performance-based design approach. The results of the shaking table test revealed that the shear failure was dominant on a weak side of the 1stfloor while the upper part of the test model remained as a rigid body. Also, it was found that substantial strength and deformation capacity existed after cracking.

Ecosystem Structure and Improvement of Naturalness in Urban Area -In the Case of Kangseo-gu in Seoul- (도시생태계 현황파악 및 자연성 증진 방안 -서울시 강서구를 사례로-)

  • 이수동;이경재
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.32 no.3
    • /
    • pp.1-17
    • /
    • 2004
  • The focus of this study is the promotion of green area volumes and their naturalness, water circulation system, decline of entropy, creation of biological habitats and linkage of separated urban green space. Re-presentative urban biotope survey sites were categorized as urban biotope, semi-natural biotope, and natural forest. In the urban biotope, a residential biotope was constructed near the Han river and in mountain areas. The green-area ratio at the housing complex was about 25%. GVZ(Grunvolumenzahl) was 0.35m$^3$/m$^2$ at the 5∼10-story housing complex, and 1.53m$^3$/m$^2$ over the 11-story. As for the green-area structure of the housing complex, canopy layer, understory layer, and shrub layer were not differentiated and the green-area volume was not high enough. The green-area ratio of school areas as a public area biotope was 5∼20%. GVZ was 1.12m$^3$/m$^2$ at Myungduk High School, and 1.78m$^3$/m$^2$ at Jeonggok Elementary School. In order to convert the urban biotope into an ecological area, green areas around the buildings should be connected to urban buffer green areas, and multi-layer structures should be established with natural plant species. In the semi-natural biotope, neighbor parks were created park in the vicinity of the natural forests. GVZ was 0.28m$^3$/m$^2$, and plantation was established with single layer structure and was definitely insufficient for the area. The urban buffer green areas have been established in strip corridors with the width of 20∼123m. In those areas, GVZ was 0.16∼0.27m$^3$/m$^2$ and had a deficient canopy layer, understory layer, and shrub layer. Soil conditions were not favorable for tree growth. In the natural biotope, GVZ of the plantation was 1.03∼1.5m$^3$/m$^2$ but the high crown closure of this area reduces the chance of species change and succession. GVZ of natural forest was 2.53∼2.57m$^3$/m$^2$. It is desirable to plant diverse plants and the natural forest should be succeeded by broad-leaf deciduous tree species. To improve the value of biotope at Kangseo-Gu, building height needs to be limited to reduce the environmental deterioration in the city. In order to maintain the water circulation system, water-permeable material is recommened when the urban surface areas are paved. The establishment of a water circulation system will improve ground water levels, soil moisture, water quality, and habitats. In order to improve biological diversity, it is desirable to have multi-layer structures in urban green areas with native species.

System identification of high-rise buildings using shear-bending model and ARX model: Experimental investigation

  • Fujita, Kohei;Ikeda, Ayumi;Shirono, Minami;Takewaki, Izuru
    • Earthquakes and Structures
    • /
    • v.8 no.4
    • /
    • pp.843-857
    • /
    • 2015
  • System identification is regarded as the most basic technique for structural health monitoring to evaluate structural integrity. Although many system identification techniques extracting mode information (e.g., mode frequency and mode shape) have been proposed so far, it is also desired to identify physical parameters (e.g., stiffness and damping). As for high-rise buildings subjected to long-period ground motions, system identification for evaluating only the shear stiffness based on a shear model does not seem to be an appropriate solution to the system identification problem due to the influence of overall bending response. In this paper, a system identification algorithm using a shear-bending model developed in the previous paper is revised to identify both shear and bending stiffnesses. In this algorithm, an ARX (Auto-Regressive eXogenous) model corresponding to the transfer function for interstory accelerations is applied for identifying physical parameters. For the experimental verification of the proposed system identification framework, vibration tests for a 3-story steel mini-structure are conducted. The test structure is specifically designed to measure horizontal accelerations including both shear and bending responses. In order to obtain reliable results, system identification theories for two different inputs are investigated; (a) base input motion by a modal shaker, (b) unknown forced input on the top floor.

Study on Flexural Strength of Wide Composite Beam for Long Span and Saving Story height (장스팬 및 층고저감형 와이드 복합보의 휨성능에 관한 연구)

  • Choi, Yun-Cheul;Park, Keum-Sung;Lee, Sang-Sup;Choi, Hyun-Ki
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.6
    • /
    • pp.44-51
    • /
    • 2017
  • Recently, the parking in downtown area has caused severe problem due to the dramatic increase of possessing automobile in the country. A parking structure has been on the spotlight to solve the parking problem in downtown area. However, the overall height of parking structure is stipulated less than 8 m. Therefore, in this research, 'wide composite beam', which is possible for reducing story height and having long span, is developed and the flexural capacity of the wide composite beam is evaluated. Based on the result of the flexural test, the flexural strength of wide composite beam increased by 20% as the thickness of steel beam increased by 3 mm ($6mm{\rightarrow}9mm$) The shapes of rebar (whether it is triangle or rectangular shape) in the wide composite beam did not affect its flexural strength. The flexural strength of wide composite beam without rebar decreased by 10% compared to that of wide composite beam with rebar. In addition, the neutral axis moved upward as a load increased, but the neutral axis moved downward, when the load exceeded a certain level of load.

Vibration Control of Structures Using Viscoelastic Dampers Installed in Expansion Joints (신축이음부에 설치된 점탄성감쇠를 이용한 구조물의 진동제어)

  • Kim, Jin-Koo;Ryou, Jin-Gook
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.8 no.4
    • /
    • pp.33-42
    • /
    • 2004
  • The usual practice of placing viscoelastic dampers (VED) in the inter-story of building structures frequently interfere with spatial planning and obstruct internal view. These shortcomings can be overcome by installing VED in seismic joints or in expansion joints which are usually hidden under a cover. This study investigates the effect of installing VED in seismic joints to reduce earthquake-induced dynamic reponses. Parametric studies were conducted using 3-DOF systems connected by VED and subjected to earthquake excitations to investigate the effectiveness of the proposed scheme. Nonlinear dynamic analyses were carried out with five-story structures composed of different structure systems and connected by seismic joints. According to the analysis results the use of VED in seismic joints turned out to be effective as long as the natural frequencies of the connected structures are different enough.

Experimental study on Chinese ancient timber-frame building by shaking table test

  • Zhang, Xi-Cheng;Xue, Jian-Yang;Zhao, Hong-Tie;Sui, Yan
    • Structural Engineering and Mechanics
    • /
    • v.40 no.4
    • /
    • pp.453-469
    • /
    • 2011
  • A one-story, wooden-frame, intermediate-bay model with Dou-Gon designed according to the Building Standards of the Song Dynasty (A.D.960-1279), was tested on a unidirectional shaking table. The main objectives of this experimental study were to investigate the seismic performance of Chinese historic wooden structure under various base input intensities. El Centro wave (N-S), Taft wave and Lanzhou wave were selected as input excitations. 27 seismic geophones were instrumented to measure the real-time displacement, velocity and acceleration respectively. Dynamic characteristics, failure mode and hysteretic energy dissipation performance of the model are analyzed. Test results indicate that the nature period and damping ratio of the model increase with the increasing magnitude of earthquake excitation. The nature period of the model is within 0.5~0.6 s, the damping ratio is 3~4%. The maximum acceleration dynamic magnification factor is less than 1 and decreases as the input seismic power increases. The frictional slippage of Dou-Gon layers (corbel brackets) between beams and plates dissipates a certain amount of seismic energy, and so does the slippage between posts and plinths. The mortise-tenon joint of the timber frame dissipates most of the seismic energy. Therefore, it plays a significant part in shock absorption and isolation.

A Study on the Safety Management Differences According to Social Welfare Facility Type (사회복지시설의 유형에 따른 안전관리의 차이에 관한 연구)

  • Shin, Hyo-Jin;Kong, Ha-Sung
    • Fire Science and Engineering
    • /
    • v.28 no.5
    • /
    • pp.89-97
    • /
    • 2014
  • At a time of growing importance of safety management in the social welfare facility by the increase of social welfare facilities, this study analysed safety perceptions about facility management, facility conditions, and facility structure and arrangement. This study sample consisted of 204 service providers and service users in 12 social welfare facilities. T-test and ANOVA were used to find the group differences among facility types. The findings were as follows. Firstly, safety perceptions of the service providers were significantly higher than those of service users in terms of facility management, and facility structure and arrangement. Secondly, in terms of facility types, the respondents in the family service center had lower safety perceptions than the respondents in other service in all three areas. Thirdly, facilities that are of 10 years or older had higher safety perceptions than the respondents of facilities that are 6 to 10 years old in the area of facility management, and facility structure and arrangement. Fourthly, in regard to building heights, the respondents in 3 to 4 story facilities had statistically higher safety perceptions than respondents in 1 story facilities. Finally, looking at the relationship between floor area and safety perceptions, safety perceptions of the respondents of less than $400m^2$ facilities or $600m^2$ and more facilities were significantly higher than those of $400m^2{\sim}$ less than $600m^2$ facilities.