Semismic Analysis of Building Structures with Base Isolation System

Base Isolation System이 있는 건물의 지진하중에 대한 동적해석

  • Published : 1990.03.01

Abstract

The isolation system is installed at the base of a structure for reduction of the earthquake damage to the structure. In the 1970', when the laminated rubber bearing(LR type) is developed, the isolation system is put in practice. And recently a new isolation system(SR type), including the laminated rubber bearing with the friction plate beneath, is developed. In this thesis, a study on the base isolation effect, for various of the isolation system and structure properties, is performed. The results of this parameter study show that the isolation system can reduce the earthquake damage of the building structures significantly. As the period of isolation system increases, the isolation effect increases and converges to zero damage. As the number of story increases, the isolation effect reduces. It is found that SR type isolation system is more effective than LR type because SR type base isolation system reduces acceleration, drift and total displacement.

Base isolation system은 구조물의 기초하부에 설치되며 지진에 의한 구조물의 피해를 감소시켜 준다. 지금까지 많은 공학들에 의해 여러가지 base isolation system이 개발되었으나 실용화된 것은 1970년대에 laminated rubber bearing(LR type)이 개발되고서부터 였다. 최근에는 laminated rubber bearing밑에 미끄럼판을 둔 새로운 base isolation system(SR type)이 개발되었다. 본 연구에서는 isolation system과 구조물의 여러가지 성질에 따른 isolation효과에 대한 연구를 수행하였다. 이 연구의 결과, isolaion system은 지진하중이 작용할 때 건물에 발생하는 피해를 상당히 감소시킴을 알 수 있으며, isolaion system의 주기가 길어짐에 따라 isolation효과는 증가함을 알 수 있다. 그리고 건물의 높이가 증가함에 따라 isolation효과는 줄어든다는 것을 알 수 있다. SR type isolation system이 있는 건물에 지진하중이 작용할 때, 건물내부에서 발생하는 가속도와 층간변위, 그리고 전체변위는 LR type의 경우보다 작으므로 보다 효율적이라는 것을 알 수 있다.

Keywords