• 제목/요약/키워드: 3 Story Building Structure

검색결과 177건 처리시간 0.025초

Optimal Design of Tall Residential Building with RC Shear Wall and with Rectangular Layout

  • Jinjie, Men;Qingxuan, Shi;Zhijian, He
    • 국제초고층학회논문집
    • /
    • 제3권4호
    • /
    • pp.285-296
    • /
    • 2014
  • The objective of optimization is to present a design process that minimizes the total material consumption while satisfying current codes and specifications. In the research an optimization formulation for RC shear wall structures is proposed. And based on conceptual design methodology, an optimization process is investigated. Then optimal design techniques and specific explanations are introduced for residential buildings with shear wall structure, especially for that with a rectangular layout. An example of 30-story building is presented to illustrate the effectiveness of the proposed optimal design process. Furthermore, the influence of aspect ratio on the concrete consumption and the steel consumption of the superstructure are analyzed for this typical RC shear wall structure; and their relations are obtained by regressive analysis. Finally, the optimal material consumption is suggested for the residential building with RC shear wall structure and with rectangular layout. The relation and the data suggested can be used for guiding the design of similar RC shear wall structures.

벽식 아파트 구조에서 연결부재의 거동특성을 고려한 비선형 동적 응답 (Nonlinear Dynamic Response of Well-Slab Apartment Building Considering The Behavior of Coupling Elements)

  • 김기현;장극관;서대원;천영수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.437-442
    • /
    • 2002
  • The purpose of this study is to investigate nonlinear behavior and estimate ultimate resistance of the wall structure against seismic loading. Experimental data for RC coupling elements are used for specifying the strength deterioration and stiffness degradation factor of hysteretic model. Modified coupling element models are used in the push over analysis and time history analysis. In the time history analysis, three earthquake waves are used in the analysis and their peak ground accelerations are changed to be 0.2g. The conclusions of this study are as follows : (1) In the push over analysis, yielding of coupling elements occurred at lower story with small story drift ratio as 0.3%. (2) In the time history analysis, the story drift ratio is sufficient for the requirement of Korean Code, But coupling elements at most stories of the buildings occurred yielding. i. e. the earthquake resistant capacity of shear wall structures is not sufficient at 0.2g.

  • PDF

동양목조탑파(東洋木造塔婆)의 구조형식(構造形式)에 관한 연구(硏究) - 법주사(法住寺) 팔상전(捌相殿)과 법륭사(法隆寺) 오중탑(五重塔)의 비교분석적 측면에서 - (The Structure of Oriental Wooden Pagoda)

  • 김경표;등정혜개;이민섭
    • 건축역사연구
    • /
    • 제1권1호
    • /
    • pp.88-105
    • /
    • 1992
  • This dissertation aims to investigate the structure of Palsangjeon, a five story wooden pagoda in Pubjoo Temple which is the only wooden pagoda existing in Korea, by a comparative study of the Palsangjeon with Japanese counterparts. By doing so, the writer of the present investigation attempts to find out its structural originality. The main finding of this study are as follows. The upper part of Palsangjeon is constructed with square log frameworks called GuiTl and Sacheon-Ju around the central column. The four walls along Sacheon-Ju from the 1st level to the 3rd well resists the outside horizontal piressure. And Gui-Tl structure on the 5th level copes much better with shear force. So this frame consisting of Sacheon-Ju and log frameworks might be viewed an semi-core system, This core is supported once again by the frame of Go-Ju. That is to say. Go-Ju supports frame of Sacheon-Ju. And the frame of Pyeong-Ju on the 4th and the 5th levels also supports it. The frame of Go-Ju is supported by the frame of Pyeong-Ju on the 1st and the 2nd levels. So this structure is designed to resist the wind and also keep the balance by properly distributing vertical pressure. The plan and the elevational structure of Palsangjeon keep the balance by the perfect symmetric structure. And the frame of Sacheon-Ju forming semi-core system can resist both the lateral load and the vertical pressure for the balance of its structure. The five story pagoda in Horyuji used to stand on a central which is desigend to support the main body of the pagoda from the first level. The principles of balance is used between the Ha-Aag and short to react the rafter. Sacheon-Ju and edge column is against the lateral load. The structural jointing system is stable thanks to the log framewroks formed on every level. The five story pagoda in Horyuji poseses the structual system originated from the ancient wooden pagoda. The pagoda is found to express simple, sincere and straight forward form. On the other hand, it could be seen as a stucture resisting the earthquake and the lateral load, Palsangjeon is an excellent building which religions function is well harmonized with its structure and appearance. It not only functions extremely well as a regions place like other pagodas, but also excellently shows how multi-story wooden building should be structured.

  • PDF

Optimization of base-isolated structure with negative stiffness tuned inerter damper targeting seismic response reduction

  • Jean Paul Irakoze;Shujin Li;Wuchuan Pu;Patrice Nyangi;Amedee Sibomana
    • Earthquakes and Structures
    • /
    • 제25권6호
    • /
    • pp.399-415
    • /
    • 2023
  • In this study, we investigate the use of a negative stiffness tuned inerter damper system to improve the performance of a base-isolated structure. The negative stiffness tuned inerter damper system consists of a tuned inerter damper connected in parallel with a negative stiffness element. To find the optimal parameters for the base-isolated structure with negative stiffness tuned inerter damper system, we develop an optimization method based on performance criteria. The objective of the optimization is to minimize the superstructure acceleration response ratio, while ensuring that the base displacement response ratio remains below a specified target value. We evaluate the proposed method by conducting numerical analyses on an eight-story building. The structure is modeled using both a simplified 3-degree-of-freedom system and a more detailed story-by-story shear-beam model. Lastly, a comparative analysis using time history analysis is performed to compare the performance of the base-isolated structure with negative stiffness tuned inerter damper system with that of the base-isolated structure and base-isolated structure with tuned inerter damper systems. The results obtained from the comparative analysis show that the negative stiffness tuned inerter damper system outperforms the tuned inerter damper system in reducing the dynamic seismic response of the base-isolated structure. Overall, this study demonstrates that the negative stiffness tuned inerter damper system can effectively enhance the performance of base-isolated structures, providing improved seismic response reduction compared to other systems.

축소 건물모델의 모달 파라미터 추정에 관한 연구 (A Study on the Modal Parameters of the scaled building structure)

  • 박해동;박진일;최현;김두훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.571-575
    • /
    • 2000
  • The physical properties of the spatial model, mass, stiffness and damping matrix, can be defined by a specific natural frequency, damping ratio and mode shape. These modal parameters can be determined from a set of frequency response function(FRF) measured by exciting the structure and measuring the responses at various points around the structure. In this paper, The Transfer Matrix is obtained by experimental modal analysis for the 3-story scaled building model which TMD is installed on top and the physical properties of the spatial model is determined using the residue matrix and the location of poles from FRF measurement using polynomial curve fitting methods.

  • PDF

OKID를 이용한 실험 건물모델의 시스템 식별 실험 (Observer Kalman Filter Identification of a Three-story Structure installed with Active Mass Driver)

  • 주석준;이상현;민경원
    • 한국전산구조공학회논문집
    • /
    • 제17권2호
    • /
    • pp.161-169
    • /
    • 2004
  • 본 논문은 축소 3층 건물의 최상층에 능동질량형 제어장치를 설치한 시스템에 관한 식별실향분석이다. OKID기법을 적용하여 진동대 및 제어장치의 가진 입력과 건물 및 제어장치의 응답인 출력관계를 분석하여 수학모델을 구하였다. 제어장치가 설치된 건물에 관한 입력은 진동대에 의한 지반가속도와 제어장치 모터의 구동신호이다 그리고 출력은 건물 각층과 제어장치의 가속도이다. 입출력 관계로 구하여진 수학모델을 바탕으로 제어장치의 최적설계를 수행하였으며 수치해석과 실험결과를 비교한바 서로 일치함을 확인할 수 있었다.

A new damage index for detecting sudden change of structural stiffness

  • Chen, B.;Xu, Y.L.
    • Structural Engineering and Mechanics
    • /
    • 제26권3호
    • /
    • pp.315-341
    • /
    • 2007
  • A sudden change of stiffness in a structure, associated with the events such as weld fracture and brace breakage, will cause a discontinuity in acceleration response time histories recorded in the vicinity of damage location at damage time instant. A new damage index is proposed and implemented in this paper to detect the damage time instant, location, and severity of a structure due to a sudden change of structural stiffness. The proposed damage index is suitable for online structural health monitoring applications. It can also be used in conjunction with the empirical mode decomposition (EMD) for damage detection without using the intermittency check. Numerical simulation using a five-story shear building under different types of excitation is executed to assess the effectiveness and reliability of the proposed damage index and damage detection approach for the building at different damage levels. The sensitivity of the damage index to the intensity and frequency range of measurement noise is also examined. The results from this study demonstrate that the damage index and damage detection approach proposed can accurately identify the damage time instant and location in the building due to a sudden loss of stiffness if measurement noise is below a certain level. The relation between the damage severity and the proposed damage index is linear. The wavelet-transform (WT) and the EMD with intermittency check are also applied to the same building for the comparison of detection efficiency between the proposed approach, the WT and the EMD.

동적응답신호를 이용한 전단형 건물의 손상추정 (Damage Detection of Shear Building Structures Using Dynamic Response)

  • 유석형
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권3호
    • /
    • pp.101-107
    • /
    • 2014
  • 구조물의 손상 추정은 동적응답신호로부터 고유주기와 모드형상을 구한 후 이를 역해석하여 손상위치와 손상정도를 파악함으로써 이루어 진다. 건축구조물의 경우 토목구조물에 비하여 구조형식이 복잡하고 비구조요소 및 노이즈 등의 영향으로 인하여 구조물 판별에 어려움이 있다. 동적응답신호를 이용한 건물의 손상추정에 관한 최근의 연구들은 손상추정을 위하여 민감도 또는 추정치 등 간접적 지표를 사용하고 있으나, 좀 더 합리적이고 명확한 손상추정을 위하여 운동방정식으로부터 직접 유도된 변수를 손상지수로 활용할 필요가 있을 것으로 판단된다. 따라서 본 연구에서는 전단형 건물의 운동방정식으로부터 직접 유도된 층강성 감소비를 손상지수로 하는 손상추정 방법을 제안하였다. 제안된 손상지수는 손상 전 모드형상과 손상 전 후 고유진동수 차이를 알면 구할 수 있다. 제안된 손상 추정방법을 수치해석예제에 적용한 결과 손상이 발생한 층에서 층강성 변화율이 (-)부호를 나타내었으며, 크기가 다른 층에 비하여 15배 정도 크게 나타나 전단형 건물의 손상 추정지수로서 활용될 수 있을 것으로 판단된다.

고려(高麗) 금동탑(金銅塔)을 통해 본 법주사(法主寺) 팔상전(捌相殿)의 구조형식계통(構造形式系統) (The Structural Lineage of Palsangjeon in Pubjoo Temple Analyzed through Gilt-bronze Pagoda in the Koryo Period)

  • 김경표
    • 건축역사연구
    • /
    • 제14권1호
    • /
    • pp.89-105
    • /
    • 2005
  • The central aim of this thesis is to see if the structure of Palsangjeon(捌相殿) in Pubjoo Temple(法住寺), a five sto wooden pagoda in Chosen(朝鮮) Dynasty, was handed down from the ancient and middle ages. This study was performed through an analysis of Gilt-Bronze Pagoda built in Koryo(高麗) period. In other words, it is aimed at analyzing which lineage the structure of Palsangjeonbelongs to as a wooden pagoda. In analyzing the structure of Palsangjeon, I attempted to find out its source from the remains of Koryo period prior to the Chosen Dynasty. Examples are the Gilt-Bronze Pagoda, built during the Koryo period. I have also examined its relationship with other existing wooden pagodas and remains. The analysis of Palsangjeon, a five story wooden pagoda in Chosen Dynasty, focuses on the following: First, I explored the possibilities of whether the structure of Palsangjeon was newly invented in Chosen Dynasty, or if it had been derived from the wooden pagodas in the Koryo period. Secondly, I tried to find out if the stable vertical planes, with a great successive diminution ratio, were derived from the middle age, i.e. Koryo period. The results of the study of Palsangjeon through Gilt-Bronze Pagoda analysis are as follows: 1. The structure of Gilt-Bronze Pagoda, a wooden pagoda from the Koryo period, is roughly classified into the accumulation type, using pipe pillars, and the one story type using whole pillars. In the accumulation type, stories are connected in either a flat format or an intervening format. The Gilt-Bronze Pagoda is mainly composed of pipe pillars, with some whole pillars. However, the central pillar was omitted in the building structure. Generally, the upper and lower stories are connected by pipe pillars in a crutch format. All the pillars, whether they are pipe pillars or whole pillars, used Naiten(內轉) technology. The Eave supporter has the Haang type(下昻) and the Muhaang type(無下昻). In most cases, high balustrades are furnished, but few tables of high balustrades have been found. The slanting roof formats have been handed down from Paekche(百濟), Silla(新羅), or Koryo(高麗). However, the structure of the octagon is assumed to be derived from Koguryo(高句麗). The structure of the Gilt-Bronze Pagoda from the Koryo period is mainly composed of accumulated flat squares, with some spire types. intervening format, the structure of Palsangjeon used whole pillars in a half story format in which upper level side pillars are installed on the lower level tie beam. From the Bronze Pagoda from the Koryo period, we can assume that the half story format of wooden pagodas that has stable vertical planes with a great successive diminution ratio was created during the mid-Koryo period at the latest and had been idly developed by the time of the Chosen Dynasty. 3. The whole pillars in Palsangjeon are also found in Gilt-Bronze Pagodas from the Koryo period. Hence, all of the pillars in Palsangjeon seem to have been handed down from the ancient construction technology. They were also used in the construction of wooden pagodas from the Koryo period. Therefore, it is assumed that Palsangjeon was constructed using the construction technology of the Chosen Dynasty that had been developed from the wooden pagoda construction technology of the Koryo period. The stable vertical planes with a great successive diminution ratio in Palsangjeon are derived from ancient Korean wooden pagodas, which have developed into indigenous Korean wooden pagodas with fairly stable vertical planes and a great design, in the half story format of Koryo and Chosen Dynasty. Therefore, it is assumed that the structure of Palsangjeon has a systematic relationship with traditional Korean wooden pagodas and is one of the indigenous Korean wooden pagoda structures. 4. In China, the intervening format has been mainly used between stories in multi-story architecture since the ancient days. At the same time, the flat format as also used in ancient and middle ages. However, the flat format was replaced by whole pillars during the Ming(明) and Manchu(淸) Dynasties, in favor of simple and compact construction. The half-story format, in which upper level side pillars are installed on tie beams, has been found in some cases, but it doesn't seem to have been the primary construction technology. Few traces of the half-story format have been found in multi-story architecture in Japan, and it has not been used as a general construction format. By contrast, the half-story format, which seems to have been derived from the Koryo period, was used as a general construction format in multi-story architecture of the Chosen Dynasty. The construction technology of multi-story architecture is related to that of multi-story wooden pagodas, but they have different production technologies. It seems that the structure of Palsangjeon did not just adopt the construction technology of multi-story architecture in the Chosen Dynasty, but it was developed from wooden pagodas in the Koryo period, including the Gilt-Bronze Pagoda. 5. Since the ancient days, most Chinese and Japanese wooden pagodas have adopted an accumulation type of structure using pipe pillars, with accumulated pointed towers. On the other hand, though most Korean wooden pagodas have also adopted an accumulation type of structure from the ancientdays, one story type using whole pillars was created in the Koryo and Chosen Dynasties. The wooden pagoda structure of Palsangjeon, with stable vertical planes in a half story format, is a unique Korean construction technology, different from the construction technologies of Chinese and Japanese wooden pagodas. This thesis clearly determined the structural characteristics of Palsangjeon. However, various remains have yet to be analyzed in depth, to establish an accurate construction technology system. In the beginning of this thesis, I had difficulty in precisely interpreting the internal structure of the Gilt-Bronze Pagoda from its appearance. However, in the process of study, the more serious problem was that there are few remains or ruins of multi-story architecture in ancient and the middle ages of Korea. Therefore, it is urgent to discover various remains in the future. This thesis succeeded in determining the structural characteristics of Palsangjeon. However, it fell short of clarifying the structural lineage of the stable vertical planes, although they show indigenous Korean architectural taste, representing the unique national emotion, and the construction format of multi-story wooden pagodas in Korea. I hope this is clarified in the future research.

  • PDF

3층 철근콘크리트조 건물의 손상전후의 진동특성 (Vibration Characteristics of a Three-Story Reinforced Concrete Building Before and After Damage)

  • 윤성원;박용;지정환;임재휘;장동우
    • 한국공간구조학회논문집
    • /
    • 제9권3호
    • /
    • pp.59-66
    • /
    • 2009
  • 구조물이 건전한 상태에서 진동계측을 통한 고유진동수와 감쇠율과 같은 동적특성의 분석에 대하여 국내 외적으로 많은 연구가 진행되어 왔다. 그러나 실물 구조물에 대하여 파괴 직전까지의 큰 손상 후에 진동계측을 통한 동적특성에 대한 연구는 상대적으로 매우 미약한 실정이다. 따라서 본 연구는 3층 철근콘크리트조 건물에 엑츄에이터로 하중을 주어 건물에 손상을 준 후에 손상 전 후의 진동계측을 통하여 동적특성을 파악하였다. 손상 전 후에 대한 고유진동수 및 감쇠율을 산정하였으며, 이 결과를 국외의 기존 연구와 비교하였다. 상시진동계측 및 인력가진을 통한 계측방법을 실시하였으며, 계측 전에 고유치 해석을 선행하여 계측치와 비교분석을 하였다. 120mm의 수평변위를 준 결과 구조물의 파괴 직전 손상 전 후에 장변과 단변의 고유진동수는 각각 34.3%, 33.7% 감소하였고, 감쇠율은 각각 36.5%, 19.5% 감소하였다. 기존 국외의 연구결과와의 비교를 한 결과 고층형 건물보다 강성의 변화가 크게 감소됨을 확인할 수 있었으며, 저층형 구조물에 대한 안정성 검토가 시급함을 확인할 수 있다.

  • PDF