• Title/Summary/Keyword: 3 Point bending test

Search Result 370, Processing Time 0.026 seconds

Microstructure and Mechanical Properties of Alumina/Zirconia Layered Composites (알루미나/지르코니아 층상 복합체의 미세구조 및 기계적 성질)

  • Lyu, Seung-Woo;Park, Young-Min;Yang, Tae-Young;Ryu, Su-Chak;Kim, Young-Woo;Yoon, Seog-Young;Park, Hong-Chae
    • Journal of the Korean Ceramic Society
    • /
    • v.43 no.3 s.286
    • /
    • pp.193-197
    • /
    • 2006
  • Symmetric three-layer $Al_2O_3/ZrO_2$ composite has been prepared by freeze casting and pressureless sintering at $1400-1600^{\circ}C$ in air. The layered material sintered at $1600^{\circ}C$ showed the maximum fracture strength (410 MPa), measured by a four-point bending test. Contact damage strength was superior in three-layer composite compared with corresponding mono-layered material, possibly due to the development of relatively large compressive stress. The grain growth of $ZrO_2$ particles was mainly governed by coalescence mechanism.

Evaluation of Mechanical Properties and Fatigue Behavior of STS 304L due to Plastic Working (소성가공에 따른 STS 304L 재료의 기계적 특성 및 피로평가)

  • Shim, Hyun-Bo;Kim, Young-Kyun;Suh, Chang-Min
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.7
    • /
    • pp.635-643
    • /
    • 2017
  • The purpose of this study is to investigate the influence of the cold reduction rate and an ultrasonic fatigue test (UFT) on the fatigue behaviors of STS 304L. The tensile strength, yield strength, hardness value and fatigue limit in the UFT fatigue test linearly increased as thickness decreased from 1.5 mm to 1.1 mm, as the cold reduction rate of STS 304L increased. As a result of the UFT fatigue test (R = -1) of four specimens, the fatigue limit of the S-N curve formed a knee point in the region of $10^6$, and the 2nd fatigue limit caused by giga cycle fatigue did not appeared. In the case of t = 1.1 mm, the highest fatigue limit was 345 MPa, which was 64.3% higher than the original material (t = 1.5 mm). As a result of the UFT fatigue test of STS 304L, many small surface cracks occurred, grown, coalesced while tearing.

Probabilistic Analysis of Fatigue Behavior of Induction Hardened Steel (고주파 열처리된 SAE1055 강의 피로거동 및 이의 확률론적 평가)

  • Lee, Seon-Ho;Lee, Seung-Pyo;Kang, Ki Weon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.3
    • /
    • pp.429-436
    • /
    • 2013
  • This study considers how the fatigue behavior and probabilistic properties of SAE1055 steel are related to its hardness level. SAE1055 steel was heat-treated using induction hardening. Five types of specimens were prepared (A: base material, B: through hardened material with HV390, C: through hardened material with HV510, D: through hardened material with HV700, and E: surface hardened material with HV700). Fatigue tests were performed under a stress ratio of R = -1 using a 4-point rotary bending fatigue tester. The fatigue behaviors were greatly influenced by the hardness, but the fatigue limit did not increase over a hardness of HV510. In addition, the effect of the hardness level on the failure mechanism was evaluated using a scanning electron microscope. The probabilistic properties of the fatigue life were investigated using a probabilistic S-N approach, and the effect of the hardness level on these properties was evaluated using a residue analysis.

Changes of Strength and Stiffness of Freeze-Dried Bovine Cortical Bone according to Rehydration Time in Electrolyte Solution (동결건조한 소의 치밀골에서 전해질용액의 침지시간에 따른 Strength와 Stiffness의 변화)

  • 김남수;장세웅;김희은;정인성;최성진;최인혁
    • Journal of Veterinary Clinics
    • /
    • v.20 no.4
    • /
    • pp.482-488
    • /
    • 2003
  • Transplanted cortical bone grafts of freeze-dried bones also function as sustaining for defected bones, however, it has less strength and is fragile without rehydration. In this study, strength and stiffness of freeze-dried bone from bovine cortical bones were evaluated by three point bending test according to different time frames such as rehydration times of 0.5, 3, 6, 12 and 24 hrs in electrolyte solution and was compared with those of frozen bones. The strength and stiffness of frozen bone were $264.4\pm36.7$ MPa, $17.0\pm1.5$ GPa, respectively. The strength and stiffness of freeze-dried bone which fat was removed by treatments of chloroform-methanol solutions for 6 days, then was freeze-dried at $-80^{\circ}C$ and sterilized with ethylene oxide gas, were $224.9\pm27.6$ MPa, $19.2\pm2.8$ GPa, respectively. The strength and stiffness of feeze-dried bone were decreased 15.0% and increased 13.2% than these of frozen bone, respectively. The strength and stiffness of freeze-dried bone rehydrated for 6 hrs were restored to 96.0% strength and 99.2% stiffness of frozen bone. The rehydration time of freeze-dried bone which had the highest strength and stiffness was six hours and three hours, respectively. The results of the mathematica program for the variation of the strength and stiffness showed 3 hours and 30 minutes of rehydration time in electrolyte solution for the best condition in the strength and stiffness which was adequate to treat freeze-dried cortical bone.

Effect of water storage on flexural strength of silorane and methacrylate-based composite resins

  • Panahandeh, Narges;Torabzadeh, Hassan;Naderi, Hani;Sheikh-Al-Eslamian, Seyedeh Mahsa
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.4
    • /
    • pp.309-315
    • /
    • 2017
  • Objectives: This study assessed the effect of water storage on the flexural strength (FS) of low shrinkage composites. Materials and Methods: A total of 165 bar-shaped specimens ($2{\times}2{\times}25mm$) were fabricated of 2 low shrinkage composites (Filtek P90 [3M ESPE], GC Kalore [GC International]) and a conventional methacrylate-based composite (Filtek Z250 [3M ESPE]). The specimens were subjected to 3-point bending test at 6 time intervals, namely: immediately after curing, at 24 hours, 1 week, 1 month, 6 months, and 1 year following storage in wet and dry conditions. The FS of the specimens were measured by applying compressive load at a crosshead speed of 1.0 mm/min. Data was analyzed using 3-way analysis of variance (ANOVA) and Tukey's test. Results: Three-way ANOVA revealed significant interactions between time, type of composite, and storage condition (p = 0.001). Tukey's multiple comparison test revealed significant reductions in FS of all composites after 6 months and 1 year of storage in distilled water compared to dry condition. Conclusions: Filtek P90 showed the highest and GC Kalore showed the lowest FS after 1 year storage in distilled water. The immediate high strength of Filtek Z250 significantly decreased at 1 year and its final value was lower than that of Filtek P90.

The Penetration Characteristics of CFRP Laminated Shells on the Change of Stacking Sequences and Curvatures (적층구성 및 곡률 변화에 따른 CFRP 적층쉘의 관통특성)

  • Cho, Young-Jea;Kim, Young-Nam;Yang, In-Young
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.1
    • /
    • pp.79-85
    • /
    • 2006
  • CFRP(Carbon Fiber Reinforced Plastics) of the advanced composite materials as structural materials for vehicle, has a wide application in light-weigh structural materials of airplanes, ships and automobiles because of high strength and stiffness, However, there is a design variable to be considered in practical application of the laminate composite materials, these materials are vulnerable to transverse impact. This paper is to study the effects of stacking sequence and curvature on the penetration characteristics of composite laminate shell. They are stacked to $[0_3/90_3]S,\;[90_3/0_3]s\;and\;[0_2/90_3/0]s,\;[90_2/0_3/90]s$ and their interlaminar number two and four. They are manufactured to various curvature radius (R=100, 150, 200mm and $\infty$), When the specimen is subjected to transverse impact by a steel ball, the velocity of the steel ball was measured both before and after impact by determing the time for it to pass two ballistics-screen sensors located a known distance apart. The critical penetration energy of specimen A and B with less interfaces were a little higher than those of C and D. As the curvature increases, the critical penetration energy increases linearly because the resistance to the in-plane deformation as well as bending deformation increases, which need higher critical penetration energy. The specimen A and C have higher critical penetration energy than B and D because of different stacking sequences. We examined crack length through a penetration test. For the specimen A with 2interfaces, the longest circumferential direction crack length were observed on the first interface from the impact point. For the specimen B 4-interface, the longest circumferential direction crack length were observed on the second interface from the impact point.

Effect of solution temperature on the mechanical properties of dual-cure resin cements

  • Kang, En-Sook;Jeon, Yeong-Chan;Jeong, Chang-Mo;Huh, Jung-Bo;Yun, Mi-Jung;Kwon, Yong-Hoon
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.2
    • /
    • pp.133-139
    • /
    • 2013
  • PURPOSE. This study was to evaluate the effect of the solution temperature on the mechanical properties of dualcure resin cements. MATERIALS AND METHODS. For the study, five dual-cure resin cements were chosen and light cured. To evaluate the effect of temperature on the specimens, the light-cured specimens were immersed in deionized water at three different temperatures (4, 37 and $60^{\circ}C$) for 7 days. The control specimens were aged in a $37^{\circ}C$ dry and dark chamber for 24 hours. The mechanical properties of the light-cured specimens were evaluated using the Vickers hardness test, three-point bending test, and compression test, respectively. Both flexural and compressive properties were evaluated using a universal testing machine. The data were analyzed using a two way ANOVA with Tukey test to perform multiple comparisons (${\alpha}$=0.05). RESULTS. After immersion, the specimens showed significantly different microhardness, flexural, and compressive properties compared to the control case regardless of solution temperatures. Depending on the resin brand, the microhardness difference between the top and bottom surfaces ranged approximately 3.3-12.2%. Among the specimens, BisCem and Calibra showed the highest and lowest decrease of flexural strength, respectively. Also, Calibra and Multilink Automix showed the highest and lowest decrease of compressive strength, respectively compared to the control case. CONCLUSION. The examined dual-cure resin cements had compatible flexural and compressive properties with most methacrylate-based composite resins and the underlying dentin regardless of solution temperature. However, the effect of the solution temperature on the mechanical properties was not consistent and depended more on the resin brand.

High Temperature Oxidation Behavior and Mechanical Characteristic of Recrystallized Alloy 617 (재결정에 따른 Alloy 617의 고온 산화 거동 및 기계적 특성)

  • Lim, Jeong Hun;Jo, Tae Sun;Park, Ji Yeon;Kim, Young Do
    • Korean Journal of Metals and Materials
    • /
    • v.48 no.12
    • /
    • pp.1078-1083
    • /
    • 2010
  • In this study, high temperature oxidation behavior of Alloy 617 was investigated to evaluate the effect of grain size for Alloy 617. The grain size of grain-refined Alloy 617 (GR617) was reduced to $5{\mu}m$ from $71{\mu}m$ for as-received Alloy 617 (AR617) by recrystallization after cold rolling. After high temperature aging, the oxide layers of AR617 and GR617 consisted of $Cr_2O_3$ external oxide scale and $Al_2O_3$ internal oxide. The external oxide scale resulted in a Cr-depleted zone and a carbide free zone below the scale. The depth of the carbide free zone was deeply formed in GR617. On the other hand, the depth of the internal oxide layer in GR617 was shorter than that in AR617. After a 3-point bending test, crack propagation of GR617 was more restricted than that of AR617 because of the different microstructure of the internal oxide.

Strengthening Depth Effect in Externally Post-tensioning Shear Strengthening of Pre-cracked Reinforced Concrete Beam (사전균열이 발생한 철근콘크리트 보의 외적 포스트텐셔닝 전단보강에서 보강깊이의 효과)

  • Lee, Swoo-Heon;Shin, Kyung-Jae;Lee, Hee-Du
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.11
    • /
    • pp.19-26
    • /
    • 2018
  • This paper presents the shear strengthening effect of externally post-tensioning (EPT) method using high-strength steel rod in pre-cracked reinforced concrete (RC) beams. Three- and four-point bending tests were performed on a total of 8 specimens by adjusting the strengthening depths in the deviator position of EPT. The effective strengthening depths were 435, 535, and 610 mm. The pre-loading up to about 2/3 of ultimate load capacity measured in unstrengthened RC beam were applied in the beam to be post-tensioned. The EPT method was then applied to the pre-damaged RC beams and re-loading was added until the end of the test. EPT restored deflections of 3 mm or more, which account for about 40% of deflection when the pre-loading was applied. The shear strengthening increases more than 3 times and 36~107% in terms of the stiffness and load-carrying capacity compared to unstrengthening RC beams. The increased load-carrying capacities of the post-tensioned beam with strengthening depths of 435 and 535 mm are almost the same as 36~61%, and those of 610 mm are 84~107%, which shows the greatest shear strengthening effect.

Mechanical behavior of HPFRCC using limestone calcined clay cement (LC3) and oxygen plasma treated PP fibers

  • Sajjad Mirzamohammadi;Masoud Soltani
    • Structural Engineering and Mechanics
    • /
    • v.89 no.4
    • /
    • pp.349-362
    • /
    • 2024
  • High-performance fiber-reinforced cement composites (HPFRCC) are new materials created and used to repair, strengthen, and improve the performance of different structural parts. When exposed to tensile tension, these materials show acceptable strain-hardening. All of the countries of the globe currently seem to have a need for these building materials. This study aims to create a low-carbon HPFRCC (high ductility) that is made from materials that are readily available locally which has the right mechanical qualities, especially an increase in tensile strain capacity and environmental compatibility. In order to do this, the effects of fiber volume percent (0%, 0.5%, 1%, and 2%), and determining the appropriate level, filler type (limestone powder and silica sand), cement type (ordinary Portland cement, and limestone calcined clay cement or LC3), matrix hardness, and fiber type (ordinary and oxygen plasma treated polypropylene fiber) were explored. Fibers were subjected to oxygen plasma treatment at several powers and periods (50 W and 200 W, 30, 120, and 300 seconds). The influence of the above listed factors on the samples' three-point bending and direct tensile strength test results has been examined. The results showed that replacing ordinary Portland cement (OPC) with limestone calcined clay cement (LC3) in mixtures reduces the compressive strength, and increases the tensile strain capacity of the samples. Furthermore, using oxygen plasma treatment method (power 200 W and time 300 seconds) enhances the bonding of fibers with the matrix surface; thus, the tensile strain capacity of samples increased on average up to 70%.