• Title/Summary/Keyword: 3차원 프로브

Search Result 54, Processing Time 0.023 seconds

Calibration/Compensation of Errors of the Touch Probe (접촉식 프로브의 오차교정 및 보정기술)

  • 박희재;이교일
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.8
    • /
    • pp.2081-2087
    • /
    • 1994
  • Touch trigger probes are widely used for inspection purposed in the CMM(Coordinate meauring machine) or machine tool. The errors introduced by measurement probe are fairy systematic, thus can be calibrated and compensated properly. This paper presents a technique for the error calibration and compensation of the probe errors, which can be easily applicable to the manufacturers and users of the measurement probe. The probe coordinate system is defined for the probe error assessment, and a reference sphere ball is measured, and the probe errors are calibrated. The calibrated probe errors are represented in the 3D error map and 2D error map along probing direction. Detail algorithms for the error compensation are proposed.

Numerical Analysis of ECT for Investigation of SG Tube in NPP (원전 증기발생기세관 진단을 위한 와전류탐상 수치해석)

  • Lim, Geon-Gyu;Lee, Hyang-Beom
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2008.08a
    • /
    • pp.509-512
    • /
    • 2008
  • 본 논문에서는 원전 증기발생기세관 진단을 위한 와전류탐상의 전자기 수치해석을 수행하였다. 전자기적 특성을 해석하기 위하여 맥스웰 방정식을 이용하여 지배방정식을 유도하였고, 3차원 전자기 유한요소 프로그램인 OPERA 3D를 이용하여 전자기 수치 해석을 수행하였다. 신호해석을 위해 사용된 프로브의 종류는 배열와전류프로브이며, FBH 결함의 신호를 해석하였다. 결함의 깊이는 세관 두께의 40[%], 60[%] 및 100[%]로 하였다. 시험주파수는 100[kHz], 300[kHz], 400[kHz]를 사용하였고, 각각의 결함 및 시험주파수에 대한 결과를 비교 분석하였다. 본 논문의 결과는 앞으로 배열와전류프로브를 이용하여 원전 증기발생기세관 진단을 할 경우 신호 해석에 도움이 될 것으로 사료된다.

  • PDF

Measurement of Motion Accuracy by Two-dimensional Probe on NC Machine Tools -2nd Report, Measurement of the Linear Motion Accuracy- (2차원 프로브에 의한 NC공작기계의 운동 정밀도 측정 -제2보 직선운동 정밀도 측정-)

  • JEON, Eon Chan;OYAMADA, Shigenori;TSUTSUMI, Masaomi;KAKUTA, Junichro
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.7
    • /
    • pp.15-21
    • /
    • 1997
  • This paper presented a linear motion accuracy by using two-dimensional probe with the master block and the square for NC machine tools. This measuring system could be measured motion error due to numerical control system. The results of measurement and simulation for motion error were similar, and so, this system had enough accuracy to measure a linear motion accuracy for NC machine tools. The experimental results are as follows. 1. This measuring system could be measured motion error due to mumerical control system. 2. The results of measurement and simulation for motion error were similar. 3. This measuring system had enough accuracy to measure a linear motion accuracy for NC machine tools.

  • PDF

Development of Numerical CCM in Pursuit of Accuracy Assessment for Coordinate Measuring Machines (정밀도 성능평가를 위한 3차원 측정기 수치모델 개발)

  • Park, Hui-Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.3
    • /
    • pp.945-959
    • /
    • 1996
  • In this paper, a comprehensive computer model is described which can be used to generate the volumetric error map combining the machine parametric errors and the measurement prove error, for most types of CMMs and axis configurations currently in use.

Measurement of the Three-Dimensional Flow Fields of a Gun-Type Gas Burner Using Triple Hot-Wire Probe (3중 열선 프로브를 이용한 Gun식 가스버너의 3차원 유동장 측정)

  • Kim, J.K.;Jeong, K.J.
    • Journal of Power System Engineering
    • /
    • v.10 no.3
    • /
    • pp.23-31
    • /
    • 2006
  • Mean velocities and turbulent characteristics in the three-dimensional flow fields of a gun-type gas burner were measured by using triple hot-wire probe (T-probe) in order to compare them with the results already presented by X-type hot-wire probe (X-probe). Vectors obtained by the measurement of two kinds of probes in the horizontal plane and in the cross section respectively show more or less difference in magnitude each other, but comparatively similar shape in overall distribution. Axial mean velocity component along the centerline shows that the value by T-probe is about ten times smaller than that by X-probe above the range of X/R=3. Also, the axial component of turbulent intensity along the centerline appears the biggest difference between the two probes. Moreover, axial mean velocity component, axial turbulent intensity component and rotational along the Y-directional distance show a big difference between slits and swirl vanes. On the whole, the values by T-probe appear smaller than those by X-probe.

  • PDF

무인 FMC에서의 인터프로세스(inter-process) 3차원 측정

  • 김선호;김선호;이춘식
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1992.04b
    • /
    • pp.29-38
    • /
    • 1992
  • 무인화된 대량생산 체제에서는 transfer line을 이용하게되며, cycle time의 단축을 위하여 측정 및 검사기능이 별도의 station으로 있어 가공후에 부품의 불량여부를 감지한다. 그러나 다품종소량생산체제에서는 FMC 또는 FMS가 적합하며, 이 시스템에 바람직한 감시기능으로서는 기내측정(inter-process)방식을 많이 이용한다. 여기서는 CNC선반과 머시닝센터에 접촉식 센서인 터치프로브(touch probe)를 설치하여 개발한 무인 FMC용 인터프로세스 3차원 측정 및 검사시스템을 소개한다.

  • PDF

Development of Managing System of Vision Probe for CMM (3차원 측정기용 비젼프로브 운용시스템 개발)

  • 박재성;박희재;김구영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.501-505
    • /
    • 1996
  • In CMM system, a contact probe is not applicable to very small, or flexible elements. There is need to develop non-contact probes of CCD camera. But non-contact probes have some technical problems, including distortion, user interface and time delay. This development gives the foundation of the non-contact probe system and some useful solutions for the problems. The results can be useful for industry application.

  • PDF

The Effect of Reynolds Number on the Three-Dimensional Flow Measurements with a Two-Stage Cone-Type Five-Hole Probe in a Non-Nulling Mode (Reynolds 수가 2단 원추형 5공프로브를 이용한 3차원 유동 측정에 미치는 영향 - 저속 유동장에서의 보정 결과 -)

  • Lee, Sang-U;Jeon, Sang-Bae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.1
    • /
    • pp.27-38
    • /
    • 2002
  • The effects of Reynolds number on the non-nulling calibrations of a cone-type ave-type probe in low-speed flows have been investigated at Reynolds numbers of 2.04$\times$10$^3$, 4.09$\times$10$^3$and 6.13$\times$10$^3$. The calibration is conducted at the pitch and yaw angles in ranges between -35 degrees and 35 degrees with an angle interval of 5 degrees. In addition to the calibration coefficients, reduced pitch and yaw angles, static and total pressures, and velocity magnitude are obtained through a typical non-nulling reduction procedure. The result shows that each calibration coefficient, in general, is a function of both the pitch and yaw angles, so that the pre-existing calibration data in a nulling mode are not enough in accounting far the full non-nulling calibration characteristics. Due to interference of the probe stem, the calibration coefficient are more sensitive to Reynolds number at positive pitch angles than at negative ones. The calibration data reduced in this study may serve as a guide line in the estimation of uncertainty intervals resulted from the Reynolds number effects at low Reynolds numbers.

Reconstruction of 3D Ultrasound Image from Freehand Scanned Frames Using Lateral Correlation Functions (측면거리 상관함수를 이용한 수동주사 초음파 영상 프레임들로부터의 3차원 영상 재구성)

  • 이준호;김남철;김상현
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.8B
    • /
    • pp.1152-1160
    • /
    • 2001
  • 본 논문에서는 수동주사로 얻은 2차원 연속 프레임으로 3차원 초음파 영상 재구성을 위한 연속 프레임의 프레임간 거리 추정 방법을 제안하였다. 수동주사로 얻은 연속 프레임은 프레임간 거리가 불균일하기 때문에 이를 그대로 3차원 영상으로 재구성하면 실제 인체 장기의 형태와 다른 영상을 얻게 된다. 제안한 알고리듬에서는 연속 프레임의 프레임간 거리를 추정하기 위하여 매 프레임의 블록별 측면거리 상관함수를 얻고, 측면거리 상관함수들이 프로브의 진행축과 초음파 센서의 배열축이 이루는 평면상에서 등방성을 가진다는 가정 하에 인접 프레임 내의 각 블록간의 프레임간 거리를 추정하였다. 인접 프레임간 추정거리는 프레임 내에서 블록단위로 추정된 프레임간 거리를 평균하여 얻었다. 실험 결과, 제안한 알고리듬의 프레임간 추정거리 곡선은 기준 진행거리 상관함수를 이용한 방법의 추정거리 곡선에 비해서 실제 프레임간 거리 곡선에 가까웠고, SNR 비교에서 제안한 방법이 기존의 방법에 비해 좋은 결과를 보였다. 그리고, 기존의 알고리듬에 비해 제안한 알고리듬으로 재구성한 3차원 영상이 원영상에 더 흡사한 것을 볼 수 있었다.

  • PDF

A Study of Development for Contact CMM Probe using Three-Component Force Sensor (3 분력 힘 센서를 이용한 CMM 용 접촉식 프로브의 개발에 관한 연구)

  • 송광석;권기환;박재준;조남규
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.8
    • /
    • pp.101-107
    • /
    • 2003
  • A new mechanical probe for 3-D feature measurement on coordinate measuring machines (CMMs) is presented. The probe is composed of the contact stylus and the three-component force sensor. With the stylus mounted on the force sensor, the probe can not only measure 3-D features, but also detect contact force acting on the stylus tip. Furthermore, the probing direction and the actual contact position can be determined by the relationship among three components of contact force to be detected. In this paper, transformation matrix representing the relationship between the external force acting on the stylus tip and the output voltages of measurement gauges is derived and calibrated. The prototype of probe is developed and its availability is investigated through the experimental setup for calibration test of the probe. A series of experimental results show that the proposed probe can be an effective means of improving the accuracy of touch probing on CMM.