• Title/Summary/Keyword: 3차원 볼륨렌더링 영상

Search Result 57, Processing Time 0.023 seconds

Medical Contents Visualization System for Smart Device (스마트 기기용 의료 콘텐츠를 위한 영상 가시화 시스템)

  • Kwon, Koojoo;Kang, Dong-Su;Kho, Youngihn;Shin, Byeong-Seok
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.10
    • /
    • pp.1264-1272
    • /
    • 2012
  • Three-dimensional volume rendering method which shows the inside of human body is widely used in medical imaging area. Existing medical imaging system using a volume rendering method already has provided a variety of three-dimensional results. Recently existing results in the medical imaging among physicians and patients to facilitate communication have been studied since smart device which has advantage of portability applied in the medical imaging. In this paper, we propose 3D volume visualization system for a relatively low spec portable smart devices by using 2D textures and we also implements 2D diagnostic images of portable medical imaging visualization system.

Volume rendering system for portable smart device (휴대용 스마트 기기를 이용한 볼륨렌더링 시스템)

  • Kwon, Koo-Joo;Kang, Dong-Su;Shin, Byeong-Seok
    • Proceedings of the Korea Multimedia Society Conference
    • /
    • 2012.05a
    • /
    • pp.120-122
    • /
    • 2012
  • 3 차원 볼륨렌더링 방법은 인체의 외형뿐만 아니라 내부의 모습도 투과하여 보여줄 수 있기 때문에 의료영상 분야에서 널리 사용된다. 기존의 의료영상 장비는 볼륨렌더링 방법을 이용하여 다양한 3 차원 영상을 제공하고 있다. 최근 의료영상 분야에서는 기존 의료영상 분야의 결과물을 휴대성과 이동성의 장점을 가진 스마트 기기에 도입함으로써 의사와 환자들의 편의를 도모하고 소통을 원활하게 하려고 노력하고 있다. 본 논문에서는 비교적 저사양인 휴대용 스마트 기기에 적합한 3 차원 볼륨 가시화하는 방법을 제안한다.

  • PDF

A Block-Based Volume Rendering Algorithm Using Shear-Warp factorization (쉬어-왑 분해를 이용한 블록 기반의 볼륨 렌더링 기법)

  • 권성민;김진국;박현욱;나종범
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.4
    • /
    • pp.433-439
    • /
    • 2000
  • Volume rendering is a powerful tool for visualizing sampled scalar values from 3D data without modeling geometric primitives to the data. The volume rendering can describe the surface-detail of a complex object. Owing to this characteristic. volume rendering has been used to visualize medical data. The size of volume data is usually too big to handle in real time. Recently, various volume rendering algorithms have been proposed in order to reduce the rendering time. However, most of the proposed algorithms are not proper for fast rendering of large non-coded volume data. In this paper, we propose a block-based fast volume rendering algorithm using a shear-warp factorization for non-coded volume data. The algorithm performs volume rendering by using the organ segmentation data as well as block-based 3D volume data, and increases the rendering speed for large non-coded volume data. The proposed algorithm is evaluated by rendering 3D X-ray CT body images and MR head images.

  • PDF

Implementation of Modified Shear-warp Volume Rendering in TMS320C6201 (TMS320C6201에 적합하게 보정된 쉬어-윕 볼륨렌더링 구현)

  • 최석원;권민정;박현욱
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.5
    • /
    • pp.519-526
    • /
    • 2000
  • 볼륨 렌더링은 3D 의료영상 데이터를 가시화하는 중용한 기법 중 하나이다. 그러나 볼륨 렌더링을 실시간으로 이룰 때, 많은 계산량을 필요로하는 것이 볼률 렌더링을 사용하는데 걸림돌이 되고 있다. 이 논문에서는 Superscalar와 VLIM(Very Long Instruction Word)의 구조를 가지고 있어 동시에 8개의 명령어 수행이 가능한 TI사의 TMS320C6201 DSP를 이용하여 3D 초음파 영상의 쉬어-웝 볼륨 렌더링을 구현하였다. 쉬어-웝 방법을 DSP 상에서 최적으로 구현하기 위하여 ray map 방법, one-to-four ray casting, ?디 skipping 방법을 제안하였다. 제안한 방법들을 이용한 볼륨 렌더링과 적용하지 않은 기존의 알고리즘을 DSP에 구현하여 PSNR과 렌더링 시간의 비교·평가를 통해 만족할 만한 영상 화질에 빠른 렌더링 성능을 얻을 수 있음을 보여주었다.

  • PDF

A Phantom study of Displacement of Three Dimensional Volume Rendering for Clinical Application in Radiation Treatment Planning (방사선치료계획의 임상적용을 위한 3차원 볼륨렌더링영상 체적변화의 모형연구)

  • Goo, Eun-Hoe;Lee, Jae-Seung;Lim, Cheong-Hwan
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.11
    • /
    • pp.280-288
    • /
    • 2009
  • This study is to design and produce a detailed model for volume variety of three dimensional reconstruction images and to evaluate the changes of volume, area and the length of the model in the process of the reconstruction of RTP system. CT simulation was operated at the thickness of 1.25, 2.5, 5, 10mm and average, standard deviation of scan direction(X), thickness(Y), table movement direction(Z), area(A), and volume(V) of the three dimensional volume rendering, were measured according to the shape and thickness of the phantoms. As a result, at the thickness of 1.25, 2.5min, the phantom's shape decreased maximum 0.13cm(p<0.05) to the direction of X, Y, Z and length, area, volume decreased 0.1cm, $0.8cm^2$, $3.99cm^3$ which led to an approximate image of the phantoms. However, at the thickness of 5, 10mm, the phantom of the original form decreased maximum 0.58cm(p<0.05) and volume, area, length decreased maximum 0.45cm, $8.21cm^2$, $11.03cm^3$. Volume varieties according to the thickness and shape of the phantoms have occurred diversely, when CT simulation was operated, and it is considered that a clinically appropriate volume rendering can be obtained only when the thickness is below 3mm.

Performance Evaluation of Parallelization Methods for Volume Rendering (볼륨렌더링을 위한 병렬화 방법들의 성능평가)

  • 김진호;김남규;김지인;정갑주
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 1999.10b
    • /
    • pp.641-643
    • /
    • 1999
  • 많은 처리시간을 요구하는 대규모 3차원 데이터의 영사화(대규모 볼륨렌더링)에서는 병렬처리가 반드시 요구된다. 대규모 볼륨렌더링의 처리시간은 크게 데이터입력 시간과 입력된 데이터의 영상화(연산) 시간으로 구성된다. 따라서 데이터 입력 과정과 연산 과정 모두를 병렬화할 필요가 있다. 입출력 병렬화 및 알고리즘 병렬화는 각각 독립적으로 적용가능하다. 본 논문에서는 (1)순차 볼륨렌더링, (2)병렬연산 기반 볼륨렌더링, (3)병렬입출력 기반 볼륨렌더링, (4) 병렬연산 및 병렬입출력 기반 볼륨렌더링 등 네 가지 경우를 각각 구현하여 성능을 비교하였다. 실험결과에서는 병렬연산 및 병렬 입출력이 동시에 적용되는 (4)가 가장 좋은 성능을 보이는 것으로 나타났다.

  • PDF

An Efficient Rendering Method for Anisotropic Volume Data in 3D Medical Imaging (3차원 의학영상 처리에서 사용되는 비균등 볼륨 데이터를 위한 효율적인 렌더링 방법)

  • 김태영;신병석
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.6
    • /
    • pp.491-498
    • /
    • 2002
  • In medical visualization fields, anisotropic volume data are more common than isotropic ones. In this paper, we propose an efficient rendering method for anisotropic volume data, which directly computes the intensity of intermediate samples by interpolating the intensity of two corresponding voxels on consecutive slices. Unlike conventional rendering method, it does not require a preprocessing step for generating intermediate slices or additional memory for storing them. In order to evaluate the validity and performance of our method, we applied the method to shear-warp rendering algorithm. Experimental results show that this method improves rendering speed without significantly sacrificing the image quality.

한국인 인체영상 정보시스템의 구축

  • Park, Jong-Seung;Park, Hyeong-Seon;Im, In-Seong;Kim, Myeong-Ho
    • Journal of Scientific & Technological Knowledge Infrastructure
    • /
    • s.5
    • /
    • pp.31-40
    • /
    • 2001
  • 한국인의 인체 절단면 영상으로부터 인체의 3차원 데이터를 생성하였다. 다양한 종류의 3차원 렌더링 영상을 제작하고 이를 기반으로 하는 웹 기반정보시스템을 구축하였다. 인체 영상 정보시스템은 크게 렌더링에 필요한2차원 데이터를 생성하는 단계, 3차원 렌더링 데이터를 생성하는 단계, 영상을 데이터베이스화하고 이를 서비스하기 위한 시스템 구현 단계의 세 부분으로 나눌수 있다. 렌더링을 위한 2차원 영상처리는 절단면 영상의 분할과 정렬을 포함한다. 분할은 절단면 영상에 보여지는 인체의 부위를 구분하도록 하는 절차이고, 정렬은 왜곡된 영상 위치를 바로잡기 위한 절차이다. 3차원 렌더링은 절단면 영상들로부터 3차원 모델의 뷰를 생성하는 절차이다. 병렬처리를 통한 광선 추적 볼륨 렌더링 기법을 사용하여 잘라보기 및 돌려보기 렌더링 뷰를 생성한다. 각 절단면 영상 및 렌더링 영상은 인체영상 브라우저 및 검색기가 접근할 수 있도록 웹 시스템에 로드 하였다. 브라우저는 인체의 위치를 시각적으로 탐색 할 수 있도록 구현되었다. 각 단계별 기술적인 내용을 소개한다.

  • PDF

3D Medical Data Specification and Visualization Based on XML (XML 기반의 3차원 의료 데이터의 명세 및 가시화)

  • Kim, Seung-Wan;Park, Deok-Gyu;Gwun, Ou-Bong;Lee, Kun
    • Journal of the Korea Computer Graphics Society
    • /
    • v.10 no.4
    • /
    • pp.6-12
    • /
    • 2004
  • 웹은 플랫폼에 의존하지 않고 모든 사람들이 공통으로 이용할 수 있는 인터페이스를 제공하기 때문에 웹브라우저상에 3차원 의료 데이터를 가시화하여 표현한다면 원격 진단, 의료 교육 등에 이용될 수 있다. 이 논문은 3차원 의료정보를 3차원 의료 볼륨 데이터, 3차원 의료 영상, 볼륨 렌더링 응용의 3 종류로 구분하여 이들을 XML로 표현하는 방법 및 텍스처 맵핑 기반의 디렉트볼륨렌더링(Direct Volume Rendering)을 SVG(Scalable Vector Graphics)으로 표현하여 SVG 뷰어 상에 표시하는 방법을 제안한다. 제안 방법의 실행 결과는 웹 브라우저 상에서 의료데이터의 분석이 가능하게 하고, 또한 볼륨렌더링 응용프로그램을 SVG로 표현, 결과 이미지를 SVG 뷰어로의 표시가 가능하다는 것을 보여준다.

  • PDF

HU Threshold Value for IV Catheter Fragment in Peripheral Vein of Volume Rendering 3D MDCT Imaging (정맥 내의 IV 카테터 조각을 3D MDCT 볼륨렌더링 영상으로 구현하기 위한 HU 임계치)

  • Jang, Keun-Jo;Kweon, Dae-Cheol
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.4
    • /
    • pp.206-212
    • /
    • 2007
  • To evaluate the HU value of the IV catheter fragment of CT on the accuracy and size in the peripheral vein. Pilot study of profile and table functions on PC by software was calculated of HU value of IV catheter fragment. This study demonstrates the utility of volume rendering technique to localize a small, subtle IV catheter, which can easily be reformatted of MDCT reformations. IV catheter fragment optimal image described as threshold range. Volume rendering of HU using a MDCT is an excellent method for evaluation the IV catheter fragment in three dimension.