• Title/Summary/Keyword: 3차원초음파

Search Result 186, Processing Time 0.021 seconds

Real-Time 3D Ultrasound Imaging Method Using a Cross Array Based on Synthetic Aperture Focusing: I. Spherical Wave Transmission Approach (합성구경 기반의 교차어레이를 이용한 실시간 3차원 초음파 영상화 기법 : I. 구형파 송신 방법)

  • 김강식;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.5
    • /
    • pp.391-401
    • /
    • 2004
  • 3D imaging systems using 2D phased arrays have a large number of active channels, compelling to use a very expensive and bulky beamforming hardware, and suffer from low volume rate because, in principle, at least one ultrasound transmit-receive event is necessary to construct each scanline. A high speed 3D imaging method using a cross array proposed previously to solve the above limitations can implement fast scanning and dynamic focusing in the lateral direction but suffer from low resolution except at the fixed transmit focusing along the elevational direction. To overcome these limitations, we propose a new real-time volumetric imaging method using a cross array based on the synthetic aperture technique. In the proposed method, ultrasound wave is transmitted successively using each elements of an 1D transmit array transducer, one at a time, which is placed along the elevational direction and for each firing, the returning pulse echoes are received using all elements of an 1D receive array transducer placed along the lateral direction. On receive, by employing the conventional dynamic focusing and synthetic aperture method along lateral and elevational directions, respectively, ultrasound waves can be focused effectively at all imaging points. In addition, in the proposed method, a volume of interest consisting of any required number of slice images, can be constructed with the same number of transmit-receive steps as the total number of transmit array elements. Computer simulation results show that the proposed method can provide the same and greatly improved resolutions in the lateral and elevational directions, respectively, compared with the 3D imaging method using a cross array based on the conventional fixed focusing. In the accompanying paper, we will also propose a new real-time 3D imaging method using a cross array for improving transmit power and elevational spatial resolution, which uses linear wave fronts on transmit.

The Enhancement of the Acoustic Image by Combining Bases of Support for SFR (Spatial Frequency Response) (공간주파수응답의 기저대역 확장에 의한 초음파영상의 개선)

  • Song, Dae-Geon;Oh, Tong-In;Kim, Hyun;Jun, Kye-Suk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.5
    • /
    • pp.408-417
    • /
    • 2003
  • In this paper, we have studied the enhancement of the acoustic image by combining bases of support for SFR (Spatial Frequency Response) taken at multi-frequencies. The scanning acoustic microscope system have been constructed using the quadrature detector that is able to measure the amplitude and phase of the reflected signal simultaneously. Both real and quadrature components of reflected signal have been acquired at 4.4 ㎒ to 5.6 ㎒ reliably and accurately. In this experimental result, better depth resolution can be obtained by numerically combining images taken at several different frequencies. Image intensity have been better about 3.4 times at multi-frequency than one at a single frequency.

Microfluidic Device for Ultrasound Image Analysis based on 3D Printing (초음파 영상 분석을 위한 3D 프린팅 기반 미세유체소자)

  • Kang, Dongkuk;Hong, Hyeonji;Yeom, Eunseop
    • Journal of the Korean Society of Visualization
    • /
    • v.16 no.1
    • /
    • pp.15-20
    • /
    • 2018
  • For the measurement of biophysical properties related with cardiovascular diseases (CVD), various microfluidic devices were proposed. However, many devices were monitored by optical equipment. Ultrasound measurement to quantify the biophysical properties can provide new insights to understand the cardiovascular diseases. This study aims to check feasibility of microfluidic device for ultrasound image analysis based on 3D printer. To facilitate acoustic transmission, agarose solution is poured around 3D mold connected with holes of the acrylic box. By applying speckle image velocimetry(SIV) technique, flow information in the bifurcated channel was estimated. Considering that ultrasound signal amplitude is determined by red blood cell (RBC) aggregation, RBC aggregation in the bifurcated channel can be estimated through the analysis of ultrasound signal. As examples of microfluidic device which mimic the CVD model, velocity fields in microfluidic devices with stenosis and aneurysm were introduced.

Real-Time 3D Ultrasound Imaging Method Using a Cross Array Based on Synthetic Aperture Focusing: II. Linear Wave Front Transmission Approach (합성구경 기반의 교차어레이를 이용한 실시간 3차원 초음파 영상화 기법 : II. 선형파면 송신 방법)

  • 김강식;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.5
    • /
    • pp.403-414
    • /
    • 2004
  • In the accompanying paper, we proposed a real. time volumetric imaging method using a cross array based on receive dynamic focusing and synthetic aperture focusing along lateral and elevational directions, respetively. But synthetic aperture methods using spherical waves are subject to beam spreading with increasing depth due to the wave diffraction phenomenon. Moreover, since the proposed method uses only one element for each transmission, it has a limited transmit power. To overcome these limitations, we propose a new real. time volumetric imaging method using cross arrays based on synthetic aperture technique with linear wave fronts. In the proposed method, linear wave fronts having different angles on the horizontal plane is transmitted successively from all transmit array elements. On receive, by employing the conventional dynamic focusing and synthetic aperture methods along lateral and elevational directions, respectively, ultrasound waves can be focused effectively at all imaging points. Mathematical analysis and computer simulation results show that the proposed method can provide uniform elevational resolution over a large depth of field. Especially, since the new method can construct a volume image with a limited number of transmit receive events using a full transmit aperture, it is suitable for real-time 3D imaging with high transmit power and volume rate.

Two Visualization Techniques Using Smoke-wire and Micro Water-droplets and Their Applications to Vortex Flows (연기선과 미세 수적을 이용한 두 가지 가시화 기법과 와류에의 적용)

  • Sohn, Myong Hwan
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.12
    • /
    • pp.1017-1026
    • /
    • 2016
  • The present paper describes the two off-surface visualization techniques and their application examples to vortex flows. One of the two visualization techniques is the classical smoke-wire technique, and the other is the visualization technique using the micro water-droplets generated by the home-style ultrasonic humidifier. The smoke-wire technique has the limit of air flow speed (about 5 m/sec for 0.07 mm-diameter wire) and the pollution problem, but it produces very fine and clear streak line sheet. It is applied to visualize the wing-tip vortices of a 3-dimensional wing. The micro water-droplet technique has the larger limit of air flow speed (above 10 m/sec) and is free from pollution and toxic problems compared to the smoke-wire technique. It is successfully applied to visualize the complex vortex system of a double-delta wing with an apex strake.

Feasibility Study on Detection of Defective Elements in a Linear Phased Array Transducer through Ultrasonic Field Analysis and Visualization (초음파 음장해석 및 가시화를 통한 선형 위상차배열 트랜스듀서의 결함요소 검출 가능성 연구)

  • Choi, Kwang-Yoon;Yang, Jeong-Won;Ha, Kang-Lyeol;Kim, Moo-Joon;Kim, Jung-Soon;Lee, Chae-Bong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.5
    • /
    • pp.416-423
    • /
    • 2009
  • The ultrasonic pressure fields for the 3 MHz linear phased array transducer with sixteen piezoelectric elements of which one may not be operated by defect were simulated theoretically and measured experimentally using a visualization system of the Schlieren method. The simulation results for steering angles of $0^{\circ}$ and $30^{\circ}$ show that the side-lobe patterns of the transducer including a defective element is quite different from the transducer with all normal elements, and those patterns are in good agreement with the results of visualization. It is shown that the defective elements in a linear array transducer can be detected by comparison of the simulated and the visualized side-lobe patterns in two dimensional acoustic fields.

연구실탐방 - KIST 로보틱스연구 팀

  • Korean Federation of Science and Technology Societies
    • The Science & Technology
    • /
    • v.30 no.2 s.333
    • /
    • pp.84-85
    • /
    • 1997
  • 휴먼로봇프로젝트를 실현시키기 위해 KIST가 94년 4월 제어시스템연구실에 설립한 로보틱스연구팀. 산업용 로봇의 모터가 6개 정도라면 휴먼로봇은 60개의 모터가 들어가야 하는 작업으로 3차원 거리측정시스템, 방해물감지 초음파시스템 등 다양한 연구가 진행중이다. 국산 휴먼 로봇이 탄생되면 원자력발전소나 지뢰탐사 폭발물제거작업 등에 투입될 것이다.

  • PDF

A Study on the 3-Dimensional Implementation of Computer-Aid Management of Stereo Images (입체 화상의 3차원 전산모사기 구현에 관한 연구)

  • Lee, Joong;Yoon, Do-Young
    • Korean Chemical Engineering Research
    • /
    • v.47 no.2
    • /
    • pp.179-184
    • /
    • 2009
  • Recent evolution of computer technology enhances the effectiveness of CFD(Computational Fluid Dynamics) analysis for the 3-dimensional complex transport phenomena including turbulent flows. Cheaper and easier than laser and ultra-sonic methods, the windows simulator name by CAMSI(Computer-Aided Management of Stereo Images) has been developed in order to implement the 3-dimensional image using a disparity histogram extracted from left and right stereo images. In our program using the area-based method, the matching pixel finding methods consist of SSD(Sum of Squared Distance), SAD(Sum of Absolute Distance), NCC(Normalized Correlation Coefficient) and MPC(Matching Pixel Count). On performing the program, stereo images on different window sizes for various matching pixel finding methods are compared reasonably. When the image has a small noise, SSD on small window size is more effective. Whereas there is much noise, NCC or MPC is more effective than SSD. CAMSI from the present study will be much helpful to implement the complex objects and to analyze 3-dimensional CFD around them.

Rapid Manufacturing of 3D Thin-walled Products using Plastics and Metals (플라스틱과 금속재료를 이용한 3 차원 박벽 제품의 쾌속 제작)

  • Shin Bo-Sung;Kang Bo-Sik;Park Jae-Hyun;Rho Chi-Hyun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.8 s.185
    • /
    • pp.195-202
    • /
    • 2006
  • High-speed machining (HSM) with excellent quality and dimensional accuracy has been widely used to create 3D structures of metal and plastics. However, the high-speed machining process is not suitable for the rapid realization of 3D thin-walled product because it consumes considerably long time in fixturing process of a work piece. In this paper, an effective rapid manufacturing process is proposed to fabricate 3D thin-walled products directly using HSM, phase change filling and ultrasonic welding. The filling process is useful to hold the thin-walled product during the machining step. The ultrasonic welding process is introduced to make one piece product from two piece parts that are machined by HSM and filling process. The proposed rapid manufacturing (RM) process has been shown that the RM process enables to fabricate the 3D thin-walled products using ABS plastics and aluminum metals from 3D CAD data to functional parts.

Gestational Age Prediction by Using Transverse Cerebellar Diameter of Korean Fetal Biometry (한국인태아의 소뇌형직경을 이용한 임신주수 예측)

  • Yang, Sung-Hee;Kim, Jeong-hoon;Kim, Changsoo
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2015.05a
    • /
    • pp.195-196
    • /
    • 2015
  • 태아의 소뇌는 임신주수에 따라 성장하며 소뇌횡직경 길이의 측정은 태아성장 예측의 중요한 지표로 활용하고 있다. 임신주수에 따른 태아 소뇌횡직경의 성장을 회귀곡선으로 표시하였고 선형회귀방정식에서 결정계수를 얻었다. 3차원초음파를 이용한 소뇌횡직경의 측정법은 통계적으로 유의(P<0.001)하였으며, 태령을 예측함에 유용하다는 것을 알 수 있었다. 또한 성장장애가 있는 태아의 경우에도 임신주수의 예측이 가능하다. 본 연구를 기초자료로 하여 지속적인 연구가 시행된다면 정확한 임신주수 예측에 유용할 것으로 기대한다.

  • PDF